HomeMy WebLinkAboutR-431801AS -BUILT RECORD SET 03/21/2024
1 11-/111-\1 r%
z
CQ
/G
V
rr
LLI
m
Z
w
0-
HALF STREET GRIND
AND OVERLAY
REQUIRED
CB (TYPE 1)
I
�
o
RIM=120.86'
o
N
�
IE(N.) 12"CPP=116.31'
:.
I E(S.) 12 "CPP=116. 61 '
...... -'-'7'
"-== - .=-____
NEW DRIVEWAY APPROACH
PER COR STD-104.1
-
-
CB (TYPE 1)
�. _..."
21:9
RIM=122.16'' 122.20'
o
�. .
IE N. 12"CPP=12e..26' 122.20'
N
IE(E.) 4-L' 6"PVC=1z�8 9fr
c�
122.30'
IE(S.) 12"CPP=129.3E 122.30'
PAVEMENT
...•
:.i �..: �.........
I. b .. .
RESTORATION PER
/•"• -
.
I
I
CB (TYPE 1) I
RIM=121.el' 122.00'
IE(N.) 12"D1=1-18.56 118.60'
IE(S.) 12"D1=118.86' 11&80' O 1g��
121.53t �2'10 P p40 I
MATCH EXISTING
POWER POLE
SDCO PER COR STD 226.00 I
(TYP) I
IE (W) 4" PVC=121.1t
IE (SE,FOOT) 4" PVC=121.1t
IE (E,ROOF) 4" PVC=121.1t 10' X 2' LEVEL I
PERFORATED PIPE
CONNECTION PER COR
_ STD 263.40 -
126 -
Ett--�G--- PG- G-- P G-- P P
2' ,. I..� 1 'a a : a8.6%
28 LF 4" PVC
® 27. MIN a
12 TV� 40
:. s
a a BW=127.5. Q s
it a
COR-STD 110.1 ..�.�......:.: I TW=128.0 / I
I BW-124 0
APPROX. LOCATION PER
-
- - ..
1
1
-
PAINT AAAPIIC /TYPE
f..'.'.'..
- - -S.. . -
f ..
4. I
ys
-��
0.
w
-
Z-c� ..
APPROXIMATE LOCATION OF
EXISTING SIDE SEWER.
LLJ
SSCO
CONTRACTOR TO VERIFY...
j
I
RIM=128.Ot
LOCATION AND DEPTH
z."..;
".
Q....I
I
oM
IE-119.0t
(SEE SIDE SEWER NOTES)
o
N
^
I _
�4
cD 50 LF 4" PVC'
CB TYPE 1 `
Q
_ "..o..�.�...a�...
..o.......�...
<
1.
°
® 2q MIN
RIM=123.95' 123.96'
Q
{
1 0
o
TW=128.0
LBW=124.0
IE(N.) 12"GONG=121 8r 121.71'
..
I
IE(S.) 12"CPP=121.99' 121.81'
oW."."."."."
".`�'•
_...-_
I
I .
z
NEW 1" WATER METER PER CDR STD-320.1
.......�
........ .
11
BERGMAN RESIDENCE
SE 1/4 OF NW 1/4 OF SECTION 32, T. 24 N., R. 05 E., W.M.
CITY OF RENTON, KING COUNTY, WASHINGTON
I
20 P�
Opp '��6 I
I
I
�
� 0 o 9$0�`
2�pp9 0�b
�b21 �P
N
1�1 r1�p�
E�(
PROPOSED
I
THICKENED I
EDGE
I
GRAPHIC
SCALE
N 88 50S1 " W 250.02= 1
20
0 10 20
\-
-
\ �
10' BSBLI \\
p
C0�
SCALE:
1" = 20'
rt
PROPOSED
(3)121 ';6"D
C \�
\
1 LF 4" PVC UNDERGROUND
��_ '_1�_L
119 POWER
SERVICE LINE
I
'
(No
0 (TYP)
PROPOSED GAS
SERVICE LINE
ILO
'ARCEL
\
�30 3342700515
\
I
\
o�
\
130� 25,876t SQ FT
0.59 ACRE(S) O
Z
° 6M
col \
FOUNDA17ON LINE W/ 4"
I
/
COVERED I DRAIN
PERFORAIED PVC FOOTING I NZ�p�69 0"6
PATIO (TIP) g$
TO BE INSTALLED
SEPARATE WATER METER PERMI UNDER T.
........ I.BY CITY FORCES
, /. FG.=130.50 - _ I 1�22 �pr1
PRESSURE REDUCING VALVE REQUIRED ��� j �a ^
MATCH 7 EXISTING .. PROPOSED
DOWNSTREAM OF WATER METER I RESIDENCE _
GRADE �
EXISTING WATER METER TO BE SSMH �vr 1 PROPOSED o MFF=130.75 I N
j. aa: J I LANDSCAPE 69 LF 4" PVC \
CUT AND CAPPED AT MAIN LINE RIM=125.09' " " . _.. ® 1% 132
BY CITY FORCE UNDER SEPARATE IE(N./SE./SW.) 8"GONG ...."0 • •"- `�� I I m WALL (TYP) /
73 LF 4" PVC /
WATER METER PERMIT=105.19'(C. C.) ¢ .. . . . I . I a m Ln ®1%
SAWCUT LINE . .. I ... 12
SIDE SEWER NOTE ;� .... �.. - 5 0
EXISTING SIDE SEWER TO BE CCTV TO DE7ERMINE CB (TYPE 1)
IF IT CAN BE REUSED. CCTV TO BE PROVIDED TO CITY RIM=124.79'
INSPECTOR FOR REVIEW. LINING OF 7HE EXISTING IE(N.) 12"CMP=121.19'
STUB MAY BE REQUIRED. A NEW PVC SIDE SEWER CB (TYPE 1)
CONNECTION WILL BE REQUIRED IF REUSE
DETERMINED INFEASIBLE. RIM=i25�.'r' 125.75'
1E(N.) 12"CPP=1223'' 122.00'
IE(E.) 8"CPP=122.5;3' 122.45:
IE(S.) 12"CPP=+n� 122.15
APPROX. LOCATION
PER RECORDS (TYP)
Know what's below.
call before you dig.
130
125
120
GUKtf- .d a
1 •�3 d,
GARAGE
SS HI SLAB=128.83
LO SLAB=128.50
DOWNSPOUT W/
CLEANOUT FILTER
a. PER COR SID
263.40 -
CONNECT FOOTING
DRAIN SYSTEM TO 4"
a PVC
6" SS PVC
® 21 MIN
/TEMP POW' -
TW=128.Ot
BW=12 .5t PROPOSED
CENTERLINE OF JOINT USE TRENCH FOR FUTURE n 9 LANDSCAPE WALL
DRY UTILITIES. CONTRACTOR TO INSTALL a TW=132.00
CONDUITS ONLY. CONNECT TO EXISTING CONDUITS BW=130.00
TO 7HE SOUTH INSTALLED UNDER LUA17-000503 `.
126.38t pe'
SDCB p�6
RIM=126.55' �p g$
IE(W.) 8"ADS=123.15' SOU I
IE(N.) 6"ADS=123.15'
IE(E.) 8"ADS=122.45' I
REMOVE EXISTING ASPHALT
TRANSITION RAMP AND REPLACE W/ I
PLANTER STRIP AND SIDEWALK.
MATCH GRADE OF EXIS71NG SIDEWALK
. . . . . . N
.....
Q
.I
.....
......
.....
.....
.....R:
. . . . .
W
v�-i
-
I
EXIS111VG PROFILE
. .
. . .
. .
•�• .
. . . . .
GRADE. (TYP) .
PROPOSED .
>
. . .
. . . . . .
_
_
. . . .
. FLOWLINE
�.
. . . . .
. . . . .
. .
- _ _ `
. . . . .
. . . . .
. . . . .
. . . . .
. .
. . .
. . . . .
..
. . . . .
. . . . .
. .
. . .
. . . . .
-
�,
•.p.cu
. . . . .
. . . . .
. .
. . .
. . . . .
. . . . . .
W.
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . .
. . .
. . .
. . . . .
. . . . .
. . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . .
. . .
. . .
. . . . . . .
. . . . . . . .
. . .
. . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . .
. . . .
. . .
12+00
ccpp M LOLO ^ O O O
N N N N N N
W W W W W W LOi
13+00
PARK AVE N PROFILE
HORIZ.: 1"--20, VERT.• 1 "--5'
CIVIL1700 NW GILMAN BLVD, STE 200
ISSAQUAH, WA 98027
PHONE: (425) 821-5038
r.
m
130
125
120
13+50
i - 8»cl 1 I/ 6»DEC 1
N 88 °47'41 ' W 250.02' - - � 1 8 O
D 18"DEC \ T
1013, 4-
�b
�12 JE �
2�ll 0"Do
0�6 I
RECORD DRAWING NOTE:
THIS RECORD DRAWING HAS BEEN PREPARED BY G2 CIVIL. THE INFORMATION
PRESENTED HEREON IS BASED UPON A COMBINATION OF APPROVED DESIGN
PLAN INFORMATION, CONTRACTOR AND INSPECTOR FIELD DRAWINGS PREPARED
DURING THE COURSE OF CONSTRUCTION, AS -BUILT FIELD SURVEY INFORMATION
GATHERED BY THE PROJECT LICENSED SURVEYOR OVER THE COURSE OF THE
PROJECT CONSTRUCTION, AND OTHER RECORD INFORMATION PROVIDED BY OTHERS.
THIS RECORD DRAWING PRESENTS ACCURATE AS -BUILT CONDITIONS TO THE BEST
KNOWLEDGE OF THE ENGINEER OF RECORD AND WAS PREPARED SOLELY FOR
USE BY THE CITY OF SEATTLE. ANY OTHER USER OF THIS RECORD DRAWING
BEARS COMPLETE RESPONSIBILITY TO FIELD VERIFY ACTUAL FIELD LOCATIONS AND
CONDITIONS AT THE TIME OF USE AND IS HEREBY ADVISED TO DO SO.
AS -BUILT RECORD SET
REVISED PER CITY COMMENTS
REVISED PER CITY COMMENTS
SUBMITTED TO CITY
REVISION
SURVEYED:
WJR
03/21/24
EDM
DESIGNED:
NM
05/05/23
EDM
NM
04/05/23
EDM
DRAWN. JAT
JAT
02/09/23
NEM
CHECKED:
NEM
BY
DATE
APPR
APPROVED:
NEM
SCALE:
1 "=20'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL NAVD 1988
HORIZONTAL NAD 1983/1991
DATUM
_
ASPHALT SURFACE
�XS�XXXS�XXXXS
BUILDING
-1
CENTERLINE POW
CO °
CLEANOUT
0
CONCRETE SURFACE
®
DECK
FENCE LINE (CHAIN LINK)
XX
X X
FENCE LINE (WIRE)
FENCE LINE (WOOD)
GAS LINE
G
HBO
HOSE BIB RISER
HEDGE FOLIAGE LINE
0
INLET (TYPE 1)
LP 0-----❑
LIGHT POLE
►��
MONUMENT IN CASE (FOUND)
• OHPT
OHP TRANSMISSION LINE
PST ❑ POST
P ❑ POWER METER
P POWER (OVERHEAD)
PC~-0 POWER POLE W/ LIGHT
RETAINING WALL
O REBAR AS NOTED (FOUND)
REBAR & CAP (SET)
ROCKERY
SS SEWER LINE
(v) SEWER MANHOLE
SD STORM DRAIN LINE
TEL SENTRY ❑ TELEPHONE SENTRY
SIZE TYPE ` TREE (AS NOTED)
W WATER LINE
WM u WATER METER
NAIL AS NOTED
NEV
TO
SOIL QUALITY NOTE
ALL AREAS SUBJECT TO CLEARING AND GRADING THAT HAVE NOT BEEN COVERED BY IMPERVIOUS SURFACE,
INCORPORATED INTO A DRAINAGE FACILITY OR ENGINEERED AS STRUCTURAL FILL OR SLOPE SHALL, AT PROJECT
COMPLETION, DEMONSTRATE THE FOLLOWING:
1. A TOPSOIL LAYER WITH A MINIMUM ORGANIC MATTER CONTENT OF 107. DRY WEIGHT IN BEDS, AND 57.
ORGANIC MATTER CONTENT IN TURF AREAS, AND A PH FROM 6.0 TO &0 OR MATCHING THE PH OF THE
UNDISTURBED SOIL. THE TOPSOIL LAYER SHALL HAVE A MINIMUM DEPTH OF EIGHT INCHES EXCEPT WHERE TREE
ROOTS LIMIT THE DEPTH OF INCORPORATION OF AMENDMENTS NEEDED TO MEET THE CRITERIA. SUBSOILS BELOW
THE TOPSOIL LAYER SHOULD BE SCARIFIED AT LEAST 4 INCHES WITH SOME INCORPORATION OF THE UPPER
MATERIAL TO AVOID STRATIFIED LAYERS, WHERE FEASIBLE.
2. MULCH PLANTING BEDS WITH 2 INCHES OF ORGANIC MATERIAL.
3. USE COMPOST AND OTHER MATERIALS THAT MEET THESE ORGANIC CONTENT REQUIREMENTS:
A) THE ORGANIC CONTENT FOR 'PRE -APPROVED" AMENDMENT RATES CAN BE MET ONLY USING COMPOST
MEETING THE COMPOST SPECIFICATION FOR BIORETENTION (REFER TO SECTION C.2.6) WITH THE EXCEPTION THAT
THE COMPOST MAY HAVE UP TO 357. BIOSOLIDS OR MANURE. THE COMPOST MUST ALSO HAVE AN ORGANIC
MATTER CONTENT OF 40% TO 65%, AND A CARBON TO NITROGEN RATIO BELOW 25:1. THE SECTION C.2
ON -SITE BMPS 1211212016 2017 CITY OF RENTON SURFACE WATER DESIGN MANUAL C-100 CARBON TO
NITROGEN RATIO MAY BE AS HIGH AS 35:1 FOR PLANTINGS COMPOSED ENTIRELY OF PLANTS NATIVE TO THE
PUGET SOUND LOWLANDS REGION.
B) CALCULATED AMENDMENT RATES MAY BE MET THROUGH USE OF COMPOSTED MATERIAL MEE7NG A)" ABOVE;
OR OTHER ORGANIC MATERIALS AMENDED TO MEET THE CARBON TO NITROGEN RA770 REQUIREMENTS, AND NOT
EXCEEDING THE LIMITS IDENTIFIED IN TABLE 220-B, TESTING PARAMETERS, IN WAC 173-350-220.
4. THE RESULTING SOIL SHOULD BE CONDUCIVE TO THE T1PE OF VEGETATION TO BE ESTABLISHED.
L
I
27' MIN.
12'-15' DRI VEWA Y
1.5' THICKENED EDGE
PER C.O.R. STD
5'
FLOW LINE
4" HMA CLASS
112" 64-22
6" CRUSHED ROCK
NOTE.
EXCAVATE TO REMOVE ANY UNSUITABLE SOIL
DRIVEWAY SECTION
CITY OF
RENTON
Planning/Building/Public Works Dept.
NTS
N
O
N
N
M
O
H
LU
G
O
U
LU
H
J
m
Q
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
BERGMAN
SFR
SITE GRADING, DRAINAGE,
& UTILITY PLAN AS-BUILTS
rr
'H
V J
DATE: z
03-21-2024 Q
FIELDBOOK: -
PAGE: - i I�
DRAWING NO:
LU
SHEET: 3 OF: 6 W