HomeMy WebLinkAboutS-3921011�
N
r
D
5
If
>1
V I U I IN I I Y IVI/-\r
NTS
�i
THUNDER HILLS SEWER INTERCEPTOR
BURIED UTILITIES IN AREA
CALL BEFORE YOU DIG
1-800-424-5555
EXISTING UTILITIES SHOWN ARE FROM
THE BEST AVAILABLE INFORMATION AND
NO GUARANTEE IS MADE AS TO THE
EXACT SIZE, TYPE, LOCATION OR DEPTH.
REHABILITATION
WWP-27-03921
Stantec
1687 114TH Avenue SE, Suite 100
Bellevue WA 98004 phone: (425)
869-9448 www.stantec.com
CITY OF RENTON
1055 SOUTH GRADY WAY
RENTON, WASHINGTON 98057
JOHN HOBSON
JOE STOWELL
CONTACTPERSONNEL
PROJECT MANAGER
WASTEWATER UTILITY
MANAGER
EMERGENCY
ONE CALL
(425) 430-7279
(425) 430-7212
911
1-800-424-5555
SHEET INDEX
Sheet
Number
Sheet Title
1
COVER SHEET
2
GENERAL NOTES & LEGEND
3
EXISTING SITE PLAN & TREE REMOVAL STA. 1+00 - 8+20
4
EXISTING SITE PLAN & TREE REMOVAL STA. 8+20 - 15+20
5
EXISTING SITE PLAN & TREE REMOVAL STA. 15+20 - 22+20
6
EXISTING SITE PLAN & TREE REMOVAL STA. 22+20 - 29+20
7
EXISTING SITE PLAN & TREE REMOVAL STA. 29+20 - 31+00
8
EROSION CONTROL PLAN STA. 1+00 - 8+20
9
EROSION CONTROL PLAN STA. 8+20 - 15+20
10
EROSION CONTROL PLAN STA. 15+20 - 22+20
11
EROSION CONTROL PLAN STA. 22+20 - 29+20
12
EROSION CONTROL PLAN STA. 29+20 - 31+00
13
HORIZONTAL CONTROL STA 1+00 - 4+60
14
HORIZONTAL CONTROL STA. 4+60 - 8+20
15
HORIZONTAL CONTROL STA. 8+20 - 11+80
16
HORIZONTAL CONTROL STA. 11+80 - 15+20
17
HORIZONTAL CONTROL STA. 15+20 - 18+60
18
HORIZONTAL CONTROL STA. 18+60 - 22+20
19
HORIZONTAL CONTROL STA. 22+20 - 25+60
20
HORIZONTAL CONTROL STA. 25+60 - 29+20
21
HORIZONTAL CONTROL STA. 29+20 - 31+00
22
EX. ACCESS IMPROVEMENTS STA. 1+80 - 4+60
23
EX. ACCESS IMPROVEMENTS STA. 4+60 - 8+20
24
EX. ACCESS IMPROVEMENTS STA. 8+20 - 11+80
25
EX. ACCESS IMPROVEMENTS STA. 11+80 - 15+20
26
EX. ACCESS IMPROVEMENTS STA. 15+20 - 18+60
27
EX. ACCESS IMPROVEMENTS STA. 18+60 - 22+20
28
EX. ACCESS IMPROVEMENTS STA. 22+20 - 25+60
29
EX. ACCESS IMPROVEMENTS STA. 25+60 - 29+20
30
EX. ACCESS IMPROVEMENTS STA. 29+20 - 31+00
31
SEWER PLAN AND PROFILE STA 1+00 - 4+60
32
SEWER PLAN AND PROFILESTA. 4+60 - 8+20
33
SEWER PLAN AND PROFILE STA. 8+20 - 11+80
34
SEWER PLAN AND PROFILE STA. 11+80 - 15+20
35
SEWER PLAN AND PROFILE STA. 15+20 - 18+60
36
SEWER PLAN AND PROFILE STA. 18+60 - 22+20
37
SEWER PLAN AND PROFILE STA. 22+20 - 25+60
38
SEWER PLAN AND PROFILE STA. 25+60 - 29+20
39
SEWER PLAN AND PROFILE STA. 29+20 - 31+00
40
GRAVEL PATH CROSS -SECTIONS STA. 1+00 - 4+50
41
GRAVEL PATH CROSS -SECTIONS STA. 5+00 - 7+50
42
GRAVEL PATH CROSS -SECTIONS STA. 8+00 - 11+00
43
GRAVEL PATH CROSS -SECTIONS STA. 11+50 - 13+00
44
GRAVEL PATH CROSS -SECTIONS STA. 13+50 - 16+00
45
GRAVEL PATH CROSS -SECTIONS STA. 16+50 - 20+00
46
GRAVEL PATH CROSS -SECTIONS STA. 20+20 - 24+50
47
GRAVEL PATH CROSS -SECTIONS STA. 25+00 - 28+50
48
GRAVEL PATH CROSS -SECTIONS STA. 29+00 - 30+50
49
TESC DETAILS
50
TESC DETAILS
51
TESC DETAILS
52
CITY STANDARD DETAILS
53
MISCELLANEOUS DETAILS
54
W1.0 OF 15 - PROJECT OVERVIEW
55
W2.0 OF 15 - PLANTING PLAN & LOG PLACEMENT (1 OF 7)
56
W2.1 OF 15 - PLANTING PLAN & LOG PLACEMENT (2 OF 7)
57
W2.2 OF 15 - PLANTING PLAN & LOG PLACEMENT (3 OF 7)
58
W2.3 OF 15 - PLANTING PLAN & LOG PLACEMENT (4 OF 7)
59
W2.4 OF 15 - PLANTING PLAN & LOG PLACEMENT (5 OF 7)
60
W2.5 OF 15 - PLANTING PLAN & LOG PLACEMENT (6 OF 7)
61
W2.6 OF 15 - PLANTING PLAN & LOG PLACEMENT (7 OF 7)
62
W3.0 OF 15 - PLANT SECHEDULE
63
W3.1 OF 15 - PLANT NOTES & DETAILS
64
W4.0 OF 15 - SITE PREPARATION
65
W5.0 OF 15 - ANCHORED LARGE WOODY DEBRIS PLAN
66
W5.1 - ANCHORED LARGE WOODY DEBRIS NOTES & DETAILS
67
W6.0 - TEMPORARY BYPASS PLAN
68
W7.0 - MITIGATION NOTES
Stantec was not present on site during construction. These
record drawings are a compilation of a copy of the sealed
engineering drawings for this project, as modified by information
furnished by the as -built survey on the project. The information
shown on the record drawings that was provided by the City
Utilities Dept. inspector cannot be verified for accuracy or
completeness. The original sealed drawings are on file at the
offices of the City of Renton.
(RECORD DRAWING
S-392101