Loading...
HomeMy WebLinkAboutR-431006SW 114 SECTION 32, TOWNSHIP 24 N, RANGE 5 E, W.M. C) co I I � � N N � , I I o ry W Z J Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) L. PIED �O of WAS R 232sq ASS/OG 2� NAL 150 145 140 130 125 10+80 KENN YDA L E LOTS (PR/ VA TE) W/ 10 LF \ DISPERSION TRENCH RIM f 149. 00 (MATCH FG) CAP 6" IE 146.50 R 44 LF PVC SSS O 7.25% 34 LF 6" PVC FROM MAIN TO CO JCE 10 LF 4" PVC AFTER CO;s` JE ®MAIN 134.83'°P 1E ® CO 1JZ28 FI 1E AT CAP 138.00 ` SAN/TARP SEWER STUB CLEANOUT (TYP.); PER COR STD PLAN 406.1 28 LF 6" PVC SD O 2.00% MIN. END IE 14 1. 00 TYPE 1 OR (PR/ VA TE) RIM f 144. 00 6" JE 139.75 FENCE CORN & GATE 0.,•E 10.00' PR/ VA TE STORM WATER DRAINAGE- EASEMENT REMOVE EXIS77NG INSTALL "STORr ASPHALT 77?ANS1770N ADAPTER ON EX. RAMP AND REPLACE FIRE HYDRANT Wl774 LANDSCAPE c, CB 1, EX TYPE 1 CB.�' STA. 11+98.45, 12.06' L .: F' RIM 141.58 p 12" lE IN 136.63 (E) 12" 1E OUT 136.53 (W) W CB (TYPE 1) RIM=141.58' EX SSMH .(W) 12"CPP=136.63 RIM=140.72' IE(E) 12"DI=136.53' 12+ 0 IE(W/SE/E) 8" CONC=132.46' (C.C.) SSL IM=140.72' IE(W/SE/E) 8"GONG=13 - J CB (TYPE 1)" SS 33 LF 12" LCPE O 5.69% (PIIPUBUC) 11 +20 D.R. STRONG CONSUL TING ENGINEERS ENGINEERS PLANNERS SURVEYORS 620 - 7th AVENUE KIRKLAND, WA 98033 O 425 827 3063 F 425.827.2423 11+60 1 8',3"DEC O °° - 8"DEC _ 0 -P- STA. 12+31.81, 12.48' L', RIM 143.53 12" JE IN 138.53 (E) 6" JE IN 139.03 (N) 12" JE OUT 138.53 (W) LSp 9634 u.i ry I ' 89'04'28" WIV 0.68'S 1 nn n ILROAD TIE WA i ON i SHED • I 28-EVG • h I � EAVE O I I GARAGE I I I y✓ FOOTPRINT=407 SF n>WPancSrnl f INSTALLED UNDER SFR BUILDING PERMITS (TYP.) FF CROP COR �81�"EVGTYPE 1 CB 33 ;T ► 32 328 S.F. 5, 328 S.F. \ ............................... r 9 _ (PRIVATE) W/ 10 LF 3. . DISPERSION TRENCH FENC RIM ±151.00 (MATCH FG) 6 /E 148.50 1.4' 34 LF 6" PVC FROM MAIN TO CO 10 LF 4" PVC AFTER CO JE O MAIN 13Z 10 FENCE COR 1E O CO 139.25 lE AT CAP 139.88 1.1'E APPROX. LOCATION OF EX. SIDE --SEWER PER ASBUILTS TO BE CUT AND CAPPED AT PROPERTY LINE 1" WATER SERVICE LINE AND METER TO BE INSTALLED BY CITY FORCES (TYP.); PER COR STD PLAN 320.1 "STA. 12+91.66 16.62' L WET TAP TO EX. 8" WATER MAIN 1-8 x6" TEE (M✓xFL) 1-6" G.V (FLxMJ) 1-FIRE HYDRANT ASS'Y 19 10 LF 6" DI CL. 52 :rl CONCRETE BLOCKING PER STD. PLAN 310.2 LOCA77ON OF EX. 3 " WATER SERVICE TO BE CUT AND CAPPED AT 7HE Rai WA7ER MAIN BY CITY FORCES UNDER 1.Y 4 ` PERMIT B24002199 EX. CB 2, EX TYPE 1 CB SET R Ak/CAP C� AT IOP COI Rl....._... � 0.8'E FROM STA. 13+18.12, 12.66 L d- PROP COR RIM 148.72 " C3ML MNMY 12 /E IN 145.02 (E) �.- P P 6" 1E IN 146.42 (NE) A P - 12" 1E OUT 145.07 (W) - i i-------T --------I- FT 7--- -SD- --� P CB (TYPE,) P P (n?E 1 I 20 3+00 O11._08.y° PUBLIC) (71 N 690 3i tH-ST CB 2 TYPE 1 CB PUBUC - STA. 12+98.44, 12.85' L -- -I RIM 14Z85 'S SS SS - 67 LF 12" LCPE O 6.48% (P2/PUBUC) 12" JE IN 142.85 (E) SI 1,n cn Sp 12" JE OUT 142.85 (W) EX. 400 LF CONC. PIPE AT 5.46% 'GCB (TYPE,) RIM=152.11 • PROVIDE 4X4' CONCRETE SHEAR 12 CONC=149.36 BLOCK PER STD. PLAN 31a2 2 CONC=149.56' 1. 1, CLEARANCE EX. PIPE TO BE BETWEEN WA&SD REMOVED PROVIDE ETHAFOAM EX. PIPE TO BE 2.7' REMOVED CLEARANCE BETWEEN WA&SD 1.2' EX. STRUCTURE CLEARANCE TO BE REMOVED BETWEEN SS&SD PROVIDE ETHAFOAM - -- X. GRADE U - - - EX. CB 2, EX E 1 G -- i STA. 13+18.1$ 12.66' L RIM 148.72 -- - 12" 1E /N 145.02 (E) " lE /N 1 4 i i STA. 11+98.45, 12.06' L RIM 141.58 12" JE l�I 136.63 (E) 12" 1E 0 T 136.53 (W) 1.0' CLEARANCE - BETWEEN WA&SD PROVIDE E7HAF0AM 33 LF 12" LCPE O 5.69% P1 UBLIC) - STA. 12+31.81, 12.48' L RIM 143.53 12" 1E IN 136.53 (E) 6" IE IN 139.03 (N) 12" JE OUT 138.53 (W) N34THST O 12+00 1 1 CITY COMMENTS (DATED 07.19.24) 2 ICITY COMMENTS (DATED 09.06.24) N0. REVISION 12+40 42 12" JE OUT 145.07 (W) 20 LF 2" LCPE O 11.28% (P31PUBL/C) CB 2 TYPE 1 CB PUBUC 8.44, _12.85' L RIM 147.85 12" JE IN 142.85 (E) 12" JE OUT 142.85 (W) 1.5, CLEARANCE BETWEEN WA&SD 67 LF 12" LCPE O 6.48% P2 UBL/C) 1.9' CLEARANCE BETWEEN SS&SD CLEARANCE BETWEEN SS&SD � � w 12+80 BD 08.13.24 YLP SURVEYED: TERRANE BD 09.17.24 YLP DESIGNED: BD DRAWN: ECM CHECKED: YLP BY DATE APPR APPROVED: YLP 13+20 13+60 SCALE: VERTICAL: NAVD 1988 AS NOTED HORIZONTAL: NAD 1983/1991 ONE INCH DATUM AT FULL SCALE DATUM IF NOT ONE INCH SCALE ACCORDINGLY 145- NORTH GRAPHIC SCALE 0 10 20 40 1 INCH = 20 FT. HORIZONTAL 0 2.5 5 10 1 INCH = 5 FT VERTICAL C TY OF RENTON U'R Planning/Building/Public Works Dept. NO TES: 1. ALL TRENCH RESTORATION WITHIN THE CITY OF RENTON RIGHT OF WAY SHALL BE PER THE CURRENT CITY OF RENTON TRENCH RESTORATION AND STREET OVERLAY DETAIL. 2. WET TAPPING OF EXISTING WATER MAIN SHALL BE PERFORMED BY CITY WET TAPPING CONTRACTORS AT DEVELOPER'S EXPENSE. SIDE SEWER NOTES: O N C:)APPROVED O �! U 1. SIDE SEWER LINES SHALL BE INSTALLED A MINIMUM OF 8 FEET INTO EACH LOT. 2. MINIMUM SIDE SEWER SLOPE IS 2.00% J. MINIMUM SIDE SEWER DEPTH IS 5 FEET FROM FINISHED FLOOR. 4. IN UNPAVED AREAS, POUR 2-FOOT SQUARE CONCRETE (CLASS 3000) PAD AROUND CLEANOUT RING AND COVER BASIC DISPERSION NOTE.. EACH DISPERSION TRENCH HAS A LENGTH OF 10 FT AND SHALL MITIGATE 700 S.F. OF ROOF AREA. FINAL DESIGN TO BE PROVIDED ON BUILDING PERMIT PLANS. CATCH BASIN NOTE: IF DURING CONSTRUCTION, IT IS FOUND THAT PIPE ANGLES REQUIRE ROTATION OF Q THE TYPE 1 CB AND MISALIGNMENT WITH THE CURB, THE CITY WILL REQUIRE REMOVAL AND REPLACEMENT OF TYPE 1 CB WITH LARGER STRUCTURE AND J ADEQUATE KNOCKOUT. PUBLICLY MAINTAINED STORM ELEMENTS: ALL CONVEYANCE SYSTEM ELEMENTS DEPICTED ARE PRIVATE UNLESS LABELED AS PUBLIC. WATER METER NOTE: A SEPARATE WATER PERMIT WILL BE REQUIRED, AND WILL BE PREPARED BY CITY STAFF AT TIME OF CIVIL PERMIT ISSUANCE. C) C) `D N I S- 431001 W- 431001 R- 431006 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING v SURFACE WATER UTILITY LHHuynh 09/27/2024 Farah 09/27/2024 C) (n WASTEWATER UTILITY WATER UTILITY jstowel 109/27/2024 ABDOUL GAFOUR 09/27/2024 J DATE: KENNYDALE LOTS 2/13/2024 C)` 1ELDB PAGE: COMPOSITE UTILITY PLAN OOK: / PAGE: 7 DRAWING 1116 N 34TH ST C 6 Lz RENTON, WASHINGTON 98056 SHEET: 6 OF:9 Y DRS PROJECT NO. 24010