HomeMy WebLinkAboutMFP24004576.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP24004576
IVR Number: 24004576
Permit Information
Permit Name: A.3038478
Address/Location:09/09/2024Application Date:7841300175Parcel Number: 450 SHATTUCK AVE S
Permit Type:10/09/2024Issue Date:Franchise
Permit Work Class:10/09/2025Expiration Date:Minor Utility
Job Number: A.3038478Franchise Type:Telephone
Description: Century Link to access MH 195, HH UN58 and HH UN60 to splice new fibers to exiting fiber cables.
Contacts
Name Address PhoneTypeBilling
Nathan Macleod
Lumen
7850 S Trafton St, Bldg B
Tacoma, WA 98409
C: (253) 583-6283ApplicantX
Cheyenne Classen
North Sky Communications
2112 97th Ave E
Tacoma, WA 98444
Contact
Michael Smith
North Sky Communications
21320 84th Ave S
Kent, WA 98032
C: (206) 305-5881Contractor
Business License Number: 36846Construction Contractor: NORTHSC857Q4
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
QWest/Century Link - Billing 23315 66th Ave S
Kent, WA 98032
Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 10/27/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 10/27/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐ Electronic Copy of the TCP Application
☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
Include map(s) showing the location of the project and work area.
Be legible lettering and clear, contrasting, symbols of viewing or printing.
Must indicate street names, and north arrow and scale.
Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
A.3038478 MFP24004576
450 Shattuck Ave S
10/14 10/25 9 AM 5 PM
North Sky Communications
Nathan Macleod 2535836283
7850 S Trafton ST Bldg B Tacoma/WA 98409
Century Link to access MH 195, HH UN58 and HH UN60 to splice new fibers to
exiting fiber cables.
Monday Friday 3:00pm8:00am
Scott Warlick CED 10/9/2024
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 10/27/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
Must have approved Traffic Control Plan (TCP) prior to commencing the work.
Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
Comply with all traffic regulations of the City of Renton and the State of Washington.
Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends
and holidays) prior to starting any work.
Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum
of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a
temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a
minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140
with any questions.
Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
All permit conditions shall be met.
NOTES:
Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
Approved Temporary Traffic Control Plan must be at the work site during work hours.
Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 10/27/2021
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
10/01/2024
Nathan Macleod
SHATTUCK AVE SDWYDWYS 2ND AVES 2ND AVE ONE WAY
ONE WAYONE WAYONE WAY
WHITWORTH AVE SMORRIS AVE SLAKE AVE STRAFFIC CONTROL PLANJOB # A.3038478PERMIT #
Date:9/8/2024 Author:JORGIA DURR Project:A.3038478DRAFTED FOR LUMEN:(DO NOT ALTER)Comments: General Requirements1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by City, County, and/or WSDOT
LegendMANHOLESSPOTTERWORK TRUCKCONESArrowboard (Chevron)Work Area
NOT TO SCALE
N
MERGING DEVICES DEVICESSHIFTING12 FEETL1/2 L
770
6 6810161519
345599999
711
11
181820
406075225250275
115 115165295495550605660715
85150305330370385
MERGING DEVICES DEVICESSHIFTING11 FEETL1/2 LMERGINGDEVICESDEVICESSHIFTING10 FEETL1/2 L
6666
33344
77
2025303540455055606570
2535507015090170185200220200
DEVICESLENGTHMPHSHOULDER TAPERSASSUMES 10' SHOULDER2025303540455055606570
MPHLANEWIDTH
70065060055050045027020515010570 668810161614151719
355575105135225250275300325350
68810
3455999 660600
80125180245320540720780840
61016191997
182221
12 4065
300330
90125160270360390420
1010
34556991112 SHOULDER TAPERSHOULDER WIDTH x SPEED / 3(EXTRACTED FROM APPENDIX 1-1, OF THE WORK ZONE TRAFFIC CONTROL GUIDELINES- M54-44, 2012)
ONE LANE TWO WAY TAPER 50' MIN / 100' MAXTAPER/ CHANNELIZING DEVICE TABLEMERGING, SHIFTING, AND SHOULDER TAPER LENGTHS AND NUMBER OF CHANNELIZATION DEVICES USED(WASHINGTON STATE DEPARTMENT OF TRASPORTATION)(ALL MINIMUMS)
RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTSURBAN STREETS(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
50 / 65 MPH45 / 55 MPH35 / 40 MPH25 / 30 MPH25 MPH OR LESS
800' +/-500' +/-200' +/- (2)100' +/- (2)350' +/-SIGN SPACING = X (1)
CHANNELIZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 40'40'30'20'80'60'ONE LANE TWO WAY TTC ZONE TAPER 20'TANGENT 40' SPACING AT ALL SPEEDS UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:JORGIA DURR, TCS # ES2 000149, jd.durr@outlook.com
Drafted: 9/8/2024Jorgia DurrTCS # ES2 000149TCS #Exp.3/31/2027Phone 253-737-5198jd.durr@outlook.com_______________________Jorgia Durr
SPEED LIMIT30
SMH 195
WORK AREA11' X 170'
ROADWORKAHEADRIGHT LANECLOSEDAHEADSIDEWALKCLOSEDSIDEWALK CLOSEDAHEADCROSS HERE SIDEWALK CLOSEDAHEADCROSS HERES 2ND AVE @ SHATTUCK AVE SMH 195 ACCESSRIGHT LANE CLOSURE
ROADWORKAHEADRIGHT LANECLOSEDAHEAD
XXX
Comments: THIS IS TO ACCESS MH 195THIS IS A RIGHT LANE CLOSURESIDEWALK CLOSED AT WORK AREAPEDESTRIANS DETOURED AT SHATTUCK AVE S AND LAKE AVE SSPOTTER WILL ASSIST PEDESTRIANS AT WORK AREADRIVEWAYS WILL REMAIN ACCESSIBLE AT WORK AREAREFER TO CHARTS FOR SIGN SPACING, DEVICE SPACING AND TAPER LENGTHS
L
www.invarion.com
MFP24004576
S 3RD PL
S 3RD ST
SHATTUCK AVE SWHITWORTH AVE SS 3RD STSHATTUCK AVE S @ S 3RD PLHH UN58 ACCESSSHOULDER WORK TRAFFIC CONTROL PLANJOB # A.3038478PERMIT #
Date:9/8/2024 Author:JORGIA DURR Project:A.3038478DRAFTED FOR LUMEN:(DO NOT ALTER)Comments: General Requirements1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by City, County, and/or WSDOT LegendWORK TRUCKCONESHANDHOLEWork AreaSSPOTTER
NOT TO SCALE
N
MERGING DEVICES DEVICESSHIFTING12 FEETL1/2 L
770
6 6810161519
345599999
711
11
181820
406075225250275
115 115165295495550605660715
85150305330370385
MERGING DEVICES DEVICESSHIFTING11 FEETL1/2 LMERGINGDEVICESDEVICESSHIFTING10 FEETL1/2 L
6666
33344
77
2025303540455055606570
2535507015090170185200220200
DEVICESLENGTHMPHSHOULDER TAPERSASSUMES 10' SHOULDER2025303540455055606570
MPHLANEWIDTH
70065060055050045027020515010570 668810161614151719
355575105135225250275300325350
68810
3455999 660600
80125180245320540720780840
61016191997
182221
12 4065
300330
90125160270360390420
1010
34556991112 SHOULDER TAPERSHOULDER WIDTH x SPEED / 3(EXTRACTED FROM APPENDIX 1-1, OF THE WORK ZONE TRAFFIC CONTROL GUIDELINES- M54-44, 2012)
ONE LANE TWO WAY TAPER 50' MIN / 100' MAXTAPER/ CHANNELIZING DEVICE TABLEMERGING, SHIFTING, AND SHOULDER TAPER LENGTHS AND NUMBER OF CHANNELIZATION DEVICES USED(WASHINGTON STATE DEPARTMENT OF TRASPORTATION)(ALL MINIMUMS)
RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTSURBAN STREETS(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
50 / 65 MPH45 / 55 MPH35 / 40 MPH25 / 30 MPH25 MPH OR LESS
800' +/-500' +/-200' +/- (2)100' +/- (2)350' +/-SIGN SPACING = X (1)
CHANNELIZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 40'40'30'20'80'60'ONE LANE TWO WAY TTC ZONE TAPER 20'TANGENT 40' SPACING AT ALL SPEEDS UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:JORGIA DURR, TCS # ES2 000149, jd.durr@outlook.com
Drafted: 9/8/2024Jorgia DurrTCS # ES2 000149TCS #Exp.3/31/2027Phone 253-737-5198jd.durr@outlook.com_______________________Jorgia Durr
HH UN58 WORK AREA8' X 30'NOPARKINGFROMTOTOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555
ROADWORKAHEAD
SIDEWALK CLOSEDAHEADCROSS HERESIDEWALK CLOSEDAHEADCROSS HERESIDEWALKCLOSED
ROADWORKAHEADSHOULDERWORKROADWORKAHEADX
X
X
S
X
SPEED LIMIT25
Comments: THIS IS TO ACCESS HH UN58THIS IS SHOULDER WORKSIDEWALK CLOSED AT WORK AREAPEDESTRIANS DETOURED AT S 3RD ST AND S 3RD PLSPOTTER WILL ASSIST PEDESTRIANS AT WORK AREADRIVEWAYS WILL REMAIN ACCESSIBLE AT WORK AREAPARKING RESTRICTED AT WORK AREAREFER TO CHARTS FOR SIGN SPACING, DEVICE SPACING AND TAPER LENGTHS
www.invarion.com
MFP24004576
DWYDWYSHATTUCK AVE SSHATTUCK AVE S
S 4TH PL
HOUSER WAY S S 4TH STTRAFFIC CONTROL PLANJOB # A.3038478PERMIT #
Date:9/8/2024 Author:JORGIA DURR Project:A.3038478DRAFTED FOR LUMEN:(DO NOT ALTER)Comments: General Requirements1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by City, County, and/or WSDOT LegendHANDHOLEWORK TRUCKCONESWork AreaSSPOTTER
NOT TO SCALE NMERGING DEVICES DEVICESSHIFTING12 FEETL1/2 L
770
6 6810161519
345599999
711
11
181820
406075225250275
115 115165295495550605660715
85150305330370385
MERGING DEVICES DEVICESSHIFTING11 FEETL1/2 LMERGINGDEVICESDEVICESSHIFTING10 FEETL1/2 L
6666
33344
77
2025303540455055606570
2535507015090170185200220200
DEVICESLENGTHMPHSHOULDER TAPERSASSUMES 10' SHOULDER2025303540455055606570
MPHLANEWIDTH
70065060055050045027020515010570 668810161614151719
355575105135225250275300325350
68810
3455999 660600
80125180245320540720780840
61016191997
182221
12 4065
300330
90125160270360390420
1010
34556991112 SHOULDER TAPERSHOULDER WIDTH x SPEED / 3(EXTRACTED FROM APPENDIX 1-1, OF THE WORK ZONE TRAFFIC CONTROL GUIDELINES- M54-44, 2012)
ONE LANE TWO WAY TAPER 50' MIN / 100' MAXTAPER/ CHANNELIZING DEVICE TABLEMERGING, SHIFTING, AND SHOULDER TAPER LENGTHS AND NUMBER OF CHANNELIZATION DEVICES USED(WASHINGTON STATE DEPARTMENT OF TRASPORTATION)(ALL MINIMUMS)
RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTSURBAN STREETS(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
50 / 65 MPH45 / 55 MPH35 / 40 MPH25 / 30 MPH25 MPH OR LESS
800' +/-500' +/-200' +/- (2)100' +/- (2)350' +/-SIGN SPACING = X (1)
CHANNELIZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 40'40'30'20'80'60'ONE LANE TWO WAY TTC ZONE TAPER 20'TANGENT 40' SPACING AT ALL SPEEDS UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:JORGIA DURR, TCS # ES2 000149, jd.durr@outlook.com
Drafted: 9/8/2024Jorgia DurrTCS # ES2 000149TCS #Exp.3/31/2027Phone 253-737-5198jd.durr@outlook.com_______________________Jorgia Durr
SPEED LIMIT25
S
WORK AREA8' X 50'
HH UN60
SHOULDERWORK
SHOULDERWORKROADWORKAHEAD
ROADWORKAHEAD
ROADWORKAHEAD
NOPARKINGFROMTOTOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555
X
X
X X
X
SHATTUCK AVE S @ S 4TH PLHH UN60 ACCESSSHOULDER WORK Comments: THIS IS TO ACCESS HH UN60THIS IS SHOULDER WORKSIDEWALK IS ACCESSIBLE AT WORK AREASPOTTER WILL ASSIST PEDESTRIANS AT WORK AREADRIVEWAYS WILL REMAIN ACCESSIBLE AT WORK AREAPARKING RESTRICTED AT WORK AREAREFER TO CHARTS FOR SIGN SPACING, DEVICE SPACING AND TAPER LENGTHS
www.invarion.comMFP24004576
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE:WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.00000000”NVICINITY MAPFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMSCOPE OF WORK:IN MH 195, SPLICE LRE28, 39-40 FROM EXISTING FIBER CABLE [TDA0] TO EXISTING FIBER CABLE [A3KWF]. IN HH UN58,SPLICE FROM EXISTING FIBER CABLE [A3KWF] TO EXISTING FIBER CABLE [A3KWC]. IN HH UN-60, SPLICE FROM EXISTINGFIBER CABLE [A3KWC] TO EXISTING FIBER CABLE [A3GCR]. USE ENTRANCE FACILITIES TO TERMINATE FIBERS TO THE FDP.TEST FIBERS END TO END.DRAFTED BY: MOUNTAIN LTD/DL - 08/30/2423N4E24A.3038478W26226RNTNWA01450 SHATTUCK AVE SRENTON, WA 9805715FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400RMFP24004576
TTEE CATV CATV CATV GG TS TS WW S S SD SD IRRIG IRRIG C/L C/L R/W R/W R/W P/L P/L
B/C B/C B/C EOP EOP TTTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'XITEM #STATIONPSEPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHERITEM#STAHT-CL-YRXX'-X"POLE#MAKE READYEXISTING ATTACHMENTSNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF RNGE:SECT:TOWN:GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400FIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMDRAFTED BY: MOUNTAIN LTD/DL - 08/30/2423N4E24A.3038478W26226RNTNWA01450 SHATTUCK AVE SRENTON, WA 9805725RMFP24004576
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSNOTE:IN MH 195, SPLICE LRE28, 39-40 FROM EXISTING FIBERCABLE [TDA0] TO EXISTING FIBER CABLE [A3KWF].FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400 R/W R/W EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W T R/W 6'24'25'46'40'#0007200188315#7841800085400#000720006010' S/WFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMDRAFTED BY: MOUNTAIN LTD/DL - 08/30/2423N4E24A.3038478W26226RNTNWA01450 SHATTUCK AVE SRENTON, WA 9805735RSPEEDLIMITSPEEDLIMITMFP24004576
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSNOTE:IN HH UN58, SPLICE FROM EXISTING FIBERCABLE [A3KWF] TO EXISTING FIBER CABLE[A3KWC].FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400#0007200132 EOP EOP EO
P
R/W R/W R/W R/W R/W
EOP EOP
EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W
R/W R/W R/W R/W R/W R/W R/W R/W T2'6'6' S/W10' S/W24'35'30'32'21'301#7841300020212#0007200115300#0007200157FIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMDRAFTED BY: MOUNTAIN LTD/DL - 08/30/2423N4E24A.3038478W26226RNTNWA01450 SHATTUCK AVE SRENTON, WA 9805745RSPEEDLIMITSPEEDLIMITMFP24004576
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSNOTE:IN HH UN-60, SPLICE FROM EXISTING FIBER CABLE [A3KWC] TOEXISTING FIBER CABLE [A3GCR]. USE ENTRANCE FACILITIES TOTERMINATE FIBERS TO THE FDP. TEST FIBERS END TO END.FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400440#1823059118 EOP EOP EOP EOP R/W R/W
R/W
R/W R/W R/W EOP EOP
EOP EOP EOP
EOP EOP EOP EOP
R/W R/W R/W R/W
R/W R/W
R/W R/W R/W R/W R/W R/W R/W R/W
T12'2'20'40'29'29'35'25'36'241#9228900070450#7841300175FIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMDRAFTED BY: MOUNTAIN LTD/DL - 08/30/2423N4E24A.3038478W26226RNTNWA01450 SHATTUCK AVE SRENTON, WA 9805755RSPEEDLIMITSPEEDLIMITMFP24004576