Loading...
HomeMy WebLinkAboutR-417605i 0 � cfl � r � T N N CD J 73 O z Q U) Q m LEGEND: FOUND MONUMENT AS NOTED FOUND CORNER MONUMENT AS NOTED PROPERTY LINE PROPERTY CORNER ROAD SIGNAGE POWER JUNCTION BOX, SIZE VARIES CABLE JUNCTION BOX, SIZE VARIES TELEPHONE JUNCTION BOX, SIZE VARIES LIGHT POLE WITH ARM WATER METER WATER VALVE FIRE HYDRANT STORM DRAIN CATCH BASIN STORM DRAIN MANHOLE SANITARY SEWER MANHOLE O TELEPHONE MANHOLE WC`- WOOD FENCE CD CHAINLINK FENCE C. DECIDUOUS TREE EVERGREEN TREE - SANITARY SEWER LINE - - - - - STORM LINE [D - UNDERGROUND POWER UNDERGROUND WA TER UNDERGROUND GAS UNDERGROUND TELEPHONE UNDERGROUND CABLE EDGE OF PA VEMEN T FENCE CONCRETE ROOF AND FOOTING DRAIN NOTE: ALL ROOF DOWNSPOUTS AND FOOTING DRAINS WILL BE CONNECTED TO CATCH BASIN 1 VIA THE PROPOSED STORM STUB SHOWN ON THE PLANS. EXISTING SANITARY SEWER SERVICE NOTE: CONDITION OF EXISTING STUB AND SIDE SEWER LATERAL TO BE EVALUATED PRIOR TO CONSTRUCTION AND IF DETERMINED TO BE DEFICIENT WILL REQUIRE REPLACEMENT BACK TO THE MAN. WATER MAIN CONSTRUCTION NOTES: 1. EXISTING WATER SERVICES ALONG WELLS AVENUE S BETWEEN S 2ND STREET AND THE PROJECT SITE SERVED BY THE EXISTING 6" WATER MAIN WILL BE TRANSFERRED TO THE NEW 12" WATER MAIN UPON COMPLETION. THE NEW 12" WATER MAIN MUST BE INSTALLED, TESTED, AND ACCEPTED PRIOR TO TRANSFER OF SERVICES. 2. CITY CREWS WILL COMPLETE THE TRANSFER OF SERVICES INCLUDING INSTALLATION OF NEW SERVICE LINES, METER SETTER/BOXES, AND RESTORATION OF STREET CROSSINGS ASSOCIATED WITH THE NEW SERVICE LINES. CONTRACTOR IS RESPONSIBLE FOR STREET RESTORATION ASSOCIATED WITH THE WATER MAIN CONSTRUCTION. 3. SERVICES WILL BE TRANSFERRED FOR THE FOLLOWING PARCELS: 7251501090 (126 WELLS AVE S), 7231502020 (123 WELLS AVE S), 0007200085 (122 WELLS AVE S), 0007200091 (118 WELLS AVE S). 4. CITY CREWS WILL ABANDON THE EXISTING 6" WATER MAIN FOLLOWING THE TRANSFER OF SERVICES TO THE NEW 12" WATER MAIN. 5. ALL FITTINGS AND VALVES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAVE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 6. CONCRETE THRUST BLOCKS REQUIRED ON ALL FITTINGS PER COR STANDARD PLANS 330.2 AND 330.3. 7 CONTRACTOR TO POTHOLE ALL UTILITY CROSSINGS TO IDENTIFY CONFLICTS WITH NEW WATER MAIN PRIOR TO CONSTRUCTION. CONTRACTOR TO PROMPTLY NOTIFY CITY OF ANY CONFLICTS. 8. CONTRACTOR TO POTHOLE EXISTING SIDE SEWERS CROSSING NEW WATER MAIN PRIOR TO BEGINNING CONSTRUCTION OF WATER MAIN. DEPTH AND ELEVATION AT THE TOP OF SIDE SEWER AND AVAILABLE CLEARANCE TO NEW WATER MAIN SHALL BE PROVIDED TO CITY. IF AVAILABLE CLEARANCE IS LESS THAN 18 INCHES BUT GREATER THAN 6 INCHES, WATER MAIN SHALL BE INSTALLED WITH CDF PIPE ENCASEMENT EXTENDING 10' ON BOTH SIDES OF CROSSING. IF AVAILABLE CLEARANCE TO NEW WATER MAIN IS LESS THAN 6 INCHES, SIDE SEWER SHALL BE REPLACED TO PROVIDE 18 INCHES OF CLEARANCE FROM NEW WATER MAIN IN ACCORDANCE WITH CITY OF RENTON STANDARD PLAN 406.1 IF SIDE SEWER REPLACEMENT IS REQUIRED, CONTRACTOR SHALL SUBMIT A DESIGN OF THE NEW SIDE SEWER TO THE CITY FOR APPROVAL PRIOR TO CONSTRUCTION. 9. WITH 90' BEND EXISTING 6" LINE WILL BE DECOMMISSIONED. THRUST BLOCK WILL LIKELY EXTEND INTO SIDEWALK AREA AND MAY REQUIRE REMOVAL OF CURB/GUTTER/SIDEWALK FOR INSTALLATION. PROVIDE APPLICABLE NOTES AND DETAILS ON HOW THIS AREA WILL BE CONSTRUCTED. r Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) 7J A NW 114 SECTION 17, TOWNSHIP 23 N, RANGE 5 W, W.M. BA SSA NO MUL TAFAMIL STA, 3+01. 04 , 5.5' R 1-12 x6 TEE FLxFL 1-6" GATE VALVE (FLxMJ) j, 1-12" GATE VALVE (FLXMJ) 1-12" ADAPTER (FLxMJ) W/ CONCRETE THRUST BLOCKING 1-12" PIPE SPOOL o I II 1-12" POLYPIG STATION PER S7D. NO PLAN 300.7 SHACKLE E, VALVE TODEAD MAN BLOCK NEW 4" DDCV FIRE I I (SEE SHEET C12) SPRINKLER ASSEMBLY W II ((INSTALLDEADMAN BLOCK TO STANDPIPE OUTSIDE _ _ - - RESTRAINT VALVE AND 7EE) CONNEC7ION PER STD. STA. 3+01.06 17.95' R PLANTER COR PLAN 370.3 I I (SEE DETAIL SHEET C13 ) a ° CUT /N CONNECTION BY CITY FORCES TO USE CUT I VAL VIES R1). NEW 1.5" WATER SERVICE AND WA7FR METER W DCVAI 5 LIMITS OF HALF I COR S7D. PLANE300 2 (SEE SHEET CO 1-6 z6" 7EE (FLxFL) W/ BEHIND ME1FR PER STREET GRIND AND OVERLAY (TYP.) I I CONCRETE THRUST BLOCKING COR STD. D7L. 320.2 & 340.8 (SEE DETAIL SHEET C11) 1A/ W 2-6" GATE VALVES (FLxMJ) 3-6" DI SPOOL (LF AS REQ.) _ _ \ COVERED PATIO \ ° I 1 3-6 SOLID SLEEVE (ma) (INSTALL DEAD MAN BLOCK AND END CAP N88�4'50"W 120.09' � I I _ _ (MJ) ON EXIS77NG 6" Wi47ER MAIN TO " 40- ---- -- - - - ---__--_-__- -- - - � I I RESTRAIN NEW 90' BEND) J PROPOSED CO 1, TYPE 1 6'r DI CL. 52 I 12 LF 6" DI CL. 52 o UNCOVERED MUL Tl-FAMIL Y STA. 2+70.67, 19.05' L 15' WATER UTILITY 4 W SOLID SLEEVE p Its)_ BALCONY (TYP.) STRUCTURE RIM 39.67 EASEMENT I II / STA. 2+90.44, 5.5' R - 6" lE IN 37.48 (W) I 1-6 x12 7EE MJxFL W CONCRETE BLOCK/N LOWER FF = 40.00' 8" /E OUT 37.48 (E) f 6" I I 1-6" GATE VALVE (FLxMJ) SDCO' l C 52 1 1-DDCV FIRE SPRINKLER ASS'Y PER COR S7D. 0 0 58 LF 6" PVC SEWER I 3 - + 9 04 PLAN 350.3 AND 370.3 STUB ® 2.00% MIN. SLOPE 5'xl4' i (SEE DETAIL SHEET C13) o LOBBY GRAD CO VERED DR/ VEW4Y AREA T d a --32 LF 8" D.I. ° ® 1.03% (P3) J WA 7ER S R VICE LINE TO BE 2 ; PROPOSED YARD DRAIN WHICH WILL a Q a a 12' PROPOSED I I CONNECTED TO NEW 12" WATER MAIN _ CONNECT TO THE EXIS77NG SEWER MAIN (A � O R N :E S SID WALK Wlq T I i I I I 12 LF 12" D/ CL. 52 LOW POINT EL. ® RIM = 39.75 PVC STORM STUB ° ° I CS 2, TYPE -______ - - - - - _ - _ _°_ _° ° ..16" ■ `: - -- I 275' R.O. W II (SADDLE EXIS77NG STORM MAIN) ------ ------ I--------- _ _ ------ -- DEQICA TION - I I I I 341' R -- 41--------- -------- II RIM 39.77 )OF LINE FOR OVERHANG a __ _ " a W. ` a - " as / " 8 /E IN 37.15 OVER DRI VEWA Y ACCESS TO RESIDENCES G A R A G E ° 15 LF TRENCH DRAIN TO I / f I � �I I 6.2 EX. 12" lE IN 36.27 (S) COLLECT RUN-OFF FROM EX. 12 /E OUT 36.27 (N) f UNCOVERED DRI VEWA Y AREA I I I� ° LARGE CAPACITY OIL INTERCEPTOR CLEAN OUT TO BE PROVIDED AT 77E /N TO EXIS77NG 6 PVC SANITARY SEWER a I I I I \ STA. 2+7. 91' 5.50' R 1-6 x12 1FE (MJxFL W/ TO BE PROVIDED AT 77-1/S CO STUB, • CON7RACTOR TO VERIFY lE OF (SEE DETAIL SHEET C10) I "4 I CONCRETE BLOCKING EXIS77NG STUB AND ENGINEER TO VERIFY 1 1 i I I 1-6" GATE VALVE (FLxMJ) SLOPE WILL MEET MIN/MUM STANDARDS a 1-FIRE HYDRANT ASS'Y SSCO TYP. I i I I PER COR STD. PLAN INSTALL 1" SERVICE LINE WITH 6y D I I I I 310.1, 310.2 AND 310.3 SINGLE /" IRRIGA77ON METER AND ( ° (SEE DETAIL SHEET C12) DCVA ASSEMBL Y BEHIND METER ° I I I I I 12 LF 12" D/ CL. 52 (COR STD PLAN 320.1 & 340.8) / 2.5 x 3 WA 7FR EASEMENT i j WATER SERVICE LINE EXIS77NG 29 LF 6" I I I I TO BE CONNECTED TO PVC SEWER S1UB i j I I NEW 12" W47ER MAIN STA. 2+6Z 15, 5.5' R I I I a 1-12" GA TE VAL VE MJxMJ I I I I I 210 LF 12" D/ CL. 52 ICLf8. oo' I I I I I f7.8� II � �� II ° _ I O I I I I -------WATER SERVICE LINE N I I TO BE CONNECTED TO NEW 12" W47ER MAIN 0) SSMH Cn RIM=41.26 CL CHANNEL=34.21 cn I SAWCUT PER COR STD. I i DTL. 110.1 (SEE DETAIL SHEET CB) II ' II EX. 6" WA7FR MAIN TO BE ABANDONED /N \ II PLACE I I I I .II I II II ° I I I I II a I I 7 LF 12" Of CL. 52 STA. 0+56.97' 5.50' R I I 1-12 45' BEND (MJ) W/ I I STA. 0+52.18 10.29' R CONCRE7F BLOCKING 1-12" 45-BEND (MJ) W/ I I a CONCRE7F BLOCKING CONNEC77ON TO EX 12" WATER MAIN m` D.R. STRONG CONSUL TING ENGINEERS ENGINEERS PLANNERS SURVEYORS 620 - 7th AVENUE KIRKLAND, WA 98033 0425.8273063 F 425.827.2423 1 CITY COMMENTS O4.16.21 YLP 2 CITY COMMENTS 7.3.24 YLP 3 CITY COMMENTS 9.10.24 YLP N0. REVISION m CITY FORCES PER COR S7D PLAN 300.4 1-12" SLEEVE (MJ)� \\I 1-DI SPOOL (LF AS REQ) N INSTALL 12" POL YPIGGING STA 77ON AT END OF NEW 12" WATER MAIN PER COR 1- S7D PLAN 300.7 Z O I � 3 . e N I o 0 o 5.24.24 YLP SURVEYED: DJC 3.23.24 YLP DESIGNED: YLP ?.19.24 YLP DRAWN: GLB CHECKED: YLP DATE APPR APPROVE SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY U REMOVE EX. 6" GA Ti CAP MJ) EX. 6 WA (BY CITY FORCES) Id SDMH RIM=41.47 mw 8"CONC=38.82(N) N O FRT H GRAPHIC SCALE 0 10, 20' 40' 1 INCH = 20 FT. VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM C TY OF RENTON Planning/Building/Public Works Dept. I EG = EG = 40.16 I \ � - ------ L I � � Ia � ° I I jFG=40.14° o �_• J 1. % ° FG=40.19 Q. °1 a a ° DRI VEWA Y TO BE 4 CONSTRUCTED PER a al 8 0 COR STD. DTL. 104.3. I rrcvrv�tu ".1) I I TREE GRA TE =I TC = 40.03 BC 39.53 c� TC = 40.05 BC = 39.55 �l I �o �I FL = 39.59 c� // II (SEE DETAIL SHEET C8) ° I // I I ----------------------- I c - -- j------- - ---FG = 40.37- A M / FG = 40.28 FL 39.73 1 59 _ = a o� a ' � I a oI I 1.5_�� � � I ro FL = 39.84 EG = 40.50 1 I I TC = 40.35 BC = 39. 85 EG = 40.50 DRI VEWA Y GRADING DETAIL PER COR STD. DTL. 104.3 1' = 10' UTILITY CROSSING TABLE CROSSING NO. E.G. UTILITY BOTTOM OF PIPE TOP OF PIPE CLEARANCE (FT) O 39.92 12 " SD 3718 1.51 12" WA 35.67 0 39.97 8" SD 37.27 2.95 8" WA 34.32 0 39.91 6" WA 35.86 1.57 8" SS 34.29 ® 39.84 6" WA 35.79 1.54 8" SS 34.25 0 39.49 12" SO 36.31 1.50 6" WA 1 34.81 UTILITY CROSSING NOTES: 1. ALL LOCATIONS OF POWER, GAS, AND OTHER DRY UTILITIES SHOWN IN PROFILE ARE APPROXIMATE. 3' OF COVER FROM THE EXISTING GRADE WAS ASSUMED FOR ALL OF THE EXISTING DRY UTILITIES. CONTRACTOR TO POTHOLE ALL EXISTING UTILITIES TO CONFIRM THERE ARE NO CONFLICTS. IF ANY CONFLICTS WITH THE PROPOSED WATER MAIN AND STORM LINE ARE FOUND, EXISTING SERVICES WILL BE RELOCATED SO AS TO PROVIDE THE MINIMUM 1' OF VERTICAL SEPARATION. 2. REQUIRED MINIMUM VERTICAL SEPARATION FOR ALL UTILITES CAN BE FOUND BELOW S-417601 W-417601 R-417Rflri p • H C) U G Q LL IN COMPLIANCE WITH CITY OF RENTON STANDARDS J DEVELOPMENT ENGINEERING Michael Sippo 10/07/2024 O WASTEWATER UTILITY z WATER UTILITYASWAL, 7 ABDOUL GAFOUR 10/07/2024 jstowell 10/08/2024 U) DATE: v BASSANO MULTI -FAMILY 11.20.20 m UTILITY, ROAD, AND GRADING PLAN FIELD PAGE: UTILI TY CROSSING ALLOWABLE CLEARANCE UTILITY VERTICAL CLEARANCE NA TURAL GAS 12 INCHES ELECTRIC 12 INCHES TELECOMMUNICATIONS 12 INCHES FIBER OPTICS 12 INCHES SANITARY SEWER 18 INCHES STORM DRAINAGE 18 INCHES RECLAIMED WATER 18 INCHES 117 WELLS AVENUE S C5 RENTON, WASHINGTON 98057 SHEET: 5 OF: 20 DRS PROJECT NO. 20070