Loading...
HomeMy WebLinkAboutR-417615c0 ti T 1 N n i LLJ Q Z b- T I r) LU r Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) TO ME BOXES DRAINING GRAVEL NW 1/4 SECTION 17, TOWNSHIP 23 N, RANGE 5 W, W.M. BA SSA NO MUL TI=FA MIL Y NOTES: 1. ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE DCVA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE DCVA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE DCVA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS —CONNECTION CONTROL SPECIALIST, FAX NO. 425-430-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. Y 34" TO 2" DOUBLE CHECK VALVE STD. PLAN — 340.8 e PUBLIC WORKS ASSEMBLY FOR IRRIGATION OR - DEPARTMENT RESIDENTIAL FIRE SPRINKLER MARCH 2O10 7J � 'A I M w O d d O d p d Cr 6" MIN I _I 12" G M a j _ 24" K I '1 MIN F �0 MIN COS L I I I I d 6" I 12" �MIN 6r' BMIN MIN Q I ° d �� �� �n �i n n ,•_` r OI] o CD m o I 12111 N a° L---------------- ----------A---- MIN _ a OR a Q °d ° c NOTES: 1. WHERE PIV IS LOCATED INSIDE THE VAULT, THE VAULT LID SHALL BE CORE DRILLED WITH LINK SEAL OR GROUT TO SEAL THE PIPE PENETRATION. ALTERNATIVE PIV LOCATION SHALL BE APPROVED BY THE FIRE MARSHAL. 2. MINIMUM CLEARANCE OF 6" SHALL BE MAINTAINED BETWEEN VALVES, FITTINGS, AND VAULT WALL. 3. ALL PIPE JOINTS SHALL BE RESTRAINED AND CONCRETE BLOCKING IS REQUIRED AT CHANGES IN DIRECTION. 4. CORE DRILL (O.D. +2") CONCRETE VAULT IF KNOCK -OUTS ARE NOT PROVIDED. MATERIALS OA BACKFLOW ASSEMBLY DCDA PER STD PLAN 350.3, POSITIONED WITHIN ACCESS HATCH TO ALLOW FOR VERTICAL REMOVAL OB PIPE CLASS 53 DI PIPE (PExFL OR FLxFL) OC POST INDICATOR VALVE PIV BETWEEN LAST VALVE ON BACKFLOW ASSEMBLY AND FDC, IN ONE OF TWO POSITIONS SHOWN OD TEE TEE (FLxFL) OE ADAPTER ADAPTER (FLxMJ) OF BEND 90° BEND (FLxFL) OG VALVE CHECK VALVE (FLxFL) OFIRE DEPARTMENT FDC PER RRFA REQUIREMENTS, LOCATED DOWNSTREAM OF BACKFLOW ASSEMBLY, INSTALLED ON THE SIDE CONNECTION OF THE VAULT WITH THE LARGEST AVAILABLE SPACE AS SHOWN OI CONCRETE VAULT OLDCASTLE PRECAST VAULT OR EQUAL, SIZED TO ACCOMMODATE FDC, PIV, AND CHECK VALVE INSIDE THE VAULT AND MAINTAIN REQUIRED MINIMUM CLEARANCES TWO LOCKING HINGED ALUMINUM DOORS, TRAFFIC -RATED, WITH SLIP RESISTANT TREATMENT, MARKED JO ACCESS HATCH "WATER", LW PRODUCTS OR EQUAL OK LADDER GALVANIZED STEEL LADDER SECURED TO VAULT PER STD PLAN 370.5 OL WALL FLANGE MIDSPAN PIPE RESTRAINT WITH CONCRETE BLOCKING PER STD PLAN 370.4, SEAL PIPE PENETRATIONS WITH WATER -TIGHT GROUT OM PIPE PENETRATION SEAL PIPE PENETRATION WITH WATER -TIGHT GROUT FLOOR DRAIN, MINIMUM 6" PVC, SLOPED TO STORM SEWER OR DAYLIGHT TO DRAINAGE DITCH WITH WIRE ON DRAIN MESH RODENT SCREEN AT DRAIN OUTLET, SEAL PIPE PENETRATION WITH WATER -TIGHT GROUT OO BLOCKING CONCRETE BLOCKING PER STD PLAN 330.1 0 PUBLIC WORKS FDC AND CHECK VALVE DEPARTMENT ROUTED THROUGH BACKFLOW ASSEMBLY VAULT D.R. STRONG CONSUL TING ENGINEERS ENGINEERS PLANNERS SURVEYORS 620 - 7th AVENUE KIRKLAND, WA 98033 0425.8273063 F425.827.2423 1 CITY COMMENTS O4.16.21 YLP 105.24.24 YLP SURVEYED: DJC 2 CITY COMMENTS 7.3.24 YLP 08.23.24 YLP DESIGNED: YLP 3 CITY COMMENTS 9.10.24 YLP 09.19.24 YLP DRAWN: GLB CHECKED: YLP N0. REVISION BY I DATE APPR APPROVE STD. PLAN - 370.3 Works Ad,mistr,tor SCALE: DATE AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY OA WALL FLANGE OB BLOCKING OC PIPE PENETRATION OD GRAVEL DRnGII F 24" MIN p • H O N U MIDSPAN PIPE RESTRAINT, EBAA IRON SERIES 110OSDB MEGALUG OR EQUAL, WRAP WITH POLYETHYLENE ENCASEMENT PRIOR TO PLACEMENT OF CONCRETE BLOCKING CONCRETE THRUST BLOCKING, CAST -IN -PLACE CONCRETE (MINIMUM 3,000 PSI), TO BE SIZED BY DESIGN ENGINEER (MINIMUM 24"x24"x6") CORE DRILL (O.D. +2") VAULT IF KNOCKOUTS ARE NOT PROVIDED, SEAL PIPE PENETRATION WITH WATER -TIGHT GROUT FOUNDATION GRAVEL PER WSDOT STANDARD SPECIFICATIONS, 12" MINIMUM ALL DIRECTIONS PUBLIC WORKS CONCRETE BLOCKING DEPARTMENT ADJACENT TO VAULT VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 QATUM • C TY OF RENTON U'R Planning/Building/Public Works Dept. STD. PLAN - 370.4 N.=t,rh. ... Adm s-, DATE W-417608 R-417615 a LL IN COMPLIANCE WITH CITY OF RENTON STANDARDS J [DEVELOPMENT ENGINEERING Michael Sippo 10/07/2024 0:1 O WATER UTILITY } z ABDOUL GAFOUR 10/07/2024 <�^ CV ) DATE: v n BASSANO MULTI -FAMILY 11.2O.20 m STANDARD WATER DETAILS AND NOTES FIELD PAGE: 117 WELLS AVENUE S C15 RENTON, WASHINGTON 98057 SHEET: OF: 15 20 DRS PROJECT NO. 20070