HomeMy WebLinkAboutW-417606J 73 O z v J VJ M< W L Q z Ld CUT 3LOCK FILL 3' MIN RADIUS UNOBSTRUCTED WORKING AREA AROUND OUTSIDE OF FIRE HYDRANT TE SHEAR BLOCK NOTE: 4'x4'x6" CONCRETE SHEAR BLOCK AROUND FIRE HYDRANT WITH EXPANSION JOINT AT BACK OF SIDEWALK, FINISH TO MATCH SIDEWALK, ALL CONCRETE SHALL BE MINIMUM 3,000 PSI AND SHALL BE MECHANICALLY MIXED - JOB SITE MIXING, HAND -MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. STD. PLAN - 310.2 PUBLIC WORKS FIRE HYDRANT ASSEMBLY DEPARTMENT SHEAR BLOCK AS -BUILT NO AS —BOIL T INFORMA 71ON ON THIS SHEET. "I CERTIFY THAT 7HE INFORMA77ON SHOWN HEREON WHICH WAS AS —BUILT BY D.R. STRONG, AND MAY INCLUDE LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND AS —BUILT COMMENTS, ACCURATELY REFLECTB EXIS77NG FIELD COND177ONS AS DETERMINED BY ME OR UNDER MY DIRECT SUPERVISION ON THIS DATE: 912412025. a Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) 15 Martin Pastucha Public Works Admin —., D.R. STRONG CONSUL TING ENGINEERS ENGINEERS PLANNERS SURVEYORS 620 - 7th AVENUE KIRKLAND, WA 98033 0425.8273063 F 425.827.2423 NW 1/4 SECTION 17, TOWNSHIP 23 N, RANGE 5 W, W.M. BA SSA NO MUL TI=FA MIL Y 6/28/2023 DATE 0.7r'� �4" BLUE REFLECTIVE PAVEMENT MARKER, STIMSONITE MODEL C88 OR EQUAL, PLACED 4" FROM ROADWAY CENTERLINE AS INDICATED BELOW MARKER MARKER I I I I � I TWO LANE ROAD OFFSET MARKER MARKER FOUR LANE ROAD OFFSET MARKER ON SIDE STREETS WHERE THE HYDRANT IS WITHIN 20' OF A MAJOR STREET, THE MARKER SHALL BE INSTALLED ON THAT MAJOR STREET MARKER I FIVE LANE ROAD OFFSET MARKER PUBLIC WORKS FIRE HYDRANT ASSEMBLY DEPARTMENT PAVEMENT MARKER STD. PLAN - 310.3 APPROVED: Martin Pastucha Public Works Administrator DATE MATERIALS U IEE OB PIPE 0 VALVE OD VALVE BOX OE COUPLING OF TUBING OG BEND k, METER SETTER OI METER SPREADER J0 WATER METER OK METER BOX OL COUPLER OM GRAVEL z IN UNIMPROVED ROW } I�/ INSTALL METER BOX AT PROPERTY LINE WITH a 12" COPPER TAILPIECE 0 �I z CITY i PRIVATE w PIPINGI PIPING a i 1 1/2" SERVICE 2" SERVICE 2" TAPPED REDUCING TEE (MJxFIPT) 2" TAPPED REDUCING TEE (MJxFIPT) 2" BRASS NIPPLE (MIPT), 4" LENGTH 2" BRASS NIPPLE (MIPT), 4" LENGTH 2" GATE VALVE (FIPT) WITH SQUARE OPERATING 2" GATE VALVE (FIPT) WITH SQUARE OPERATING NUT AND EXTENSION PER STD PLAN 330.7 NUT AND EXTENSION PER STD PLAN 330.7 VALVE BOX AND LID PER STD PLAN 330.7 VALVE BOX AND LID PER STD PLAN 330.7 2" x 1 %" BRASS COUPLING (MIPT x PACK JOINT), 2" BRASS COUPLING (MIPT x PACK JOINT), FORD FORD C44-76-Q-NL OR EQUAL C84-77-Q-NL OR EQUAL 1 Yz" TYPE "K" SOFT COPPER TUBING 2" TYPE "K" SOFT COPPER TUBING 1 Yz" 90' BRASS BEND (PACK JOINT x PACK JOINT OR 2" 90' BRASS BEND (PACK JOINT x PACK JOINT OR PACK JOINT x FIPT), FORD L44-66-Q-NL OR PACK JOINT x FIPT), FORD L44-77-Q-NL OR L41-66-Q-NL OR EQUAL L41-77-Q-NL OR EQUAL 1 YZ" VERTICAL METER SETTER WITH BYPASS, 2" VERTICAL METER SETTER WITH BYPASS, FLANGED FLANGED ANGLE BALL VALVE AND PADLOCK WINGS ANGLE BALL VALVE AND PADLOCK WINGS ON INLET, ON INLET, ANGLE CHECK VALVE ON OUTLET, AND ANGLE CHECK VALVE ON OUTLET, AND BALL VALVE BALL VALVE ON BYPASS WITH PADLOCK WINGS, ON BYPASS WITH PADLOCK WINGS, FORD VBH86-12B-11-66-Q-NL, A.Y. MCDONALD FORD VBH87-12B-11-77-Q-NL, A.Y. MCDONALD 730B-612WDFF665, OR MUELLER B-2427N (1 YZ"), 730B-612WDFF665, OR MUELLER B-2427N (2"), BYPASS NOT PERMITTED ON IRRIGATION METERS BYPASS NOT PERMITTED ON IRRIGATION METERS 13 %6" RIGID METER SPREADER (TEMPORARY) 17 %, RIGID METER SPREADER (TEMPORARY) AMI WATER METER WITH RADIO AND BATTERY UNIT, AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE SUPPLIED AND INSTALLED BY CITY FORCES TO BE SUPPLIED AND INSTALLED BY CITY FORCES 17"X30" METER BOX, ARMORCAST A6001640PCX18, 17"X30" METER BOX, ARMORCAST A6001640PCX18, WITH METER BOX LID, ARMORCAST WITH METER BOX LID, ARMORCAST A6001947RC1-H7, TO READ "RENTON WATER" A6001947RC1-H7, TO READ "RENTON WATER" 1 Yz" COUPLER (PACK JOINT x PACK JOINT), FORD 2" COUPLER (PACK JOINT x PACK JOINT), FORD C4#-6#-Q-NL OR EQUAL, WITH GALVANIZED PLUG IF C4#-7#-Q-NL OR EQUAL, WITH GALVANIZED PLUG IF PRIVATE SERVICE LINE IS NOT YET INSTALLED PRIVATE SERVICE LINE IS NOT YET INSTALLED CRUSHED ROCK BASE TO SUPPORT METER BOX, CRUSHED ROCK BASE TO SUPPORT METER BOX, METER BYPASS TO BE EXPOSED METER BYPASS TO BE EXPOSED PUBLIC WORKS 11/2" AND 2" WATER SERVICE DEPARTMENT IN PLANTING STRIP 2 CITY COMMENTS 7.3.24 YLP 108.23.24 YLP SURVEYED: SCALE: DJC VERTICAL: NAVD 1988 83/1 3 CITY COMMENTS 9.10.24 YLP 09.19.24 YLP DESIGNED: AS NOTED HORIZONTAL: NAD 193/1991 4 STORM REVISION DUE TO DUCT BANK CONFLICT YLP 12.13.24 YLP YLP 5 UTILITY REVISION YLP 01.10.25 YLP DRAWN: GLB ONE INCH LEI YI� 6 UTILITY REVISION YLP 01.24.25 YLP CHECKED: Y� , v AT FULL SCALE IF NOT ONE INCH N 0. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY YLP STD. PLAN - 320.2 ha DATE Administrator W-417606 R-417613 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: BASSANO MULTI -FAMILY 11.20.20 C TY OF STANDARD WATER DETAILS AND NOTES FIELDBOOK: RENT 0 N PAGE: 7 DRAWING N0: Planning/Building/Public Works Dept. 117 WELLS AVENUE S C 13 RENTON, WASHINGTON 98057 SHEET: OF: 13 20 O N U (D N DRS PROJECT NO. 20070