HomeMy WebLinkAboutS-417603(.0(0 r" N CV fi Ira L Ld Z L, r Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) 7J A NW 114 SECTION 17, TOWNSHIP 23 N, RANGE 5 W, W.M. BASSANO MULT1=FAM,1LY � STA. 3+01.06' 17.95' R = 0❑ STA. 10+56.93, 30.47' L CUT IN CONNEC71ON BY CITY FORCES TO I \ N8824'50"W 120.09' --------- - - ---------------- CB 1, TYPE 1 STA. 2+70.67, 19.05' L _ RIM 39.67 r - 0 6" IE IN 3Z 48 (W) 8" IE OUT 3Z 48 (E) sW 10 r0 o a. -----, ------------------ - a a 45 - 45 EG ® CENTERLINE OF PROPOSED STORM LINE 40-------------- 40 'Fl[ 32 LF D.l ---- ® 1.03�' (P3) 0 APPROXIMATE LOCATION OFI EXIS77NG DRY U77LI77ES CABLE, it 35 POWER, ETC.) UNDER SIDEWALK 35 CB 1, TYPE 1 STA. 3+01.06' 17.95' R STA. 2+70.67, 19.05' L STA. 10+56.93, 30.47' L RIM 39.67 CUT IN CONNECTION BY CITY FORCES TO USE CUT IN 6" IE IN 37.48 (W) TEE W/ TWO VALVES PER COR STD. PLAN 300.2 (SEE SHEET C11): 8" IE OUT JZ48 (E) 1-6"X6" TEE (FLXFL) W/ 30 APPROXIMA7E LOCATION OF CONCRETE THRUST BLOCKING 30 EXIS77NG UNDERGROUND GAS LINE 2-6" GATE VALVES (FLXMJ) X. O2 8" SEWER CROSSING 3-6" SOLIDOOL SLEEVE (MJ) EQ ) 2.95 CLEARANCE (INSTALL DEAD MAN BLOCK AND END CAP (MJ) ON 12" D/ WATER CROSSI Q EXIS77NG 6" WATER MAIN TO RESTRAIN NEW 90' BEND) 1.50 CLEARANCE 1 STA. 3+01. 04 , 10.29' R 12 LF 6" D/ CL. 52 25 STA. 10+49.27, 30.43 L I y SOUD SLEEVE 25 1-12"X6" TEE (FLXFL) Q5 X. 12" PVC STORM CROSSING 1-6" GATE VALVE (FLXMJ) 1 1.50' CLEARANCE 1-12" GATE VALVE (FLXMJ) CB 2, TYPE 1 1-12" ADAPTER (FLxMJ) W/ (SADDLE EXISTING STORM MAIN) CONCRETE THRUST BLOCKING 1-12" PIPE SPOOL STA. 2+70.61, 13.41' R 20 1-12" POL YPIG STA 77ON PER S7D. RIM 8 I 39. 77 W / IN 37.15 W 20 PLAN NO 300.7 SHACKLE TEE, VALVE TO DEAD MAN BLOCK (SEE SHEET C12) EX. 12" IE IN 3 (S) (INSTALL DEADMAN BLOCK TO EX. 12 / OUT 36.27 (N) RESTRAINT VALVE AND TEE) PROPOSED STORM LINE N to o o N O per' 0 9+60 10+00 D.R. STRONG CONSUL TING ENGINEERS ENGINEERS PLANNERS SURVEYORS 620 - 7th AVENUE KIRKLAND, WA 98033 0425.8273063 F 425.827.2423 10+40 10+80 11 +20 1 CITY COMMENTS O4.16.21 YLP 05.24.24 2 CITY COMMENTS 7.3.24 YLP 08.23.24 3 CITY COMMENTS 9.10.24 YLP 09.19.24 N0. REVISION BY DATE a 12 LF 6" Dl CL. 52 W SOLID SLEEVE wj -Ell ° o_ _ _5 I I 8 L F 6Dl CL. 52 J I I I I I + 6" DI Ct,52 I �I a 3 2- i_ LF 8" D.L , -- ° ® 1. 0" (P3) I I I I I I I I J I I I I I LI II' I I I I I I I I I I I YLP SURVEYED: DJC YLP DESIGNED: YLP YLP DRAWN: GLB CHECKED: YLP AP P R APPROVED: YLP SCALE: ° USE CUT IN TEE W/ TWO VALVES PER COR STD. PLAN 300.2 (SEE SHEET C11): 1-6 "X6" TEE (FLXFL) W/ CONCRETE THRUST BLOCKING 2-6" GATE VALVES (FLXMJ) 3-6" DI SPOOL (LF AS REQ.) 3-6" SOLID SLEEVE (MJ) (INSTALL DEAD MAN BLOCK AND END CAP RON EXIS77NG 6" WA ESTRAIN NEW 90 BEND) R MAIN TO STA. 3+01.04' 5.50' R STA. 10+49.27, 30.43' L 1-12"X6" TEE (FLXFL) / 1-12"GGATEVALVE VALVE(FLXMJ(FLXMJ) 1-12" ADAPTER (FLxMJ) W/ _ CONCRETE THRUST BLOCKING 1 + 9.041-12PIPE SPOOL � 1-12" POL YPIG STA T7ON PER STD. PLAN NO 300.7 SHACKLE TEE, VALVE TO DEAD MAN BLOCK (SEE SHEET C12) (INSTALL DEADMAN BLOCK TO RESTRAINT VALVE AND TEE) CB 2, TYPE 1 (SADDLE EXIS77NG STORM MAIN) STA. 2+70.61, 13.41' R _ RIM 39.77 8" JE IN 37.15 (W) EX. 12" IE IN 36.27 (S) II I EX. 12 /E OUT 36.27 (N) UTILITY CROSSING TABLE CROSSING NO. E.G. UTILITY BOTTOM OF PIPE TOP OF PIPE CLEARANCE (FT) 0 39.92 12 " SD 37.18 1.51 12" WA 35.67 0 39.97 8" SO 37.27 2.95 8" WA 34.32 0 39.91 6" WA 35.86 1.57 8" SS 34.29 ® 39.84 6" WA 35.79 1.54 8" SS 34.25 0 39.49 12" SD 36.31 1.50 6" WA 34.81 UTILITY CROSSING NOTES.- 1 . ALL LOCATIONS OF POWER, GAS, AND OTHER DRY UTILITIES SHOWN IN PROFILE ARE APPROXIMATE. 3' OF COVER FROM THE EXISTING GRADE WAS ASSUMED FOR ALL OF THE EXISTING DRY UTILITIES. CONTRACTOR TO POTHOLE ALL EXISTING UTILITIES TO CONFIRM THERE ARE NO CONFLICTS. IF ANY CONFLICTS WITH THE PROPOSED WATER MAIN AND STORM LINE ARE FOUND, EXISTING SERVICES WILL BE RELOCATED SO AS TO PROVIDE THE MINIMUM 1' OF VERTICAL SEPARATION. VERTICAL: NAVD 1988 AS NOTED HORIZONTAL: NAD 1983/1991 ONE INCH DATUM AT FULL SCALE DATUM IF NOT ONE INCH SCALE ACCORDINGLY NORTH GRAPHIC SCALE 0 10 20 40 1 INCH = 20 FT. HORIZONTAL 0 2.5 5 10 1 INCH = 5 FT VERTICAL C TY OF RENTON U'R v4mgv Planning/Building/Public Works Dept. S-417603 W-417603 R-417607 p 0; H CD U Q H IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Surface Water Enginering■ Michael Sippo 10/07/2024 5 JFarah 10/07/2024 O WASTEWATER UTILITY �' ZQ jstowel l 10/08/2024 DATE:! Cl) BASSANO MULTI -FAMILY 11.20.20 m PROPOSED STORM LINE PLAN AND PROFILE FIELD PAGE: 117 WELLS AVENUE S C7 RENTON, WASHINGTON 98057 SHEET: 7 OF: 20. DRS PROJECT NO. 20070