HomeMy WebLinkAbout2024-10-21 Skattum Renton Record DrawingsPUBLIC106TH AVE SE 106TH AVE SELOT 1LOT 2LOT 3LOT 4LOT 6LOT 5LOT 11TRACT ALOT 10LOT 9LOT 7LOT 8PUBLICSE 172ND ST108TH AVE SE
0GRAPHIC SCALE201020SCALE: 1" = 20'CITY OFRENTONLUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 1
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055PLAT COVER SHEET10-21-2024 TED-40-4041
R-404101””C:18-006046 PR:17-000022VICINITY MAPPROJECT DATAPROJECT TEAMLEGAL DESCRIPTIONHORIZONTAL DATUMVERTICAL DATUMSHEET INDEXPLAT CONDITIONS OF APPROVALSITELEGEND
PUBLIC
106TH AVE SEretainremoveremoveremoveretainretainretainremove
0GRAPHIC SCALE201020SCALE: 1" = 20'CITY OFRENTONLUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 2
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055TEMPORARY EROSION & SEDIMENT CONTROLCLEARING, TREE RETENTION, & REPLACEMENT PLAN05-18-2024 TED-40-4041
R-404102C:18-006046 PR:17-000022NOTESCONSTRUCTION SEQUENCESEE TREE PROTECTIONNOTES SHEET 11
PUBLIC106TH AVE SE 106TH AVE SE
LOT 1LOT 2LOT 3LOT 4LOT 6LOT 5LOT 11TRACT ALOT 10LOT 9LOT 7LOT 80GRAPHIC SCALE201020SCALE: 1" = 20'CITY OFRENTONLUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 3
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055GRADING PLAN10-14-2024 TED-40-4041
R-404103C:18-006046 PR:17-000022DRIVEWAY TABLE:
PUBLIC
106TH AVE SE
106TH AVE SE
LOT 1LOT 2LOT 3LOT 4LOT 6LOT 5LOT 11TRACT ALOT 10LOT 9LOT 7LOT 8PUBLIC106TH AVE SEPUBLICSE 172ND ST0GRAPHIC SCALE201020SCALE: 1" = 20'CITY OFRENTONLUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 4
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055ROAD & DRAINAGE CONTROL PLAN10-21-2024 TED-40-4041
R-404104C:18-006046 PR:17-000022 IMPERVIOUS SURFACE TABLE:CROSSING TABLE:
PUBLIC106TH AVE SE 106TH AVE SE
LOT 1LOT 2LOT 3LOT 4LOT 6LOT 5LOT 11TRACT ALOT 10LOT 9LOT 7LOT 8PUBLIC106TH AVE SEPUBLICSE 172ND ST0GRAPHIC SCALE201020SCALE: 1" = 20'CITY OFRENTONLUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 5
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055WASTEWATER & WATERUTILITY PLAN10-14-2024 WWP-40-4041WTR-40-4041
W-404101S-404101C:18-006046 PR:17-000022NOTE:AS-BUILT NOTE:
CITY OFRENTONLUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 6
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055STREET PROFILES & DETAILS10-14-2024 TED-40-4041
R-404105C:18-006046 PR:17-000022 CROSSING TABLE:
CITY OFRENTONLUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 7
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055DETENTION TANK DETAILS10-14-2024 TED-40-4041
R-404106C:18-006046 PR:17-000022NOTERESTRICTOR SPECIFICATIONSINTERCEPTOR TRENCH DETAILNOTECONTROL STRUCTURE MODEL OUTPUT
CITY OFRENTONLUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 8
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055ADA WHEELCHAIR RAMP PLANS10-24-2023 TED-40-4041
R-404107C:18-006046 PR:17-000022
CITY OFRENTONLUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 9
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055CITY OF RENTON STORMWATER DETAILS10-24-2023 TED-40-4041
R-404108C:18-006046 PR:17-000022
CITY OFRENTONLUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 10
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055ROAD SECTIONS,CITY OF RENTON DRAINAGE NOTES & DETAILS10-24-2023 TED-40-4041
R-404109” C:18-006046 PR:17-000022
CITY OFRENTONLUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 10
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055CITY OF RENTON EROSION CONTROL DETAILS10-24-2023 TED-40-4041
C:18-006046 PR:17-000022“– ” ’R-404110TREE PROTECTION MEASURES
167281.86 N 1302435.71 E
167178.14 N 1302432.53 E
167068.85 N 1302428.84 E
167132.00 N 1302454.83 E
167159.31 N 1302511.02 E
167128.56 N 1302564.63 E
167156.01 N 1302621.20 E
167125.33 N 1302674.43 E
167152.78 N 1302729.76 E 10-
21
-202
STAMPED FOR AS-BUILT PURPOSES
ONLY TO DOCUMENT LOCATION OF
DESIGNED FEATURES, NOT TO IMPLY
ASSUMPTION OF RESPONSIBILITY FOR
THE DESIGN WORK PERFORMED.
NOTE:
TRAFFEX IS NOT AVAILABLE TO PROVIDE
ASBUILT INFORMATION OR UPDATE THE
PLAN VIEW, SHOWING LOCATIONS. G2 CIVIL
HAS ENTERED THE GPS COORDINATES FOR
AS-BUILT PURPOSES.
10-21
-202
STAMPED FOR AS-BUILT PURPOSES
ONLY TO DOCUMENT LOCATION OF
DESIGNED FEATURES, NOT TO IMPLY
ASSUMPTION OF RESPONSIBILITY FOR
THE DESIGN WORK PERFORMED.
DETAIL SHEETS HAVE NOT BEEN
MODIFIED.
10-21
-
2
0
2
STAMPED FOR AS-BUILT PURPOSES
ONLY TO DOCUMENT LOCATION OF
DESIGNED FEATURES, NOT TO IMPLY
ASSUMPTION OF RESPONSIBILITY FOR
THE DESIGN WORK PERFORMED.
DETAIL SHEETS HAVE NOT BEEN
MODIFIED.
PUBLIC106TH AVE SELOT 1LOT 2LOT 3LOT 4LOT 6LOT 5LOT 11TRACT ALOT 10LOT 9LOT 7LOT 8106TH AVE SE LOT 1LOT 2LOT 4LOT 6TRACT ALOT 10LOT 9LOT 7LOT 8LOT 5LOT 11LOT 3LandscapeArchitectureAOAEnvironmentalPlanning &Office (425) 333-4535PO Box 578Carnation, WA 98014Fax (425) 333-4509Altmann Oliver Associates, LLCLUA 16-000981UTILITIES UNDERGROUND LOCATION CENTER(ID,MT,ND,OR,WA)811CALL 3 WORKING DAYS BEFORE YOU DIGSAFETY PRECAUTION SHALL BE IMPLEMENTED BYCONTRACTOR(S) AT ALL TRENCHING IN ACCORDANCEWITH CURRENT OSHA STANDARDSELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SURVEY - PINKTEL/CATV - ORANGE PROPOSED - WHITE WATER - BLUERenton Subdivision
Renton SubdivisionSheet 15
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055LANSCAPE PLANR-404111TED-40-4041
PR:17-000022C:18-006046
1
0-
2
1-
2
0
2
STAMPED FOR AS-BUILT PURPOSESONLY TO DOCUMENT LOCATION OFDESIGNED FEATURES, NOT TO IMPLYASSUMPTION OF RESPONSIBILITY FORTHE DESIGN WORK PERFORMED. LANDSCAPING SHEETS HAVE NOT BEEN MODIFIED.
LandscapeArchitectureAOAEnvironmentalPlanning &Office (425) 333-4535PO Box 578Carnation, WA 98014Fax (425) 333-4509Altmann Oliver Associates, LLCLUA 16-000981UTILITIES UNDERGROUND LOCATION CENTER(ID,MT,ND,OR,WA)811CALL 3 WORKING DAYS BEFORE YOU DIGSAFETY PRECAUTION SHALL BE IMPLEMENTED BYCONTRACTOR(S) AT ALL TRENCHING IN ACCORDANCEWITH CURRENT OSHA STANDARDSELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SURVEY - PINKTEL/CATV - ORANGE PROPOSED - WHITE WATER - BLUERenton Subdivision
Renton SubdivisionSheet 16
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055PLANT SCHEDULE & DETAILSPR:17-000022C:18-006046R-404112TED-40-4041
1
0-
2
1-
2
0
2
STAMPED FOR AS-BUILT PURPOSESONLY TO DOCUMENT LOCATION OFDESIGNED FEATURES, NOT TO IMPLYASSUMPTION OF RESPONSIBILITY FORTHE DESIGN WORK PERFORMED. DETAIL SHEETS HAVE NOT BEEN MODIFIED.
LandscapeArchitectureAOAEnvironmentalPlanning &Office (425) 333-4535PO Box 578Carnation, WA 98014Fax (425) 333-4509Altmann Oliver Associates, LLCLUA 16-000981UTILITIES UNDERGROUND LOCATION CENTER(ID,MT,ND,OR,WA)811CALL 3 WORKING DAYS BEFORE YOU DIGSAFETY PRECAUTION SHALL BE IMPLEMENTED BYCONTRACTOR(S) AT ALL TRENCHING IN ACCORDANCEWITH CURRENT OSHA STANDARDSELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SURVEY - PINKTEL/CATV - ORANGE PROPOSED - WHITE WATER - BLUERenton Subdivision
Renton SubdivisionSheet 17
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055CONSTRUCTION SPECIFICATIONSPR:17-000022C:18-006046R-404113TED-40-4041
1
0-
2
1-
2
0
2
STAMPED FOR AS-BUILT PURPOSESONLY TO DOCUMENT LOCATION OFDESIGNED FEATURES, NOT TO IMPLYASSUMPTION OF RESPONSIBILITY FORTHE DESIGN WORK PERFORMED. SPECIFICATION SHEETS HAVE NOT BEEN MODIFIED.
PUBLIC106TH AVE SEPUBLIC106TH AVE SE16.611"412.51"12.751"611.51"11.971"89.441"916.01"9.7921"12.6101"7.53111"14.9121"10.6131"T161"12T21"SYMBOLMANUFACTURER/MODEL/DESCRIPTIONToro O-T-570Z-06P-PR 5 SeriesShrub Spray, 6" Pop-Up, with Built In-Riser Pressure Regulator.Also includes the Zero Flush Wiper Seal. 1/2" Female-ThreadedInlet. Precision Series spray nozzles.Toro O-T-570Z-06P-PR 8 SeriesShrub Spray, 6" Pop-Up, with Built In-Riser Pressure Regulator.Also includes the Zero Flush Wiper Seal. 1/2" Female-ThreadedInlet. Precision Series spray nozzles.Toro O-T-570Z-06P-PR 10 SeriesShrub Spray, 6" Pop-Up, with Built In-Riser Pressure Regulator.Also includes the Zero Flush Wiper Seal. 1/2" Female-ThreadedInlet. Precision Series spray nozzles.Toro O-T-570Z-06P-PR 12 SeriesShrub Spray, 6" Pop-Up, with Built In-Riser Pressure Regulator.Also includes the Zero Flush Wiper Seal. 1/2" Female-ThreadedInlet. Precision Series spray nozzles.Toro O-T-570Z-06P-PR 15 SeriesShrub Spray, 6" Pop-Up, with Built In-Riser Pressure Regulator.Also includes the Zero Flush Wiper Seal. 1/2" Female-ThreadedInlet. Precision Series spray nozzles.Toro O-T-570Z-06P-PR 4X Strip SprayShrub Spray, 6" Pop-Up, with Built In-Riser Pressure Regulator.Also includes the Zero Flush Wiper Seal. 1/2" Female-ThreadedInlet. Precision Series spray nozzles.Toro PRN-TA, TF 570Z-4P-COM ADJTurf Precision Series Rotating Nozzle on 4" pop-up riser, withcheck valve. Adjustable or 360 as indicated.Hunter PROS-PRS30-04-MSBNMulti-Stream Bubbler, 4in. pop-up, 25=.25gpm, 50=0.5gpm,10=1.0gpm, 20=2.0gpm.SYMBOLMANUFACTURER/MODEL/DESCRIPTIONToro 252-26 GlobeElectric, 1", 1-1/2", and 2" In-Line Plastic Remote Control Valve.Includes Flow Control. Globe Body Configuration.Debris-Resistant Valve.Rain Bird 33-DLRC3/4" Brass Quick-Coupling Valve, with Corrosion-ResistantStainless Steel Spring, Locking Thermoplastic Rubber Cover,Double Track Key Lug, and 2-Piece Body.Matco-Norca 759Brass Shut Off Ball Valve, 1/2" to 4". Two Piece Body, Blow-OutProof Stem, Chrome Plated Solid Brass Ball, Threaded, withPTFE Seats. Same size as mainline pipe.Toro P220-26-0 GLOBE 1"Electric, 1", 1-1/2", 2" and 3" Plastic In-Line Master Valve.Equipped to withstand pressure up to 220 PSI. Filter screen on 2"and 3" models. Standard Solenoid. Globe Body Style.Zurn 500XLPressure required downstream is 56.8 PSIZurn 350XL 1"Double Check Valve Assembly w/ EZSwap insert.Hunter NODE-100 at replacement treesSingle Station Controller, Outdoor, Battery Powered. DC LatchingSolenoid Included.Hunter NODE-100 at replacement treesSingle Station Controller, Outdoor, Battery Powered. DC LatchingSolenoid Included.Hunter XCH-1200-SSElectromechanical controller, 12 stations, outdoor model,battery-powered. Stainless Steel Cabinet. Forresidential/commercial use.Hunter XCHSPOLESteel Mounting Pole, 4`. Comes with outdoor stainless steelcabinet for XCH-SS controllers. Required SCHSPB mountingbracket.Hunter MINI-CLIKRain Sensor, mount as notedWater Meter 3/4"Irrigation Lateral Line: PVC Class 200 SDR 21Irrigation Mainline: PVC Schedule 40Pipe Sleeve: PVC Schedule 40IRRIGATION SCHEDULE1.THIS PLAN IS DIAGRAMMATIC ONLY. VERIFY ALL DIMENSIONS AND ELEVATIONS IN FIELD. ADJUSTEQUIPMENT LAYOUT TO SUIT FIELD CONDITIONS AND SITE CONSTRAINTS.2.EQUIPMENT SHOWN IN PAVED AREAS OR OUTSIDE PROJECT LIMITS IS FOR GRAPHIC CLARITY ONLY.INSTALL IN LANDSCAPED AREA. DO NOT WILLFULLY INSTALL EQUIPMENT UNDER PAVEMENT OROUTSIDE PROJECT LIMITS.3.DESIGN ASSUMPTIONS: 22 GPM AT 70-98 PSI STATIC PRESSURE AT THE METER. VERIFY IN FIELD.4.SEE IRRIGATION SCHEDULE FOR PRESSURE REGULATING VALVE SETTING.5.ADJUST SPRINKLER ARC AND RADIUS AS NEEDED TO AVOID OVER SPRAY ONTO HARD SURFACES,WHILE MAINTAINING PLANT COVERAGE.6.COVER DEPTH: MAIN LINE--18 INCHES; LATERALS--12"; SLEEVES--36" UNDER VEHICULAR CROSSINGS,24" UNDER WALKWAYS.7.PIPES MAY SHARE TRENCHES. PROVIDE 4" LATERAL, AND 6" VERTICAL SPACING BETWEEN PIPES.8.USE CARE WHEN TRENCHING IN EXISTING TREE ROOT ZONES. HAND TRENCH ONLY. TUNNEL UNDERROOTS GREATER THAN 2" DIAMETER. CLEANLY ROOT PRUNE SMALLER ROOTS. BACK FILLIMMEDIATELY OR COVER WITH DAMP BURLAP.9.HYDROSTATIC PRESSURE TESTS: WITH THE MAIN LINE PURGED OF AIR AND FILLED WITH WATER,PRESSURIZE TO 150PSI. IF PRESSURE LOSS IS GREATER THAN 5PSI AFTER 60 MINUTES, REPAIRSMUST BE MADE AT CONTRACTOR'S EXPENSE AND SYSTEM RE-TESTED. WITH ALL LATERAL LINESPURGED OF AIR AND ALL RISERS/SWING JOINTS CAPPED, FILL SYSTEM WITH WATER AT LINEPRESSURE. IF PRESSURE LOSS IS GREATER THAN 5PSI AFTER 30 MINUTES, REPAIRS MUST BE MADEAT CONTRACTOR'S EXPENSE AND SYSTEM RE-TESTED. NOTIFY LANDSCAPE ARCHITECT OF TESTSCHEDULE 72 HOURS PRIOR TO TESTING.NOTESNUMBERMODELSIZETYPEGPMPSIPSI @ POCPRECIP1Toro 252-26 Globe1"Shrub Spray16.6235.549.70.93 in/h2Toro 252-26 Globe1"Shrub Spray9.7935.145.10.97 in/h4Toro 252-26 Globe1"Shrub Spray12.535.848.10.88 in/h5Toro 252-26 Globe1"Shrub Spray12.7335.548.10.92 in/h6Toro 252-26 Globe1"Shrub Spray11.5134.647.60.93 in/h7Toro 252-26 Globe1"Shrub Spray11.9437.850.30.96 in/h8Toro 252-26 Globe1"Shrub Spray9.4434.945.90.98 in/h9Toro 252-26 Globe1"Shrub Spray15.9537.353.10.9 in/h10Toro 252-26 Globe1"Shrub Spray12.6135.347.60.89 in/h11Toro 252-26 Globe1"Shrub Spray7.5333.943.60.88 in/h12Toro 252-26 Globe1"Turf Rotary14.8746.360.40.52 in/h13Toro 252-26 Globe1"Shrub Spray10.5637.648.81.11 in/hT1Toro 252-26 Globe1"Bubbler635.544.727.23 in/hT2Toro 252-26 Globe1"Bubbler1237.350.327.23 in/hVALVE SCHEDULELUA 16-000981UTILITIES UNDERGROUND LOCATION CENTER(ID,MT,ND,OR,WA)811CALL 3 WORKING DAYS BEFORE YOU DIGSAFETY PRECAUTION SHALL BE IMPLEMENTED BYCONTRACTOR(S) AT ALL TRENCHING IN ACCORDANCEWITH CURRENT OSHA STANDARDSELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SURVEY - PINKTEL/CATV - ORANGE PROPOSED - WHITE WATER - BLUERenton Subdivision
Renton SubdivisionSheet 1
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055IRRIGATION PLAN1
0-
2
1-
2
0
2
STAMPED FOR AS-BUILT PURPOSESONLY TO DOCUMENT LOCATION OFDESIGNED FEATURES, NOT TO IMPLYASSUMPTION OF RESPONSIBILITY FORTHE DESIGN WORK PERFORMED. IRRIGATION SHEETS HAVE NOT BEEN MODIFIED.R-404114
DCVA IN VALVE BOX123344561234567789891MASTER CONTROL VALVE2QUICK COUPLING VALVE IN BOX3BRASS ISOLATION VALVE4TURF SPRAY FLEX ASSEMBLY5SHRUB SPRAY FLEX ASSEMBLY6REMOTE CONTROL VALVE WITH THREADED UNIONS7SLEEVE DETAIL812NOTECONTROLLER SHALL BE HARD-WIRED TO GROUNDED110 VAC POWER SOURCE34IRRIGATION CONTROLLER (XCH-SS) PER PLANSTAINLESS STEEL POLE AND MOUNTING BRACKET1FINISHED GRADECONCRETE234HUNTER XCH CONTROLLER ON STEEL POLE10LUA 16-000981UTILITIES UNDERGROUND LOCATION CENTER(ID,MT,ND,OR,WA)811CALL 3 WORKING DAYS BEFORE YOU DIGSAFETY PRECAUTION SHALL BE IMPLEMENTED BYCONTRACTOR(S) AT ALL TRENCHING IN ACCORDANCEWITH CURRENT OSHA STANDARDSELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SURVEY - PINKTEL/CATV - ORANGE PROPOSED - WHITE WATER - BLUERenton Subdivision
Renton SubdivisionSheet 1
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055IRRIGATION DETAILSFINISH GRADESTANDARD VALVE BOXPRV AS SPECIFIEDMAIN LINEFEMALE ADAPTERSCH. 80 NIPPLES (2)6" WASHED GRAVEL SUMPLANDSCAPE CLOTH-WRAP UP SIDESPRESSURE REDUCING VALVE9LUA 16-000981UTILITIES UNDERGROUND LOCATION CENTER(ID,MT,ND,OR,WA)811CALL 3 WORKING DAYS BEFORE YOU DIGSAFETY PRECAUTION SHALL BE IMPLEMENTED BYCONTRACTOR(S) AT ALL TRENCHING IN ACCORDANCEWITH CURRENT OSHA STANDARDSELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SURVEY - PINKTEL/CATV - ORANGE PROPOSED - WHITE WATER - BLUERenton Subdivision
Renton SubdivisionSheet 1
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055IRRIGATION DETAILSHUNTER NODE 100 CONTROLLER91
0-
2
1-
2
0
2
STAMPED FOR AS-BUILT PURPOSESONLY TO DOCUMENT LOCATION OFDESIGNED FEATURES, NOT TO IMPLYASSUMPTION OF RESPONSIBILITY FORTHE DESIGN WORK PERFORMED. DETAIL SHEETS HAVE NOT BEEN MODIFIED.R-404115