Loading...
HomeMy WebLinkAboutMFP24004381.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP24004381 IVR Number: 24004381 Permit Information Permit Name: Comcast Cable Franchise Permit - 820 SW 41st St - JB-1903160 Address/Location:08/28/2024Application Date:3623049001Parcel Number: 820 SW 41ST ST Permit Type:11/07/2024Issue Date:Franchise Permit Work Class:11/07/2025Expiration Date:Major Utility Job Number: JB-1903160Franchise Type:Cable 11/07/2024Finalize Date: Description: Comcast JB 1903160. 96ct Fiber 1001' bore/trench, 727' pulled through existing conduit, splicing in various locations. Pothole all existing utilities. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Jacob Neu ADP-Resources, LLC 163 SW Academy St. Dallas, OR 97338 ApplicantX Joshua Ashley Comcast 410 Valley Ave NW, Suite 12 Bldg C Puyallup, WA 98371 B: (503) 939-7931Contact Permitting Department Cannon Construction LLC 406 Porter Way Milton, WA 98354 B: (253) 922-2787x286 Contractor Business License Number: 20838Electrical Contractor: CANNOCL7941N Construction Contractor: CANNOCL791JK Joshua Ashley Comcast 410 Valley Ave NW, Suite 12 Bldg C Puyallup, WA 98371 B: (503) 939-7931Emergency Contact PROLOGIS LP - C/O RE TAX 60 STATE STREET SUITE 2200 BOSTON , MA 02109 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐ Electronic Copy of the TCP Application ☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:  Include map(s) showing the location of the project and work area.  Be legible lettering and clear, contrasting, symbols of viewing or printing.  Must indicate street names, and north arrow and scale.  Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering MFP24004381 Monday Friday 8:00am 3:00pm Scott Warlick CED 11/7/2024 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING:  Must have approved Traffic Control Plan (TCP) prior to commencing the work.  Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians.  WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way.  Comply with all traffic regulations of the City of Renton and the State of Washington.  Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices.  Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.  Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work.  Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions.  Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.  Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees.  The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.  In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same.  Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel.  All permit conditions shall be met. NOTES:  Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.  Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT.  Approved Temporary Traffic Control Plan must be at the work site during work hours.  Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone.  Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours.  Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021  In the case of Temporary No Parking Zones, all the following apply in addition to previous:  Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage.  Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time.  The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site.  Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) NOTES:1.ALL SPACING SHOWN IN FEET.2.CHANNELIZING DEVICES SPACING IS 20'O.C.3.RECOMMENDED EXTENDING CHANNELIZINGDEVICE TAPER ACROSS SHOULDER.4.KEEP DRIVEWAYS OPEN WHEN POSSIBLE5.THIS PLAN IS SUBJECT TO CHANGE TO MEETFIELD CONDITIONS.6.NON-FREEWAY SIGNS SPACING MAY BEMADE TO FIT FIELD DIMENSIONS SHOWN.7.PLACE APPROPRIATE SIGNS ON ALL SIDESTREETS.8.RESTRICTED SIGHT DISTANCES REQUIRESADDITIONAL ADVANCE WARNING DEVICEOR SIGNS.9.SIGNS ARE 48"x48" IN SIZE. CONES ARE ATLEAST 28" TALL.10.NIGHT WORK REQUIRES ADDITIONALROADWAY LIGHTING AT FLAGGINGSTATIONS.11.WORK VEHICLE LOCATED IN SAME AREA ASWORK LOCATION.12.POSTED SPEED: EQUIVALENT TO THEEXISTING, POSTED OR STATUTORY SPEED.13.ADHERE TO BICYCLE ACCOMMODATIONWHEN BICYCLE LANE IS PRESENT14.A SPOTTER IS REQUIRED TO ASSISTPEDESTRIANS AROUND WORK SITE.PEDESTRIAN ACCESS MUST REMAIN CLEARAT ALL TIMES.15.COORDINATE WITH THE FOLLOWING CITYDEPARTMENTS AT LEAST 48 HOURS INADVANCE: POLICE, FIRE, EMERGENCY,PUBLIC TRANSIT, PARKING.CURB LANE CLOSURE AT INTERSECTION, 5 LANE STREETFTINDICATE NORTHWORK SITE ADDRESS_____________________SHALL MAINTAIN 2-10' MINIMUMLANE WIDTHS AT ALL TIMES FOR2 WAY TRAFFIC OR 20' MINIMUMWIDTH FOR 2 WAY TRAFFIC ONSTREETS WITHOUT LANESTRIPING____________________________STREET NAME____________________________BETWEENFT = L___________________________ANDMERGING TAPER___________________________POSTED SPEEDFTALL LENGTHS ARE MINIMUMDISTANCES UNLESSOTHERWISE NOTEDFTDRAWING NOT TO SCALEFTPLACE SIGNS ON ALL SIDESTREETS, WITHIN THETRAFFIC CONTROL ZONESight distance shall be maintained at all public and private intersections and driveways. If sight distance is not achievable, prior approval by the TrafficEngineer is required to either restrict turn movements or use flaggers and shall include coordination with the affected property/business owner(s).(TCP REF)LC-113FTFTWORKZONE 350100100LIND AVE SWSW 29TH STSW 39TH ST35 MPH350350350245LIND AVE SWNTCP 1REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 11 08/22/2024 -- -- -- -- T AND A SUPPLY CO - 820 SW 41ST ST RENTON, WA 98057 CITY OF RENTON NTS JB-1903160 TRAFFIC CONTROL PLAN 1D. BAUTISTA T. SCHMITZ MFP24004381 NOTES:1.ALL SPACING SHOWN IN FEET.2.CHANNELIZING DEVICES SPACING IS 20'O.C.3.RECOMMENDED EXTENDING CHANNELIZINGDEVICE TAPER ACROSS SHOULDER.4.KEEP DRIVEWAYS OPEN WHEN POSSIBLE5.THIS PLAN IS SUBJECT TO CHANGE TO MEETFIELD CONDITIONS.6.NON-FREEWAY SIGNS SPACING MAY BEMADE TO FIT FIELD DIMENSIONS SHOWN.7.PLACE APPROPRIATE SIGNS ON ALL SIDESTREETS.8.RESTRICTED SIGHT DISTANCES REQUIRESADDITIONAL ADVANCE WARNING DEVICEOR SIGNS.9.SIGNS ARE 48"x48" IN SIZE. CONES ARE ATLEAST 28" TALL.10.NIGHT WORK REQUIRES ADDITIONALROADWAY LIGHTING AT FLAGGINGSTATIONS.11.WORK VEHICLE LOCATED IN SAME AREA ASWORK LOCATION.12.POSTED SPEED: EQUIVALENT TO THEEXISTING, POSTED OR STATUTORY SPEED.13.ADHERE TO BICYCLE ACCOMMODATIONWHEN BICYCLE LANE IS PRESENT14.A SPOTTER IS REQUIRED TO ASSISTPEDESTRIANS AROUND WORK SITE.PEDESTRIAN ACCESS MUST REMAIN CLEARAT ALL TIMES.15.COORDINATE WITH THE FOLLOWING CITYDEPARTMENTS AT LEAST 48 HOURS INADVANCE: POLICE, FIRE, EMERGENCY,PUBLIC TRANSIT, PARKING.SINGLE LANE CLOSURE CURB LANE, 4 LANE STREETFTDOWNSTREAM TAPER100 FT per lane maximumVARIABLE AS NEEDEDINDICATE NORTHWORK SITE ADDRESS_________________________________________________STREET NAME____________________________BETWEEN___________________________ANDBUFFER SPACEFTOPTIONAL___________________________POSTED SPEEDFT = LDRAWING NOT TO SCALEMERGING TAPERALL LENGTHS ARE MINIMUMDISTANCES UNLESSOTHERWISE NOTEDFTPLACE SIGNS ON ALL SIDESTREETS, WITHIN THETRAFFIC CONTROL ZONEFTFTSight distance shall be maintained at all public and private intersections and driveways. If sight distance is not achievable, prior approval by the TrafficEngineer is required to either restrict turn movements or use flaggers and shall include coordination with the affected property/business owner(s).(TCP REF)LC-102WORKZONELIND AVE SWSW 34TH STSW 39TH ST35 MPHLIND AVE SW350350350350245250NTCP 2REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 11 08/22/2024 -- -- -- -- T AND A SUPPLY CO - 820 SW 41ST ST RENTON, WA 98057 CITY OF RENTON NTS JB-1903160 TRAFFIC CONTROL PLAN 2D. BAUTISTA T. SCHMITZ MFP24004381 CURB LANE CLOSURE AT INTERSECTION, 5 LANE STREETFTINDICATE NORTHWORK SITE ADDRESS_____________________SHALL MAINTAIN 2-10' MINIMUMLANE WIDTHS AT ALL TIMES FOR2 WAY TRAFFIC OR 20' MINIMUMWIDTH FOR 2 WAY TRAFFIC ONSTREETS WITHOUT LANESTRIPING____________________________STREET NAME____________________________BETWEENFT = L___________________________ANDMERGING TAPER___________________________POSTED SPEEDFTALL LENGTHS ARE MINIMUMDISTANCES UNLESSOTHERWISE NOTEDFTDRAWING NOT TO SCALEFTPLACE SIGNS ON ALL SIDESTREETS, WITHIN THETRAFFIC CONTROL ZONESight distance shall be maintained at all public and private intersections and driveways. If sight distance is not achievable, prior approval by the TrafficEngineer is required to either restrict turn movements or use flaggers and shall include coordination with the affected property/business owner(s).(TCP REF)LC-113FTFTWORKZONENOTES:1.ALL SPACING SHOWN IN FEET.2.CHANNELIZING DEVICES SPACING IS 20'O.C.3.RECOMMENDED EXTENDING CHANNELIZINGDEVICE TAPER ACROSS SHOULDER.4.KEEP DRIVEWAYS OPEN WHEN POSSIBLE5.THIS PLAN IS SUBJECT TO CHANGE TO MEETFIELD CONDITIONS.6.NON-FREEWAY SIGNS SPACING MAY BEMADE TO FIT FIELD DIMENSIONS SHOWN.7.PLACE APPROPRIATE SIGNS ON ALL SIDESTREETS.8.RESTRICTED SIGHT DISTANCES REQUIRESADDITIONAL ADVANCE WARNING DEVICEOR SIGNS.9.SIGNS ARE 48"x48" IN SIZE. CONES ARE ATLEAST 28" TALL.10.NIGHT WORK REQUIRES ADDITIONALROADWAY LIGHTING AT FLAGGINGSTATIONS.11.WORK VEHICLE LOCATED IN SAME AREA ASWORK LOCATION.12.POSTED SPEED: EQUIVALENT TO THEEXISTING, POSTED OR STATUTORY SPEED.13.ADHERE TO BICYCLE ACCOMMODATIONWHEN BICYCLE LANE IS PRESENT14.A SPOTTER IS REQUIRED TO ASSISTPEDESTRIANS AROUND WORK SITE.PEDESTRIAN ACCESS MUST REMAIN CLEARAT ALL TIMES.15.COORDINATE WITH THE FOLLOWING CITYDEPARTMENTS AT LEAST 48 HOURS INADVANCE: POLICE, FIRE, EMERGENCY,PUBLIC TRANSIT, PARKING.350100100LIND AVE SWSW 34TH STSW 41TH ST35 MPH350350350245LIND AVE SWNTCP 3REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 11 08/22/2024 -- -- -- -- T AND A SUPPLY CO - 820 SW 41ST ST RENTON, WA 98057 CITY OF RENTON NTS JB-1903160 TRAFFIC CONTROL PLAN 3D. BAUTISTA T. SCHMITZ MFP24004381 NOTES:1.ALL SPACING SHOWN IN FEET.2.CHANNELIZING DEVICES SPACING IS 20'O.C.3.RECOMMENDED EXTENDING CHANNELIZINGDEVICE TAPER ACROSS SHOULDER.4.KEEP DRIVEWAYS OPEN WHEN POSSIBLE5.THIS PLAN IS SUBJECT TO CHANGE TO MEETFIELD CONDITIONS.6.NON-FREEWAY SIGNS SPACING MAY BEMADE TO FIT FIELD DIMENSIONS SHOWN.7.PLACE APPROPRIATE SIGNS ON ALL SIDESTREETS.8.RESTRICTED SIGHT DISTANCES REQUIRESADDITIONAL ADVANCE WARNING DEVICEOR SIGNS.9.SIGNS ARE 48"x48" IN SIZE. CONES ARE ATLEAST 28" TALL.10.NIGHT WORK REQUIRES ADDITIONALROADWAY LIGHTING AT FLAGGINGSTATIONS.11.WORK VEHICLE LOCATED IN SAME AREA ASWORK LOCATION.12.POSTED SPEED: EQUIVALENT TO THEEXISTING, POSTED OR STATUTORY SPEED.13.ADHERE TO BICYCLE ACCOMMODATIONWHEN BICYCLE LANE IS PRESENT14.A SPOTTER IS REQUIRED TO ASSISTPEDESTRIANS AROUND WORK SITE.PEDESTRIAN ACCESS MUST REMAIN CLEARAT ALL TIMES.15.COORDINATE WITH THE FOLLOWING CITYDEPARTMENTS AT LEAST 48 HOURS INADVANCE: POLICE, FIRE, EMERGENCY,PUBLIC TRANSIT, PARKING.THREE LANE TWO-WAY TRAFFIC WITH SHIFTING AND MERGINGINDICATE NORTHDRAWING NOT TO SCALE____________________________STREET NAME100 FT per lane maximumDOWNSTREAM TAPER____________________________BETWEEN___________________________ANDWORKZONEVARIABLE AS NEEDEDWORK SITE ADDRESS________________________________________________POSTED SPEEDBUFFER SPACEFTOPTIONALALL LENGTHS ARE MINIMUMDISTANCES UNLESSOTHERWISE NOTEDPLACE SIGNS ON ALL SIDESTREETS, WITHIN THECONTROL ZONEFTFTSight distance shall be maintained at all public and private intersections and driveways. If sight distance is not achievable, prior approval by the TrafficEngineer is required to either restrict turn movements or use flaggers and shall include coordination with the affected property/business owner(s).(TCP REF)LC-101 CUSTOM TEMPLATEFT = ½ LSHIFTING TAPERFT = LMERGING TAPERFTFTFT100 FT per lane maximumDOWNSTREAM TAPERSW 39TH STRAYMOND AVE SWLIND AVE SW25 MPHSW 39TH ST20020020012515580200200NTCP 4REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 11 08/22/2024 -- -- -- -- T AND A SUPPLY CO - 820 SW 41ST ST RENTON, WA 98057 CITY OF RENTON NTS JB-1903160 TRAFFIC CONTROL PLAN 4D. BAUTISTA T. SCHMITZ MFP24004381 NOTES:1.ALL SPACING SHOWN IN FEET.2.CHANNELIZING DEVICES SPACING IS 20'O.C.3.RECOMMENDED EXTENDING CHANNELIZINGDEVICE TAPER ACROSS SHOULDER.4.KEEP DRIVEWAYS OPEN WHEN POSSIBLE5.THIS PLAN IS SUBJECT TO CHANGE TO MEETFIELD CONDITIONS.6.NON-FREEWAY SIGNS SPACING MAY BEMADE TO FIT FIELD DIMENSIONS SHOWN.7.PLACE APPROPRIATE SIGNS ON ALL SIDESTREETS.8.RESTRICTED SIGHT DISTANCES REQUIRESADDITIONAL ADVANCE WARNING DEVICEOR SIGNS.9.SIGNS ARE 48"x48" IN SIZE. CONES ARE ATLEAST 28" TALL.10.NIGHT WORK REQUIRES ADDITIONALROADWAY LIGHTING AT FLAGGINGSTATIONS.11.WORK VEHICLE LOCATED IN SAME AREA ASWORK LOCATION.12.POSTED SPEED: EQUIVALENT TO THEEXISTING, POSTED OR STATUTORY SPEED.13.ADHERE TO BICYCLE ACCOMMODATIONWHEN BICYCLE LANE IS PRESENT14.A SPOTTER IS REQUIRED TO ASSISTPEDESTRIANS AROUND WORK SITE.PEDESTRIAN ACCESS MUST REMAIN CLEARAT ALL TIMES.15.COORDINATE WITH THE FOLLOWING CITYDEPARTMENTS AT LEAST 48 HOURS INADVANCE: POLICE, FIRE, EMERGENCY,PUBLIC TRANSIT, PARKING.WORK IN PARKING STRIP WITH MINOR ENCROACHMENT, INTERSECTIONDRAWING NOT TO SCALEINDICATE NORTHFTFTSHALL MAINTAIN 2-10' MINIMUMLANE WIDTHS AT ALL TIMES FOR2 WAY TRAFFIC OR 20' MINIMUMWIDTH FOR 2 WAY TRAFFIC ONSTREETS WITHOUT LANESTRIPINGSHALL MAINTAIN 10' MINIMUMLANE WIDTH AT ALL TIMESVARIABLE AS NEEDEDWORK SITE ADDRESS_________________________________________________STREET NAME____________________________BETWEEN___________________________AND___________________________POSTED SPEEDALL LENGTHS ARE MINIMUMDISTANCES UNLESSOTHERWISE NOTEDPLACE SIGNS ON ALL SIDESTREETS, WITHIN THETRAFFIC CONTROL ZONEBUFFER SPACEFTOPTIONALSight distance shall be maintained at all public and private intersections and driveways. If sight distance is not achievable, prior approval by the TrafficEngineer is required to either restrict turn movements or use flaggers and shall include coordination with the affected property/business owner(s).(TCP REF)SF-116WORKZONEFT = LMERGING TAPERFTFTFT200200200125155200200SW 39TH STOAKESDALE AVE SWLIND AVE SW25 MPHSW 39TH STNTCP 5REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 11 08/22/2024 -- -- -- -- T AND A SUPPLY CO - 820 SW 41ST ST RENTON, WA 98057 CITY OF RENTON NTS JB-1903160 TRAFFIC CONTROL PLAN 5D. BAUTISTA T. SCHMITZ MFP24004381 NOTES:1.ALL SPACING SHOWN IN FEET.2.CHANNELIZING DEVICES SPACING IS 20'O.C.3.RECOMMENDED EXTENDING CHANNELIZINGDEVICE TAPER ACROSS SHOULDER.4.KEEP DRIVEWAYS OPEN WHEN POSSIBLE5.THIS PLAN IS SUBJECT TO CHANGE TO MEETFIELD CONDITIONS.6.NON-FREEWAY SIGNS SPACING MAY BEMADE TO FIT FIELD DIMENSIONS SHOWN.7.PLACE APPROPRIATE SIGNS ON ALL SIDESTREETS.8.RESTRICTED SIGHT DISTANCES REQUIRESADDITIONAL ADVANCE WARNING DEVICEOR SIGNS.9.SIGNS ARE 48"x48" IN SIZE. CONES ARE ATLEAST 28" TALL.10.NIGHT WORK REQUIRES ADDITIONALROADWAY LIGHTING AT FLAGGINGSTATIONS.11.WORK VEHICLE LOCATED IN SAME AREA ASWORK LOCATION.12.POSTED SPEED: EQUIVALENT TO THEEXISTING, POSTED OR STATUTORY SPEED.13.ADHERE TO BICYCLE ACCOMMODATIONWHEN BICYCLE LANE IS PRESENT14.A SPOTTER IS REQUIRED TO ASSISTPEDESTRIANS AROUND WORK SITE.PEDESTRIAN ACCESS MUST REMAIN CLEARAT ALL TIMES.15.COORDINATE WITH THE FOLLOWING CITYDEPARTMENTS AT LEAST 48 HOURS INADVANCE: POLICE, FIRE, EMERGENCY,PUBLIC TRANSIT, PARKING.WORK IN SHOULDER WITH MINOR ENCROACHMENT – INTERSECTION,TWO WAY STREET WEST SIDEDRAWING NOT TO SCALEINDICATE NORTHFTFTVARIABLE AS NEEDEDWORK SITE ADDRESS_________________________________________________STREET NAME____________________________BETWEEN___________________________ANDSHALL MAINTAIN 10' MINIMUMLANE WIDTH AT ALL TIMES___________________________POSTED SPEEDALL LENGTHS ARE MINIMUMDISTANCES UNLESSOTHERWISE NOTEDFTPLACE SIGNS ON ALL SIDESTREETS, WITHIN THETRAFFIC CONTROL ZONESight distance shall be maintained at all public and private intersections and driveways. If sight distance is not achievable, prior approval by the TrafficEngineer is required to either restrict turn movements or use flaggers and shall include coordination with the affected property/business owner(s).(TCP REF)SF-118 CUSTOMWORKZONE100 FT per lane maximumDOWNSTREAM TAPER200200200RAYMOND AVE SWSW 39TH STSW 41ST ST25 MPHFT = ½ LSHIFTING TAPER80NTCP 6REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 11 08/22/2024 -- -- -- -- T AND A SUPPLY CO - 820 SW 41ST ST RENTON, WA 98057 CITY OF RENTON NTS JB-1903160 TRAFFIC CONTROL PLAN 6D. BAUTISTA T. SCHMITZ MFP24004381 SHIFTING PLAN, 2 LANE STREET WITH DELINEATIONFTINDICATE NORTHFT = ½ LSHALL MAINTAIN 10' MINIMUMLANE WIDTH AT ALL TIMES100 FT per lane maximumDOWNSTREAM TAPERVARIABLE AS NEEDEDWORK SITE ADDRESS_____________________BUFFER SPACEFT____________________________STREET NAME____________________________BETWEEN___________________________ANDOPTIONALFT = ½ LSHIFTING TAPER___________________________POSTED SPEEDOPTIONALALL LENGTHS ARE MINIMUMDISTANCES UNLESSOTHERWISE NOTEDFTPLACE SIGNS ON ALL SIDESTREETS, WITHIN THETRAFFIC CONTROL ZONEDRAWING NOT TO SCALEFTSight distance shall be maintained at all public and private intersections and driveways. If sight distance is not achievable, prior approval by the TrafficEngineer is required to either restrict turn movements or use flaggers and shall include coordination with the affected property/business owner(s).(TCP REF)SF-110WORKZONENOTES:1.ALL SPACING SHOWN IN FEET.2.CHANNELIZING DEVICES SPACING IS 20'O.C.3.RECOMMENDED EXTENDING CHANNELIZINGDEVICE TAPER ACROSS SHOULDER.4.KEEP DRIVEWAYS OPEN WHEN POSSIBLE5.THIS PLAN IS SUBJECT TO CHANGE TO MEETFIELD CONDITIONS.6.NON-FREEWAY SIGNS SPACING MAY BEMADE TO FIT FIELD DIMENSIONS SHOWN.7.PLACE APPROPRIATE SIGNS ON ALL SIDESTREETS.8.RESTRICTED SIGHT DISTANCES REQUIRESADDITIONAL ADVANCE WARNING DEVICEOR SIGNS.9.SIGNS ARE 48"x48" IN SIZE. CONES ARE ATLEAST 28" TALL.10.NIGHT WORK REQUIRES ADDITIONALROADWAY LIGHTING AT FLAGGINGSTATIONS.11.WORK VEHICLE LOCATED IN SAME AREA ASWORK LOCATION.12.POSTED SPEED: EQUIVALENT TO THEEXISTING, POSTED OR STATUTORY SPEED.13.ADHERE TO BICYCLE ACCOMMODATIONWHEN BICYCLE LANE IS PRESENT14.A SPOTTER IS REQUIRED TO ASSISTPEDESTRIANS AROUND WORK SITE.PEDESTRIAN ACCESS MUST REMAIN CLEARAT ALL TIMES.15.COORDINATE WITH THE FOLLOWING CITYDEPARTMENTS AT LEAST 48 HOURS INADVANCE: POLICE, FIRE, EMERGENCY,PUBLIC TRANSIT, PARKING.100RAYMOND AVE SWSW 39TH STSW 41ST ST25 MPH2008015580200200RAYMOND AVE SWNTCP 7REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 11 08/22/2024 -- -- -- -- T AND A SUPPLY CO - 820 SW 41ST ST RENTON, WA 98057 CITY OF RENTON NTS JB-1903160 TRAFFIC CONTROL PLAN 7D. BAUTISTA T. SCHMITZ MFP24004381 CURB LANE CLOSURE AT INTERSECTION, 5 LANE STREETFTINDICATE NORTHWORK SITE ADDRESS_____________________SHALL MAINTAIN 2-10' MINIMUMLANE WIDTHS AT ALL TIMES FOR2 WAY TRAFFIC OR 20' MINIMUMWIDTH FOR 2 WAY TRAFFIC ONSTREETS WITHOUT LANESTRIPING____________________________STREET NAME____________________________BETWEENFT = L___________________________ANDMERGING TAPER___________________________POSTED SPEEDFTALL LENGTHS ARE MINIMUMDISTANCES UNLESSOTHERWISE NOTEDFTDRAWING NOT TO SCALEFTPLACE SIGNS ON ALL SIDESTREETS, WITHIN THETRAFFIC CONTROL ZONESight distance shall be maintained at all public and private intersections and driveways. If sight distance is not achievable, prior approval by the TrafficEngineer is required to either restrict turn movements or use flaggers and shall include coordination with the affected property/business owner(s).(TCP REF)LC-113FTWORKZONENOTES:1.ALL SPACING SHOWN IN FEET.2.CHANNELIZING DEVICES SPACING IS 20'O.C.3.RECOMMENDED EXTENDING CHANNELIZINGDEVICE TAPER ACROSS SHOULDER.4.KEEP DRIVEWAYS OPEN WHEN POSSIBLE5.THIS PLAN IS SUBJECT TO CHANGE TO MEETFIELD CONDITIONS.6.NON-FREEWAY SIGNS SPACING MAY BEMADE TO FIT FIELD DIMENSIONS SHOWN.7.PLACE APPROPRIATE SIGNS ON ALL SIDESTREETS.8.RESTRICTED SIGHT DISTANCES REQUIRESADDITIONAL ADVANCE WARNING DEVICEOR SIGNS.9.SIGNS ARE 48"x48" IN SIZE. CONES ARE ATLEAST 28" TALL.10.NIGHT WORK REQUIRES ADDITIONALROADWAY LIGHTING AT FLAGGINGSTATIONS.11.WORK VEHICLE LOCATED IN SAME AREA ASWORK LOCATION.12.POSTED SPEED: EQUIVALENT TO THEEXISTING, POSTED OR STATUTORY SPEED.13.ADHERE TO BICYCLE ACCOMMODATIONWHEN BICYCLE LANE IS PRESENT14.A SPOTTER IS REQUIRED TO ASSISTPEDESTRIANS AROUND WORK SITE.PEDESTRIAN ACCESS MUST REMAIN CLEARAT ALL TIMES.15.COORDINATE WITH THE FOLLOWING CITYDEPARTMENTS AT LEAST 48 HOURS INADVANCE: POLICE, FIRE, EMERGENCY,PUBLIC TRANSIT, PARKING.200200 200200200125LIND AVE SWSW 41ST STOAKESDALE AVE SWLIND AVE SW25 MPHNTCP 8REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 11 08/22/2024 -- -- -- -- T AND A SUPPLY CO - 820 SW 41ST ST RENTON, WA 98057 CITY OF RENTON NTS JB-1903160 TRAFFIC CONTROL PLAN 8D. BAUTISTA T. SCHMITZ MFP24004381 NOTES:1.ALL SPACING SHOWN IN FEET.2.CHANNELIZING DEVICES SPACING IS 20'O.C.3.RECOMMENDED EXTENDING CHANNELIZINGDEVICE TAPER ACROSS SHOULDER.4.KEEP DRIVEWAYS OPEN WHEN POSSIBLE5.THIS PLAN IS SUBJECT TO CHANGE TO MEETFIELD CONDITIONS.6.NON-FREEWAY SIGNS SPACING MAY BEMADE TO FIT FIELD DIMENSIONS SHOWN.7.PLACE APPROPRIATE SIGNS ON ALL SIDESTREETS.8.RESTRICTED SIGHT DISTANCES REQUIRESADDITIONAL ADVANCE WARNING DEVICEOR SIGNS.9.SIGNS ARE 48"x48" IN SIZE. CONES ARE ATLEAST 28" TALL.10.NIGHT WORK REQUIRES ADDITIONALROADWAY LIGHTING AT FLAGGINGSTATIONS.11.WORK VEHICLE LOCATED IN SAME AREA ASWORK LOCATION.12.POSTED SPEED: EQUIVALENT TO THEEXISTING, POSTED OR STATUTORY SPEED.13.ADHERE TO BICYCLE ACCOMMODATIONWHEN BICYCLE LANE IS PRESENT14.A SPOTTER IS REQUIRED TO ASSISTPEDESTRIANS AROUND WORK SITE.PEDESTRIAN ACCESS MUST REMAIN CLEARAT ALL TIMES.15.COORDINATE WITH THE FOLLOWING CITYDEPARTMENTS AT LEAST 48 HOURS INADVANCE: POLICE, FIRE, EMERGENCY,PUBLIC TRANSIT, PARKING.SINGLE LANE CLOSURE CURB LANE, 4 LANE STREETFTDOWNSTREAM TAPER100 FT per lane maximumVARIABLE AS NEEDEDINDICATE NORTHWORK SITE ADDRESS_________________________________________________STREET NAME____________________________BETWEEN___________________________ANDBUFFER SPACEFTOPTIONAL___________________________POSTED SPEEDFT = LDRAWING NOT TO SCALEMERGING TAPERALL LENGTHS ARE MINIMUMDISTANCES UNLESSOTHERWISE NOTEDFTPLACE SIGNS ON ALL SIDESTREETS, WITHIN THETRAFFIC CONTROL ZONEFTFTSight distance shall be maintained at all public and private intersections and driveways. If sight distance is not achievable, prior approval by the TrafficEngineer is required to either restrict turn movements or use flaggers and shall include coordination with the affected property/business owner(s).(TCP REF)LC-102WORKZONESW 41ST STOAKESDALE AVE SWRAYMOND AVE SW25 MPH200200200200125155SW 41ST STNTCP 9REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 11 08/22/2024 -- -- -- -- T AND A SUPPLY CO - 820 SW 41ST ST RENTON, WA 98057 CITY OF RENTON NTS JB-1903160 TRAFFIC CONTROL PLAN 9D. BAUTISTA T. SCHMITZ MFP24004381 BICYCLE ACCOMMODATIONREVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 11 08/22/2024 -- -- -- -- T AND A SUPPLY CO - 820 SW 41ST ST RENTON, WA 98057 CITY OF RENTON NTS JB-1903160 TRAFFIC CONTROL PLAN 10D. BAUTISTA T. SCHMITZ MFP24004381 PEDESTRIAN ACCOMMODATIONREVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 11 08/22/2024 -- -- -- -- T AND A SUPPLY CO - 820 SW 41ST ST RENTON, WA 98057 CITY OF RENTON NTS JB-1903160 TRAFFIC CONTROL PLAN 11D. BAUTISTA T. SCHMITZ MFP24004381 VVAT (E) VAULT:(E) SPLICE CASEAT (E) VAULT:(E) SPLICE CASESW 34TH STLIND AVE SWLEGENDLINETYPESNEW CONDUITEXISTING CONDUITSYMBOLS(E) PEDESTALADDRESS###LOT LINESROAD EDGERAILROAD(E) VAULTVLINETYPES LEGEND:SYMBOL LEGEND:STORM DRAINSDSDSDSD#"Ø CONDUIT TYPEWATERWWWW#"Ø CONDUIT TYPEFIRE HYDRANTWATER MANHOLE / VALVEW W FH 34003600TRAFFIC PLAN1TRAFFIC PLAN2BN S F(N) VAULTVLABORUNDERGROUND: BORE/TRENCH =1001'ROD & ROPE =727'TOTAL UG FOOTAGES =1728'PERMITS TO BE SUBMITTED:CITY OF RENTONBSNFTRAFFIC CONTROL PLAN1 NAP 1REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE:D. BAUTISTA A. GENTRY 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 2 10/08/2024 -- -- -- -- T AND A SUPPLY CO 820 SW 41ST ST RENTON, WA 98057 CITY OF RENTON APPROACH PLAN NTS JB-1903160 MFP24004381This permit is for Major construction work in the ROW and will be billed at an additional$158/HR for inspections. After hours and weekend work will be billed at $175/HR VAT (E) VAULT:(E) SPLICE CASEAT (E) PED:(E) SPLICE CASE(N) 96CT FIBER TIE IN POINTVVSW 39TH STSW 41ST STLIND AVE SW RAYMOND AVE SWVV (OP)'657(OP)'70'(N) B/T12'(N) B/T90'(N) B/T290'(N) B/T569'(N) B/T40GENERAL NOTESALL PEDS/VAULTS ARE (E)UNLESS OTHERWISE STATEDWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW W W W W W W W W W W W W F F F F F F SDSDSDSDSDSDSDSDSDSDSDSDSDSDSD SD SDSDSDSDSDSDSDSDSDSD SD SD SD SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDTHE LOCATIONS OF THE UTILITIES SHOWNON THESES PLANS ARE APPROXIMATE. ALLUTILITY LOCATIONS SHALL BE VERIFIEDPRIOR TO CONSTRUCTION. CALL BEFOREYOU DIGSYMBOL REPRESENTSPOTHOLING LOCATIONSPECIFIC NOTE:CONSTRUCTION NOTE: PLACE (N) VAULT53'2'27'17'70'14'WW3600800500TRAFFIC PLAN3TRAFFIC PLAN4TRAFFIC PLAN5TRAFFIC PLAN6TRAFFIC PLAN8TRAFFIC PLAN9BNSF29'AT (N) VAULT:PLACE (N) SPLICE CASE(N) 48CT FIBER TIE POINTTRAFFIC PLAN72 NAP 2REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE:D. BAUTISTA A. GENTRY 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 2 10/08/2024 -- -- -- -- T AND A SUPPLY CO 820 SW 41ST ST RENTON, WA 98057 CITY OF RENTON APPROACH PLAN NTS JB-1903160New vaults to be installedbehind the sidewalk in softsurface.MFP24004381RESTORATION PER CITY OF RENTON STANDARDS