HomeMy WebLinkAboutR-428002o
o
p
�
ABBREVIATIONS
L
a
�
R
ANGLE
AT
CENTERLINE
pL,q TF
FG
FT
HT
LB
FINISH GRADE
FEET
HEIGHT
POUND
GENERAL
1.
2,
REQUIREMENTS
REVIEW (E) COND1770NS PRIOR TO SUBMlT71NG BID. ACCEPT
THEM ",4S-lS".
ALL WORK SHALL COMPLY W/ CURRENT ED1770NS OF
APPLICABLE CODES
EXISTING
1.
2
CONDITIONS
THE DRAWINGS CONTAIN REFERENCES TO EXIS77NG
CONDIAONS THE BUILDING IS NOT LEVEL, SQUARE OR
PLUMB.
CONTRACTOR SHALL REVIEW EXIS77NG COND1710NS PRIOR
TO SUBMlT7ING ABID.
co
o
co
U
NUMBER -INCH
LOC
LOCATION
J.
PROVIDE ALL WORK COMPLETE AND OPERA170NAL.
LT
LIGHT
J.
SUBMITTING A BID INDICATES CONTRACTORS
#'
NUMBER -FOOT
4•
DO NOT SCALE DRAN9NGS.
ACCEPTANCE OF THE EXIS77NG CONDITIONS AND
0
DIAMETER
MAX
MAXIMUM
AGREEMENT TO PROVIDE WORK W1774lN THE CONDITIONS
MIN
MINIMUM
5.
BRING CONFLICTS, OMISSIONS AND INCONSISTENCIES FOUND
PROVIDED.
�
ACP
ASPHALT CONCRETE
IN CONTRACT DOCUMENTS TO ATTENAON OF ARCHITECT
o
PAVEMENT
NO
NUMBER
IMMEDIATELY. REFER TO GENERAL CONDITIONS FOR
OC
ON CENTER
ADD1710NAL REQUIREMENTS
o
ALUM
ALUMINUM
p
PORTABLE
EXISTING
UT�UT�ES
BLD
BUILDING
6.
PROVIDE NEW MATERIALS &EQUIPMENT UNLESS OINERWISE
<'�
N
PAR
PARCEL
NOTED.
cc
BLT
BUILT
PROM
PROME774EAN
1.
ALL UNDERGROUND U71U77ES ARE NOT SHOWM CONTRACTOR
B
CATCH BASIN
7.
FOLLOW MANUFACTURERS INSTALLAAON lNS7RUC710NS
SHALL LOCATE ALL UNDERGROUND UAUAES PRIOR TO
R
RADIUS
UNLESS MORE STRINGENT REQUIREMENTS ARE N07E0 OR
COMMENCEMENT OF WORK. CONTACT JHE UNDERGROUND
BF
BARRIER FREE
REQ
REQUIRED
REQUIRED BY CODE.
LOCATION SERVICE O 1-800-424-5555 O LEAST 48 HOURS
CJ
CONTROL JOINT
PRIOR TO COMMENCEMENT OF WORK.
SD
STORM DRAIN
8.
FIELD VERIFY ALL (E) CONDITIONS &ROUGH OPENINGS
CONIC
CONCRETE
SF
SQUARE FEET
PRIOR TO FABRICATION AND LAYOUT OF WORK. NOTIFY
COR-1
CITY OF RENTON
ARCHITECT OF CONFLICTS IMMEDIATELY.
REVISION #
TYP
TYPICAL
9.
NOT ALL WORK INDICATED ON PLANS, INCLUDING CUTI7NG
CODES
N
CONST
CONS7RUC710N
&PATCHING
CONT
CON77N000S
W
w/
WIDE
W�
10.
CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING
1.
INTERNA AONAL BUILDING CODE (IBC), 2018 EDI AON
WASHINGTON STATE AMENDMENTS WAC 51-50
o
p
DEMO
DEMOUAON
SCOPE OF ALL CUTTING, PATCHING, FlT17NG &
DIM
DIMENSION
W8
WHITE BOARD
RESTORATION WORK REQUIRED FOR INSTALLA770N &
2
/NTERNAAONAL CODE COUNCIL (ICC), 2009 ICC A117.1
<'�
c�
WWF
WELDED WIRE FABRIC
COMPLEAON OF ALL WORK.
Q
DN
DOWN
11.
COORDINATE DEMOLITION WITH NEW WORK
J.
lN7ERNAAONAL MECHANICAL CODE (lMC), 2018 EDIAON
J
OS
DOWNSPOUT
WASHINGTON STATE AMENDMENTS WAC 51-52
(E)
EXIS77NG
12.
TAKE MEASURES TO PROTECT (E) COND1770NS.
4,
UNIFORM PLUMBING CODE (UPC), 2018 EDIAON WASHINGTON
EA
EACH
13.
REPAIR DAMAGE TO (E) CONDIAONS TO LIKE OR BETTER
STATE AMENDMENTS WAC 51-56 & WAC 51-57
FH
FIRE HYDRANT
CONDI770N THAN THOSE (E) PRIOR TO COMMENCEMENT OF
5.
INTERNAAONAL FIRE CODE (lFC), 2018 EDIAON WASHINGTON
FCIC
FOR CALLOUTS IN
ARK
STATE AMENDMENTS WAC 51-44
COMMON
14.
UAUTY Bc SERVICES IN7ERUP770NS SHALL OCCUR AFTER
6.
NAAONAL ELECTRICAL CODE (NEC), 2018 EDIAON
NORMAL BUSINESS &SHALL BE OPERA770NAL THE NEXT
BUSINESS DAY.
7.
ACCESSIBILITY CODE WAC 51-50
15.
PROVIDE TEMPORARY MEASURES TO MAINTAIN UAUAES &
8.
WASHINGTON STATE ENERGY CODE WAC 51-11, 2020 EDIAON
SERVICES OPERATIONAL WHEN NECESSARY.
16.
PROTECT PERSON, PROPERTY & (E) COND1770NS FROM
*
ALL REFERENCE CODES SHALL INCORPORATE CURRENT STATE
&LOCAL AMENDMENTS
INJURY &DAMAGE.
1 Z PERFORM ALL WORK EXCAVATION, BACKFILL, COMPACTION,
& RESTORATION REQUIRED TO COMPLETE WORK.
18. FILL DEPRESSIONS LEFT BY REMOVAL OF STUMPS, DEBRIS,
EXCAVATIONS & ALL REMOVED IMPROVEMENTS.
19. RESTORE ALL STM SWR, SAN SWR, WATER, GAS &
IRRIGATION LINES ACCESSORIES & APPURTENANCES
DAMAGED BY WORK.
20. PROVIDE TEMPORARY PROTECTION DEVICES TO KEEP (E)
BLD & MODULAR BLD WEA THERTIGHT & WA TERTIGHT A T
ALL TIMES
21. RESTORE (E) LAWNS, (E) PLANTING BEDS, AND (E)
HARDSCAPE AFFECTED BY WORK TO MATCH COND1 TIONS
(E) PRIOR TO START OF WORK
22. REPAIR (E) IRRIGATION SYSTEM AFFECTED BY WORK
CONSTRUCTION RECORD DRAWING
THIS CONSTRUCTION RECORD DRAWING IS A COPY OF A CAD FILE
PREPARED BY JACOBSON CONSULTING ENGINEERS, AND HAS BEEN
EDITED TO REFLECT THE AS -BUILT CONDITIONS OF THE PROJECT.
FIELD DIMENSIONS AND INFORMATION WAS PROVIDED BY MOECO,
AND PROVIDED TO JACOBSON CONSULTING ENGINEERS IN AUGUST
2025. JACOBSON CONSULTING ENGINEERS DOES NOT PROVIDE ANY
WARRANTY AS TO THE ACCURACY OR COMPLETENESS OF SUCH
INFORMATION PROVIDED BY OTHERS.
R-428002
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
�il ov1 SURVEYED: SCALE: HAZEN HIGH SCHOOL DATEI o 8 z5
COP-1 /22/23 ��,�: NAVE) 1988
�� CIVIL PERMIT SUBMITTAL /12/23 1"=10' HORIZONTAL: NAD 1983/1991 F CITY OF / / DESIGNED: FIELDBOOK:
CIVIL PERMIT RESUBMITTAL 1/30/23 SSE RENTON PAGE:
�C CITY AS -BUILT REVIEW 8/12/2 DRAW DJD ONE INCH SITEWORK FOR PORTABLE CLASSROOMS
DRAWING N0:
i�, IS-Fi �� CITY AS -BUILT REVIEW RESUBMITTAL 0/17/25 CHECKED: AT FULL SCALE DATUM GENERAL INFORMATIONA002
�CJACOBSON ����NAL ���� APPROVED: SIF NOT ONE INCH CALE ACCORDINGLY Planning/Building/Public Works Dept. SHEEP: OF:
CONSULTING ENGINEERS 10/I7/25 NO. REVISION BY DATE APPR JAJ 2 OF 9
PERMIT/PRICING REVIEW SET