HomeMy WebLinkAboutzR-4280set00 HA7EN HIGH SCHOOL w vqk IT XA/n K Fn F ral AwqwqRnnK/I � CIVIL PERMIT PROJECT INFORMATION PROJECT SUMMARY INSTALL FOUR DOUBLE CLASSROOM PORTABLES. WORK INCLUDES BUT IS NOT LIMITED TO RAMPS, STAIRS, ELECTRICAL SYSTEMS AND RELATED SITE WORK. ALL ANALYSIS IS BASED ON THE SUBJECT PARCEL SITE AREA AREA (SUBJECT PARCEL) 178,596 SF SQUARE FOOTAGE OF EACH BUILDING AND/OR USE BLD—A BLD—B BLD—C BLD—D BLD-1 (EXISTING) BLD-4 (EXISTING) 1,792 SF SINGLE STORY 1,792 SF SINGLE STORY 1,792 SF SINGLE STORY 1,792 SF SINGLE STORY 60,782 SF TWO STORY 23,395 SF TWO STORY * ALL BUILDINGS ARE EDUCATIONAL USE TOTAL SQUARE FOOTAGE OF ALL BUILDINGS (FOOTPRINT) BLD—A BLD—B BLD—C BLD—D BLD-1 (EXISTING) BLD-4 (EXISTING) TOTAL PERCENT OF LOT COVERAGE 1,792 SF 1,792 SF 1,792 SF 1,792 SF 30,391 SF 23.395 SF 60,954 SF PERCENT = 30.11 (53,786 SF / 178,596 SF) SQUARE FOOTAGE (EXISTING) OF ALL LANDSCAPING AREA 34,774 SF ALLOWABLE & PROPOSED BUILDING HEIGHTS ALLOWABLE BUILDING HEIGHT: PROPOSED BUILDING HEIGHT: 3 06 0 N 1 M N N J m 9 0. N z W a x 0 rn J m a 0 a U) z W a x 0 M N N U) z 0 z Q 0 0 z z W U N f" a i U W O a 0 z z J 24 FEET (WALL PLATE) 16 FEET (TOP OF RIDGE) greenegasaway PO BOX 4158 FEDERAL WAY, WA. 98063 TEL: 253-941-4937 BUILDING SETBACKS REQUIRED BY CODE FRONT YARD SIDE YARD REAR YARD PROPOSED BUILDING SETBACKS FRONT YARD SIDE YARD REAR YARD PARKING ANALYSIS REQUIRED PARKING 20 FEET 5 FEET 25 FEET 269 FEET 67 FEET 223 FEET REQ COUNT REQ 1 PER EMPLOYEE 155 155 1 PER 10 STUDENTS 1,694 170 TOTAL 325 * COUNTS INCLUDE ADDITIONAL STAFF & STUDENTS (E) PARKING STALL STATUS GENERAL ACCESSIBLE VAN ACCESSIBLE TOTAL REMOVED STALLS GENERAL ACCESSIBLE VAN ACCESSIBLE TOTAL REVISED PARKING STALL COUNT GENERAL ACCESSIBLE VAN ACCESSIBLE TOTAL BIKE RACKS REQUIRED EXISTING ADDED TOTAL REFUSE & RECYCLE REFUSE RECYCLE 446 3 16 465 51 0 :J I 395 3 16 414 33 (325 x 0.10 = 32.5) 16 18 34 30 CY DUMPSTER 30 CY DUMPSTER * SCREENED ON EAST SIDE BY EXISTING LANDSCAPING CONTACTS OWNER RENTON SCHOOL DISTRICT NO. 403 7812 S 124TH STREET SEATTLE, WA. 98178 CONTACT: MIKE CATO TELEPHONE: 425.204.4473 EMAIL: michael.cato@rentonschools.us ARCHITECT GREENE—GASAWAY ARCHITECTS PO BOX 4158 FEDERAL WAY, WA 98063-4158 CONTACT: CALVIN GASAWAY TELEPHONE: (253) 941-4937 EMAIL: calvin@greenegasaway.com JACOBSON CONSULTING ENGINEERS 815 1ST AVE S #288 SEATTLE, WA 98104 CONTACT: ALAN JACOBSON TELEPHONE: 206.399.6233 EMAIL: alan@jacobsonengineers.com LANDSCAPE SCJ ALLIANCE 8730 TALLEN LANE NE SUITE 200 LACEY, WA 98516 CANTACT: JEFF GLANDER TELEPHONE: 360.951.5136 EMAIL: jeff.glander@scjalliance.com ELECTRICAL METRIX ENGINEERS 227 WILLIAMS AVE S RENTON, WA 98057 CONTACT: BEN PREHODA TELEPHONE: 425.336.2822 EMAIL: benp@metrixeng.com PORTABLE CLASSROOM ARIES BUILDING SYSTEMS 4122 FACTORIA BLVD STE 402 BELLEVUE, WA 98006 CONTACT: STEVE YAN TZER TELEPHONE: 253.355.9830 EMAIL: syantzer@ariesbuildings.com RAMPS/STAIRS/LANDINGS WELCOME RAMP SYSTEMS 3902 B ST NW SUITE B AUBURN, WA 98001 CONTACT: SVEN BJERKHOEL TELEPHONE: 303.514.7836 EMAIL: s.bjerkhoel@welcomerampsystems.com SPR APPLICATION 3/22/23 SURVEYED: SCALE: VERTICAL- NAVD 1988 BUILDING PERMIT 4/4/23 NA HORIZONTAL NAD 1983/1991 DESIGNED: COP-1 5/22/23 CIS PERMIT SUBMITTAL 8/29/23 DRAWN: PDS ONE INCH DATUM CIVIL PERMIT SUBMITTAL 11/30/23 CHECKED: CG AT FULL SCALE IF NOT ONE INCH N 0. REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY CG 2023 VICINITY MAP LOCATION 1 IUI r1`JVUI/AIVI /HVL INt I\LJVL_V RENTON, WA 98059 SITE INDEX ARCHITECTURAL A001 GENERAL INFORMATION A002 GENERAL INFORMATION CIVIL C100 DEMOLITION PLAN C200 GRADING & PAVING PLAN C300 HORIZONTAL CONTROL PLAN C400 UTILITY & DRAINAGE PLAN C500 FIRE PLAN C510 SITE DETAILS C TY OF 9;R] RENTON Planning/Building/Public Works Dept. R-428001 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING REGIONAL FIRE AUTHORITY APPROVED �t' p SAMorman 01 /12/2024 cthomas 01/16/2024 °y4<F,REp�.� SURFACE WATER UTILITY WATER UTILITY �' # ABDOUL GAFOUR 01/12/2024 jfarah 02/01 /2024 DATE: HAZEN HIGH SCHOOL 6/22/23 FIELDBOOK: PAGE: SITEWORK FOR PORTABLE CLASSROOMS DRAWING NO: GENERAL INFORMATION A001 SHEET: 1 OF 8 00 O O co N [i] BOO co 0- H • H co Q J 6 0 co SAWCUT AND REMOVE O' EXISTING ASPHALT TO C) INSTALL NEW FIRE HYDRANT (45 SF LOCATED OVER Q WATER MAIN TAP - SEE Lij SHEET C400) SAWCUT AND REMOVE EXISTING ASPHALT TO INSTALL NEW FIRE HYDRANT l - \\ GG 1 � \ I mob= — — — -- \ I \ I \ I U U 03 .-oJ" — — — — cn o_ I 00 9° 001 — — — — — — — — �\ I I I i I I I I I I 1❑ I I I I I I I I I I I I I I I I 1 LSCAPE I I I I I J Al 8.c c 1 � CB 4 RIM:65.08' 8"IM:2.0o INSTALL CB PROTECTION r B :459.6' AT ALL CATCH BASINS IN VICINITY OF PORTABLE INSTALLATION (TYP) yl IP �I SwALt II I I I I _466— II I II I I I I I I II o REMOVE EX III I I I LIGHT POLE II 0 \\ I I I I AND SALVAGE TO OWNER II I I I 20 CON T I I I I o II I I I I I I LSCAPE I I I I I I III I REMOVE EXI I I I I I ISPEED BUMPI I I 166p� n°6I � n66�1 I I I I 8"CC 66, SAWCUT AND REMOVE *OVER RECORD VAULT LOCATION EXISTING ASPHALT TO / INSTALL NEW ELECTRICAL / AND COMMUNICATION / LINES (TYP) J / SEE ELECTRICAL PLANS FOR DETAILED CONDUIT SwAI F — SD— _ SD SD_ AND VAULT INFORMATION. �656° I I I I I t I J r I \ I STORM WATER QUALITY 17-P I VAULT GRATE RIM:465.41' I I I *FILTER` cb � I REMOVE EX I J 466 LIGHT POLE AND SALVAG I TO OWNER I I I I I I I I I II I I I I I I II 1I5' UTILITY EASEMEL I \EC. 0. 2006030300092u I L 1----L----L--------I-----I I I I I I I I I I I I I I I I\ 71PF LANE STRIPE "BIO CLEAN" SDMH RIM•465 38' 466I � I - /_FF I *FILLED WITH WATER I / INSTALL CB CB RIM:465.92' PROTECTION IE 8"DI(S):464.20' -— — — — — — — — — — — — — — — — — — — — — — — — — — — — --- i i—PS��------------ �— — — — — ---i — — — — — i BTM: 46t2' LL I PROPOSED PORTABLES TO \ / N I BE LOCATED ON TOP OF o I I EXISTING ASPHALT (TYP) 11 RN 605 II I I I I 146, I I \ I I I I I I I I I I I I ¢s I I I I I II I I I I I I II �I� I I I I I I / 1 "co ------L--—----L----I---------�I I---��---1----L----L----L �, Fa I69 ---I I I I I \ I I I I I I I —'j— II I I I I I I I \ I I I I I I I I I I I I I I II I \ I I I I I I I I I I I I I 16'coOCD n66 I I I I o I I I I F o SOL LID CB RIM:466.41' o CB RIM:465.83' IE 8"PE ):462.10' i IE 8"DI(N):463.20' IE 8"PE(SE): 2.10' IE 8"DI(E):463.10' IE 8"DI(W):462. F GRIND AND REMOVE CB 6TM:460.6' EXISTING PARKING \ 8"PEIN1:46225' INLET RIM:465.92' IE 3"IP ELBOW \ I TRAP(SE):464.30'(R) -A \ I BTM: 461.3'(R) � \ \ / I I\ IP STALL STRIPING \ BTM:459.55' \ �SOUTH OF PROPOSED \ / FA SD PORTABLES (TYP) /� `� i / m W w / h61 jti o �o 14—P� I I D D D od00000000 D iD D • D D .' L 00 D— JACOBSON CONSULTING ENGINEERS ti 43667 lS rt Cs� SPR APPLICATION BUILDING PERMIT 1 COP-1 CIVIL PERMIT SUBMITTAL CIVIL PERMIT RESUBMITTAL NO. REVISION 3/22/23 SURVEYED: /4/23 DESIGNED: SSE /22/23 /12/23 DRAWN. DJD 1/30/2 CHECKED: SSE BY DATE APPR APPROVED: JAJ SCALE: 1"=10' ONE INCH AT FULL SCN_E IF NOT ONE INCH SCALE ACCORDINGLY VERnCAL• NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM Call before you — — — Dag.8-I-I or1-800-424-5555 UNDERGROUND 8"CC 0 5 10 20 SERVICE (U A) CO • O I SCALE 1 " =10' o I N LEGEND v \ SIGN PROPERTY LINE N 7933'06" E - 46.81' � — — w T I � SD SDI SD SD �66\ SAWCUT LINE - — — — — — — — - I INLET PROTECTION IP I DEMO ASPHALT co I I I 12"C N I O Q O ( I HAZEN HIGH _ — I /------StH@6tIMN DD _ — co / GARDEN" N RD r� I EXISTING WATER /� D: v Ir CAN I I MAIN EASEMENT J TR H / TOP DD D 2 // \I SECURITY b ` 0� I CAME D — I___ i ; CITY OF 'R RENTON Planning/Building/Public Works Dept. G I I I I I ) I I ' I I \v i SAWCUT AND REMOVE EXISTING ASPHALT TO INSTALL NEW ELECTRICAL AND COMMUNICATION LINES (TYP) SEE ELECTRICAL PLANS FOR DETAILED CONDUIT AND VAULT INFORMATION. 1CrAF' PPE: MASC. ASPHALT REPLACEMENT LEGEND DESCRIPTION QUANTITY UNIT UTILITY REPLACED 1 ,995 SF ASPHALT R-428003 L\ IN COMPLIANCE WITH CITY OF RENTON STANDARDS IELOPMENT ENGINEERING ` �Morman 01 /12/2024 %J DATE: HAZEN HIGH SCHOOL 11/30/23 FIELDBOOK: PAGE: SITEWORK FOR PORTABLE CLASSROOMS DRAWING NO: DEMOLITION PLAN C1 OO SHEET: OF, 3 OF 8 I— cy) Q J PERMIT/PRICING REVIEW SET C'7 00 Nt O O CM N A u C'7 CV rr n H H C'7 N Q D J PERMIT/PRICING REVIEW SET C'7 00 C) C) CM N Al u 00 (9 C) C) C) C) N rr ,a H • H C'7 CV Q J PERMIT/PRICING REVIEW SET C'7 00 C) C) CM N Al u 00 (9 C) C) C) C) N rr ,a H • H C'7 CV Q J PERMIT/PRICING REVIEW SET C'7 00 C) C) CM N Al u 00 (9 C) C) C) C) N rr ,a H • H C'7 CV Q J PERMIT/PRICING REVIEW SET DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DRAINAGE GRATE GRATE FRAME -� SEDIMENT AND DEBRIS DRAINAGE GRATE (RECTANGULAR GRATE SHOWN) BELOW INLET GRATE DEVICE FILTERED WATER - 5" MAX. TRIM a OVERFLOW BYPASS BELOW INLET GRATE DEVICE ;u ISOMETRIC VIEW RETRIEVAL SYSTEM (TYP.) OVERFLOW BYPASS (TYP.) NOTES: 1. PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2. INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE. 5. THE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS). 6. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION B-01.3(15). 8. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 216.30 .} PUBLIC WORKS APPR ED: DEPARTMENT CATCH BASIN INSERT GAZ 9/28/2018 Public Works Adminirtm DATE NTS Catch Basin Insert DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL (ESC) PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES. 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2. THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT. 3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4. THE BOUNDARIES OF THE CLEARING LIMITS SENSITIVE AREAS AND THEIR BUFFERS AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. 6. WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF -SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON -SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT AREAS. 7. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. 8. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY. 9. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM, 10. APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR STORMWATER FACILITIES. 11. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. 13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY. 14. ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. 15. THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY. 16. BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM. 18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. 19. AREAS DESIGNATED ON THE PLANS CONTAINING EXISTING STORMWATER FACILITIES OR ON -SITE BMPS AMENDED SOILS BIORETENTION PERMEABLE PAVEMENT ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION. 20. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. 21. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVING THE PROJECT SITE, ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON -SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM, DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST. 22. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 268.00 •�a PUBLIC WORKS EROSION AND SEDIMENT CONTROL [PROVED: '�1� DEPARTMENT STANDARD PLAN NOTES GAZ 9/28/2018 Public Works Admi' w-, DATE TESTING CONNECTION EXISTING WATER MAIN POLYPIG STATION PER STD PLAN 300.7 (1) VERTICAL CROSS (MJxFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH TEMPORARY THRUST BLOCKING 8'+ a a d • O o 0 NEW DI WATER MAIN e TEMPORARY BLOCKING CONNECTION TO EXISTING MAIN (BY CITY APPROVED WET TAP CONTRACTOR) 3 x ID (1) TAPPING TEE (FL) PER STD PLAN 300.6 MIN (1) TAPPING GATE VALVE (FLxMJ) (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH CONCRETE THRUST BLOCKING PER STD PLAN 330.1 FINAL CONNECTION UPON COMPLETION OF POLYPIGGING, HYDROSTATIC TESTING, AND DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING AND TEMPORARY BLOW -OFF ASSEMBLIES FINAL CONNECTION (BY CITY FORCES) (2) DI SPOOLS (1) LONG BODY DI SLEEVE (MJ) Q a d • Q oOo NEW DI WATER MAIN a • PUBLIC WORKS :45 AP DEPARTMENT : 4 S AN 90' BEND CAP / PLUG B TEE NOTES: 1. ALL CONNECTIONS TO EXISTING WATER MAINS WILL BE CONDUCTED BY CITY FORCES AS SPECIFIED IN SECTION 5-14.2 OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS 2. LONG BODY DI SLEEVE FOR CONNECTION FROM DI TO DI PIPE AND FROM DI TO CI PIPE WITH SAME OUTSIDE DIAMETER STD. PLAN - 300.5 CONNECTION TO WATER MAIN APPROVED: TAPPING TEE AND VALVE 6/28/2023 �nln PasnKna DATE blc woks Aeminiso-aco. IN 2 Connection To Water Main 45' BEND C 22 Y2o BEND D 11 Y4o BEND E, MINIMUM BEARING AREA AGAINST UNDISTURBED SOIL (SF) PIPE SIZE PR O O O O O (PSI)RE 4„ 200 2/(1) 1/(NONE) 1/(NONE) NONE NONE 300 3/(2) 2/(2) 2/(1) i/M NONE 6" 200 4/(3) 3/(2) 3/(1) 1/(1) 1/(NONE) 300 6/(4) 4/(3) 3/(2) 2/(1) 1/(NONE) 81. 200 7/(5) 5/(3) 4/(3) 2/(2) 1/M 300 11/(8) 8/(5) 6/(4) 3/(2) 2/(1) 10.1 200 11/(8) 8/(6) 6/(4) 3/(2) 2/(1) 275 16/(11) I1/(7) 9/(6) 5/(3) 3/(2) 12" 200 16/(11) 11/(8) 9/(6) 5/(3) 3/(2) 250 24/(16) 17/(11) 13/(9) 7/(5) 4/(3) 14" 200 22/(13) 16/(11) 12/(8) 6/(4) 3/(2) 250 33/(22) 23/(16) 18/(12) 9/(6) 5/(3) 16" 200 29/(19) 21/(14) 16/(11) 8/(6) 5/(3) 225 32/(21) 23/(16) 17/(12) 9/(6) 5/(3) 18" 200 36/(24) 26/(17) 20/(13) 10/(7) 5/(4) 20" 200 45/(29) 32/(21) 24/(16) 13/(8) 7/(4) 24" 200 64/(43) 46/(30) 35/(23) 18/(12) 9/(6) * VALUES BASED ON SAFE BEARING LOAD OF 2,000/(3,000) PSF SOIL TYPE SAFE BEARING LOAD (PSF) MUCK OR PEAT 0 SOFT CLAY 1,000 SAND 2,000 SAND AND GRAVEL 3,000 CEMENTED WITH CLAY 4,000 HARD SHALE 10,000 NOTES: 1. MINIMUM BEARING AREA MUST BE ADJUSTED FOR PIPE SIZE, PRESSURE, AND SOIL CONDITIONS. 2. FITTINGS SHALL BE POLYWRAPPED PRIOR TO POURING CONCRETE BLOCKING. 3. CONCRETE BLOCKING SHALL BE CAST IN PLACE AND SHALL HAVE A MINIMUM OF 0.25 SF BEARING AREA AGAINST THE FITTING. 4. CONCRETE BLOCKING SHALL BEAR AGAINST FITTINGS ONLY AND SHALL BE CLEAR OF JOINTS TO PERMIT TAKING UP OR DISMANTLING JOINT. 5. CONTRACTOR SHALL INSTALL BLOCKING ADEQUATE TO WITHSTAND FULL HYDROSTATIC TEST PRESSURE AS WELL AS TO CONTINUOUSLY WITHSTAND OPERATING PRESSURE UNDER ALL CONDITIONS OF SERVICE. 6. ALL CONCRETE SHALL BE MECHANICALLY MIXED. JOB SITE MIXING, HAND -MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. 7. IN MUCK OR PEAT, ALL THRUSTS SHALL BE RESTRAINED BY PILES OR TIE RODS TO SOLID FOUNDATION OR MUCK OR PEAT SHALL BE REMOVED AND REPLACED WITH BALLAST OF SUFFICIENT STABILITY TO RESIST THRUST. 8. CONCRETE BLOCKING SHALL BE LEFT OPEN OR SHEETED FOR MINIMUM 24 HOURS. STD. PLAN - 330.1 •� PUBLIC WORKS CONCRETE BLOCKING APPROVED: DEPARTMENT FOR HORIZONTAL FITTINGS 6/28/2023 �a,tln PashNa bloc wo,ksaemin DATE NTS Y NTS F'' Erosion and Sediment Control Standard Plan Notes W -° JAC013SON CONSULTING ENGINEERS �. JAB Concrete Blocking for Horizontal Fittings NAAS77 SPR APPLICATION BUILDING PERMIT 1 COP-1 w� CIVIL PERMIT SUBMITTAL 43667 S-F `I S T'ug o CIVIL PERMIT RESUBMITTAL ��1� NAL NO. REVISION WATER PLAN GENERAL NOTES Standard Plan No. 300 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION. 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND "CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON -SITE. 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C 104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10-INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST METHOD (MOD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MOD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS (OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING. 8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE REMOVE ALL SURFACE MATERIALS AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION. ti�Y o STD. PLAN - 300.0 °,► PUBLIC WORKS WATER PLAN GENERAL NOTES DEPARTMENT "F'FN,TO MARCH 2O10 NTS _(:j) Water Plan General Notes U) 475 U 0 0 1-- 475 m Z co z 00 m PROPOSED FIRE 0 0 Z 0 w HYDRANT ASSEMBLY mQ = ¢ (BEYOND) LL U 0 N 470 o w 470 (0 00>��>\Lu EX GRADE 465 465 I CL52 C'7 25 LF 8" DI CL52 29 LF 8" DI CL52 460 460 8" POLYPIGGING STATION PER STD PLAN NO. 300.7 455 c) 0 0 455 J CO (n OJ w z W QLU U CO 0 Z �UOm �Z CO Co _J 00 2 U X Z H > �Lu _j 0> m p01Zp Z U� Z w�� O co Z- =Z C0 mQLL-¢ LL w \ Q�J 450w�>< ���M Q~ ZLu>- Q 450 Z w 0= 7- .� F- 0< _ w co U OO>�Z w w Or C) d 0= QJ(n -- - U��`�� =�C9�0 �a LLI 00 CO 00 LL- J rl c-I rl In 1. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF SAFETY YELLOW DTM ACRYLIC GLOSS OR ENAMEL PAINT. 2. PUMPER NOZZLE TO FACE ROADWAY OR AS DIRECTED BY RRFA. 3. A MINIMUM T RADIUS UNOBSTRUCTED WORKING AREA SHALL BE PROVIDED AROUND THE OUTSIDE OF THE HYDRANT. MATERIALS COMPRESSION TYPE HYDRANT (SEE APPROVED MATERIALS LIST) WITH 6" MJ INLET WITH LUGS, S Y4" MVO, OA HYDRANT 1 Y4' PENTAGON OPERATING NUT, TWO (2) 2 Y" NST HOSE NOZZLES, AND 4.875" SST PUMPER NOZZLE EQUIPPED WITH 5" STORZ ADAPTER AND 1/8" STAINLESS STEEL CABLE, WITH EXTENSION IF NECESSARY. OB TEE MAIN LINE TEE WITH 6" FLANGE SIDE OUTLET OC VALVE 6" GATE VALVE (FLxMJ) OD VALVE BOX VALVE BOX AND LID PER STD PLAN 330.7 OE PIPE CLASS 52 DI, LENGTH TO FIT OF JOINT RESTRAINT MECHANICALJOINT RESTRAINT WITH CONCRETE BLOCKING OR (2) 3/4" CORTEN STEELTIE RODS 1 Y4' WASHED DRAIN ROCK, MINIMUM 1' ABOVE BOOT FLANGE WITH 8-MIL POLYETHYLENE SHEETING GO GRAVEL AROUND TOP AND SIDES OF GRAVEL OH CONCRETE BLOCK MINIMUM 16"x8"x4" CONCRETE BLOCKS UNDER FIRE HYDRANT AND GATE VALVE OI BLOCKING CONCRETE BLOCKING PER STD PLAN 330.1 JO SHEAR BLOCK 4'x4'x6" CONCRETE SHEAR BLOCK AROUND FIRE HYDRANT, SEE STANDARD DETAIL 310.2 O PAVEMENT MARKER BLUE REFLECTIVE PAVEMENT MARKER PER STD PLAN 310.3 STD. PLAN - 310.1 PUBLIC WORKS APPROVED: FIRE HYDRANT ASSEMBLY DEPARTMENT 6/28/2023' vren Paa„rna DATE mm woes anmmmmo, FINAL JOIN MUST BE SAW -CUT (TYP) 1" BELOW EXIST 12" MIN 445 445 IRE HYDRANT ASSEMBL Scale: 1"=5' V. 1"=20' H I 6- 6 NTS Fire Hydrant Profile /22/23 SURVEYED: SCALE: VERTICAL: NAVD 1988 / „- HORIZONTAL: NAD 1983/1991 CITY OF 4/ 23 DESIGNED: 1 -10 + /22/23 SSE DRAWN: RENTON /12/23 DJD ONE INCH DATUM 0 1/30/2 CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH BY DATE APPR 'wPROVE JAJ SCALE ACCORDINGLY SEE STANDARD PIPE TRENCH DETAIL NTS Fire Hydrant Assembly ASPHALT CONCRETE HMA CLASS 1/2" (3" MIN) REPLACEMENT PATCH TO BE 1" THICKER THAN PREVIOUSLY EXISTED r COMPACTED CRUSHED I SURFACING TOP COURSE CRUSHED SURFACING BASE COURSE SEAL JOINT WITH COUNTY APPROVED SEALANT IEXISTING ASPHALT APPLY ASPHALT TACK COAT AT ALL JOINTS (TYP) NTS n Asphalt patch a W-428003 R-428008 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING SAMorman 01 /12/2024 EWATER UTILITY % ABDOUL GAFOUR 01/12/2024 DATE: HAZEN HIGH SCHOOL B o/30/23 FIEL PAGE: SITEWORK FOR PORTABLE CLASSROOMS DRAWING NO: SITE DETAILS C5 SHEET: CIR 8 OF 8 LJ W co C) O O N rr r1's t'J N J PERMIT/PRICING REVIEW SET