HomeMy WebLinkAbout20220525-22291-FR-SkyHorse-B21004426-SAT052522D-RSDAILY FIELD REPORT
AAR TESTING AND INSPECTION, INC.
7126 180th Ave NE, Suite C101
Redmond, WA 98052
425-881-5812
Inspection Date
05/25/2022
Report Number
SAT052522D
Inspectors Signature
Inspectors Name
Silvestre Tangalan
Jr. WABO #SI
01086
Report Date
05/25/2022
Reviewers Signature Reviewed By
Teajalam (TJ) Gounden
Reviewed Date
05/26/2022
0B21DF68-8424-42AF-BDC8-DFAA0808B8E1
CLIENT INFORMATION PROJECT INFORMATION
Contact Tony Project No.22-291
Company DR Horton Project Name Sky Horse
Address 11241 Slater Ave NE, Ste 200 Address 16327 SE 132nd Street
City Kirkland City Renton
Contractor Superior Concrete Permit No.B21004426
INSPECTION TYPE(S)STRUCTURE(S) / LOCATION(S)
Reinforcing Steel South Detention vault walls, Interior walls, wing walls, pass through reinforcement.
Weather
Clear
Temperature (°F)
60
Start Time
03:00 PM
End Time
05:00 PM
DRAWINGS / DOCUMENTS REFERENCED
S1, S3.
INSPECTION OBSERVATION / REMARKS
* Perimeter wall: vertical at #6 at 12”OC with 2” clearance from inside forms; horizontal #5 at 12”OC.
* Interior walls: #5 at 12”OCEW, centered rebar.
* Pass through: (2)#5 vertical jamb reinforcement, (2)#7 horizontals with 30” overhang, header reinforcement, header reinforcement: #4 “J”
bars at header at 6”OC.
* Wing walls: vertical & horizontals with (2)#5 verticals at each end of wall.
* “Floating corners”: #5 at 12”OCEW
* Perimeter wall intersecting with interior wall(4’-0” wide) with horizontal corner bars from inter wall to perimeter exterior ( #5 at 12”OC) with
alternating tails.
Items inspected are in conformance with approved plans, specifications and jurisdictional requirements
DAILY FIELD REPORT
AAR TESTING AND INSPECTION, INC.
7126 180th Ave NE, Suite C101
Redmond, WA 98052
425-881-5812
Inspection Date
05/25/2022
Report Number
SAT052522D
Inspectors Signature
Inspectors Name
Silvestre Tangalan
Jr. WABO #SI
01086
Report Date
05/25/2022
Reviewers Signature Reviewed By
Teajalam (TJ) Gounden
Reviewed Date
05/26/2022
0B21DF68-8424-42AF-BDC8-DFAA0808B8E1
PHOTOS
Building permit Perimeter wall vertical reinforcement with 2” clearance from
inside forms.
East perimeter wall reinforcement
DAILY FIELD REPORT
AAR TESTING AND INSPECTION, INC.
7126 180th Ave NE, Suite C101
Redmond, WA 98052
425-881-5812
Inspection Date
05/25/2022
Report Number
SAT052522D
Inspectors Signature
Inspectors Name
Silvestre Tangalan
Jr. WABO #SI
01086
Report Date
05/25/2022
Reviewers Signature Reviewed By
Teajalam (TJ) Gounden
Reviewed Date
05/26/2022
0B21DF68-8424-42AF-BDC8-DFAA0808B8E1
Horizontal exterior reinforcement
DAILY FIELD REPORT
AAR TESTING AND INSPECTION, INC.
7126 180th Ave NE, Suite C101
Redmond, WA 98052
425-881-5812
Inspection Date
05/25/2022
Report Number
SAT052522D
Inspectors Signature
Inspectors Name
Silvestre Tangalan
Jr. WABO #SI
01086
Report Date
05/25/2022
Reviewers Signature Reviewed By
Teajalam (TJ) Gounden
Reviewed Date
05/26/2022
0B21DF68-8424-42AF-BDC8-DFAA0808B8E1
Reinforcement at pass through.