Loading...
HomeMy WebLinkAbout20220608-22291-FR-SkyHorse-B21004426-SCG060822A-RSDAILY FIELD REPORT AAR TESTING AND INSPECTION, INC. 7126 180th Ave NE, Suite C101 Redmond, WA 98052 425-881-5812 Inspection Date 06/08/2022 Report Number SCG060822A Inspectors Signature Inspectors Name Shawn Glass Report Date 06/08/2022 Reviewers Signature Reviewed By Teajalam (TJ) Gounden Reviewed Date 06/09/2022 3C2E4BAA-81DC-4BA2-975B-0FC3665D5819 CLIENT INFORMATION PROJECT INFORMATION Contact Tony Project No.22-291 Company DR Horton Project Name Sky Horse Address 11241 Slater Ave NE, Ste 200 Address 16327 SE 132nd Street City Kirkland City Renton Contractor Superior Concrete Permit No.B21004426 INSPECTION TYPE(S)STRUCTURE(S) / LOCATION(S) Reinforcing Steel Lid closures for both South and North vaults Weather Cloudy Temperature (°F) 59 Start Time 07:26 AM End Time 08:05 AM DRAWINGS / DOCUMENTS REFERENCED Approved structural plans, details, RFIs, and shop drawing for reference. INSPECTION OBSERVATION / REMARKS On site for rebar inspection for lid closure of both the South and North vaults. Verified rebar to be in conformance with approved plans, detail on S5 and key notes for reinforcement. Rebar, size, grade, clearances, and lap splices all meet plan specs. Clear to pour on schedule date and time. Items inspected are in conformance with approved plans, specifications and jurisdictional requirements DAILY FIELD REPORT AAR TESTING AND INSPECTION, INC. 7126 180th Ave NE, Suite C101 Redmond, WA 98052 425-881-5812 Inspection Date 06/08/2022 Report Number SCG060822A Inspectors Signature Inspectors Name Shawn Glass Report Date 06/08/2022 Reviewers Signature Reviewed By Teajalam (TJ) Gounden Reviewed Date 06/09/2022 3C2E4BAA-81DC-4BA2-975B-0FC3665D5819 PHOTOS North vault single cell North vault single cell DAILY FIELD REPORT AAR TESTING AND INSPECTION, INC. 7126 180th Ave NE, Suite C101 Redmond, WA 98052 425-881-5812 Inspection Date 06/08/2022 Report Number SCG060822A Inspectors Signature Inspectors Name Shawn Glass Report Date 06/08/2022 Reviewers Signature Reviewed By Teajalam (TJ) Gounden Reviewed Date 06/09/2022 3C2E4BAA-81DC-4BA2-975B-0FC3665D5819 North vault single cell South vault two cells DAILY FIELD REPORT AAR TESTING AND INSPECTION, INC. 7126 180th Ave NE, Suite C101 Redmond, WA 98052 425-881-5812 Inspection Date 06/08/2022 Report Number SCG060822A Inspectors Signature Inspectors Name Shawn Glass Report Date 06/08/2022 Reviewers Signature Reviewed By Teajalam (TJ) Gounden Reviewed Date 06/09/2022 3C2E4BAA-81DC-4BA2-975B-0FC3665D5819 South vault two cells South vault two cells