HomeMy WebLinkAboutMFP24005721.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP24005721
IVR Number: 24005721
Permit Information
Permit Name: FIELD VERIFY IF EXISTING GAS LINEN.92E CAUTION AND PROTECT EXISTING
SANITARY SEWER PIPES AND STRUCTURES IN PLACE. REMOVE EXISTING
CATCH BASIN.
Address/Location:11/12/2024Application Date:9423500000Parcel Number: 607 WILLIAMS AVE S
Permit Type:11/25/2024Issue Date:Franchise
Permit Work Class:11/25/2025Expiration Date:Minor Utility
Job Number: N.928658Franchise Type:Telephone
Description: VERIFY IF EXISTING GAS LINE IS ACTIVE OR ABANDONED AT LEAST 1 WEEK IN ADVANCE OF TRENCHING IN
THIS LOCATION. IF ACTIVE, PROTECT IN PLACE. IF ACTIVE AND IN CONFLICT WITH PROPOSED STORM DRAIN,
COORDINATE WITH PSE TO RELOCATE. IF ABANDONED, COORDINATE WITH PSE FOR
REMOVAL/ABANDONMENT PROCEDURE. PLUG AND CAP EXISTING STORM DRAIN.
EXISTING WATER MAIN, PROTECT IN PLACE. CONNECT TO EXISTING STORM DRAIN LATERAL. FIELD VERIFY IF
THE EXISTING STORM DRAIN LATERAL CONNECTION IS ACTIVE OR ABANDONED AT LEAST 1 WEEK IN
ADVANCE OF TRENCHING IN THIS LOCATION. IF ACTIVE, MAKE CONNECTION FROM EXISTING PIPE TO NEW
PIPE WITH NYOPLAST FITTING (OR SIMILAR). IF ABANDONED, PLUG AND CAP. PLUG AND CAP EXISTING
SANITARY SEWER. RECONNECT EXISTING SIDE SEWER LATERAL TO NEW SANITARY SEWER AS INDICATED
ON THE PLANS AND PER COR STANDARD PLAN 407. EXISTING SANITARY SEWER SHALL BE REMOVED WHERE
INDICATED TO INSTALL PROPOSED STORM DRAIN. EXISTING SANITARY SEWER IS DEFLECTED HDPE,
CONTRACTOR TO USE CAUTION AND PROTECT EXISTING SANITARY SEWER PIPES AND STRUCTURES IN
PLACE. REMOVE EXISTING CATCH BASIN.
Contacts
Name Address PhoneTypeBilling
Craig McPherson
K&B Technical Solutions
6566 SE Lake Rd Suite F
Milwaukie, OR 97222
B: (971) 282-2149Applicant
Nathan Macleod
Lumen
7850 S Trafton St, Bldg B
Tacoma, WA 98409
C: (253) 583-6283ApplicantX
Angelina Maxwell
CentryLink/Lumen
4201 SW GRAHAM ST 1, 1
Seattle, WA 98136
B: (206) 945-0048Applicant
Prime Electric Inc 3460 161ST Ave SE
Bellevue, WA 98008
B: (425) 747-5200Applicant
Ron Desmet
Fibe Solutions
604 W Meeker St., Suite 103
KENT, WA 98032
C: (206) 571-2230Applicant
Cheyenne Classen
North Sky Communications
2112 97th Ave E
Tacoma, WA 98444
Contact
Kim Parker
QWest Corporation
931 14th St, Suite 1000A
Denver, CO 80202
B: (303) 992-0752Contact
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Austin Sweeney
Century Link
23315 66th Ave S
Kent, WA 98032
C: (253) 766-7549Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
Page 1 of 2THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP24005721
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 2 of 2THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 3/18/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 3/18/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐ Electronic Copy of the TCP Application
☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
▪ Include map(s) showing the location of the project and work area.
▪ Be legible lettering and clear, contrasting, symbols of viewing or printing.
▪ Must indicate street names, and north arrow and scale.
▪ Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 3/18/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
• Must have approved Traffic Control Plan (TCP) prior to commencing the work.
• Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
• WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
• Comply with all traffic regulations of the City of Renton and the State of Washington.
• Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
• Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
• Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
• Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
• The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
• All permit conditions shall be met.
NOTES:
• Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
• Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
• Approved Temporary Traffic Control Plan must be at the work site during work hours.
• Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure.
• Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
• Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
• Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
• In the case of Temporary No Parking Zones, all the following apply in addition to previous:
• Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
• Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 3/18/2021
• The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
• Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
11/12/2024
Nathan Macleod
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
19 19
ALLEYALLEY SIDEWALKSIDEWALKSIDEWALKSIDEWALKGRASSGRASSWILLIAMS AVE SWILLIAMS AVE SNOPARKING
FROM
TO
TOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555
MH
ROAD
WORK
AHEADW20-1
ONE LANEROADAHEADW20-4
W20-7
X
X
X
ROADWORKAHEAD W20-1
ONE LANEROADAHEAD W20-4
W20-7
X
X
X
ROADWORKAHEAD W20-1
X
STOP
FLAGGER
STOP
FLAGGER
90'x10'
MH 11-1
NOPARKING
FROM
TO
TOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555
SHEET 1 OF 1
MANHOLE ACCESS & ADJUSTMENT
Legend
Cone
STOP Flagger
MH Manhole
Spotter
Truck & Trailer
Truck With Lights
Work Area
TRAFFIC CONTROL PLAN
N
ON-SITE CONTRACTOR RESPONSIBLE TO
ENSURE ALL SIGNS & TRAFFIC CONTROL
DEVICES' PLACING AND SPACING ARE IN
ACCORDANCE TO: WSDOT, MUTCD, &
CITY REQUIREMENTS.
Plan Scale
1 : 360 (1'' = 30')
Date:10/24/24 Author:ZACH MILLER Project:N.928658
Comments:
ACCESS PEDESTAL IN RENTON, WA
SHOULDER(CURB PARKING) CLOSURE
SIDEWALL SHALL REMAIN OPEN
DRIVEWAY SPOTTERS TO ENSURE SAFETY
SPEED
LIMIT
25
LOCATION:
99 Williams Ave S, Renton, WA 98057
NOTE:
NO-PARKS SHALL BE SET 72 HOURS IN ADVANCE.
www.invarion.com
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
BUSINESS
ACCESS
PARKINGLOTPARKINGLOTSIDEWALK
S TOBIN ST
ALLEYBURNETT AVE SWILLIAMS AVE S34
2020
SIDEWALK SIDEWALKCURB PARKINGCURB PARKINGCURB PARKING
CURB PARKING CURB PARKING
ROADWORK
AHEADW20-1
XPD
ROADWORKAHEADW20-1
XROADWORKAHEAD W20-1
X
X
X
SHOULDERWORK W21-5
SHOULDERCLOSED W20-301
SHEET 1 OF 1
PEDESTAL ACCESS/REMOVAL
Legend
Cone
PD Pedestal
Spotter
Truck With Lights
Work Area
TRAFFIC CONTROL PLAN
N
ON-SITE CONTRACTOR RESPONSIBLE TO
ENSURE ALL SIGNS & TRAFFIC CONTROL
DEVICES' PLACING AND SPACING ARE IN
ACCORDANCE TO: WSDOT, MUTCD, &
CITY REQUIREMENTS.
Plan Scale
1 : 360 (1'' = 30')
Date:10/24/24 Author:ZACH MILLER Project:N.928658
Comments:
ACCESS PEDESTAL IN RENTON, WA
SHOULDER(CURB PARKING) CLOSURE
SIDEWALL SHALL REMAIN OPEN
SPOTTERS TO ENSURE SAFETY
SPEED
LIMIT
25
PEDESTAL 25'x9'
LOCATION:
704 S Tobin St, Renton, WA 98057
www.invarion.com
PARKING
LOT
DRIVEWAY
DRIVEWAYDRIVEWAY
DRIVEWAY
BUSINESS
ACCESS
PARKINGLOTPARKINGLOTAPARTMENT
PARKING LOT
SIDEWALK
SIDEWALK
S TOBIN ST
S TILLICUM ST
ALLEYBURNETT AVE SWILLIAMS AVE S34
2020
18SIDEWALK
SIDEWALK SIDEWALKCURB PARKINGCURB PARKINGCURB PARKING
PD
ROADWORKAHEAD
W20-1
XXXSHOULDERWORK
W21-5
SHOULDERCLOSED
W20-301
ROADWORKAHEADW20-1
XROADWORKAHEAD W20-1
X
X
X
SHOULDERWORK W21-5
SHOULDERCLOSED W20-301
SHEET 1 OF 1
PEDESTAL ACCESS
Legend
Cone
PD Pedestal
Spotter
Truck With Lights
Work Area
TRAFFIC CONTROL PLAN
N
ON-SITE CONTRACTOR RESPONSIBLE TO
ENSURE ALL SIGNS & TRAFFIC CONTROL
DEVICES' PLACING AND SPACING ARE IN
ACCORDANCE TO: WSDOT, MUTCD, &
CITY REQUIREMENTS.
Plan Scale
1 : 360 (1'' = 30')
Date:10/24/24 Author:ZACH MILLER Project:N.928658
Comments:
ACCESS PEDESTAL IN RENTON, WA
SHOULDER(CURB PARKING) CLOSURE
SIDEWALL SHALL REMAIN OPEN
SPOTTERS TO ENSURE SAFETY
SPEED
LIMIT25
PEDESTAL
25'x9'
LOCATION:
704 S Tobin St, Renton, WA 98057
www.invarion.com
12345-10
FOR REFERENCE ONLY
Plans Prepared For:
Plans Prepared By:
LOCATION MAPNOT TO SCALE N
REV. DATE DESCRIPTION
1 01-30-24 Initial CBM -100% Updated - LSB
Project Manager
Index of Sheets:
PROJECT LOCATION
NOTES: ALL EXISTING AND PROPOSED CONDITIONS ARE BASED ON INFORMATION PROVIDED BY OTHERS. LUMENCANNOT BE RESPONSIBLE FOR THE ACCURACY OF INFORMATION AND/OR PLANS PROVIDED BY OUTSIDE PARTIES. FACILITY LOCATIONS, DEPTHS AND ELEVATIONS SHOULD BE FIELD VERIFIED PRIOR TO CONSTRUCTION. PROPOSEDDESIGN MODIFICATIONS ARE RECOMMENDATIONS ONLY AND SHOULD BE VERIFIED PRIOR TO CONSTRUCTION.
CITY OF RENTON - PROJECT No. SWP-27-4-88RENTON, WABURNETT AVE S & WILLIAMS AVE S: STORM SYSTEM IMPROVEMENTS
TT Eng: Cory CoatePhone: 503-961-5023E-mail: ccoate@congruex.comhttp://www.terratechllc.net
LOCAL ADDRESS:710 S 2nd St,Renton, WA 98057
Lumen Wire Center: RNTNWA01 [RENTON]Lumen Engineer: Kaeleb Conkle Hernandez Phone: 253-458-6549 Email: Kaeleb.ConkleHernandez@lumen.comLumen CPA: Darren Pianhly Phone: 253-458-6552 Email: Darren.Pianhly@lumen.com
Project Engineer: Troy Solly - City of RentonPhone: 425-430-7313Email: TSolly@rentonwa.gov
Road Contractor: RL AliaPhone:Email:
Owner: City of RentonPhone:Email:
Estimated Agency Design Milestone: 100% Submittal
Agency File Name: Burnett & Williams 100% Drawings.pdf
Date Received File from Agency: 01/25/2024
Cover SheetLegendTitle SheetKey Plan MapStorm Plan & Profile
Permitting:
Permits Required: Y___ N___City: RENTONCounty:State:Railroad:DNR:Other:
Cuts Required: Y___ N______ Fiber___ Copper
Migrations Required: Y___ N___
Agency Planned Construction Start Date:10/7/2024
REVISION HISTORY:
SHEET 1 of 10
LUMEN PROJECT No. N.928658TT PROJECT NO. TERR-1007517
LUMEN CIVIL BASE MAP (TYPE OF PLAN: CR)
Agency Contact Information:
Field Engineer
TT Eng: Jesse PatjensPhone: 425-429-5722 E-mail: jpatjens@congruex.comhttp://www.terratechllc.net
Ce
d
a
r
R
i
v
e
r
Burnett Pl SWilliams Ave SS 2nd St
S Tillicum St
S Tobin St
Burnett Ave S2 02-07-24 Mitigation Review - JP
3 09-05-24 Permit Set Issued - JP
Symbols
HH
HH
CP
Existing Lumen pedestalor
or
or
New Lumen pedestal
Existing Lumen pedestal to be removed
Existing Lumen SAI (serving area interface)
New Lumen SAI (serving area interface)
Existing Lumen SAI to be removed orabandoned
Existing Lumen cable or conduit to beremoved or abandoned
Existing Lumen handhole
New Lumen handhole
Existing Lumen handhole to be removed
Existing Lumen manhole (various sizes)
New Lumen manhole (various sizes)
Existing Lumen double lidded manhole(various sizes)
New Lumen double lidded manhole (varioussizes)
Existing Lumen manhole to be removed orabandoned (all sizes and types)
Existing Lumen repeater
New Lumen repeater
Existing Lumen repeater to be removed
CP
Existing Lumen cool ped. - fiber/electronics
New Lumen cool ped. - fiber/electronics
Existing Lumen RT (remote terminal)
New Lumen RT (remote terminal)
Existing Lumen pole
New Lumen pole
Existing Lumen down guy and anchor
New Lumen down guy and anchor
New Lumen sidewalk down guy and anchor
btel Existing buried telephone line
tduc Existing telephone duct run
afo-exist Existing aerial fiber optic
aer-tel Existing overhead telephone line
fo-exist Existing buried fiber optic
bsw-ex Existing buried service wire
asw-ex Existing aerial service wire
New overhead telephone line
BTEL New buried telephone line
TDUC New telephone duct run
BSW-NEW New buried service wire
AFO-NEW New aerial fiber optic
AER-TEL
FO-NEW New buried fiber optic
ASW-NEW New aerial service wire
Existing buried splice
New buried splice
Abbreviations
ct. = Countpr. = Pairpp = Pending Placementug. = Undergroundex. = Existing
Existing joint use pole
New joint use pole
New foreign owned (e.g. power)
Existing foreign owned (e.g. power)
J
J
Existing Lumen power pedestal
New Lumen power pedestal
P
P
Existing Lumen pole to be removed
btel btel btel btel btel
tduc tduc tduc tduc tduc tduc tduc
X X X X X X
X X X X X X
Cable to be removed orabandoned as shown.
X X
Line Types
LEGEND
Lower Lower
BORE BORE
Lower cable or conduit
New underground bore
Raise Raise Raise cable or conduit
Temporary ground layTEMPTEMP
HH
TRENCH TRENCH
PLOW PLOW
Abandon in place
To be removed
New placement by plow
New placement by trenching
Lumen Civil Base Map Sheet2of 10
Terra Tech Project No. 1007517
File: CBM - TT#1007517 - Burnett & Williams 100%Drawings - LSB 01-30-2024.pdf LEGEND
Lumen Project No. N.928658 Date:Plans Prepared For:Plans Prepared By:
Existing FacilitiesConflict Mitigation Action (Proposed Facilities)Removals and abandonmentAdditional Information/Notes
Civil Base Map Color Key:
STORM SYSTEM IMPROVEMENTS
SWP-27-4088
DECEMBER 2023
FUNDED IN PART BY WASHINGTON STATE DEPARTMENT OF ECOLOGY
COPYRIGHT © 2023 BHC CONSULTANTS, LLC. ALL RIGHTS RESERVEDPath: S:\Cad\Renton\20-10723 Burnett-Williams\Design\d Filename: P20-10723_G-1 Plot date: Dec 21, 2023-01:10:00pm CAD User: acariaso. Xref Filename: | X20-10723_Prelim |G-1
Xof1
BHC Consultants, LLC
1601 Fifth Avenue, Suite 500
Seattle, Washington 98101
206.505.3400
206.505.3406 (fax)
www.bhcconsultants.com
KING COUNTY
BHC Consultants, LLC
1601 Fifth Avenue, Suite 500
Seattle, Washington 98101
206.505.3400
206.505.3406 (fax)
www.bhcconsultants.com
DUANE HARTMAN & ASSOCIATES INC. - SURVEY
KLEINFELDER - GEOTECHNICAL
TENW - TRAFFIC AND SURFACE RESTORATION
THE WATERSHED COMPANY - CRITICAL AREAS
ASM AFFILIATES (FORMERLY CASCADIA ARCHEOLOGY) - CULTURAL RESOURCES
KING COUNTY
PROJECT LOCATION
405
5
Seattle
Redmond
2
522
90
202
18
169
167
Skykomish
Maple Valley
Bellevue
Renton
PREPARED BY:
IN ASSOCIATION WITH:
LOCATION MAP VICINITY MAP
520
NTS NTS
ARMONDO PAVONE - MAYOR
SURFACE WATER UTILITY MANAGER
JOSEPH FARAH, P.E.
RENTON CITY COUNCIL
CARMEN RIVERA
ED PRINCE
JAMES ALBERSON JR.
KIM-KHANH VAN
RUTH PEREZ
RYAN MCIRVIN
VALERIE O'HALLORAN
PROJECT MANAGER
TROY SOLLY, P.E.
Shoreline
BURNETT AVE S AND WILLIAMS AVE S
PROJECT
LOCATION
BURNETT AVE SWILLIAMS AVE SS 2ND ST
B R O N S O N W A Y N
LOGAN AVE SWELLS AVE SN 1
S
T S
T
MAIN AVE SKEY CONTACT INFORMATION
AGENCY DEPARTMENT CONTACT PHONE EMAIL
COR WATER ABDOUL GAFOUR 425.430.7210 agafour@Rentonwa.gov
COR WASTEWATER JOE STOWELL 425.430.7212 jstowell@Rentonwa.gov
COR SURFACE WATER TROY SOLLY 425.757.4012 tsolly@Rentonwa.gov
COR TRANSPORTATION BOB HANSEN 425.430.7223 bhansen@Rentonwa.gov
KING COUNTY WASTEWATER MARK LAMPARD 206.477.5414 lpa.team@kingcounty.gov
PSE GAS & POWER DUSTIN WELLER 206.379.4347 dustin.weller@pse.com SHEET3 of 10
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: S:\Cad\Renton\20-10723 Burnett-Williams\Design\dwgs\P20-10723_C-1.dwgCITY OF
RENTON
Planning/Building/Public Works Dept.
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:
BHC Consultants, LLC
1601 Fifth Avenue, Suite 500
Seattle, Washington 98101
206.505.3400
206.505.3406 (fax)
www.bhcconsultants.com
45243STATE OF WASHING
T
ONR
EGIST E R E DP
R
OFESSIONAL ENG INE E R REBL DAYO
C
HI
LTREEECCA OVE BURNETT AVE S AND WILLIAMS AVE S
STORM SYSTEM IMPROVEMENTS
DECEMBER 2023
1-800-424-5555 or 811
UNDERGROUND SERVICE
Call 48 Hours
Before You Dig
SWP-27-4-88
KEY PLAN AND
SURVEY CONTROL AND TESC PLAN C-1
X X
R. OCHILTREE, P.E.
P. SIMON
N/A
NOTES:
THIS EXISTING BASE MAP WAS PREPARED FROM A
SURVEY DRAWING PREPARED BY DUANE HARTMAN
AND ASSOCIATES, SURVEYED ON DECEMBER 2020,
WITH MODIFICATIONS BASED ON FIELD
OBSERVATIONS BY BHC STAFF.
SURVEY NOTES SURVEY CONTROL
PT # SURVEY PT # DESCRIPTION NORTHING EASTING ELEVATION
20 DHA 3054-20 MCW 179243.2287 1300878.516 38.6318
22 DHA 3054-22 MCW 179796.62 1300882.882 26.77
26 154 MIC 178564.8209 1300849.14 39.503
102 MIC DHA 3054-14 179605.9895 1300876.361 37.3546
1758 150 WSDOT BRYN 1993 178757.1186 1300526.595 38.2585
2318 154 179094.7729 1300863.16 38.7155
2586 112 WSR 179585.3417 1300845.829 37.671
11
12
13
14
15
16
17
SURVEY CONTROL
PT # SURVEY PT # DESCRIPTION NORTHING EASTING ELEVATION
1 DHA 3054-10 MCW 179586.3823 1300852.023 37.4182
2 MIC DHA 3054-2 179476.2836 1300872.86 37.1526
4 DHA 3054-4 MCW 178854.7729 1300869.185 39.4519
5 DHA 3054-5 MCW 178722.5764 1300540.068 38.1106
6 DHA 3054-6 MCW 179075.0257 1300549.999 37.2039
7 DHA 3054-7 MCW 179481.1607 1300574.554 36.8218
8 DHA 3054-8 MCW 179604.6904 1300564.318 35.6507
9 DHA 3054-9 MCW 179467.7145 1300712.463 37.0527
12 154 MIC 180053.754 1301047.93 36.085
13 154 MIC 179801.312 1300951.201 36.82
1
2
3
4
5
6
7
8
9
10
UTILITIES MAPPING:
ALL EXISTING UTILITIES SHOWN HEREIN ARE TO BE VERIFIED HORIZONTALLY AND VERTICALLY
PRIOR TO ANY CONSTRUCTION. ALL EXISTING FEATURES INCLUDING BURIED UTILITIES ARE
SHOWN AS INDICATED BY RECORD LOCATION OR FIELD TIED AS A RESULT OF A UTILITY
PAINT-OUT DURING THE COURSE OF THE FIELD SURVEY. DUANE HARTMAN & ASSOCIATES, INC.
(DHA) AND BHC CONSULTANTS, LLC ASSUME NO LIABILITY FOR THE ACCURACY OF THE RECORD
INFORMATION. FOR THE FINAL LOCATION OF THE EXISTING UTILITIES IN AREAS CRITICAL TO
CONSTRUCTION, CONTACT THE UTILITY OWNER/AGENCY AND UTILITIES UNDERGROUND CENTER
(800/424-5555)
TOPOGRAPHIC MAPPING:
THE MAP SHOWN HEREON IS THE RESULT OF A TOPOGRAPHIC SURVEY BY DUANE HARTMAN &
ASSOCIATES, INC. (DHA) COMPLETED IN DECEMBER 2020. DHA AND BHC CONSULTANTS, LLC
ASSUME NO LIABILITY, BEYOND SAID DATE, FOR ANY FUTURE SURFACE FEATURE MODIFICATIONS
OR CONSTRUCTION ACTIVITIES THAT MAY OCCUR WITHIN OR ADJOINING THE PERIMETER OF THIS
SURVEY. CONTACT DHA (425) 483-5355 FOR SITE UPDATES AND VERIFICATIONS.
NOTE:
PROPERTY LINES SHOWN HEREON GENERATED FROM KING COUNTY RECORDS, AND ARE
CONSIDERED APPROXIMATE IN LOCATION.
HORIZONTAL DATUM:
WASHINGTON STATE COORDINATE SYSTEM, NORTH ZONE NAD83(1991), US FEET UTILIZING RTK
GPS FIELD PROCEDURES.
CONTOUR INTERVAL: HALF (0.5) FOOT CONTOURS
VERTICAL DATUM:
NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88), US FEET.
CATCH BASIN INSERT PER COR STD. PLAN 216.30
TREE PROTECTION FENCING
TESC NOTES
1. INSTALL TESC FACILITIES PRIOR TO EXCAVATION AS
INDICATED ON THE PLANS AND SPECIFICATIONS.
2. USE STRAW WATTLES AS NECESSARY TO CONTROL
SEDIMENT PER COR STD. PLAN 213.40.
TESC LEGEND
798187919599101107 75 720 55
51
82104
104
115
710
710
104
107
103
95
858 124 116 110 98 94 84 82 78 74 66
720
13
16
2
14
10
15
6
7
4
5
8
17
12
11
3
1
C-2 C-3
C-4 C-5 C-6C-7BURNETT AVE S
WILLIAMS AVE S S TOBIN STS 2ND ST104
= POTENTIAL CONFLICTS
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: S:\Cad\Renton\20-10723 Burnett-Williams\Design\dwgs\P20-10723_C-2-3 Burnett.dwgCITY OF
RENTON
Planning/Building/Public Works Dept.
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:
BHC Consultants, LLC
1601 Fifth Avenue, Suite 500
Seattle, Washington 98101
206.505.3400
206.505.3406 (fax)
www.bhcconsultants.com
45243STATE OF WASHING
T
ONR
EGIST E R E DP
R
OFESSIONAL ENG INE E R REBL DAYO
C
HI
LTREEECCA OVE BURNETT AVE S AND WILLIAMS AVE S
STORM SYSTEM IMPROVEMENTS
DECEMBER 2023
1-800-424-5555 or 811
UNDERGROUND SERVICE
Call 48 Hours
Before You Dig
SWP-27-4-88
BURNETT AVE S
PLAN AND PROFILE STA 1+00 TO 5+75 C-2
X X
R. OCHILTREE, P.E.
P. SIMON
CONSTRUCTION NOTES:
FIELD VERIFY IF EXISTING GAS LINE IS ACTIVE
OR ABANDONED AT LEAST 1 WEEK IN ADVANCE
OF TRENCHING IN THIS LOCATION. IF ACTIVE,
PROTECT IN PLACE. IF ACTIVE AND IN CONFLICT
WITH PROPOSED STORM DRAIN, COORDINATE
WITH PSE TO RELOCATE. IF ABANDONED,
COORDINATE WITH PSE FOR
REMOVAL/ABANDONMENT PROCEDURE.
PLUG AND CAP EXISTING STORM DRAIN.
EXISTING WATER MAIN, PROTECT IN PLACE.
CONNECT TO EXISTING STORM DRAIN LATERAL.
FIELD VERIFY IF THE EXISTING STORM DRAIN
LATERAL CONNECTION IS ACTIVE OR
ABANDONED AT LEAST 1 WEEK IN ADVANCE OF
TRENCHING IN THIS LOCATION. IF ACTIVE, MAKE
CONNECTION FROM EXISTING PIPE TO NEW
PIPE WITH NYOPLAST FITTING (OR SIMILAR). IF
ABANDONED, PLUG AND CAP.
PLUG AND CAP EXISTING SANITARY SEWER.
RECONNECT EXISTING SIDE SEWER LATERAL
TO NEW SANITARY SEWER AS INDICATED ON
THE PLANS AND PER COR STANDARD PLAN 407.
EXISTING SANITARY SEWER SHALL BE
REMOVED WHERE INDICATED TO INSTALL
PROPOSED STORM DRAIN.
EXISTING SANITARY SEWER IS DEFLECTED
HDPE, CONTRACTOR TO USE CAUTION AND
PROTECT EXISTING SANITARY SEWER PIPES
AND STRUCTURES IN PLACE.
REMOVE EXISTING CATCH BASIN.
1
NOTES:
1. ALL EXISTING TYPE 1 CATCH BASINS AND
LATERALS SHALL BE REMOVED AND REPLACED
AS SHOWN.
2. KC WTD/METRO 108-INCH SEWER RANGES IN
DEPTH FROM 20 TO 25-FEET ALONG BURNETT
AVE S.
3. PROTECT ALL EXISTING UTILITIES IN PLACE
UNLESS DENOTED AS ABANDONED OR TO BE
REMOVED.
4. INSTALL ETHAFOAM PAD BETWEEN PIPES IF
CLEARANCE IS 6" OR LESS.
5. MAKE CONNECTIONS FROM NEW PIPES TO
EXISTING PIPES VIA COUPLING BANDS (FERNCO
OR SIMILAR).
6. CATCH BASIN TYPE 1 PER COR STD PLAN 200.00.
7. CATCH BASIN TYPE 2 PER COR STD PLAN 201.00.
8. CATCH BASIN INSTALLATION PER COR STD PLAN
202.00.
9. LIMIT DISTURBANCE TO EXISTING SIDEWALK
AND PLANTER STRIP TO THE EXTENT
NECESSARY FOR PIPE AND CATCH BASIN
INSTALLATION. ANY SIDEWALK DAMAGED BY
OPERATION OF CONSTRUCTION EQUIPMENT ON
SIDEWALK SHALL BE REPLACED IN KIND BY THE
CONTRACTOR AT NO ADDITIONAL EXPENSE TO
THE CITY.
10. PIPES DENOTED AS PVC SHALL BE C900 PVC.
11. CONTRACTOR IS RESPONSIBLE FOR
PRESERVING, PROTECTING, AND TEMPORARY
BYPASSING PROVISIONS AS NECESSARY TO
MAINTAIN UTILITIES AND SERVICE.
HORIZ. 1" = 20'-0"
VERT. 1" = 5'-0"MATCHLINE STA - SEE DWG 5+75C-2MATCHLINE STA - SEE DWG 5+75 C-2
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: S:\Cad\Renton\20-10723 Burnett-Williams\Design\dwgs\P20-10723_C-2-3 Burnett.dwgCITY OF
RENTON
Planning/Building/Public Works Dept.
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:
BHC Consultants, LLC
1601 Fifth Avenue, Suite 500
Seattle, Washington 98101
206.505.3400
206.505.3406 (fax)
www.bhcconsultants.com
45243STATE OF WASHING
T
ONR
EGIST E R E DP
R
OFESSIONAL ENG INE E R REBL DAYO
C
HI
LTREEECCA OVE BURNETT AVE S AND WILLIAMS AVE S
STORM SYSTEM IMPROVEMENTS
DECEMBER 2023
1-800-424-5555 or 811
UNDERGROUND SERVICE
Call 48 Hours
Before You Dig
SWP-27-4-88
2
3
4
7
8
9
10
11
17SDMH #B1RIM EL 38.46EX IE 35.3± - 6" IN (S)IE 34.5 - 18" OUT (N)SDMH #B3RIM EL 38.14IE 33.4 - 18" IN (S)IE 33.4 - 18" OUT (N)IE 36.9 - 6" IN (E)SDMH #B4RIM EL 37.93IE 32.8 - 18" IN (S)IE 32.8 - 18" OUT (N)IE 34.2 - 6" IN (W)IE 34.9 - 12" IN (E)SEE LATERAL PROFILE A/C-10SDMH #B5RIM EL 37.86IE 32.5 - 18" IN (S)IE 32.5 - 18" OUT (N)IE 32.9 - 8" IN (W)IE 32.8 - 6" IN (E) TO BECAPPED AND PLUGGEDSEE LATERAL PROFILE B/C-1097 LF - 18" PP SD
S=0.3%
118 LF - 18" PP SD, S=0.5%150 LF - 18" PP SD, S=0.5%EX 8" S,TO BE ABANDONEDEX LT/F, EL UKNEX 2" G, IE 34.9TO BE RELOCATEDBY OTHERS PRIORTO CONSTRUCTIONEX 3/4" W, EL UKNEX S, TO BE ABANDONEDEX G, EL UKNEX S, TO BE ABANDONEDEX G, EL UKNEX 3/4" W, EL UKNEX G, EL UKNEX 3/4" W, EL UKNEX 5/8" G, IE 33.9TO BE RELOCATEDBY OTHERS PRIORTO CONSTURCTION50
40
35
30
25
20
15
1+00 2+00 3+00 4+00 5+00
EX GRADE AT
C/L OF PIPE
ALIGNMENTSSMH #1RIM EL 38.0±IE 32.33 - 8" OUT (N)35
30
25
40
45
50
20
15 SIDE SEWERSIDE SEWERSDMH #B2RIM EL 38.51IE 33.7 - 6" IN (W)IE 34.3 - 6" IN (E)IE 33.7 - 18" IN (S)IE 33.7 - 18" OUT (N)40 LF - 18" PP SD
S=2.0%111425 LF - 8" PVC SS
S=0.5%
52 LF - 18" PP SD, S=0.5%EX 5/8" G, IE 34.8TO BE RELOCATEDBY OTHERS PRIORTO CONSTRUCTIONEX 6" S, TO BE ABANDONED104
115
710
107
103
BURNETT AVE S
SDMH #B2
TYPE 2 - 48"
STA 1+82.62
CB #13
TYPE 1 W/ GRATE
STA 3+98.39
OFFSET 19.39' RT
SDMH #B3
TYPE 2 - 48"
STA 2+80.07
SDMH #B4
TYPE 2 - 48"
STA 3+98.39
SDMH #B5
TYPE 2 - 48"
STA 4+50.53
18" SD
PP
18" SD
PP
18" SD
PP
18" SD
PP
12" SD
DI
12" SD
PP
PH #6 PH #5
1+00 2+00 3+00 4+00 5+00100+00100+60101+00101+60SSMH #1
TYPE 1 - 48"
STA 2+78.78 LT 7.5'
SDMH #B1
TYPE 2 - 48"
STA 1+42.62
18" SD
PP
PH #W1
1 1 1
8" SS
PVC
3
10
2
3
10
6" SD
PVC
6" SD
PVC
11 3
6" SD
PVC
8" SD
PVC
6" SS
PVC
6" SS
PVC
4
8
4
4
7
4
7
7
7
17
9 99
2
99S 2ND STCB #12
TYPE 1 W/GRATE
STA 3+98.39
OFFSET 18.2' LT
tductductductductductductductductductductductductductducCON-C-4IN-WHIT17 Ducts w/
4 Copper Cables - 2100 PR to 3000 PR6 Fiber Cables - 72 to 576
CON-C-4IN-WHIT8 Ducts w/5 Copper Cables - 900 PR to 2700 PR
HHtductductductduc3 Underground Cables2 Copper Cables - 100 PR & 400 PR1 Fiber Cable - 72
tduc tduc
Handhole # 11-2
Manhole # 193
Underground
400pr ug. copper
100pr ug. copper
48ct ug. fiber
aer-tel aer-tel aer-tel aer-tel aer-tel aer-tel aer-tel aer-tel aer-tel aer-tel aer-tel aer-tel aer-tel aer-tel aer-tel aer-tel
2 Aerial Attach. on Joint Utility Poles2 Copper Cables - (2) 200 PR
1 Fiber Cable - 48
CON-C-4IN-WHIT1 Duct w/
1 Copper Cable - 200 PR
PP. 317868-166035
P. 0098
A1365195
45'-4: 1-PMT, 2" Riser,
2" U-guard, 2-DG&1-A
PP. 317883-166035P. 0098
A1365194
45'-4
PP. 317897-166036
P. 0098
A1365193
45'-4: 1-PMT, 1-X-Arm asw-ex asw-ex 4-wkg
2-Drops
PP. 317912-166036
P. 0100
A1365192
45'-4: 1-PMT, 4"-Riser
TO C.O.SHEET 8
105
PROTECT IN PLACENo conflicts anticipated this sheet.
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: S:\Cad\Renton\20-10723 Burnett-Williams\Design\dwgs\P20-10723_C-2-3 Burnett.dwgCITY OF
RENTON
Planning/Building/Public Works Dept.
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:
BHC Consultants, LLC
1601 Fifth Avenue, Suite 500
Seattle, Washington 98101
206.505.3400
206.505.3406 (fax)
www.bhcconsultants.com
45243STATE OF WASHING
T
ONR
EGIST E R E DP
R
OFESSIONAL ENG INE E R REBL DAYO
C
HI
LTREEECCA OVE BURNETT AVE S AND WILLIAMS AVE S
STORM SYSTEM IMPROVEMENTS
DECEMBER 2023
1-800-424-5555 or 811
UNDERGROUND SERVICE
Call 48 Hours
Before You Dig
SWP-27-4-88
BURNETT AVE S
PLAN AND PROFILE STA 5+75 TO 11+50 C-3
X X
R. OCHILTREE, P.E.
P. SIMON
HORIZ. 1" = 20'-0"
VERT. 1" = 5'-0"MATCHLINE STA - SEE DWG 5+75C-3MATCHLINE STA - SEE DWG 5+75 C-3
35
30
25
45
50
20
15
NOTES:
1. ALL EXISTING TYPE 1 CATCH BASINS AND
LATERALS SHALL BE REMOVED AND REPLACED
AS SHOWN.
2. KC WTD/METRO 108-INCH SEWER RANGES IN
DEPTH FROM 20 TO 25-FEET ALONG BURNETT
AVE S.
3. PROTECT ALL EXISTING UTILITIES IN PLACE
UNLESS DENOTED AS ABANDONED OR TO BE
REMOVED.
4. INSTALL ETHAFOAM PAD BETWEEN PIPES IF
CLEARANCE IS 6" OR LESS.
5. MAKE CONNECTIONS FROM NEW PIPES TO
EXISTING PIPES VIA COUPLING BANDS
(FERNCO OR SIMILAR).
6. CATCH BASIN TYPE 1 PER COR STD PLAN
200.00.
7. CATCH BASIN TYPE 2 PER COR STD PLAN
201.00.
8. CATCH BASIN INSTALLATION PER COR STD
PLAN 202.00.
9. LIMIT DISTURBANCE TO EXISTING SIDEWALKAND PLANTER STRIP TO THE EXTENT
NECESSARY FOR PIPE AND CATCH BASIN
INSTALLATION. ANY SIDEWALK DAMAGED BYOPERATION OF CONSTRUCTION EQUIPMENT
ON SIDEWALK SHALL BE REPLACED IN KIND BY
THE CONTRACTOR AT NO ADDITIONAL
EXPENSE TO THE CITY.
10. PIPES DENOTED AS PVC SHALL BE C900 PVC.
11. CONTRACTOR IS RESPONSIBLE FOR
PRESERVING, PROTECTING, AND TEMPORARY
BYPASS PROVISIONS AS NECESSARY TO
MAINTAIN UTILITIES AND SERVICE.
2
3
4
CONSTRUCTION NOTES:
FIELD VERIFY IF EXISTING GAS LINE
IS ACTIVE OR ABANDONED AT
LEAST 1 WEEK IN ADVANCE OF
TRENCHING IN THIS LOCATION. IF
ACTIVE PROTECT IN PLACE. IF
ACTIVE AND IN CONFLICT WITH
PROPOSED STORM DRAIN,
COORDINATE WITH PSE TO
RELOCATE. IF ABANDONED,
COORDINATE WITH PSE FOR
REMOVAL/ABANCONMENT
PROCEDURE.
PLUG AND CAP EXISTING STORM
DRAIN.
EXISTING WATER MAIN, PROTECT
IN PLACE.
CONNECT TO EXISTING STORM
DRAIN LATERAL.
ABANDON EXISTING CATCH BASIN
IN PLACE PER SP 7-05.3(2).
EXISTING SANITARY SEWER SHALL
BE REMOVED WHERE INDICATED
TO INSTALL PROPOSED STORM
DRAIN.
REMOVE EXISTING ABANDONED 4"
W AS NECESSARY TO INSTALL
PROPOSED STORM DRAIN AND CAP
EACH END AFTER
CUTTING/REMOVING.
PROTECT EXISTING THRUST
BLOCKS IN PLACE.
REMOVE EXISTING CATCH BASIN.
5
10
13
14
17
40
1
SDMH #B7RIM EL 37.50IE 31.8 - 18" IN (S)IE 31.8 - 18" OUT (N)IE 33.4 - 8" IN (E)SEE LATERAL PROFILE C/C-10SDMH #B8RIM EL 37.25IE 31.2 - 18" IN (S)IE 31.2 - 18" OUT (N)IE 34.4 - 12" IN (E)IE 31.8 - 8" IN (W)SEE LATERAL PROFILE D/C-10SDMH #B9RIM EL 36.83IE 29.9 - 18" IN (S)IE 29.9 - 18" OUT (NW)IE 30.6 - 8" IN (W)IE 31.7 - 8" IN (E)SEE LATERAL PROFILE E/C-1089 LF - 18" PP SD, S=0.7%188 LF - 18" PP SD
S=0.7%EX 6" W IE 32.51EX CT/F, EL UKNEX 4" W, IE 33.5EX G, EL UKN50
45
40
35
30
25
20
15
6+00 7+00 8+00 9+00 10+00 11+00
EX GRADE AT
C/L OF PIPE
ALIGNMENT
EX GRADE AT
C/L OF PIPE
ALIGNMENT
86 LF - 18" PP SD
S=0.7%IE 29.1 - 18" IN (SW)IE 27.9 - 18" OUT (E)IE 29.4 - 12" IN (S)SDMH #B12RIM EL 36.32IE 31.0 - 12" OUT (S)IE 33.5 - 12" IN (NW)IE 33.5 - 12" IN (NE)IE 31.1± - 8" IN (E)SEE LATERAL PROFILEG/C-10, H/C-10, AND V/C-1186 LF - 12" PP SD
S=1.9%EX EEX E3-EX EEX LT/FEX CT/FEX SSMH 0071RIM EL 37.11EX G, EL UKNIE 30.0 8" IN (S)EX IE 30.0 8" OUT (N)EX 1 1/8" G, EL UKN1
EX 6" W, IE 32.78" SS4" PVC TDUCIE 34.971
1
EX 5/8" G, EL UKN1
EX 108" KCWTD/METRO20' TO 25' DEEPEX 8" S, IE 26.8±EX 8" S, IE 28.3±EX 8" S, IE 26.2±27 LF -
18" PP SD
S=0.7%IE 29.3 - 18" IN (SE)IE 29.3 - 18" OUT (NE)EX G, EL UKN1
EX 108" KCWTD/METRO20' TO 25' DEEPEX 8" S, IE 26.3±SDMH #B11RIM EL 36.69EX 8" S, IE 26.6±SDMH #B10RIM EL 36.67EX G, EL UKNSEE DETAIL 1/C-13
FOR WATER
RELOCATION DETAILSTO BE RELOCATEDPRIOR TO SDINSTALLATIONEX 108" KCWTD/METRO20' TO 25' DEEP82104
95
S TILLICUM STBURNETT AVE S
S TOBIN ST36" SD
PP
SDMH #B7
TYPE 2 - 48"
STA 6+00.37 18" SD
PP
12" SD
DI
18" SD
PP
SDMH #B8
TYPE 2 - 48"
STA 6+88.70
SDMH #B9
TYPE 2 - 48"
STA 8+75.20
SDMH #B11
TYPE 2 - 60"
STA 9+89.05
18" SD
PP
12" SD
PP
SDMH #B12
TYPE 2 - 48"
STA 11+01.89
8" SD
PVC
18" SD
PP
PH #1
PH #2PH #3PH #4
12" SD
DI
40+0041+006+00 7+00 8+00
9+00
10+00 11+00103+00103+60104+00104+60105+00105+601 0 6 +0 0
1 0 6 +9 7
107
+00
107
+89
121+00 121+60 150+00150+608" SS
PVC
STATION EQUATION
BURNETT AVE S
STA 10+24.51
OFFSET 1.12' LT =
S TOBIN ST
STA 40+25.00
N 179484.71
E 1300572.85
CB #14
TYPE 1 W/ GRATE
STA 6+88.70
OFFSET 19.15' RT
CB #16
TYPE 1 W/ GRATE
STA 11+24.72
OFFSET 19.61' RT
CB #15
TYPE 1 W/ GRATE
STA 11+22.93
OFFSET 17.88' LT
PH #W2
PH #W3
PH #W4
1
8" SD
PVC
17
8" SD
PVC
10
3
8" SD
PVC
3
3
2
2
2
2
3
2
SEE DWG C-7CB #42
TYPE 1 W/ GRATE
STA 40+49.88
OFFSET 8.06' RT
CB #41
TYPE 1 W/ GRATE
STA 40+49.88
OFFSET 25.58' LT
PH #L1
PH #L2
PH #L3
PH #L4
PH #L5
12" SD
DI
12" SD
DI
SDMH #T1
TYPE 2 - 60"
STA 40+49.88
4
13
4
17 17
5
SDMH #B10
TYPE 2 - 48"
STA 9+61.59
18" SD
PP
4
PH #W5
2
17
8" SD
PVC
1 1
1
1
4
12" SD
DI
X X X X X X X X X
2 Aerial Cables on Joint Utility Poles1 Copper Cables - 200 PR
1 Fiber Cable - 48
Ped unksize unk
Ped 82-2size 6"1-term
aer-telaer-telaer-telaer-telaer-telaer-telaer-telaer-telaer-telaer-tel tductductductduc
CON-C-4IN-WHIT
1 Duct w/1 Copper Cable - 200 PR Ped 72size 4"
1-term: Busted
Ug. Cable 1-4" CBO300 PR Copper
Ped 60size 12481-term
tduc tduc tduc tduc tduc tduc
HH
tductductductductducCON-C-4IN-WHIT
1 Duct 300pr ug. copper
btel
1-4" PVCUg. Copper Cable
200 PR
PP. 317926-166036
P. 0100
A1365191
45'-4
0-wkg
PP. 317912-166036
P. 0100
A1365192
45'-4: 1-PMT,
4"-Riser, 1- DG&A tductducUnderground cable 1-4" CBO1 Fiber Cable - 24ct 2-wkg
tduc tduc tduc
tductduc10-wkg
tduc tduc tduc
Ug. Cable 1-4" PVC50 PR Copper
Ug. Cable 1-4" PVC50 PR Copper
HH 308
tduc
8-wkg
200PR bur. copper
8-wkg
TO C.O.
TO MH 203SEE SHT 10
Potential Conflict #1 [20']
Ug. Copper crossing proposed 18"Storm pipe. PH data shows Lumenat 26.5" depth (2'1" above Storm).
Protect in place.
20.91 in
Conflict #2 [20']
Ug. copper crossing proposed 18"Storm pipe. PH data shows
Lumen at 31" depth. Forte shows0-wkg. PROTECT IN PLACE.Conflict #3 [60']Ug. copper crossing proposed12" storm pipe & catch basin.
Needs depths & locates.
TO C.O.
24.59 in
31.00 in
4" PVC @ 26.5" DEPTH
4" PVC @ 31" DEPTH
4" PVC @ 26" DEPTH
4" PVC @ 30" DEPTH
30.00 in
44.00 in
106
Confirm HH size,location and facilities
Locate & confirm depth ofLumen 4" w/ 200pr
Deactivate/abandon existing50pr [JX5]
Deactivate/abandon existing50pr [JX5]
During construction, removeexisting pedestal, cut andabandon 50pr
Access Existing Ped #60 & trim out50pr [JX5] for abandonment
HORIZ. 1" = 20'-0"
VERT. 1" = 5'-0"MATCHLINE STA - SEE DWG 24+50 C-5MATCHLINE STA - SEE DWG 24+50 C-5
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: S:\Cad\Renton\20-10723 Burnett-Williams\Design\dwgs\P20-10723_C-4-5-6 Williams.dwgCITY OF
RENTON
Planning/Building/Public Works Dept.
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:
BHC Consultants, LLC
1601 Fifth Avenue, Suite 500
Seattle, Washington 98101
206.505.3400
206.505.3406 (fax)
www.bhcconsultants.com
45243STATE OF WASHING
T
ONR
EGIST E R E DP
R
OFESSIONAL ENG INE E R REBL DAYO
C
HI
LTREEECCA OVE BURNETT AVE S AND WILLIAMS AVE S
STORM SYSTEM IMPROVEMENTS
DECEMBER 2023
1-800-424-5555 or 811
UNDERGROUND SERVICE
Call 48 Hours
Before You Dig
SWP-27-4-88
WILLIAMS AVE S
PLAN AND PROFILE STA 20+00 TO 24+50 C-4
X X
R. OCHILTREE, P.E.
P. SIMON
HORIZ. 1" = 20'-0"
VERT. 1" = 5'-0"
CONSTRUCTION NOTES:
EXISTING WATER MAIN, PROTECT IN PLACE.
CONNECT TO EXISTING STORM DRAIN
LATERAL.
FIELD VERIFY IF THE EXISTING STORM DRAIN
LATERAL CONNECTION IS ACTIVE OR
ABANDONED AT LEAST 1 WEEK IN ADVANCE
OF TRENCHING IN THIS LOCATION. IF ACTIVE,
MAKE CONNECTION FROM EXISTING PIPE TO
NEW PIPE WITH NYOPLAST FITTING (OR
SIMILAR). IF ABANDONED, PLUG AND CAP.
EXISTING HIGH PRESSURE GAS LINE,
PROTECT IN PLACE.
PROTECT EXISTING TDUC IN PLACE.
3
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: S:\Cad\Renton\20-10723 Burnett-Williams\Design\dwgs\P20-10723_C-4-5-6 Williams.dwgCITY OF
RENTON
Planning/Building/Public Works Dept.
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:
BHC Consultants, LLC
1601 Fifth Avenue, Suite 500
Seattle, Washington 98101
206.505.3400
206.505.3406 (fax)
www.bhcconsultants.com
45243STATE OF WASHING
T
ONR
EGIST E R E DP
R
OFESSIONAL ENG INE E R REBL DAYO
C
HI
LTREEECCA OVE BURNETT AVE S AND WILLIAMS AVE S
STORM SYSTEM IMPROVEMENTS
DECEMBER 2023
1-800-424-5555 or 811
UNDERGROUND SERVICE
Call 48 Hours
Before You Dig
SWP-27-4-88
4
7
12
18
NOTES:
1. ALL EXISTING TYPE 1 CATCH BASIN AND
LATERALS SHALL BE REMOVED AND
REPLACED AS SHOWN.
2. PROTECT ALL EXISTING UTILITIES IN PLACE
UNLESS DENOTED AS ABANDONED OR TO BE
REMOVED.
3. INSTALL ETHAFOAM PAD BETWEEN PIPES IF
CLEARANCE IS 6" OR LESS.
4. MAKE CONNECTIONS FROM NEW PIPES TO
EXISTING PIPES VIA COUPLING BANDS
(FERNCO OR SIMILAR).
5. CATCH BASIN TYPE 1 PER COR STD PLAN
200.00.
6. CATCH BASIN TYPE 2 PER COR STD PLAN
201.00.
7. CATCH BASIN INSTALLATION PER COR STD
PLAN 202.00.
8. LIMIT DISTURBANCE TO EXISTING SIDEWALK
AND PLANTER STRIP TO THE EXTENT
NECESSARY FOR PIPE AND CATCH BASIN
INSTALLATION. ANY SIDEWALK DAMAGED BY
OPERATION OF CONSTRUCTION EQUIPMENT
ON SIDEWALK SHALL BE REPLACED IN KIND
BY THE CONTRACTOR AT NO ADDITIONAL
EXPENSE TO THE CITY.
9. PIPES DENOTED AS PVC SHALL BE C900 PVC.
10. CONTRACTOR IS RESPONSIBLE FOR
PRESERVING, PROTECTING, AND
TEMPORARY BYPASS PROVISIONS AS
NECESSARY TO MAINTAIN UTILITIES AND
SERVICE.
20+00 21+00 22+00 23+00 24+00
40
35
30
25
20
15
45
40
35
30
25
20
15
45
EX IE 35.7 - 12" OUT (N)CB #W2RIM EL 39.47IE 35.4 - 8" IN (S)IE 35.4 - 8" OUT (N)SDMH #W3RIM EL 39.49IE 35.2 - 8" IN (S)IE 33.4 - 12" OUT (N)IE 37.2 - 12" IN (W)IE 35.0 - 12" IN (SE)SEE LATERAL PROFILE I/C-10SDMH #W4RIM EL 38.89IE 33.2 - 12" IN (S)IE 33.2 - 12" OUT (N)IE 36.9 - 6" IN (W)SEE LATERAL PROFILE J/C-11SDMH #W5RIM EL 39.13IE 32.9 - 12" IN (S)IE 32.9 - 12" OUT (N)IE 35.3 - 8" IN (W)SEE LATERAL PROFILE K/C-11SDMH #W6RIM EL 39.48IE 32.8 - 12" IN (S)IE 32.8 - 12" OUT (N)IE 36.4 - 8" IN (W)SEE LATERAL PROFILE L/C-11EX GRADE AT C/L OF
PIPE ALIGNMENT
77 LF - 8" PVC SD
S=0.5%
47 LF - 8" PVC SD
S=0.5%
S=0.16%
66 LF - 12" PP SD
S=0.5%
97 LF - 12" PP SD
S=1.2%S=0.5%
25 LF
12" PP SDEX LT/FEX GEX CT/FEX GEX W - TO FHEX GEX LT/FEX 6" S, IE 34.0EX 8" W, IE 33.1EX 1 1/4" G, IE 36.5,TO BE RELOCATEDBY OTHERS PRIORTO CONSTRUCTIONEX 8" W, IE 36.4,EX 6" S, IE 34.4EX E, EL UKNEX 3/4" W, EL UKNEX E, EL UKNEX 6" SIE 34.7EX 6" S, IE 34.9EX 6" S, IE 34.9EX 5/8" G, IE 36.2EX E, EL UKNEX 5/8" G, IE 36.1EX 6" S, IE 35.5EX 6" S, IE 35.6EX E, EL UKNEX 6" S, IE 36.8EX LT/FEX GEX IE 38.01 - 8" IN (E)EX IE 35.90 - 12" OUT (N)EX 3/4" W, EL UKNEX CB TYPE 1LRIM 39.70EX CB TYPE 1LEX 6" S, IE 35.1EX IE 35.64 - 12" IN (S)EX IE 37.04 - 8" IN (W)EX IE 35.64 - 12" IN (E)IE 35.8 - 8" OUT (N)EX 5/8" G, IE 37.4CLEARANCE
34.7 TO 35.2 = 6"
CLEARANCE
34.9 TO 35.3 = 4.8"
CLEARANCE
34.7 TO 34.3 = 4.8"
115 LF
12" PP SDEX 6" S, IE 34.2EX CB TYPE 1LEX WEX CT/FSEE DETAIL 1/C-13
FOR WATER
RELOCATION
DETAILS TO BE RELOCATEDPRIOR TO SDINSTALLATIONETHAFOAM
PAD
20+00 21+00 22+00 23+00 24+00110+00110+60111+00111+66120+00120+63109+00109+66107710104
858
124 116 110
WILLIAMS AVE S
8" SD
PVC
8" SD
PVC
12" SD
PP
12" SD
PP
12" SD
PP
12" SD
PP
CB #20
TYPE 1 W/ GRATE
STA 21+44.94
SDMH #W3
TYPE 2 - 48"
STA 21+91.80
SDMH #W4
TYPE 2 - 48"
STA 23+06.40
SDMH #W5
TYPE 2 - 48"
STA 23+72.64
SDMH #W6
TYPE 2 - 48"
STA 23+97.81
12" SD
DI
CB #21
TYPE 1 W/ GRATE
STA 21+91.80
OFFSET 34.39' LT
7
PH #W7
PH #W6
PH #W8S 2ND ST123 3
6" SD
DI 12
8" SD
PVC
8" SD
PVC
PH #L6
PH #L7
PH #L8
PH #L9
PH #L10
18
4 4
CB #11
TYPE 1 W/ GRATE
STA 21+83.37
OFFSET 3.67' RT
12" SD
PP4
Manhole # 10 & 144
HH
tductductductducHH # UN-92463-TAIN NW CORNERSIDEWALK 7.5'FROM EOC
HH # UN-94
463-TAIN NE CORNER
SIDEWALK 3.0' BEHINDPLANTER BOXtductductductductduc CON-C-4IN-WHIT1 Duct w/1 Copper Cable - 100 PR
tductduc
HH
HH # UN-71463-TA
IN SIDEWALK 4.0'BEHIND LOADINGZONE SIGN.
tductductductductductductductductductductductductductductductductductductductductduc
tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tductductductductductductductductductductductductductductductductductductductductductduc
FSC [BERMICO]
7 Ducts w/4 Copper Cables - 300 PR to 3600 PR
4 Fiber Cables - 24 to 216
TK-TRANSITE8 Ducts4 Copper Cables - 900 PR to 2400 PR1 Fiber Cable - 36
1 Duct w/1 Copper Cable - 100 PR
HH # UN-97463-TA: 1-TermIN SIDEWALK5.5' FROM EOC
tduc tduc tduc tduc tduc tduc tduc tduc
1 Duct w/1 Copper Cable - 100 PR
Handhole # 31221-term
HALF WAY INSIDEWALK 1.5'FROM EOC.
tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc
1 Duct w/1 Copper Cable - 100 PR
TO RENTON WIRE CENTER225 WILLIAMS AVE S
tduc
TO MH 193SHEET 6
TO FIELDTO MH 334
MH # 2-23.5'x8'x5.5'
IN SE CORNERSIDEWALK
34"W x 14" D concrete Duct@ 36" to top of Duct
16"W x 21" D concrete Duct@ 41" to top of Duct
18"W x 21" D concrete Duct@ 36" to top of Duct
4" PVC @ 34" DEPTH
22"W x 22" D concrete Duct@ 31" to top of Duct
HH HH
Conflict #4 [20']
Ug. Duct run crossing proposed12" storm pipe & catch basin.Potholing and profile above
suggest 12" Storm pipe beingplaced over duct run.
Protect duct run in place.
HH
HH
tduc tduc tduc
1 Duct 4" CBO w/1 Copper Cable - 100 PR tductducHH # UN-93
463-TAIN PAVED
PARKING LOT12.0' FROM EOC Conflict #5 [20']
Ug. Duct crossing proposed 8"storm pipe connecting toexisting. Ex. Lumen Not on
profile above suggest depth& locate in field.
107
FIELD TO VERIFY DEPTH &
LOCATION OF 100pr COPPER.
Locate & confirm depth of Lumen4", check against SD IEPROTECT IN PLACENo conflicts anticipated this sheet.
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: S:\Cad\Renton\20-10723 Burnett-Williams\Design\dwgs\P20-10723_C-4-5-6 Williams.dwgCITY OF
RENTON
Planning/Building/Public Works Dept.
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:
BHC Consultants, LLC
1601 Fifth Avenue, Suite 500
Seattle, Washington 98101
206.505.3400
206.505.3406 (fax)
www.bhcconsultants.com
45243STATE OF WASHING
T
ONR
EGIST E R E DP
R
OFESSIONAL ENG INE E R REBL DAYO
C
HI
LTREEECCA OVE BURNETT AVE S AND WILLIAMS AVE S
STORM SYSTEM IMPROVEMENTS
DECEMBER 2023
1-800-424-5555 or 811
UNDERGROUND SERVICE
Call 48 Hours
Before You Dig
SWP-27-4-88
WILLIAMS AVE S
PLAN AND PROFILE STA 24+50 TO 29+50 C-5
X X
R. OCHILTREE, P.E.
P. SIMON
HORIZ. 1" = 20'-0"
VERT. 1" = 5'-0"MATCHLINE STA - SEE DWG 24+50 C-4MATCHLINE STA - SEE DWG 24+50 C-4MATCHLINE STA - SEE DWG 29+50C-6MATCHLINE STA - SEE DWG 29+50 C-6
NOTES:
1. ALL EXISTING TYPE 1 CATCH BASIN AND
LATERALS SHALL BE REMOVED AND
REPLACED AS SHOWN.
2. PROTECT ALL EXISTING UTILITIES IN PLACE
UNLESS DENOTED AS ABANDONED OR TO BE
REMOVED.
3. INSTALL ETHAFOAM PAD BETWEEN PIPES IF
CLEARANCE IS 6" OR LESS.
4. MAKE CONNECTIONS FROM NEW PIPES TO
EXISTING PIPES VIA COUPLING BANDS
(FERNCO OR SIMILAR).
5. CATCH BASIN TYPE 1 PER COR STD PLAN
200.00.
6. CATCH BASIN TYPE 2 PER COR STD PLAN
201.00.
7. CATCH BASIN INSTALLATION PER COR STD
PLAN 202.00.
8. LIMIT DISTURBANCE TO EXISTING SIDEWALK
AND PLANTER STRIP TO THE EXTENT
NECESSARY FOR PIPE AND CATCH BASIN
INSTALLATION. ANY SIDEWALK DAMAGED BY
OPERATION OF CONSTRUCTION EQUIPMENT
ON SIDEWALK SHALL BE REPLACED IN KIND BY
THE CONTRACTOR AT NO ADDITIONAL
EXPENSE TO THE CITY.
9. PIPES DENOTED AS PVC SHALL BE C900 PVC.
10. CONTRACTOR IS RESPONSIBLE FOR
PRESERVING, PROTECTING, AND TEMPORARY
BYPASS PROVISIONS AS NECESSARY TO
MAINTAIN UTILITIES AND SERVICE.
CONSTRUCTION NOTES:
FIELD VERIFY IF EXISTING GAS LINE IS ACTIVE
OR ABANDONED AT LEAST 1 WEEK IN
ADVANCE OF TRENCHING IN THIS LOCATION. IF
ACTIVE, PROTECT IN PLACE. IF ACTIVE AND IN
CONFLICT WITH PROPOSED STORM DRAIN,
COORDINATE WITH PSE TO RELOCATE. IF
ABANDONED, COORDINATE WITH PSE FOR
REMOVAL/ABANDONMENT PROCEDURE.
PLUG AND CAP EXISTING STORM DRAIN.
EXISTING WATER MAIN, PROTECT IN PLACE.
CONNECT TO EXISTING STORM DRAIN
LATERAL.
FIELD VERIFY IF THE EXISTING STORM DRAIN
LATERAL CONNECTION IS ACTIVE OR
ABANDONED AT LEAST 1 WEEK IN ADVANCE
OF TRENCHING IN THIS LOCATION. IF ACTIVE,
MAKE CONNECTION FROM EXISTING PIPE TO
NEW PIPE WITH NYOPLAST FITTING (OR
SIMILAR). IF ABANDONED, PLUG AND CAP.
EXISTING HIGH PRESSURE GAS LINE,
PROTECT IN PLACE.
1
3
7
2
4
12
25+00 26+00 27+00 28+00 29+00
40
35
30
25
20
15
40
35
30
25
20
45
15
45
SDMH #W7RIM EL 39.05IE 31.6 - 12" IN (S)IE 31.6 - 12" OUT (N)IE 35.0 - 12" IN (NE)SEE LATERAL PROFILE T/C-11SDMH #W8RIM EL 39.39IE 31.3 - 12" IN (SE)IE 30.8 - 18" OUT (N)IE 37.1 - 12" IN (W)SEE LATERAL PROFILE M/C-11SDMH #W9RIM EL 38.85IE 30.3 - 18" IN (S)IE 30.3 - 18" OUT (N)IE 36.4 - 12" IN (W)IE 35.8 - 12" IN (E)SEE LATERAL PROFILE N/C-11SDMH #W11RIM EL 37.77IE 26.6 - 24" IN (W)IE 26.6 - 24" OUT(N)SDMH #W10RIM EL 38.3389 LF - 18" PP SD
S=0.5%
227 LF - 18" PP SD
S=0.5%
EX GRADE AT C/L OF
PIPE ALIGNMENTEX 6" S, IE 36.1EX 3/4" W, EL UKNEX 5/8" G, IE 35.89EX 3/4" W, EL UKNEX 3/4" W, EL UKNEX 3/4" W, EL UKNEX 3/4" W, EL UKNEX 3/4" W, EL UKNEX E, EL UKNEX G, EL UKNWILLIAMS MWS-LINEARMODULAR WETLANDEX 1 1/2" G, IE 34.691
EX 3/4" W, EL UKNEX W, EL UKNEX 1 1/4" G, IE 36.68EX 1/2" G, EL UKNEX 5/8" G, IE 36.3EX 3/4" W, EL UKNEX 5/8" G, IE 35.6428 LF 12"
PP SD
S=1.2%
11 LF 18" PP SD
S=0.5%IE 28.6 - 18" IN (N)IE 26.7 - 24" OUT (E)IE 26.7 - 36" IN (W)SDMH #T4RIM EL 37.9622 LF
24" PP SD
S=0.25%EX 12" STW G, EL UKNEX 12" W, IE 33.2±21 LF
18" PP SD
S=0.5%IE 29.1 - 18" IN (S)IE 29.1 - 18" OUT (N)IE 35.4 - 12" IN (W)IE 34.4 - 12" IN (E)SEE LATERAL PROFILE P/C-11IE 29.0 - 18" IN (S)IE 28.7 - 18" OUT (N)SEE DWG C-984 LF
24" PP SD
S=0.25%EX 12" W, IE 31.5±EX 12" G, IE 36.2±EX 6" W, IE 33.4CLEARANCE
33.4' - 32.9' = 6''
ETHAFOAM
PADS
CLEARANCE
33.2' - 32.4' = 10"25+0026+00 27+00 28+00
29+0043+0043+50112+00112+50113+00113+60114+00114+60140+00
140+50
798187919599101 75
98 94 84 82 78 74 66
WILLIAMS AVE S
STATION CONTROL
STA 28+91.97=
S TOBIN ST
STA 43+15.29
N 179466.7320
E 1300866.6916S TOBIN STSDMH #W7
TYPE 2 - 48"
STA 24+95.25
12" SD
DI
12" SD
DI
12" SD
DI
SDMH #W10
TYPE 2 - 48"
STA 28+46.95
18" SD
PP
CB #26
TYPE 1 W/ GRATE
STA 28+46.95
OFFSET 25.35' LT
36" SD
PP
CB #25
TYPE 1 W/ GRATE
STA 28+46.95
OFFSET 12.73' LT
18" SD
PP
WILLIAMS MWS-LINEAR
MODULAR WETLAND,
SEE DWG C-9
13' x 9'
PH #10
PH #9
PH #8
PH #7
SDMH #W9
TYPE 2 - 48"
STA 26+20.17
12" SD
DI
24" SD
PP
CB #23
TYPE 1 W/ GRATE
STA 26+20.81
OFFSET 12.76' LT
CB #24
TYPE 1 W/ GRATE
STA 26+18.85
OFFSET 25.30' RT
1 SEE DWG C-712" SD
DI
12
7
CB #22
TYPE 1 W/ GRATE
STA 25+20.98
OFFSET 12.72' LT
12" SD
PP
SDMH #W8
TYPE 2 - 48"
STA 25+20.98
12" SD
PP
2
2
2
2
3
3
12
18" SD
PP
INSTALL NEW
12" GATE VALVE
SDMH #W11
TYPE 2 - 48"
STA 29+13.84SDMH #T4
TYPE 2 - 60"
STA 28+91.97
PH #L12
PH #L13
PH #L14
PH #L15
PH #L16
PH #L17
2
12
CB #28
TYPE 1 W/ GRATE
STA 24+98.14, LT 11.2'
12" SD
PP
Potential Conflict w/
Duct &Proposed Storm Drain
See sheet 11
Manhole # 11-18'x4'x6'IN PAVEMENT5.0' FROM EOC
Manhole # 2025'x10.5'x6.2' IN SIDEWALK6.0' FROM EOC
tductductduc
tductductductductduc
tductductductductductductductductductductductductductductductductductductductductduc
1 Duct w/
1 Copper Cable - 100 PR
tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc
TK-TRANSITE8 Ducts4 Copper Cables - 900 PR to 2400 PR1 Fiber Cable - 36
FSC7 Ducts w/3 Copper Cables - 2400 PR to 3600 PR4 Fiber Cables - 24 to 2161 Duct w/
1 Copper Cable - 100 PRBuried Copper Cable
300 PR
tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tduc tductductductductductductductductductductductductductductductductductduc
18"W x 24"D concrete Duct
@ 36" to top of Duct
4" PVC @ 42" DEPTH
22"W x 26"D concrete Duct@ 30" to top of Duct
18"W x 22"D concrete Duct@ 34" to top of Duct
18"W x 21"D concrete Duct@ 31" to top of Duct 18"W x 22"D concrete Duct@ 33" to top of Duct
Conflict #6 [20']Ug. Duct run crossing proposed12" Storm pipe. PH Data
suggests 12" SD will be placedover Duct run.
Protect duct run in place.
Conflict #7
MH 11-1 in proposed pavedarea. Protect in place &
adjust as needed.
Conflict #8 [20']Ug. Duct run crossing proposed
12" Storm pipe. PH Data &Profile N above suggests 12" SD
will be placed over Duct run. Protect duct run in place.
Conflict #9 [20']Ug. Duct run crossing proposed
12" Storm pipe. PH Data &profile P above suggests 12" SD
will be placed over Duct run. Protect duct run in place.
TO C.O.
108
Handhole # 96
1-termHALF WAY INSIDEWALK 1.5'FROM EOC.
HH
Handhole # 86
1-termHALF WAY INSIDEWALK 1.5'FROM EOC.
HH
1 Duct w/
1 Copper Cable - 100 PR
HH
Handhole # 801-termHALF WAY INSIDEWALK 2.0'FROM EOC.
HH
Handhole # 81
1-termIN SIDEWALK3.5' FROM EOC.
HH
Handhole # 89
1-termIN SIDEWALK3.0' FROM EOC.
HH
Handhole # 97
1-termIN SIDEWALK2.0' FROM EOC.HHHandhole # 105
1-termIN SIDEWALK 2.5'FROM EOC.
PROTECT IN PLACENo conflicts anticipated this sheet.
Adjust manhole for grind &overlay
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: S:\Cad\Renton\20-10723 Burnett-Williams\Design\dwgs\P20-10723_C-4-5-6 Williams.dwgCITY OF
RENTON
Planning/Building/Public Works Dept.
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:
BHC Consultants, LLC
1601 Fifth Avenue, Suite 500
Seattle, Washington 98101
206.505.3400
206.505.3406 (fax)
www.bhcconsultants.com
45243STATE OF WASHING
T
ONR
EGIST E R E DP
R
OFESSIONAL ENG INE E R REBL DAYO
C
HI
LTREEECCA OVE BURNETT AVE S AND WILLIAMS AVE S
STORM SYSTEM IMPROVEMENTS
DECEMBER 2023
1-800-424-5555 or 811
UNDERGROUND SERVICE
Call 48 Hours
Before You Dig
SWP-27-4-88
WILLIAMS AVE S
PLAN AND PROFILE STA 29+50 TO 31+14.97 C-6
X X
R. OCHILTREE, P.E.
P. SIMON
HORIZ. 1" = 20'-0"
VERT. 1" = 5'-0"MATCHLINE STA - SEE DWG 29+50C-5MATCHLINE STA - SEE DWG 29+50 C-5
CONSTRUCTION NOTES:
PLUG AND CAP EXISTING STORM DRAIN.
EXISTING WATER MAIN, PROTECT IN PLACE.
EXISTING HIGH PRESSURE GAS LINE,
PROTECT IN PLACE.
PROTECT EXISTING TDUC IN PLACE.
2
3
NOTES:
1. ALL EXISTING TYPE 1 CATCH BASIN AND
LATERALS SHALL BE REMOVED AND
REPLACED AS SHOWN.
2. PROTECT ALL EXISTING UTILITIES IN PLACE
UNLESS DENOTED AS ABANDONED OR TO BE
REMOVED.
3. INSTALL ETHAFOAM PAD BETWEEN PIPES IF
CLEARANCE IS 6" OR LESS.
4. MAKE CONNECTIONS FROM NEW PIPES TO
EXISTING PIPES VIA COUPLING BANDS
(FERNCO OR SIMILAR).
5. CATCH BASIN TYPE 1 PER COR STD PLAN
200.00.
.
6. CATCH BASIN TYPE 2 PER COR STD PLAN
201.00.
7. CATCH BASIN INSTALLATION PER COR STD
PLAN 202.00.
8. LIMIT DISTURBANCE TO EXISTING SIDEWALK
AND PLANTER STRIP TO THE EXTENT
NECESSARY FOR PIPE AND CATCH BASIN
INSTALLATION. ANY SIDEWALK DAMAGED BY
OPERATION OF CONSTRUCTION EQUIPMENT
ON SIDEWALK SHALL BE REPLACED IN KIND
BY THE CONTRACTOR AT NO ADDITIONAL
COST EXPENSE TO THE CITY.
9. PIPES DENOTED AS PVC SHALL BE C900 PVC.
10. CONTRACTOR IS RESPONSIBLE FOR
PRESERVING, PROTECTING, AND
TEMPORARY BYPASS PROVISIONS AS
NECESSARY TO MAINTAIN UTILITIES AND
SERVICE.
12
18
30+00 31+00
40
35
30
25
20
15
45
40
35
30
25
20
15
45
SDMH #W12RIM EL 37.4584 LF
24" PP SD
S=0.25%
EX GRADE AT C/L OF
PIPE ALIGNMENT
OUTFALL
IE 25.3SDMH #W14RIM EL 36.92CARRY-THROUGHSTRUCTUREEX G, EL UKNEX G, EL UKN66 LF
24" PP SD
S=0.25%SDMH #W13RIM EL 37.07IE 26.4 - 24" IN (SE)IE 26.4 - 24" OUT (NE)IE 26.2 - 24" IN (S)IE 26.2 - 24" OUT (NW)SDMH #W16RIM EL 37.14IE 26.0 - 24" IN (SE)EX IE 26.0 - 12" OUT (N)EX IE 26.0 - 12" IN (S)24 LF
24" PP SD
S=0.25%EX 12" W, EL UKNEX CONC DUCTEX CONC DUCTEX G, EL UKNEX P, EL UKN11 LF 24" PP SD
S=0.25%
15 LF 24" PP SD
S=0.25%EX 12" CONC
OUTFALLEX 24" W, IE 29.8±CLEARANCE
29.8' TO 28.4' = 16.8"IE 26.5 - 24" IN (S)IE 26.5 - 24" OUT (NE)IE 34.2 - 12" IN (W)SEE LATERAL PROFILE U/C-11IE 26.3 - 24" IN (SW)IE 26.3 - 24" OUT (N)EX SS IE 27.4 - 8" IN (E)EX SS IE 27.4 - 8" OUT (W)PER DETAIL 1/C-12SDMH #W15RIM EL 37.1230+00 31+00115+00115+60720 55720
S TILLICUM STWILLIAMS AVE S
SDMH #W16
TYPE 2 - 48"
STA 31+14.97
SDMH #W12
TYPE 2 - 48"
STA 29+97.77
24" SD
PP 24" SD
PP
PH #W9
2
PH #L18
PH #L19
PH #L24
PH #L23
PH #L20
PH #L21
PH #L22
12
3
2
SDMH #W13
TYPE 2 - 48"
W/ GRATE
STA 30+13.39
SDMH #W14
TYPE 2 - 60"
STA 30+37.68
24" SD
PP
SDMH #W15
TYPE 2 - 48"
STA 30+51.05
CB #27
TYPE 1 W/ GRATE
STA 29+97.77, 34.5' LT
24" SD
PP
12" SD
DI
24" SD
PP
18
Manhole # 2035'x10.5'x6.2'IN SW CORNERSIDEWALK 2.5'FROM EOC
Manhole # 128'x4'x6'IN PAVEMENT
1.5' FROM EOC
tduc tduc tduc
tduc tduc tduc
tduc tduc tduc tduc tduc
tduc
tduc
tduc
CON-B-4IN-GRAY
10 Ducts w/2 Copper Cables - 2400 PR & 3600 PR
4 Fiber Cable - 24 to 216
tduc
tdu
c
tduc
tduc
tductductductducCON-C-4IN-WHIT1 Duct
300pr ug. copper
TO PED 60
SEE SHT 7
tduc
4IN-STEEL PIPE
8 Duct 2-2400pr ug. copper
1500pr ug. copper1200pr ug. copper
900pr ug. copper36ct ug. fiber
FSC
7 Ducts w/3 Copper Cables - 2400 PR to 3600 PR4 Fiber Cables - 24 to 2161 Duct w/1 Copper Cable - 100 PRBuried Copper Cable300 PR
TK-TRANSITE
8 Ducts4 Copper Cables - 900 PR to 2400 PR
1 Fiber Cable - 36
2" PVC @ 25" DEPTH
36"W x 28"D concrete Duct@ 44" to top of Duct
36"W x 21"D concrete Duct@ 23" to top of Duct
20"W x 12"D concrete Duct@ 17" to top of Duct
36"W x 12"D concrete Duct@ 48" to top of Duct
18"W x 4"D concrete Duct@ 20" to top of Duct
18"W x 4"D concrete Duct@ 18" to top of Duct
44.00 in
28.00 in
23.00 in
21.00 in
Conflict #10 [20']Ug. Duct run crossing proposed
12" Storm pipe. PH Datasuggests 12" SD will be placed
over Duct run. Protect duct run in place.
Conflict #11 [20']
Ug. Duct run crosses withstorm pipe capping.
Protect duct run in place.
Conflict #12 [20']Ug. Duct run crossing
proposed 24" Storm pipe.Profile & Google Drive-Bysuggest that Lumen facilitieswill be above proposed 24"Storm pipe.
Protect duct run in place.
Conflict #13 [20']
Ug. Duct run crossing proposed24" Storm pipe. Profile &
Google Drive-By suggest thatLumen facilities will be aboveproposed 24" Storm pipe.
Protect duct run in place.
109
HH
Handhole # 60
1-termBETWEENSIDEWALK &CURB 0.5' FROMEOC.
tductductduc
CON-B-4IN-GRAY10 Ducts w/
2 Copper Cables - 2400 PR & 3600 PR4 Fiber Cable - 24 to 216
HH
Handhole # 63
1-termIN SIDEWALK3.0' FROM EOC.
PROTECT IN PLACENo conflicts anticipated this sheet.
HORIZ. 1" = 20'-0"
VERT. 1" = 5'-0"
DATE:
DRAWING NO:
SHEET:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:
SURVEYED:FILENAME: S:\Cad\Renton\20-10723 Burnett-Williams\Design\dwgs\P20-10723_C-7 Tobin.dwgCITY OF
RENTON
Planning/Building/Public Works Dept.
SCALE:
COR PROJECT NO:
NO.REVISION BY DATE APPR OF:
BHC Consultants, LLC
1601 Fifth Avenue, Suite 500
Seattle, Washington 98101
206.505.3400
206.505.3406 (fax)
www.bhcconsultants.com
45243STATE OF WASHING
T
ONR
EGIST E R E DP
R
OFESSIONAL ENG INE E R REBL DAYO
C
HI
LTREEECCA OVE BURNETT AVE S AND WILLIAMS AVE S
STORM SYSTEM IMPROVEMENTS
DECEMBER 2023
1-800-424-5555 or 811
UNDERGROUND SERVICE
Call 48 Hours
Before You Dig
SWP-27-4-88
S TOBIN ST
PLAN AND PROFILE STA 40+00 TO 43+50 C-7
X X
R. OCHILTREE, P.E.
P. Simon
NOTES:
1. ALL EXISTING TYPE 1 CATCH BASIN AND
LATERALS SHALL BE REMOVED AND
REPLACED AS SHOWN.
2. PROTECT ALL EXISTING UTILITIES IN PLACE
UNLESS DENOTED AS ABANDONED OR TO BE
REMOVED.
3. INSTALL ETHAFOAM PAD BETWEEN PIPES IF
CLEARANCE IS 6" OR LESS.
4. MAKE CONNECTIONS FROM NEW PIPES TO
EXISTING PIPES VIA COUPLING BANDS
(FERNCO OR SIMILAR).
5. CATCH BASIN TYPE 1 PER COR STD PLAN
200.00.
6. CATCH BASIN TYPE 2 PER COR STD PLAN
201.00.
7. CATCH BASIN INSTALLATION PER COR STD
PLAN 202.00.
8. LIMIT DISTURBANCE TO EXISTING SIDEWALK
AND PLANTER STRIP TO THE EXTENT
NECESSARY FOR PIPE AND CATCH BASIN
INSTALLATION. ANY SIDEWALK DAMAGED BY
OPERATION OF COSTRUCTION EQUIPMENT
ON SIDEWALK SHALL BE REPLACED IN KIND
BY THE CONTRACTOR AT NO ADDITIONAL
EXPENSE TO THE CITY.
9. PIPES DENOTED AS PVC SHALL BE C900 PVC.
10. CONTRACTOR IS RESPONSIBLE FOR
PRESERVING, PROTECTING, AND
TEMPORARY BYPASS PROVISIONS AS
NECESSARY TO MAINTAIN UTILITIES AND
SERVICE.
CONSTRUCTION NOTES:
PLUG AND CAP EXISTING STORM DRAIN.
CONNECT TO EXISTING STORM DRAIN
LATERAL.
REMOVE EXISTING CATCH BASIN.
PROTECT EXISTING TDUC IN PLACE.
2
4
17
18
29+00 30+0040+00 41+00 42+00 43+00 43+50
9+0010+00121+00121+60130+00130+61150+00 150+60
WILLIAMS AVE SSTATION CONTROL
S TOBIN ST
STA 43+15=
WILLIAMS AVE S
STA 28+94.28
N 179466.73
E 1300866.69
S TOBIN STSTATION CONTROL
S TOBIN ST
STA 40+20=
BURNETT AVE S
STA 10+15.72
N 179475.95
E 1300571.55
SDMH #B10
TYPE 2 - 48"
SDMH #T2
TYPE 2 - 60"
STA 41+59.55
12" SD
DI
36" SD
PP
36" SD
PP
SDMH #B11
TYPE 2 - 60"
STA 40+18.25
SDMH #T4
TYPE 2 - 60"
STA 43+15.04
12" SD
DI
TOBIN MWS-LINEAR
MODULAR WETLAND,
SEE DWG C-8
21' x 9'BURNETT AVE SCB #43 - TYPE 1
STA 41+62.84
OFFSET 26.61' LT
12" SD
DI
12" SD
DI
CB #44 - TYPE 1
STA 41+62.84
OFFSET 7.49' RT
PH #8
PH #2
PH
#1
CB #41 - TYPE 1
STA 40+49.95
OFFSET 25.58' LT
CB #42 - TYPE 1
STA 40+49.85
OFFSET 8.06' RT
2
2
2
2
2
2
2
36" SD
PP
18" SD
PP
WILLIAMS MWS-LINEAR
MODULAR WETLAND,
SEE DWG C-9
13' x 9'SEE DWG C-3SEE DWG C-5SDMH #T1
TYPE 2 - 60"
STA 40+49.88
SDMH #W11
TYPE 2 - 48"
STA 43+36.91, 0.58' LT
17
24" SD
PP
PH #L3
PH #L14
PH #L15
PH #L16
PH #L17
PH #L24
SDMH #T3
TYPE 2 - 72"
STA 41+59.55
18
4
8" SD
PVC
18
2
15
20
25
30
35
40
45
50
15
20
25
30
35
40
45
50
40+00 41+00 42+00 43+00
EX GRADE AT
C/L OF PIPE
ALIGNMENT
109 LF - 36" PP SD
S=0.25%
100 LF - 36" PP SD
S=0.25%SDMH #T2RIM EL 37.22IE 29.1 - 18" IN (SW)IE 29.4 - 12" IN (N)IE 27.9 - 18" OUT (E)SDMH #T4RIM EL 37.96IE 28.6 - 18" IN (N)IE 26.7 - 24" OUT (E)IE 26.7 - 36" IN (W)EX P/TEL/TV DUCTEX 24" W, IE 30.6SDMH #B11RIM EL 36.741 1/4" EX G, IE 34.63EX 8" PVC S, IE 26.74±TOBIN MWS-LINEARMODULAR WETLAND23 LF
36" PP SDEX 6" CONC SD, IE 35.0±EX ES=0.25%IE 27.8 - 18" OUT (W)IE 27.8 - 36" OUT (E)IE 33.5 - 12" IN (NE)IE 33.5 - 12" IN (SE)SEE LATERALPROFILE F/C-10EX 8" W, IE 30.2EX 4" W (ABANDONED)EX 2" GAS, IE 33.2±TO BE RELOCATEDBY OTHERS PRIORTO CONSTRUCTION12" EX G, IE 32.65EX 12" W, IE 31.56EX 8" CONC SD, IE 34.1TO BE ABANDONEDSDMH #W11RIM EL 37.77IE 26.6 - 24" IN (W)IE 26.6 - 24" OUT(N)18 LF - 24"
PP SD
S=0.25%IE 27.3 - 36" IN (W)IE 27.0 - 36" OUT (E)SEE DWG C-8SDMH #T1RIM EL 36.59EX 4" PVC, IE 33.7TO BE RELOCATEDBY OTHERS PRIORTO CONSTRUCTIONEX 18'' W x 24'' D CONC DUCTIE 34.53IE 27.5 - 36" IN (W)IE 27.5 - 36" OUT (E)IE 34.1 - 12" IN (N)IE 34.1 - 12" IN (S)SEE LATERALPROFILE S/C-11SDMH #T3RIM EL 37.29CARRY-THROUGHSTRUCTUREIE 27.4 - 36" IN (W)IE 27.4 - 36" OUT (E)EX SS IE 27.2± - 8" OUT (N)EX SS IE 27.2± - 8" IN (S)PER DETAIL 2/C-128 LF 36" PP SD
S=0.25%
CLEARANCE
29.4 TO 30.6 = 1'-2"
CLEARANCE
30.2 TO 29.4 = 10"
32 LF
18" PP
SD
S=0.25%
Conflict #14 [30']
Ug. Duct run crossing proposed36" Storm pipe. PH Data &
profile below suggests 36" SDwill be placed over Duct run. Protect duct run in place.tductductductductductductductductduc1 Duct w/1 Copper Cable - 100 PRtductductductductductductductductducTK-TRANSITE
8 Ducts4 Copper Cables - 900 PR to 2400 PR
1 Fiber Cable - 36
FSC7 Ducts w/
3 Copper Cables - 2400 PR to 3600 PR4 Fiber Cables - 24 to 216
1 Duct w/1 Copper Cable - 100 PR
Buried Copper Cable300 PR
tductductductductductductductductductductductductductductductductduc18"W x 24"D concrete Duct@ 36" to top of Duct
4" PVC @ 42" DEPTH
22"W x 26"D concrete Duct@ 30" to top of Duct
18"W x 22"D concrete Duct@ 34" to top of Duct
42.00 in 36.00 in
31.00 in
Conflict #2 [20']
Ug. copper crossing proposed 18"Storm pipe. PH data shows
Lumen at 31" depth. Forte shows0-wkg. Suggest to abdn.
Ped 82-2size 6"1-term
Ped 72size 4" 1-term: Busted
Ug. Cable 1-4" CBO
300 PR Copper
TO PED 60SEE SHEET 7
tductductductductductductductductductduc10-wkg
tductductducUg. Cable 1-4" PVC
50 PR Copper
Ug. Cable 1-4" PVC50 PR Copper DEAD
TO C.O.TO P.100SEE SHT 7
4" PVC @ 31" DEPTH
TO C.O.TO MH's 202 & 11-1SEE SHEET 9
TO C.O.TO HH-94SEE SHEET 8
TO MH's 203 & 12SEE SHEET 10
1010
Possible ped replacement?XXXXXXXXDeactivate/abandon existing50pr [JX5]
Deactivate/abandon existing50pr [JX5]
During construction, removeexisting pedestal, cut andabandon 50pr
DUPLICATE OF PAGE 6