Loading...
HomeMy WebLinkAboutEX02_P_Floor_Plans_and_Architectural_Plans__CHC_Architects_240729_v1NO R T H PRESERVED WET LAND AREAWET LAND BUFFERING AREA FIRE DEPARTMENT VEHICULAR HAMMER HEAD PERMEABLE CONCRETE DRIVEWAY 10 FT SIDE YARD SET BACK PROPERTY LINE 589.83' S 00°29'24" W PROPERTY LINE 355.55' S 00°28'57" W PR O P E R T Y L I N E 1 2 6 . 5 3 ' S 8 9 ° 4 7 ' 0 5 " W PR O P E R T Y L I N E 1 0 0 . 4 7 ' N 8 9 ° 2 0 ' 3 5 " E PROPERTY LINE 234.00' S 00°29'24" W PER TOPOGRAPHIC SURVEY PR O P E R T Y L I N E 26 . 0 1 ' N 8 9 ° 2 0 ' 3 5 " E 10 FT SIDE YARD SET BACK 5 FT SIDE YARD SET BACK FOR ADU 27'-1178" 25 F T R E A R Y A R D S E T B A C K 94'-0" 33 ' - 0 " 52 ' - 0 " 20 ' - 0 " 20 ' - 6 " 3'- 0 " 20 ' - 0 " 12'-1034"26'-0" 36'-0" PROPOSED 1-STORY SINGLE FAMILY MAIN FLOOR EL. 261.0' GARAGE EL. 259.0' PROPOSED ADU MAIN FLOOR EL. 259.0' A B C D 15 14 13 12 11 10 9 6 5 1 2 3 23 21 20 18 17 4 PRIMARY ENTRANCE 6'- 0 " 36" EAVE, TYP. U.N.O 24" EAVE, TYP 28 27 26 25 24 8 19 16 SITE PLAN SCALE: 1" = 20'-0" A0 05-02-2024 PERMIT SET SITE PLAN LOT AREA 51,067 S.F. PARCEL NUMBER ZONING DISTRICT R-4 PROJECT INFORMATION PROPERTY OWNER LEONG YIN YIN 334390-3201 OCCUPANCY CLASSIFICATION R-3 / U CONSTRUCTION TYPE V-B 1. 2. SITE PLAN NOTES: ALL UTILITIES SERVING THE SITE IS TO BE UNDERGROUNDED. THE ADDRESS IS TO BE PLACED IN A POSITION THAT IS PLAINLY LEGIBLE ANDVISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. BLK'GCCLR CONT CS DBL DSELEQEXISTFTG FX HDRHDWD HORIZMAX MFR MINo/O.C.SDSGSFSIM SLD TYP UNO w/ ABBREVIATIONS BLOCKINGCENTER LINECLEAR CONTINUOUS CASEMENT WINDOW DOUBLE DOWNSPOUT ELEVATIONEQUALEXISTINGFOOTINGFIXED WINDOWHEADER HARDWOOD HORIZONTALMAXIMUMMANUFACTURERMINIMUMOVERON CENTER SMOKE DETECTOR SAFETY GLASS SQUARE FEET SIMILAR SLIDING WINDOWTYPICALUNLESS NOTED OTHERWISEWITH L HGR HANGER SEE CIVIL PLANS FOR STORM AND SANITARY SEWER CONNETIONS, AND ANY R-O-W WORKS LEGAL DESCRIPTION CODE COMPLIANCE 2021 INTERNATIONAL RESIDENTIAL CODE 2021 INTERNATIONAL FIRE CODE 2021 INTERNATIONAL MECHANICAL CODE 2021 UNIFORM PLUMBING CODE 2021 NATIONAL ELECTRICAL CODE2021 WASHINGTON STATE ENERGY CODE (ALL CODES ABOVE INCLUDE WASHINGTON STATEWIDE AMENDMENTS) 3,384 SFTOTAL FINISHED FLOOR AREA FLOOR AREA SUMMARIES MAIN FLOOR (MAIN RESIDENCE)3,384 SF GARAGE/ WORKSHOP 975 SF IMPERVIOUS SURFACE AREA 19,057 S.F. (37.3% --> OK!)TOTAL IMPERVIOUS SURFACE AREA CONC. DRIVEWAY 12,267 S.F. STRUCTURAL AREA 5,287 S.F. STRUCTURAL LOT COVERAGE BUILDING FOOTPRINT 4,549 S.F. ADU 738 S.F. MAX. LOT COVERAGE FOR STRUCTURE (35% OF LOT AREA) 5,287 S.F. (10.4% --> OK!)TOTAL STRUCTURAL AREA 17,873 S.F. MAX. IMPERVIOUS COVERAGE (40% OF LOT AREA)20,427 S.F. PORCH AND WALKWAY 398 S.F. 18 2 8 R E S I D E N C E 13301 SE 79TH PLACE UNIT A205 NEWCASTLE WA 98059(M) 425.785.3992 chcarch@gmail.com SHEET NUMBER JOB NUMBER SHEET TITLE DESCRIPTION OF REVISIONSDATENUMBER CITY STAMP NE W C O N S T R U C T I O N F O R 18 2 8 N E 2 0 T H S T R E E T R E N T O N W A 9 8 0 5 6 WEST & EAST CONC. PATIOS 297 S.F. EAVES OVER PERVIIOUS AREA 808 S.F. BUILDING HEIGHT MAX. BUILDING HEIGHT (30') PROPOSED BUILDING HEIGHT (SEE SHEET A4 & A5) 288.5' 280.75' (259.5 + 257.4 + 257.9 + 259.5) / 4 258.5' AVERAGE FINISHED GRADE ((A + B + C + D) / 4) LOT(S) 284 C.D. HILLMAN'S LAKE WASHINGTON GARDEN OF EDEN DIVISION NO. 4, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 11 OF PLATS, PAGE(S) 82, IN KING COUNTY, WASHINGTON; EXCEPT THE WEST 126 FEET THEREOF LYING NORTH OF THE SOUTH 234 FEET THEREOF; AND EXCEPT THE SOUTH 234 FEET THEREOF LYING WEST OF THE EAST26 FEET THEREOF. ADU 738 SF Docusign Envelope ID: 104DBDA6-11CD-4791-91FF-7DA2A96942C7 FOYER LIVING DINING KITCHEN PANTRY MUD PORCH GARAGE 3/0 PR. 3/0 2/8 3/0 2/8 PR . 3 / 0 16' x 8' GARAGE DOOR 2/ 8 BR 6 MAIN FLOOR 14'-0"9'-0"22'-0" 11'-3"31'-0" 29 ' - 0 " 3'- 0 " 10 ' - 6 " WORKSHOP 3/ 0 11 ' - 0 " 3'- 6 " 2/ 8 20'-0" 26'-0" 2/ 8 2/ 8 BR 1 2/8 2/8 BR 2 2/8 LAUNDRY 20'-0"9'-0" 2/ 8 2/8 2/8 2/8 2/ 8 BR 3 BR 4 BR 5 94'-0" 3'- 6 " 11 ' - 0 " 8'- 0 " 2' - 7 " 9'- 6 " 10 ' - 1 " 10 ' - 1 0 " 2/ 8 9'-9"6'-2"4'-1" D W 2/6 3'-10"19'-2" 12 ' - 0 " 30 ' - 0 " 3/ 0 PATIO 2'-9" 12 ' - 0 " 55 ' - 6 " D W S 10 0 C F M H O O D 24" D.W.S R S 3/0 HOSE BIBB HOSE BIBB HOSE BIBB BAY WINDOW PR. 2/6 PR. 2/6 PR. 2/6 PR . 2 / 6 PR . 2 / 6 6060 SLD EGRESS S 6060 SLD 6060 SLD3060 CS 60 5 0 S L D E G R E S S 60 5 0 S L D E G R E S S 60 5 0 S L D E G R E S S 60 5 0 S L D 3046 CS3050 CS 60 5 0 S L D E G R E S S 30 5 0 C S 60 5 0 S L D 6050 SLD EGRESS 6050 SLD6050 SLD 6030 FX o/ 6060 SLD6030 FX o/ 6060 SLD 6050 SLD 2050 CS 2/6 2/6 2080 FX S.G.2080 FX S.G. 9030 FX o/ 9060 SLD 3/0 PR . 2 / 6 24 x 48 SKYLIGHT ABOVE 3'-6" 2'-8"1'-912"12'-0"2'-0" 2'- 0 " 2'-6"9'-0"3'-6" 12 ' - 0 " 3'-0"9'-0"9'-0"8'-712" 2'-0" 9'-234"7'-0"2'-1114" 3'-1112" 2' - 7 34" 2'- 0 12" 1'- 9 " 2'- 6 " 2' - 5 " 6'- 0 " 1'- 6 " 2'-312" 8'-0" 2'-312" 4'- 0 " 3'- 0 " 5'-1"10'-0"4'-0"9'-0" 2'- 2 " 6'- 1 1 12" 6'- 0 12" 6'- 3 " 7'-3" 6'- 9 " 11'-012" 6'- 1 1 12" 2'-312" 6'-512"2'-912" 4'- 0 " 6' - 7 " 3'- 8 " 7'- 0 12" 4' - 0 " 2'- 3 12" 2'- 3 12" 3' - 1 1 " 6'- 9 " 6'-7"7'-412" 1'-214" 6'-412" 6'- 9 12" 8'-612" 4'- 9 12" 6'-9"1'-0" CARBON MONOXIDEALARM 110V S.D. 110V S.D. 110VS.D. 110V S.D. 110V S.D.110V S.D. 110V S.D. 110V S.D. 110V S.D. 110VS.D. 110V S.D. 110VS.D. CARBON MONOXIDE ALARM CARBONMONOXIDEALARM CARBONMONOXIDEALARM 50 CFM 50 CFM 50 CFM 50 CFM 50 CFM 50 CFM 50 CFM MIN. 90 CFM CONT.WHOLE HOUSE FAN W/FLOW RATING AT 0.25"WATER GAUGE PER 2018 IRC TABLE M1507.3.3(1)., & SONE RATING OF 1.0 OR LESS MEASURED AT 0.1" WATER GAUGE PER IRC M1507.3.4.GARAGE SEPARATION REQUIRES ½"GYPSUM WALL BOARD ON THE GARAGESIDE. 5/8" TYPE "X" GYPSUM WALL BOARDIS REQUIRED WHERE THERE IS LIVING SPACE ABOVE. SUPPORTING COLUMNS, WALLS AND BEAMS USE ½" GYPSUM WALL BOARD IRC SECTION R302.6 SL O P E T O D O O R H.D. A HEAT DETECTOR OR HEAT ALARM RATED FORTHE AMBIENT OUTDOOR TEMPERATURES ANDHUMIDITY. HEAT DETECTORS AND HEATALARAMS SHALL BE INSTALLED IN A CENTRALLOCATION AND IN ACCORDANCE WITH THEMANUFACTURER'S INSTRUCTIONS (IRC R314.2.3). 20 MIN. FIRE RATED EQUIPPEDw/ A SELF-CLOSING DEVICE 20 MIN. FIRE RATED EQUIPPEDw/ A SELF-CLOSING DEVICE DUCTLESS HEAT PUMP SYSTEM w/ A MIN. HSPF OF 10 ELECTRIC HEAT PUMP WATERHEATER w/ A MIN. UEF OF 2.9 2'-1012" KITCHEN RANGE HOODS CAPABLE OFEXHAUSTING MORE THAN 400 CFM REQUIREMAKE UP AIR PER IRC M1503.4 50 CFM 2'-312" CRAWL ACCESS OPENINGS THROUGH THE FLOOR SHALL BE AMINIMUM OF 18" X 24" PER IBC SECTION 1209.1 & IRC SECTION 408.4. AND SHALL BE INSULATED TO MINIMUM R-30 AND WEATHERSTRIPPED 11 ' - 0 " MIN. 22x30 ATTIC ACCESS w/ MIN. HEADROOM OF 30" & w/ R-49 INSULATION & WEATHER-STRIPPED 6/0 SLD DOOR MAIN FLOOR PLAN SCALE: 1/4" = 1'-0"A1 MAIN FLOOR PLAN 1. 2. 3. 4. 5. 6. 7. 8. PLAN NOTES: USE CONVENTIONAL FRAMING AND SHEATHING U.N.O. ALL EXTERIOR WALLS TO BE 2x6 FRAMING U.N.O. ALL INTERIOR WALLS TO BE 2x4 FRAMING U.N.O. ALL DOOR JAMBS TO BE SET OFF WALLS 6" TYP. U.N.O. ALL DIMENSIONS ARE TO FACE OF FRAMING U.N.O. ALL WINDOW HEADS TO BE 6'-8" TO FINISH FLOOR AT THIS FLOOR, U.N.O. ALL EXHAUST FANS ARE TO VENTED TO OUTSIDE. DOOR HT. AT THIS FLOOR IS 6'-8", TYP. U.N.O. ALL SMOKE DETECTORS MUST BE PROVIDED w/ PRIMARY POWER FROM BUILDING WIRING, PROVIDED w/ BATTERY BACKUP, AND BE INTERCONNECTED. ESCAPE (EGRESS) WINDOW MUST HAVE A CLEAR OPENABLE AREA OF 5.7 S.F. w/ A MINIMUM NET CLEAR HEIGHT OF 24" AND WIDTH DIMENSION OF 20". THE SILL HEIGHT MUST NOT BE MORE THAN 44" ABOVE THE FLOOR. ALL EXTERIOR COLUMNS, BEAMS, AND JOISTS THAT ARE EXPOSED TO THEWEATHER MUST BE PRESSURE-TREATED. 9. 10. 11. PERMIT SET 18 2 8 R E S I D E N C E 13301 SE 79TH PLACE UNIT A205 NEWCASTLE WA 98059(M) 425.785.3992 chcarch@gmail.com SHEET NUMBER JOB NUMBER SHEET TITLE DESCRIPTION OF REVISIONSDATENUMBER CITY STAMP NE W C O N S T R U C T I O N F O R 18 2 8 N E 2 0 T H S T R E E T R E N T O N W A 9 8 0 5 6 05-02-2024 Docusign Envelope ID: 104DBDA6-11CD-4791-91FF-7DA2A96942C7 ROOF PITCH 4:12 TYP. U.N.O. 2( 21 ) 8"∅ ROOF VENTS (50 IN VENT AREA) ROOF VENTILATION ATTIC AREA = 4370 S.F. REQUIRED VENTILATION = 4370 / 300 = 14.56 S.F. (2097 IN )2 EAVE VENT: MIN. 50% = 1049 IN PROPOSED EAVE VENT ((3) ∅1-3/4" HOLES ON EA. EAVEBLOCKING): 3.6 IN / L.F. x 329' = 1185 IN (SEE SHEET A6 FOR EAVE BLOCKING) # OF ROOF VENTS: 1049 IN / 8"∅ (50 IN ) = 21 2 22 22 D.S. D.S. D.S. D.S. D.S. D.S.D.S. D.S. D.S. D.S. D.S. D.S.D.S. SKYLIGHT (10) EXHAUST OPENINGS 3'-0" 3' - 0 " ROOF PLAN SCALE: 1/4" = 1'-0" A2 ROOF PLANPER WSEC R402.4, THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE.THE RESULTS OF THE TEST SHALL BE SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED TOTHE CODE OFFICIAL (R402.4.1.2). PER WSEC R403.2.2, DUCTS, AIR HANDLERS, AND FILTER BOXES SHALL BE SEALED. PER WSEC R404.1, A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS. AIR LEAKAGE SHALL NOT EXCEED 5 AIR CHANGES/ HOUR AND SHALL BE TESTED AS SUCH. A WRITTEN REPORT OF THE TEST RESULTS, SHALL BE SIGNED BY THE TESTING PARTY AND PROVIDED TO THEBUILDING INSPECTOR, PRIOR TO CALL FOR FINAL INSPECTION.” THE AIR LEAKAGE TEST RESULT SHALL BEDOCUMENTED ON THE FORM WHICH IS AVAILABLE ONLINE ATHTTP://WWW.ENERGY.WSU.EDU/BUILDINGEFFICIENCY/ENERGYCODE.ASPX THE DESIGN PROFESSIONAL OR BUILDER SHALL COMPLETE AND POST AN "INSULATION CERTIFICATE FOR RESIDENTIAL CONSTRUCTION" WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION. A SINGLE BLANK FORM SHOULD BE INCLUDED ON THE PLAN DRAWINGS. THESE ARE AVAILABLE ONLINE AT HTTP://WWW.ENERGY.WSU.EDU/DOCUMENTS/WSEC-2015-AVERY-6878_4_PER_SHEET.PDF WINDOW AND DOOR HEADERS SHALL BE INSULATED WITH A MINIMUM OF R-10 INSULATION. ALL NEW FENESTRATION ARE NFRC CERTIFIED. ALL EXHAUST SHALL TERMINATE OUTSIDE NOT LESS THAN 3 FEET FROM PROPERTY LINES; 3 FEET FROMOPERABLE/ NON-OPERABLE OPENINGS INTO BUILDINGS AND 10 FEET FROM MECHANICAL AIR INTAKES, EXCEPT WHERE OPENING IS 3 FEET ABOVE AIR INTAKE, PER SRC M1506.3 ENERGY NOTES: PERMIT SET 18 2 8 R E S I D E N C E 13301 SE 79TH PLACE UNIT A205 NEWCASTLE WA 98059(M) 425.785.3992 chcarch@gmail.com SHEET NUMBER JOB NUMBER SHEET TITLE DESCRIPTION OF REVISIONSDATENUMBER CITY STAMP NE W C O N S T R U C T I O N F O R 18 2 8 N E 2 0 T H S T R E E T R E N T O N W A 9 8 0 5 6 05-02-2024 Docusign Envelope ID: 104DBDA6-11CD-4791-91FF-7DA2A96942C7 CRAWL SPACE ACCESS.SEE FLOOR PLAN (43) CRAWL SPACE VENT, TYP.5'- 0 " T Y P . CRAWL SPACE = 3721 S.F. --> 3721 / 150 = 24.80 --> 24.80 / 0 .58 = 43 VENTS REQUIRED TYPICAL SCREENED 14"x 8" C.S. VENT - MIN. w/ .58 SQ. FT.OF NET FREE AREA EACH NOTE: LOCATE VENTS BETWEEN JOISTS AND AVOID CONFLICT W/ HOLDOWNS CRAWL SPACE VENTILATION SLAB ON GRADE SLAB ON GRADE CRAWL SPACE A3 CRAWL SPACE PLAN PERMIT SET 18 2 8 R E S I D E N C E 13301 SE 79TH PLACE UNIT A205 NEWCASTLE WA 98059(M) 425.785.3992 chcarch@gmail.com SHEET NUMBER JOB NUMBER SHEET TITLE DESCRIPTION OF REVISIONSDATENUMBER CITY STAMP NE W C O N S T R U C T I O N F O R 18 2 8 N E 2 0 T H S T R E E T R E N T O N W A 9 8 0 5 6 CRAWL SPACE PLAN SCALE: 1/8" = 1'=0" 05-02-2024 Docusign Envelope ID: 104DBDA6-11CD-4791-91FF-7DA2A96942C7 10 ' - 0 " MAIN PLT. MAIN FLOOR EL. 261' LIVING PLT. 14 ' - 8 " 50-YR COMPOSITION ROOF TILES T & G CEDAR SIDING FIBER-CEMENT LAP SIDINGw/ 6" EXPOSURE 3" BELLY TRIM 8" & 2" BOTTOM TRIM 4" TRIM 4" CORNER TRIM FIBER-CEMENT PANELSw/ 1x TRIMS @ 36" O.C. 4 12 AVERAGE FINISHED GRADE EL. 258.5' BUILDING HT. LIMIT EL. 288.5' 30 ' - 0 " PROPOSED BUILDING HT. (MID PT. OF ROOF) EL. 280.75' 22 ' - 2 " 10 ' - 0 " MAIN PLT. MAIN FLOOR EL. 260.5' 10 ' - 0 " MAIN PLT. MAIN FLOOR EL. 261.0' LIVING PLT. 14 ' - 8 " 50-YR COMPOSITION ROOF TILES STONE VENEER FIBER-CEMENT PANELSw/ 1x TRIMS @ 36" O.C. FIBER-CEMENT LAP SIDINGw/ 6" EXPOSURE 4" CORNER TRIM 4 12 3" BELLY TRIM 8" & 2" BOTTOM TRIM 4" TRIMAVERAGE FINISHED GRADE EL. 258.5' BUILDING HT. LIMIT EL. 288.5' 30 ' - 0 " PROPOSED BUILDING HT. (MID PT. OF ROOF) EL. 280.75' 22 ' - 2 " EAST ELEVATION SCALE: 1/4" = 1'-0" A4 BUILDING ELEVATIONS PERMIT SET 18 2 8 R E S I D E N C E 13301 SE 79TH PLACE UNIT A205 NEWCASTLE WA 98059(M) 425.785.3992 chcarch@gmail.com SHEET NUMBER JOB NUMBER SHEET TITLE DESCRIPTION OF REVISIONSDATENUMBER CITY STAMP NE W C O N S T R U C T I O N F O R 18 2 8 N E 2 0 T H S T R E E T R E N T O N W A 9 8 0 5 6 SOUTH ELEVATION SCALE: 1/4" = 1'-0" 05-02-2024 Docusign Envelope ID: 104DBDA6-11CD-4791-91FF-7DA2A96942C7 10 ' - 0 " MAIN PLT. MAIN FLOOR EL. 261.0' LIVING PLT. 14 ' - 8 " 50-YR COMPOSITION ROOF TILES FIBER-CEMENT PANELS w/ 1x TRIMS @ 36" O.C. FIBER-CEMENT LAP SIDING w/ 6" EXPOSURE 4" CORNER TRIM 4 12 AVERAGE FINISHED GRADE EL. 258.5' BUILDING HT. LIMIT EL. 288.5' 30 ' - 0 " PROPOSED BUILDING HT. (MID PT. OF ROOF) EL. 280.75' 22 ' - 2 " 10 ' - 0 " MAIN PLT. MAIN FLOOR EL. 260.5' LIVING PLT. 14 ' - 8 " 50-YR COMPOSITION ROOF TILES STONE VENEER FIBER-CEMENT PANELS w/ 1x TRIMS @ 36" O.C. FIBER-CEMENT LAP SIDINGw/ 6" EXPOSURE 4" CORNER TRIM 4 12 AVERAGE FINISHED GRADE EL. 258.5' BUILDING HT. LIMIT EL. 288.5' 30 ' - 0 " PROPOSED BUILDING HT. (MID PT. OF ROOF) EL. 280.75' 22 ' - 2 " WEST ELEVATION SCALE: 1/4" = 1'-0" A5 BUILDING ELEVATIONS PERMIT SET 18 2 8 R E S I D E N C E 13301 SE 79TH PLACE UNIT A205NEWCASTLE WA 98059(M) 425.785.3992 chcarch@gmail.com SHEET NUMBER JOB NUMBER SHEET TITLE DESCRIPTION OF REVISIONSDATENUMBER CITY STAMP NE W C O N S T R U C T I O N F O R 18 2 8 N E 2 0 T H S T R E E T R E N T O N W A 9 8 0 5 6 NORTH ELEVATION SCALE: 1/4" = 1'-0" FIREBLOCKING SHALL BE PROVIDED IN WOOD-FRAME CONSTRUCTION IN THE FOLLOWING LOCATIONS: 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES ANDPARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS: 1.1. VERTICALLY AT THE CEILING AND FLOOR LEVELS. 1.2. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET (3048 MM). 2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN.ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH SECTION R302.7. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTSOF COMBUSTION. THE MATERIAL FILLING THIS ANNULAR SPACE SHALL NOT BE REQUIRED TO MEET THE ASTM E 136 REQUIREMENTS. 05-02-2024 Docusign Envelope ID: 104DBDA6-11CD-4791-91FF-7DA2A96942C7 10 ' - 0 " MAIN PLT. MAIN FLOOR EL. 260.5' LIVING PLT. 14 ' - 8 " FOYER LIVINGPORCH R-49 INSULATION ATTIC R-21 INSULATION R-10 RIGID INSULATION AT HEADER WHEN APPLICABLE R-21 INSULATION CRAWL SPACE 6 MIL VAPOR BARRIER R-38 INSULATION 4 12 AVERAGE FINISHED GRADE EL. 258.5' BUILDING HT. LIMIT EL. 288.5' 30 ' - 0 " 22 ' - 2 " PROPOSED BUILDING HT. (MID PT. OF ROOF) EL. 280.75' 10 ' - 0 " MAIN FLOOR CEILING CARPET, HARDWOOD, OR TILE FINISH FLOOR ON T&G PLYWOOD SUBFLOOR ON FLOOR JOISTS @ 16" O.C. U.N.O. (SEE FRAMING PLANS)R-38 INSULATION MI N . 6 " FINISH GRADE 6 MIL VAPOR BARRIER MI N . 1 8 " MI N . 6 " SEE STRUCT. SHEET FOR FTG. DETAIL 4" EXTERIOR PERF. DRAIN TIEDTO STORM LINE 3/4" WASHED ROCKS FILTER FABRIC P.T. SILL PLATE HEADER PER STRUCTURAL 2x6 TOP PLATE WINDOWS W/ MAX.U-VALUE = .28 FIBER-CEMENT PANEL OR LAP SIDING ON 2 LAYERS OF GRADE 'D' BUILDING PAPER OR 1 LAYER OF NO 15 ASPHALT FELT ONPLYWOOD WALL SHEATHING ON 2x6 STUDS @ 16" O.C. AT EXTERIOR WALLS (2x4 STUDS @ 16" O.C.AT INTERIOR WALLS) U.N.O. R-21 INSULATION 1/2" G.W.B. 5" GUTTER 36" ROOF CONSTRUCTION: PROVIDE (3) Ø1 3/4" OPENINGS AT EA. BLOCK FOR VENTILATION 12 4 1x6 FACIA BD. 1" MIN. CLEAR VENTED AIR SPACE ABOVE THE INSULATION 50-YR COMPOSITION ROOFING ON30# FELT ON PLYWOOD ROOF SHEATHING ON2x RAFTER OR TRUSS TOP CHORDS @ 24" O.C.R-49 INSULATION W/ VAPOR BARRIER 2x CEILING JOISTS OR TRUSS BOTTOM CHORDS @ 24" O.C. (U.N.O.)5/8" G.W.B. (5/8" TYPE 'X' @ GARAGE WHERE NOTED) 1x6 PINE T&G SOFFIT w/ CONT. VENT CONT. RIGID BAFFLE/PANEL TO MAINTAIN VENTILATION24" MIN. 10 ' - 0 " MAIN PLT. MAIN FLOOR EL. 260.5' LIVING PLT. 14 ' - 8 " LIVING CRAWL SPACE 6 MIL VAPOR BARRIER R-38 INSULATION R-49 INSULATION ATTIC R-21 INSULATION R-21 INSULATION R-21 INSULATION R-49 INSULATION R-49 INSULATION GARAGEPANTRYBR 3 AVERAGE FINISHED GRADE EL. 258.5' BUILDING HT. LIMIT EL. 288.5' 30 ' - 0 " 22 ' - 2 " PROPOSED BUILDING HT. (MID PT. OF ROOF) EL. 280.75' 18 2 8 R E S I D E N C E 13301 SE 79TH PLACE UNIT A205 NEWCASTLE WA 98059(M) 425.785.3992 chcarch@gmail.com SHEET NUMBER JOB NUMBER SHEET TITLE DESCRIPTION OF REVISIONSDATENUMBER CITY STAMP NE W C O N S T R U C T I O N F O R 18 2 8 N E 2 0 T H S T R E E T R E N T O N W A 9 8 0 5 6 BUILDING SECTION B-B SCALE: 1/4" = 1'-0" TYP. WALL SECTION SCALE: 1/2" = 1'-0" BUILDING SECTION A-A SCALE: 1/4" = 1'-0" A6 SECTIONS AND DETAILS 05-02-2024 PERMIT SET Docusign Envelope ID: 104DBDA6-11CD-4791-91FF-7DA2A96942C7 2/ 6 2/ 6 2/ 6 2/6 W / D 3/0 11'-2"2'-7"6'-9"15'-6" 20 ' - 6 " 15'-6"6'-9"2'-7"11'-2" 10 ' - 0 " 10 ' - 6 " 2/ 6 R 36'-0" PR . 2 / 6 PR . 2 / 6 60 5 0 S L D E G R E S S 60 5 0 S L D E G R E S S 30 5 0 S L D 2646 CS 6050 SLD2050 CS BR 1 BR 2 BATH 2 BATH 1 LIVING KITCHEN / DINING 2050 CS HOSE BIBB 2050 CS 2050 CS CARBONMONOXIDEALARM 50 CFM 50 CFM MIN. 90 CFM CONT. WHOLE HOUSE FAN W/ FLOW RATING AT 0.25"WATER GAUGE PER 2018IRC TABLE M1507.3.3(1)., &SONE RATING OF 1.0 ORLESS MEASURED AT 0.1"WATER GAUGE PER IRCM1507.3.4. 110V S.D. 110V S.D. 110VS.D. KITCHEN RANGE HOODS CAPABLE OFEXHAUSTING MORE THAN 400 CFMREQUIRE MAKE UP AIR PER IRC M1503.4 8'-8"6"4'-614" 2'- 2 34" 2' - 2 " 8'-8"7'-512" 3' - 9 " 6'- 3 12" 3'- 3 " 2'-0" 6'- 3 12" 2' - 9 12" 4'-7" 3' - 5 12" 3'-7" ELECTRIC HEAT PUMP WATERHEATER w/ A MIN. UEF OF 2.9 3'-1112" CRAWL ACCESS OPENINGS THROUGH THE FLOORSHALL BE A MINIMUM OF 18" X 24" PER IBC SECTION1209.1 & IRC SECTION 408.4. AND SHALL BE INSULATEDTO MINIMUM R-30 AND WEATHERSTRIPPED MIN. 22x30 ATTIC ACCESS w/ MIN.HEADROOM OF 30" & w/ R-49 INSULATION & WEATHER-STRIPPED 30 5 0 S L D 5'-0" 8" 8" 4' - 0 " 6" 6" 3'- 9 " CL ROOF VENTILATION ATTIC AREA = 738 S.F. REQUIRED VENTILATION = 738 / 300 = 2.46 S.F. (355 IN )2 EAVE VENT: MIN. 50% = 178 IN PROPOSED EAVE VENT ((3) ∅1-3/4" HOLES ON EA. EAVEBLOCKING): 3.6 IN / L.F. x 113' = 407 IN (SEE SHEET A6FOR EAVE BLOCKING) # OF ROOF VENTS: 407 IN / 8"∅ (50 IN ) = 9 2 22 22 2( 9 ) 8"∅ ROOF VENTS (50 IN VENT AREA) D.S. D.S. D.S. D.S. 2'-0" 2'- 0 " 9'- 6 " ADU PLT. ADU FLOOR EL. 259.0' 50-YR COMPOSITION ROOF TILES FIBER-CEMENT LAP SIDINGw/ 6" EXPOSURE 4 12 9' - 6 " ADU PLT. ADU FLOOR EL. 259.0' 50-YR COMPOSITION ROOF TILES 4" CORNER TRIM FIBER-CEMENT LAP SIDING w/ 6" EXPOSURE 9'- 6 " ADU PLT. ADU FLOOR EL. 259.0' 50-YR COMPOSITION ROOF TILES 4" CORNER TRIM FIBER-CEMENT LAP SIDING w/ 6" EXPOSURE 4 12 9'- 6 " ADU PLT. ADU FLOOR EL. 259.0' 50-YR COMPOSITION ROOF TILES FIBER-CEMENT LAP SIDINGw/ 6" EXPOSURE 4" CORNER TRIM R-21 INSULATION 9'- 6 " ADU PLT. ADU FLOOR EL. 259.0' R-49 INSULATION ATTIC CRAWL SPACE 6 MIL VAPOR BARRIER R-38 INSULATION BR 1 LIVING R-10 RIGID INSULATION AT HEADER WHEN APPLICABLE CRAWL SPACE VENTILATION CRAWL SPACE = 665 S.F. --> 665 / 150 = 4.43 --> 4.43 / 0 .58 = 8 VENTS REQUIRED TYPICAL SCREENED 14"x 8" C.S. VENT - MIN. w/ .58 SQ. FT.OF NET FREE AREA EACH NOTE: LOCATE VENTS BETWEEN JOISTS AND AVOID CONFLICT W/ HOLDOWNS CRAWL SPACE ACCESS.SEE FLOOR PLAN (8) CRAWL SPACE VENT, TYP. 10 ' - 0 " T Y P . A7 ADU PERMIT SET 18 2 8 R E S I D E N C E 13301 SE 79TH PLACE UNIT A205 NEWCASTLE WA 98059(M) 425.785.3992 chcarch@gmail.com SHEET NUMBER JOB NUMBER SHEET TITLE DESCRIPTION OF REVISIONSDATENUMBER CITY STAMP NE W C O N S T R U C T I O N F O R 18 2 8 N E 2 0 T H S T R E E T R E N T O N W A 9 8 0 5 6 ADU PLAN SCALE: 1/4" = 1'-0" ADU ROOF PLAN SCALE: 1/4" = 1'-0" ADU SOUTH ELEVATION SCALE: 1/4" = 1'-0" ADU EAST ELEVATION SCALE: 1/4" = 1'-0" ADU NORTH ELEVATION SCALE: 1/4" = 1'-0" ADU WEST ELEVATION SCALE: 1/4" = 1'-0" BUILDING SECTION C-C SCALE: 1/4" = 1'-0" ADU CRAWL SPACE PLAN SCALE: 1/8" = 1'=0" 05-02-2024 Docusign Envelope ID: 104DBDA6-11CD-4791-91FF-7DA2A96942C7 18 2 8 R E S I D E N C E 13301 SE 79TH PLACE UNIT A205 NEWCASTLE WA 98059(M) 425.785.3992 chcarch@gmail.com SHEET NUMBER JOB NUMBER SHEET TITLE DESCRIPTION OF REVISIONSDATENUMBER CITY STAMP NE W C O N S T R U C T I O N F O R 18 2 8 N E 2 0 T H S T R E E T R E N T O N W A 9 8 0 5 6 A8 ENERGY FORMS PERMIT SET05-02-2024 Docusign Envelope ID: 104DBDA6-11CD-4791-91FF-7DA2A96942C7 18 2 8 R E S I D E N C E 13301 SE 79TH PLACE UNIT A205 NEWCASTLE WA 98059(M) 425.785.3992 chcarch@gmail.com SHEET NUMBER JOB NUMBER SHEET TITLE DESCRIPTION OF REVISIONSDATENUMBER CITY STAMP NE W C O N S T R U C T I O N F O R 18 2 8 N E 2 0 T H S T R E E T R E N T O N W A 9 8 0 5 6 A9 ADU - ENERGY FORMS PERMIT SET05-02-2024 Docusign Envelope ID: 104DBDA6-11CD-4791-91FF-7DA2A96942C7 Docusign Envelope ID: 104DBDA6-11CD-4791-91FF-7DA2A96942C7