Loading...
HomeMy WebLinkAbout4-KCWD00902023-Maple Highlands Chambers Plat DE-Final Plans-signedSE 2ND CT SE 2ND ST SE 2ND PL SE 3RD PL SE 138TH PL SE 6TH PL SE 7TH PL SE 142ND ST SE 141ST PL SE 140TH PL SE 139TH PL SE 138TH PL SE 143RD ST SE 2ND LN 156TH AVE SESHADOW PLACE SETOLEDO AVE SEROSARIOPL SE152ND AVE SE154TH AVE SE150TH PL SE149TH PL SE148TH PL SE148THPL SESE 142N D P L SE 142N D P L SE 4TH PL SE 5TH PLROSARIOAVE SEMAPLEWOOD PARK WAPATO PL SESE 143RD PLSE139THCT 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 4 SK/MWGBRI/JT SE 5TH PL REVISIONS REDUCED SEPARATION DUE TO RETAINING WALL 7/19/2024 7/19/2024 FOR CONSTRUCTION 2221005.10 12600 SE 38TH STREET BELLEVUE, WA 98006 CONTACT: DALTON SMITH PHONE: (888)302-1252 CONNER HOMES MAPLE HIGHLANDS SW 1/4, SEC 14, TWN 23, RGE 5, CITY OF RENTON MAPLE HIGHLANDS - KING COUNTY WATER DISTRICT 90 BASIS OF BEARING WASHINGTON STATE PLAN COORDINATE SYSTEM, NAD 83/91 NORTH ZONE 4601 PER CITY OF RENTON COORDINATE SYSTEM. VERTICAL DATUM NAVD 88 - CONTRACTOR TO VERIFY ELEVATIONS TO LOCAL SITE CONTROL PRIOR TO CONSTRUCTION. LEGAL DESCRIPTION PARCEL: 146340-0020 CEDAR RIVER FIVE ACRE TRS PP ACT 39923602 MOBILE HOME S 1/2 OF E 1/2 PARCEL: 146340-0021 CEDAR RIVER FIVE ACRE TRS S 110 FT OF W 1/2 OF LOT 3 TGW N 1/2 OF LOT 4 - AKA LOT B OF KC LOT LINE ADJ NO 8908008 APPROVED NOVEMBER 30, 1989 EXISTING PROPOSED TRENCH NOTE IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF WSDOT SECTION 2-09.3(3)B, IT SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR WORKER SAFETY AND AHBL ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTEMS SHALL MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, CHAPTER 49.17 RCW. UTILITY NOTE THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. AHBL ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. SITE INFORMATION JURISDICTION:CITY OF RENTON PARCEL NUMBERS:1463400020 1463400021 GROSS SITE AREA:181,167 SF (4.16 AC) PUBLIC ROW:42,064 SF (0.97 AC) NET SITE AREA:139,103 (3.19 AC) EXISTING ZONING:R-4 (4 DU/AC) ALLOWED LOTS:12 LOTS (3.19 AC X 4 DU/AC =12.8) MAX NET DENSITY:4 DU/AC DENSITY PROPOSED:3.8 DU/AC DESIGN STANDARDS MIN LOT AREA:9,000 SF MIN LOT WIDTH:70' MIN WIDTH CORNER LOT:80' MIN LOT DEPTH:100' FRONT SETBACK:30' STREET SETBACK:30' SIDE YARD SETBACK:20' COMBINED 7.5' MIN REAR YARD SETBACK:25' REAR IF CORNER LOT:REAR CAN BE SIDE SETBACK IF CORNER LOT MAX IMPERVIOUS:50% MAX LOT COVERAGE:35% LEGEND GENERAL NOTES 1.ALL CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF KING COUNTY WATER DISTRICT NO. 90, THE DISTRICT'S TECHNICAL STANDARDS AND STANDARD DETAILS, THE LOCAL ROADWAY AGENCY AND THESE DRAWINGS. 2.THE LOCATION OF THE EXISTING UTILITIES SHOWN ON THE DRAWING IS APPROXIMATE. LOCATION AND PROTECTION OF UNDERGROUND UTILITIES SHALL BE IN ACCORDANCE WITH CHAPTER 19.122 RCW. CALL 800-424-5555 AT LEAST TWO BUSINESS DAYS BEFORE ANY EXCAVATION. 3.REPLACE ANY DAMAGED OR DESTROYED SURVEY MONUMENTS. 4.THIS PLAN AND PROFILE INFORMATION HAS BEEN FURNISHED BY THE DEVELOPER OF HIS ENGINEER. 5.MINIMUM SEPARATION BETWEEN SANITARY SEWERS AND POTABLE WATER LINES SHALL BE 10 FEET HORIZONTALLY (MEASURED SIDE TO SIDE) AND 18 INCHES VERTICALLY FROM BOTTOM OF WATER LINE TO CROWN OF SEWER. MINIMUM VERTICAL SEPARATION FOR PERPENDICULAR OF OBLIQUE CROSSINGS SHALL BE 3 FEET FROM OUTSIDE EDGES. SITUATIONS THAT REQUIRE LESS THAN MINIMUM SEPARATION SHALL BE CONSTRUCTED IN ACCORDANCE WITH DOE'S "CRITERIA FOR SEWAGE WORKS DESIGN", LATEST EDITION. 6.THE DEVELOPER SHALL BE RESPONSIBLE FOR ACQUIRING ALL NECESSARY EASEMENT, AGREEMENTS AND PERMITS PRIOR TO CONSTRUCTION. 7.A PRE-CONSTRUCTION CONFERENCE IS REQUIRED. CALL KCWD 90 AT (425) 255-9600 TO SCHEDULE PRIOR TO PERFORMING ANY WORK. 8.THE CONTRACTOR SHALL NOTIFY THE DISTRICT AT LEAST SEVEN (7) DAYS IN ADVANCE AND MAKE THE NECESSARY ARRANGEMENTS WITH THE DISTRICT INSPECTOR BEFORE CONNECTING TO THE EXISTING WATER SYSTEM. 9.WATER SHUTOFFS REQUIRE A MINIMUM OF 72 HOURS PRIOR NOTIFICATION TO AFFECTED CONNECTION. 10.CONTRACTOR IS REQUIRED TO PROVIDE A COMPETENT PERSON(S) TRAINED TO IDENTIFY EXISTING OR PREDICTABLE HAZARDS RELATED TO TRENCH SAFETY, SOIL CONDITIONS AND SHORING REQUIREMENTS, IN ACCORDANCE WITH WAC 296-155. CAUTION - EXTREME HAZARD - OVERHEAD ELECTRICAL SERVICE LINES ARE GENERALLY NOT SHOWN ON THE DRAWINGS. ELECTRICAL LINES SHOWN ON THE DRAWINGS ARE LOCATED BY POINT-TO-POINT, POWER-POLE-TO-POWER-POLE CONNECTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE EXTENT OF ANY HAZARD CREATED BY OVERHEAD ELECTRICAL POWER IN ALL AREAS AND SHALL FOLLOW PROCEDURES DURING CONSTRUCTION, THE CONTRACTOR SHALL MEET WITH UTILITY OWNERS AND DETERMINE THE EXTENT OF HAZARD AND REMEDIAL MEASURES, AND SHALL TAKE WHATEVER PRECAUTIONS MAY BE REQUIRED. DISTRICT STANDARD DETAILS ALL KING COUNTY WATER DISTRICT NO. 90 STANDARD DETAIL ARE APPLICABLE TO THIS PROJECT AND CAN BE FOUND ON THE DISTRICT'S WEBSITE. ANY DISTRICT STANDARD DETAIL SHOWN ON THESE PLANS HAS BEEN MODIFIED FOR THIS PROJECT SPECIFICALLY. DATE: July 11, 2024 FILENAME: Q:\2022\2221005\10_CIV\CAD\_Water\2221005-SH-COVR.dwg C0.1 1 COVER SHEET UTILITY CONTACTS STORM/SEWER:CITY OF RENTON 1055 SOUTH GRADY WAY, RENTON, WA 98057 PH: (425) 430 7339 WATER:KING COUNTY WATER DISTRICT NO. 90 15606 SE 128TH ST, RENTON, WA 98059 PH: (425) 255-9600 VICINITY MAP SCALE: 1"=500' SITE N OWNER CONNER HOMES 12600 SE 38TH STREET BELLEVUE, WA 98006 PH: (888) 302-1252 CONTACT: DALTON SMITH SURVEYOR KPFF CONSULTING ENGINEERS 612 WOODLAND SQUARE LOOP SE, SUITE 100 LACEY, WA 98503 PH: (360) 292-7230 CONTACT: JEREME CHAPMAN, PLS CIVIL ENGINEER AHBL 2215 NORTH 30TH STREET, SUITE 300 TACOMA, WA 98403 PH. (253) 383-2422 FAX (253) 383-2572 CONTACT: SCOTT KAUL, PE GEOTECH THE RILEY GROUP, INC. 17522 BOTHELL WAY NE BOTHELL, WA 98011 PH: (425) 415-0551 CONTACT: KRISTINA WELLER, PE PARCEL # 1463400020 1463400021 SITE ADDRESS 13929 154TH AVE SE RENTON, WA 98059 13818 152ND AVE SE RENTON, WA 98059 SHEET INDEX Sheet Number Sheet Title C0.1 COVER SHEET C0.2 EXISTING CONDITIONS C1.0 WATER PLAN C1.1 WATER PROFILES AND DETAILS RD S W DD W S RD 07/19/2024 S88° 18' 04"E 297.10' S0° 32' 11"W 110.02' S88° 18' 04"E 297.13' S0° 31' 04"W 166.35'0.1'5.1'14'4'FND IRON PIPE SHED(TYP.) PROP LINE 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 4 SK/MWGBRI/JT SE 5TH PL REVISIONS REDUCED SEPARATION DUE TO RETAINING WALL 7/19/2024 7/19/2024 FOR CONSTRUCTION 2221005.10 12600 SE 38TH STREET BELLEVUE, WA 98006 CONTACT: DALTON SMITH PHONE: (888)302-1252 CONNER HOMES MAPLE HIGHLANDS SW 1/4, SEC 14, TWN 23, RGE 5, CITY OF RENTON MAPLE HIGHLANDS - KING COUNTY WATER DISTRICT 90 DATE: March 19, 2024 FILENAME: Q:\2022\2221005\10_CIV\CAD\_Water\2221005-SH-EXST-COND.dwg C0.2 2 EXISTING CONDITIONS N GRAPHIC SCALE 0 40 80 1" = 40 FEET 20 07/19/2024 0.1'5.1'14'4'FND IRON PIPE SHED(TYP.) PROP LINE386386386386386 384386 388390392390388 392 390 384 38 6 388 392 394 38 6 386380378 382 384 380374376378382384374376376382 388 386 386 378152ND AVE SE153RD AVE SE154TH AVE SESE 5TH PL 1234 5 6 7 10 9 8 12 11 TRACT A TRACT B SE 138TH PL 248 LF 8" DI (RJ) 304 LF 8" DI (RJ) STA:52+43.25, 4.00' RT FIRE HYDRANT ASSEMBLY PER DISTRICT STANDARD DETAIL NO. 14 1-8"X6" TEE (RJ) 1-6" GATE VALVE 1-8" BLIND FLANGE CONCRETE THRUST BLOCKING PER DISTRICT STANDARD DETAIL NO. 2 10'x5' WATER EASEMENT (TYP.) 13'x5' WATER EASEMENT FOR ADJACENT SERVICES (TYP.) STA:32+46.81, 5.69' RT 1-WATER SERVICE PER DISTRICT STANDARD DETAIL NO. 5 1-WATER METER PER DISTRICT STANDARD DETAIL NO. 4 STA:31+00.93, 12.53' RT 1-WATER SERVICE PER DISTRICT STANDARD DETAIL NO. 5 1-WATER METER PER DISTRICT STANDARD DETAIL NO. 4 STA:30+94.93, 12.38' RT 1-WATER SERVICE PER DISTRICT STANDARD DETAIL NO. 5 1-WATER METER PER DISTRICT STANDARD DETAIL NO. 4 STA:52+32.96, 4.00' RT 1-WATER SERVICE PER DISTRICT STANDARD DETAIL NO. 5 1-WATER METER PER DISTRICT STANDARD DETAIL NO. 4 STA:51+09.63, 4.00' RT 1-WATER SERVICE PER DISTRICT STANDARD DETAIL NO. 5 1-WATER METER PER DISTRICT STANDARD DETAIL NO. 4 STA:51+03.63, 4.00' RT 1-WATER SERVICE PER DISTRICT STANDARD DETAIL NO. 5 1-WATER METER PER DISTRICT STANDARD DETAIL NO. 4 STA:50+73.97, 4.00' RT 1-WATER SERVICE PER DISTRICT STANDARD DETAIL NO. 5 1-WATER METER PER DISTRICT STANDARD DETAIL NO. 4 STA:31+33.97, 12.72' RT RELOCATE EXISTING FIRE HYDRANT ASSEMBLY PER DISTRICT STANDARD DETAIL NO. 14 1-8"X6" CUT IN TEE (RJ) PER DISTRICT STANDARD DETAIL NO. 11 1-8" GATE VALVE 1-6" GATE VALVE CONCRETE THRUST BLOCKING PER DISTRICT STANDARD DETAIL NO. 2 SE 139TH PL SE 5TH PL292 LF 8" DI (RJ) STA: 13+01.41, 4.65 RT = STA: 49+95.09, 4.00 RT 1-8" TEE (FL) 3-8" GATE VALVES MEGALUGS OR APPROVED EQUAL FOR JOINTS AND FITTINGS WITHIN 20' OF TEE STA:13+97.44, 7.30' RT 1-WATER SERVICE PER DISTRICT STANDARD DETAIL NO. 5 1-WATER METER PER DISTRICT STANDARD DETAIL NO. 4 STA:14+66.67, 5.89' RT 1-WATER SERVICE PER DISTRICT STANDARD DETAIL NO. 5 1-WATER METER PER DISTRICT STANDARD DETAIL NO. 4 STA:14+69.20, 5.84' RT 1-WATER SERVICE PER DISTRICT STANDARD DETAIL NO. 5 1-WATER METER PER DISTRICT STANDARD DETAIL NO. 4 STA:14+72.70, 5.77' RT 1-WATER SERVICE PER DISTRICT STANDARD DETAIL NO. 5 1-WATER METER PER DISTRICT STANDARD DETAIL NO. 4 STA:14+75.22, 5.72' RT 1-WATER SERVICE PER DISTRICT STANDARD DETAIL NO. 5 1-WATER METER PER DISTRICT STANDARD DETAIL NO. 4 STA:15+84.61, 11.40' RT 1-WATER SERVICE PER DISTRICT STANDARD DETAIL NO. 5 1-WATER METER PER DISTRICT STANDARD DETAIL NO. 4 CONNECT TO EXISTING WATER MAIN PER WATER CONNECTION DETAIL #2 ON SHEET C1.1 STA: 16+56.97, 15.70 RT = STA: 69+84.25, 2.13 RT 1-8" CUT IN TEE (RJ) PER DISTRICT STANDARD DETAIL NO. 11 2-8" GATE VALVES CONCRETE THRUST BLOCKING PER DISTRICT STANDARD DETAIL NO. 2 7.9' 9.2' 8.4' CONNECT TO EXISTING WATER MAIN PER WATER CONNECTION DETAIL #1 ON SHEET C1.1 STA: 10+09.44, 5.00 RT = STA: 29+89.81, 10.10 RT 1-8" CUT IN TEE (RJ) PER DISTRICT STANDARD DETAIL NO. 11 2-8" GATE VALVES CONCRETE THRUST BLOCKING PER DISTRICT STANDARD DETAIL NO. 2 39 LF 8" DI (RJ) STA:13+53.47, 8.19' RT 1-22.5° BEND CONCRETE THRUST BLOCKING PER DISTRICT STANDARD DETAIL NO. 2 STA:13+40.55, 3.14' RT 1-22.5° BEND CONCRETE THRUST BLOCKING PER DISTRICT STANDARD DETAIL NO. 2 14 LF 8" DI (RJ) 1 2 3 4 5 6 7 9 8 10 5.5' 5.0' 13.2' x 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 4 SK/MWGBRI/JT SE 5TH PL REVISIONS REDUCED SEPARATION DUE TO RETAINING WALL 7/19/2024 7/19/2024 FOR CONSTRUCTION 2221005.10 12600 SE 38TH STREET BELLEVUE, WA 98006 CONTACT: DALTON SMITH PHONE: (888)302-1252 CONNER HOMES MAPLE HIGHLANDS SW 1/4, SEC 14, TWN 23, RGE 5, CITY OF RENTON MAPLE HIGHLANDS - KING COUNTY WATER DISTRICT 90 DATE: July 19, 2024 FILENAME: Q:\2022\2221005\10_CIV\CAD\_Water\2221005-SH-WATR.dwg C1.0 3 WATER PLAN N GRAPHIC SCALE 0 50 100 1" = 50 FEET 25 NOTES 1.LESS THAN 10' STANDARD SEPARATION PROVIDED. REDUCED SEPARATION FROM WATER TO SEWER AS APPROVED BY CITY. 2.7' MINIMUM SEPARATION FROM WATER TO STORM 3.REFER TO LANDSCAPE PLANS FOR IRRIGATION 4.PROVIDE DUCTILE IRON CLASS 52 5.REFER TO CROSSINGS ON SHEET C1.1 6.PROVIDE COPPERHEAD TRACER WIRE SYSTEM PER DISTRICT COPPERHEAD-SPEC MOST CURRENT VERSION. 07/19/2024 375 380 385 390 375 380 385 390 SEWER CONCRETE ENCASEMENT STORM CROSSING STORM CROSSING 0.5' MIN. SEPARATION, PROVIDE CDF BACKFILL STA: 50+73.97 LOT 4 WATER CONNECTION STA: 51+03.63 LOT 5 WATER CONNECTION STA: 51+09.63 LOT 6 WATER CONNECTION STA: 52+32.96 LOT 7 WATER CONNECTION 248 LF 8" D I ( R J ) STA: 52+43.25 FIRE HYDRANT ASSEMBLY STA: 49+95.09 TEE SEWER CROSSING7 8 9 370 375 380 385 390 370 375 380 385 390 STA: 13+01.41 TEE PROTECT EXISTING COMM LINE, APPROXIMATE SIZE/DEPTH/LOCATION. CONTRACTOR TO POTHOLE AND VERIFY SIZE/DEPTH/LOCATION. WATER MAIN CONNECTION APPROXIMATE DEPTH/LOCATION. CONTRACTOR TO POTHOLE AND VERIFY LOCATION AND DEPTH PROTECT EXISTING POWER, APPROXIMATE SIZE/DEPTH/LOCATION. CONTRACTOR TO POTHOLE AND VERIFY SIZE/DEPTH/LOCATION. SIDE SEWER CROSSING STA: 10+09.44 CONNECT TO EXISTING WATER MAIN PER WATER CONNECTION DETAIL #1 THIS SHEET 1-8" CUT IN TEE (RJ) PER DISTRICT STANDARD DETAIL NO. 11 2-8" GATE VALVES CONCRETE THRUST BLOCKING PER DISTRICT STANDARD DETAIL NO. 2 STA: 13+97.44 LOT 12 WATER CONNECTION STA: 14+66.67 LOT 11 WATER CONNECTION STA: 14+69.20 TRACT A IRRIGATION WATER CONNECTION STA: 14+72.70 LOT 3 WATER CONNECTION STA: 14+75.22 LOT 2 WATER CONNECTION STA: 15+84.61 LOT 1 WATER CONNECTION SIDE SEWER CROSSING STA: 16+56.97 CONNECT TO EXISTING WATER MAIN PER WATER CONNECTION DETAIL #2 THIS SHEET 1-8" CUT IN TEE (RJ) PER DISTRICT STANDARD DETAIL NO. 11 2-8" GATE VALVES CONCRETE THRUST BLOCKING PER DISTRICT STANDARD DETAIL NO. 2 292 LF 8" DI (RJ) 304 LF 8" DI ( R J ) CONCRETE ENCASEMENT STORM CROSSING 1 2 3 4 5 6STORM CROSSING 14 LF 8" DI (RJ) 39 LF 8" DI (RJ) STORM CROSSING10 STA: 13+40.55 22.5° BEND STA: 13+53.47 22.5° BEND 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 4 SK/MWGBRI/JT SE 5TH PL REVISIONS REDUCED SEPARATION DUE TO RETAINING WALL 7/19/2024 7/19/2024 FOR CONSTRUCTION 2221005.10 12600 SE 38TH STREET BELLEVUE, WA 98006 CONTACT: DALTON SMITH PHONE: (888)302-1252 CONNER HOMES MAPLE HIGHLANDS SW 1/4, SEC 14, TWN 23, RGE 5, CITY OF RENTON MAPLE HIGHLANDS - KING COUNTY WATER DISTRICT 90 DATE: July 19, 2024 FILENAME: Q:\2022\2221005\10_CIV\CAD\_Water\2221005-SH-WATR.dwg C1.1 4 WATER PROFILES AND DETAILS 153RD AVE SE WATER PROFILE SCALE: H:1"= 50', V:1" = 5' SE 5TH PL WATER PROFILE SCALE: H:1"= 50', V:1" = 5' CONNECTION AND SHUT DOWN NOTES 1.SCHEDULE WITH THE DISTRICT IN WRITING, EMAIL OK (7 DAYS MINIMUM NOTICE) ALL WATER MAIN SHUT-DOWNS AND CONNECTIONS. 2.INSTALLATION OF THE DISTRICT'S STANDARD TESTING CONNECTION IS REQUIRED FOR ALL FLUSHING AND TESTING ACTIVITIES. 3.FOLLOWING COMPLETION OF THE NEW CONSTRUCTION, TESTING, AND ACCEPTANCE BY THE DISTRICT, REMOVE THE TESTING CONNECTION AND INSTALL SEGMENTS OF DI PIPE (LENGTH TO SUIT) WITH TWO (2) RESTRAINED MJ SLEEVES. 4.INSTALLATION AND CONNECTION SHALL BE WITH 100% DISTRICT INSPECTION. 5.ALL CUT-IN-TEES, VALVES, SPOOLS AND COUPLINGS NEED TO BE STERILE SWABBED. 6.CONNECTION CANNOT BE MADE UNTIL ALL TESTING HAS BEEN COMPLETED, PIGS RETRIEVED AND PURITY RESULTS ARE SATISFACTORY. WATER CONNECTION DETAIL #1 SE 5TH PL AND 152ND AVE SE NOT TO SCALE SE 139TH PL SE 5TH PL NEW 8" DI (RJ) WATER MAIN TESTING FINALEX 8" DISE 139TH PL SE 5TH PL152ND AVE SENEW 8" DI (RJ) WATER MAIN INSTALL TEMPORARY 8" CAP (MJ) WITH 2" TAP AND TEMPORARY 2" BLOWOFF ASSEMBLY PER DISTRICT STANDARD DETAIL NO.15 FOR FLUSHING, PRESSURE TESTS, AND PURITY TESTS, LOCATE BLOWOFF CLEAR OF TRAVELED WAY. CONNECT TO EXISTING WATER MAIN 1-8" CUT IN TEE (RJ) PER DISTRICT STANDARD DETAIL NO. 11 2-8" GATE VALVES CONCRETE THRUST BLOCKING PER DISTRICT STANDARD DETAIL NO. 2 WATER CONNECTION DETAIL #2 SE 5TH PL AND 154TH AVE SE NOT TO SCALE SE 5TH PL SE 5TH PL NEW 8" DI (RJ) WATER MAIN TESTING FINAL INSTALL TEMPORARY 8" CAP (MJ) WITH 2" TAP AND TEMPORARY 2" BLOWOFF ASSEMBLY PER DISTRICT STANDARD DETAIL NO.15 FOR FLUSHING, PRESSURE TESTS, AND PURITY TESTS, LOCATE BLOWOFF CLEAR OF TRAVELED WAY. CONNECT TO EXISTING WATER MAIN 1-8" CUT IN TEE (RJ) PER DISTRICT STANDARD DETAIL NO. 11 2-8" GATE VALVES CONCRETE THRUST BLOCKING PER DISTRICT STANDARD DETAIL NO. 2 EX 8" DI154TH AVE SEEX 8" DI152ND AVE SEEX 8" DIEX 8" DISE 5TH PL SE 5TH PL NEW 8" DI (RJ) WATER MAIN EX 8" DI154TH AVE SE1.2'± EXIST. 2" COMM PROP. 8" WATER 0.5'± EXIST. 2" POWER PROP. 8" WATER 1.0' PROP. 8" WATER IE= 380.4± PROP. 6" SEWER T.O.P= 379.4 5.2' PROP. 8" WATER IE= 382.8± PROP. 18" STORM T.O.P= 377.6 IE= 382.4± T.O.P= 381.2± 0.8' PROP. 8" WATER IE= 379.4± PROP. 8" SEWER T.O.P= 378.6 PROP. 12" STORM IE= 380.5 PROP. 8" WATER T.O.P= 380.0± IE= 381.7± T.O.P= 381.2± 1.0' PROP. 12" STORM IE= 380.1 PROP. 8" WATER T.O.P= 379.1± 21 3 654 987 1.6' PROP. 8" WATER IE= 381.5± PROP. 6" SEWER T.O.P= 379.3 2.7' PROP. 8" WATER IE= 384.7 PROP. 12" STORM T.O.P= 382.0 0.5' MIN CROSSINGS NOT TO SCALE 1.4' PROP. 8" STORM IE= 381.8 PROP. 8" WATER T.O.P= 380.4± 10 07/19/2024