AS A CONDITION OF APPROVAL
STRUCTURAL CALCULATIONS FOR
THE FOUNDATION DESIGN SHALL
BE SUBMIT TO THE DEVELOPMENT
ENGINEERING PROJECT MANAGER
PRIOR TO INSTALLATION.
DocuSign Envelope ID:
T
PAINT SPECIFICATIONS:
ALL LUMINAIRE, POLE, CAST ALUMINUM BASE PARTS. AND
ANY ADDITIONAL EQUIPMENT MOUNTED ON THE POLE
SHALL BE FACTORY PRIMED AND POWDER COATED TO
MATCH FINISH COLOR.
ALL BANDING AND ALL OTHER MOUNTING HARDWARE
SHALL MATCH FINISH COLOR.
FINISH COLOR: RAL 9005TX "JET BLACK% OR APPROVED
EQUAL WITH PAINT CHIP.
DECORATIVE LUMINAIRE POLE NOTES
© ROUND TUBULAR SECTION
(NO TAPER)
DOME STYLE LED LUMINAIRE
(WATTAGE PER PLANS, TYPE 3 IES
tr DISTRIBUTION, 4000K OCT, 120-277V
w UNIVERSAL DRIVER (75OmA OR
LOWER), WITH FLAT GLASS LENS) BY
CYCLONE (OR APPROVED EQUAL)
DRIVER SHALL BE INTEGRAL TO THE
FIXTURE. FOR MOUNTING ARM DETAILS
SEE STD PLAN 117.3. WIRING PER 4'-0"
o STD PLAN 119.
LUMINAIRE
18°
FOR STREET LIGHT STANDARD DECAL
k NUMBERING DETAIL, REFER TO CITY OF
a RENTON STD PLAN 121
POLE SHAFT FABRICATED FROM 6063-T4
wo ALUMINUM, HEAT TREATED TO T6 CONDITION
AFTER WELDING. 10" O.D. x 0.250" WALL AT
coo BOTTOM OF POLE SHAFT, 9.375" O.D. AT 27"
F UP FROM BUTT OF POLE. TAPERED BETWEEN
of LUMINAIRE CONNECTIONS
0 0
_ NOTE:
STANDARD PLANS REQUIRES
STRUCTURAL CALCULATIONS FOR THE
FOUNDATION. CONDITION TO BE ADDED
ON PERMIT THAT SUCH CALCULATIONS
561D7F SHALL BE PROVIDED PRIOR TO
INSTALLATION OF FOUNDATION.
-ROUND POLE CAP
ALUMINIUM SHROUD (BY MANUFACTURER)
DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, TYPE 3 IES
LUMINAIRE ARM LENGTH DISTRIBUTION, 4000K COT, 120-277V UNIVERSAL DRIVER (750mA OR
PER PLANS, 10' MAX LOWER), WITH FLAT GLASS LENS) BY CYCLONE (OR APPROVED EQUAL)
DRIVER SHALL BE INTEGRAL TO THE FIXTURE FOR MOUNTING ARM
DETAILS SEE STD PLAN 117-3. WIRING PER STD PLAN 119.
(6) 1.38" DIA. X 2" LONG SLOTTED
HOLES WITH 1 i/4° DIA, 4° HEX
27 $"
HEAD CONNECTING BOLTS AND NUTS A36 STEEL,
�1 Y,° THICK
BASE PLATE
,VOID
15"4 BOLT CIRCLE
POLE BASE PLATE DETAIL
FOUNDATION SHALL SUPPORT
POLE SHOWN IN STANDARD PLAN
.'
DECORATIVE BASE COVER PER
DETAIL, THIS SHEET
Z 4
o
m
4° X B" REINFORCED ALUMINUM HANDHOLE
OPENING WITH 5/16"-18 HOLE FORA
GROUND CONNECTOR AND FLUSH FITTING
ALUMINUM DOOR W/ GASKET
CAST ALUMINUM ANCHOR BASE,
INSTALL ANCHOR BOLT COVERS
(PROVIDED BY POLE
.-,
MANUFACTURER)
CONCRETE PAD/SIDEWALK PER STD PLAN
FOUNDATION PER STRUCTURAL ANAI
6" HIGH SIDEWALK
°i OR PLANTER STRIP
-A=F
ROADWAY
20 IF SURFACE IS NOT LEVEL, INSTALL
GROUT AT BASE OF POLE AND
.IS BASE COVER, PROVIDE 1/2" DIA
DRAIN TUBE THROUGH GROUT
POLE ELEVATION
117.1A
FOUNDATION, AND ANCHOR BOLT
DETAILS PER STANDARD PLAN
O
F180HI2111
9
• DECORATIVE ROADWAY LUMINAIRES
ARE MOUNTED AT V
• DECORATIVE PEDESTRIAN LUMINAIRES
ARE MOUNTED AT 180'
• HANDHOLES ARE MOUNTED AT 180'
ORIENTATION LOCATION
9V
OCTAGONAL SPLIT Ti OP I'D�
CAST IRON BASE
WITH REMOVABLE
ACCESS DOOR
z I
21"
DECORATIVE BASE COVER
ARTERIAL STREET STD. PLAN - 117.1
T PUBLIC WORKS DECORATIVE LUMINAIRE POLE
. � . APPROVED:
�F o� DEPARTMENT DETAILS �M�artlnPastucha 7/27/2022
DATE
DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F
7'-0"
LUMINAIRE POLE \ JUNCTION BOX
CONCRETE PAD,
PLAN VIEW BROOM FINISH
LUMINAIRE POLE
CONCRETE PAD
Z
4"
_r - JUNCTION BOX
LUMINAIRE CONCRETE
FOUNDATION
SIDE VIEW
LUMINAIRE CONCRETE PAD DETAIL
GENERAL NOTES:
1. LUMINAIRE CONCRETE PAD SHALL BE USED IN AREAS
OUTSIDE OF SIDEWALK
2. CONCRETE CLASS FOR LUMINAIRE CONCRETE PAD SHALL
BE PER STD PLAN 135
3. TOP OF LUMINAIRE FOUNDATION ELEVATION SHALL BE
LOCATED AT BOTTOM OF LUMINAIRE CONCRETE PAD
ELEVATION OR BOTTOM OF SIDEWALK ELEVA11ON
4. LUMINAIRE POLE AND JUNCTION BOX TYPE PER PLAN
5. LUMINAIRE CONCRETE PAD ACCOMMODATES TYPE 1 AND
TYPE 2 JUNCTION BOXES ONLY
LUMINAIRE POLE JUNCTION BOX
CONCRETE SIDEWALK
PLAN NEW PER STD PLAN 102
UMINAIRE POLE
CONCRETE SIDEWALK
PER STD PLAN 102
� JUNCTION BOX
--LUMINAIRE CONCRETE
FOUNDATION
SIDE VIEW
LUMINAIRE WITH SIDEWALK DETAIL
CONCRETE PAD J / 1'-0.
JUNCTION BOX J/ PLAN VIEW
4"
CONCRETE PAD
JUNCTION BOX SIDE VIEW
INDIVIDUAL JUNCTION BOX PAD DETAIL
��Y a LUMINAIRE CONCRETE STD. PLAN - 120
PUBLIC WORKS PAD/SIDEWALK AND
+� + APPROVED:
p DEPARTMENT JUNCTION BOX CONCRETE PAD MartlnPastueha 712712022
NZ�
DATE
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
NE 1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F _ aCKET CABLE, #10
AWG. SPLICES BETWEEN FUSE
HOLDER AND LUMINAIRE FIXTURE
SHALL NOT BE ALLOWED
FUSE KITS QUICK DISCONNECT 3 AMP 1 TO LUMINAIRE
TO RECEPTACLE
IN LINE FUSE KITS S.E.C. OR EQUAL,
ONE PER CURRENT CARRYING 120VAC RECEPTACLE WIRING, IF
REFER TO WSDOT LOCKING CONDUCTOR. APPLIES TO LUMINAIRE APPLICABLE. WIRING SIZE PER
LID STANDARD DUTY AND RECEPTACLE WIRING CONTRACT
JUNCTION BOX TYPES 1 & TO LUMINAIRE
2 STANDARD PLAN J-40.10 GREEN INSULATED WIRE, SIZED
SPLICE KITS CLEAR EPDXY SPLICE GROUND LUG TO MATCH THE LARGEST
KITS ON ALL THRU WIRE RUNS CURRENT CARRYING CONDUCTOR.
CONCRETE PAD OR TERMINATE AT LUMINAIRE
SIDEWALK PER STD PLAN 120 GROUND LUG
24"(MIN) COVER #8 BARE COPPER II / NON -INSULATED 4 AWG
GROUND WIRE GROUND #
CLAMP II II STRANDED COPPER,
II PROVIDE 3' MIN. SLACK.
1 -EQUIPMENT GROUND 2" PVC CONDUIT II ROUTE FROM GROUNDING
WIRE W/GREEN INSULATION REBARO CONNEECTIOTO
FROM SERVICE CABINET, REBAR USING AN ACORN
SEE NOTE 2, THIS SHEET CLAMP
2 - LIGHTING SYSTEM ROUN' COPPER CLAD GCONCRETE FOUNDATION
WIRES TO CONTACTOR GROUND ROD
(SIZED AS REQ'D.)
2 - 120VAC RECEPTACLE SYSTEM
WIRES TO SERVICE CABINET, IF
APPLICABLE (SIZED AS REQ'D.)
NOTES:
1. THIS DETAIL DEPICTS THE BASIC LUMINAIRE ELECTRICAL WIRING SYSTEM. ADDITIONAL ELECTRICAL EQUIPMENT MAY VARY.
2. MINIMUM GROUND WIRE SIZE SHALL BE #8, AS SHOWN ABOVE. IF CURRENT CARRYING CONDUCTORS ARE LARGER THAN
#8, THE MINIMUM GROUND WIRE SIZE SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING CONDUCTORS.
3. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE
HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE.
4. IF THE FIXTURE MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF A GROUND WIRE, A GREEN INSULATED
WIRE, SIZED TO MATCH THE LARGEST CURRENT CARRYING CONDUCTORS, SHALL BE RUN FROM THE FIXTURE TO THE POLE
GROUND LUG.
5. ALL CONDUIT SHALL BE PVC SCHEDULE 80.
�Y LUMINAIRE ELECTRICAL
STD. PLAN - 119
PUBLIC WORKS WIRING SYSTEM
.� . APPROVED:
DEPARTMENT Martin Pastucha 7/27/2022 I
DATE
DocuSign Envelope ID: 9D9B0DA8-03854664-AE66-57BFF1561D7F
INSTALL DECAL NUMBERS/LETTERS VERTICALLY.
DECAL NUMBERS/LETTERS, SEE NUMBERING
EXAMPLE, THIS SHEET. SHALL BE INSTALLED IN
DRY WEATHER, 50° F OR ABOVE
=m
66
z�
7
Z¢
CD
��
NUMBERING EXAMPLE
Tn
^o
a-
w
MOUNTING HEIGHT DETAIL
1-3/4" TO 2"
I-PEDESTRIAN
SCALE
CURB DECAL
TRAFFIC
FLOW
DECAL ORIEWA710111
FOR POLES SHOWN ON STD PLAN 11&1
PEDESTRIAN SCALE
i:1-PEDESTRIAN
DECAL
SCALE 0�
CURB DECAL CURB
TRAFFIC TRAFFIC
FLOW FLOW
DECAL DRIENTA7111XII
FOR POLE8 8MM ON STD PLAN 1172
-4 TRAFFIC
FLOW
DECAL ORIENrATNNI
FOR POLES SHOWN ON STD PLAN 117.1 & 117,1A
SCALE
CALE
U�cY oT LUMINAIRE STANDARD DECAL STD. PLAN - 121
+�+ PUBLIC WORKS NUMBERING SYSTEM APPROVED:
p DEPARTMENT MartlnPastucha ��z�/zoz2
N S DATE
Know what's below.
Call before you dig.
8/23/2024
PER CITY COMMENTS
PER CITY COMMENTS
PER CITY COMMENTS
PER CITY COMMENTS
REVISION
HEARING EXAMINERS FINAL DECISION
THE PROPOSED PRELIMINARY PLAT ( INCLUDING QUALIFYING AS A UNIT LOT SUBDIVISION), HEARING
EXAMINER SITE PLAN, PARKING MODIFICATION, STREET STANDARDS MODIFICATION AND A LANDSCAPE
VARIANCE COMPLY WITH ALL APPLICABLE CRITERIA FOR THE REASONS IDENTIFIED IN THE CONCLUSIONS OF
LAW OF THIS DECISION AND ARE ALL APPROVED, SUBJECT TO THE FOLLOWING CONDITIONS:
1. A FINAL TREE REPLACEMENT PLAN SHALL BE SUBMITTED AT THE TIME OF CONSTRUCTION PERMIT
REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER. THE FINAL TREE
REPLACEMENT PLAN SHALL INCLUDE THE PLANTING OF AN ADDITIONAL 52.5 TREE CREDITS ON THE
PROJECT SITE.
2. THE FLOOR PLANS SHALL BE REVISED TO IDENTIFY THE REQUIRED BICYCLE PARKING SPACE WITHIN
THE PROPOSED GARAGES. THE REVISED FLOOR PLANS SHALL BE SUBMITTED TO THE CURRENT
PLANNING PROJECT MANAGER AT THE TIME OF BUILDING PERMIT REVIEW FOR THE REVIEW AND
APPROVAL OF THE CURRENT PLANNING PROJECT MANAGER.
3. REVISED FLOOR PLANS SHALL BE SUBMITTED AT THE TIME OF BUILDING PERMIT REVIEW SHOWING THE
REQUIRED TWO FEET BY SIX FEET (2' X 6') FLOOR AREA AND SIXTY INCHES (60") HIGH STORAGE AREA
FOR THE INDIVIDUAL REFUSE AND RECYCLING CARTS. IN ADDITION, SITE PLAN SHALL BE REVISED TO
INCLUDE SPACE FOR CARTS TO BE PLACED ON GARBAGE PICK-UP DAY. THE SPACE MUST BE
SUFFICIENT TO ACCOMMODATE THE NUMBER OF CARTS EXPECTED TO BE SERVICED ON PICK-UP DAY.
THERE SHALL BE A DIRECT CONNECTION CONSTRUCTED OF A SMOOTH SURFACE THAT ALLOWS CARTS
TO BE SMOOTHLY ROLLED TO THE STREET OR OTHER SPECIFIED PICK-UP LOCATION. THE REVISED SITE
PLAN SHALL BE SUBMITTED TO THE CURRENT PLANNING PROJECT MANAGER AT THE TIME OF
CONSTRUCTION PERMIT REVIEW.
4. A CROSS SECTION WITH TOP AND TOE MEASUREMENTS AND MATERIAL COMPOSITION OF THE
PROPOSED RETAINING WALL SHALL BE PROVIDED TO THE CURRENT PLANNING PROJECT MANAGER AT
THE TIME OF CONSTRUCTION PERMIT REVIEW FOR REVIEW AND APPROVAL.
5. A REVISED LANDSCAPE PLAN SHALL BE SUBMITTED AT THE TIME OF CONSTRUCTION PERMIT REVIEW
INCLUDING A FENCING DETAIL DEMONSTRATING THAT THE TOTAL COMBINED HEIGHT OF ANY FENCING
PROPOSED ON TOP OF A RETAINING WALL WOULD NOT EXCEED THE MAXIMUM HEIGHT PERMITTED FOR
A STANDALONE FENCE. THE FENCING DETAIL SHALL BE SUBMITTED TO THE CURRENT PLANNING
PROJECT MANAGER FOR REVIEW AND APPROVAL.
6. A REVISED LANDSCAPE PLAN SHALL BE SUBMITTED AT THE TIME OF CONSTRUCTION PERMIT REVIEW
FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER. THE REVISED
LANDSCAPE PLAN SHALL INCLUDE A THREE-FOOT (T) LANDSCAPED SETBACK BETWEEN ANY RETAINING
WALLS AND THE FRONT PROPERTY LINE ALONG GRANT AVE S.
7. THE PROJECT PROPOSAL SHALL INCORPORATE A VARIETY OF ROOFING COLORS AND THAT THE
ROOFING MATERIAL SHALL BE FIRE RETARDANT. REVISED COLORED ELEVATIONS DEMONSTRATING
COMPLIANCE WITH THIS REQUIREMENT SHALL BE SUBMITTED TO THE CURRENT PLANNING PROJECT
MANAGER AT THE TIME OF BUILDING PERMIT REVIEW.
8. THE APPLICANT SHALL EITHER SUBMIT REVISED ELEVATIONS PROVIDING THE REQUIRED THREE AND
ONE-HALF INCHES (3 1/2") MINIMUM TRIM SURROUNDING ALL WINDOWS AND DOORS AND ONE OF THE
FOLLOWING ARCHITECTURAL DETAILS: SHUTTERS, KNEE BRACES, FLOWER BOXES, OR COLUMNS.
ALTERNATIVELY, THE APPLICANT MAY SUBMIT AN ALTERNATIVE THAT MEETS THE INTENT AND
GUIDELINES OF THE DESIGN SECTION. THE REVISED ELEVATIONS SHALL BE SUBMITTED TO THE
CURRENT PLANNING PROJECT MANAGER FOR REVIEW AND APPROVAL AT THE TIME OF BUILDING
PERMIT REVIEW.
9. A FULLY DETAILED MATERIALS BOARD AND COLOR PALETTE CODED TO EACH BUILDING ELEVATION,
SHALL BE PROVIDED TO THE CURRENT PLANNING PROJECT MANAGER FOR REVIEW AND APPROVAL AT
THE TIME OF BUILDING PERMIT REVIEW.
10. THE APPLICANT SHALL SUBMIT A SEPARATE DETAILED UTILITY AND LANDSCAPE PLAN SET IDENTIFYING
THE LOCATION AND SCREENING PROVIDED FOR ALL SURFACE UTILITY/MECHANICAL EQUIPMENT
REQUIRED FOR EACH TOWNHOME. THE SURFACE MOUNTED UTILITY PLAN SHALL INCLUDE
CROSS-SECTION DETAILS AND SCREENING MEASURES CONSISTENT WITH THE OVERALL DESIGN OF THE
DEVELOPMENT WITH THE CIVIL CONSTRUCTION PERMIT APPLICATION. THE APPLICANT SHALL WORK
WITH FRANCHISE UTILITIES TO ENSURE, AS PRACTICAL, UTILITY BOXES ARE LOCATED OUT OF PUBLIC
ROW VIEW, ACTIVE COMMON OPEN SPACES, AND THEY SHALL NOT DISPLACE REQUIRED LANDSCAPING
AREAS. THE UTILITY AND LANDSCAPE PLAN SET SHALL BE REVIEWED AND APPROVED BY THE CURRENT
PLANNING PROJECT MANAGER PRIOR TO PERMIT ISSUANCE.
11. A SIX-INCH (T) VERTICAL CURB SHALL BE INSTALLED BETWEEN THE UNIT LOT DRIVEWAY AND ABUTTING
LANDSCAPED AREAS. REVISED CIVIL PLANS SHOWING THE CURB SHALL BY SUBMITTED AT THE TIME OF
CONSTRUCTION PERMIT REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT
MANAGER.
12. THE APPLICANT SHALL CREATE A HOMEOWNERS' ASSOCIATION ("HOA") THAT MAINTAINS ALL
IMPROVEMENTS AND LANDSCAPING IN THE COMMON OPEN SPACE TRACTS AND ANY AND ALL OTHER
COMMON IMPROVEMENTS. THE HOA DOCUMENTS SHALL BE SUBMITTED TO, AND APPROVED BY, THE
CURRENT PLANNING PROJECT MANAGER PRIOR TO RECORDING OF THE UNIT LOT SUBDIVISION. SUCH
DOCUMENTS SHALL BE RECORDED CONCURRENTLY WITH THE UNIT LOT SUBDIVISION.
13. ALL TRACTS (E.G. UNIT LOT DRIVEWAY, DRAINAGE, OPEN SPACE, ETC.) SHALL BE PLACED WITHIN
SEPARATE TRACTS THAT WOULD BE OWNED AND MAINTAINED BY THE HOMEOWNER'S ASSOCIATION.
14. ALL PRIVATE OPEN SPACE AREAS ATTRIBUTED TO EACH INDIVIDUAL DWELLING UNIT SHALL BE LOCATED
ON THE SAME UNIT LOT AS THE DWELLING UNIT. A REVISED PLAT MAP SHALL BE SUBMITTED AT THE
TIME OF CONSTRUCTION PERMIT REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING
PROJECT MANAGER, THAT DEMONSTRATES COMPLIANCE WITH THIS REQUIREMENT.
15. THE APPLICANT SHALL BE REQUIRED TO DEMONSTRATE SAFE WALKING CONDITIONS TO/FROM THE
SUBJECT PLAT TO BUS STOP LOCATIONS PRIOR TO CONSTRUCTION PERMIT ISSUANCE.
DATED this 6th day of November, 2023.
City of Renton Hearing Examiner
SURVEYED:
DAF
08/26/24
DESIGNED:
DAF
DAF
07/29/24
DAF
05/21 /24
oRAwN:
TJW, FEM
DAF
04/04/24
CHECKED:
DAF
BY
DATE
I APPR
APPROVED:
SCALE:
1 "=30,
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
ENVIRONMENTAL REVIEW COMMITTEE (ERC)
DETERMINATION OF NON -SIGNIFICANCE -MITIGATED (DNS-M)
PROJECT FILE NUMBERS:
PR23- 000126 / LUA23- 000283, PP, SA- H, ECF, MOD, V-H
PROJECT NAME:
GRANT PLACE TOWNHOMES
APPLICANT
SATWANT SINGH, 15 S GRADY WAY, SUITE 527, RENTON, WA 98057
PROJECT LOCATION:
1504- 1582 SE GRANT CIRCLE, RENTON, WA 98055 ( PARCEL NO. 2023059052)
PROJECT DESCRIPTION:
THE APPLICANT IS REQUESTING PRELIMINARY PLAT APPROVAL, HEARING EXAMINER SITE
PLAN REVIEW, ENVIRONMENTAL (SEPA) REVIEW, A PARKING MODIFICATION, A STREET
STANDARDS MODIFICATION, AND A LANDSCAPE VARIANCE FOR THE CONSTRUCTION OF A
MULTI- FAMILY DEVELOPMENT CONTAINING A UNIT LOT SUBDIVISION WITH 36
TOWNHOMES. THE PROJECT SITE TOTALS APPROXIMATELY 2.14 ACRES AND IS LOCATED
WITHIN THE RESIDENTIAL MULTI- FAMILY (RMF) ZONING CLASSIFICATION, AND THE
RESIDENTIAL HIGH DENSITY (RHD) LAND USE DESIGNATION. THE DEVELOPMENT WOULD
BE COMPRISED OF EIGHT (8) SEPARATE MULTI- FAMILY RESIDENTIAL STRUCTURES.
ACCESS TO THE SITE IS PROPOSED VIA NEW LOOP ACCESS DRIVE EXTENDED FROM
GRANT AVE S. A PARKING MODIFICATION IS REQUESTED AS THE PARKING STALLS WOULD
NOT COMPLY WITH THE MINIMUM DIMENSIONAL REQUIREMENT, A LANDSCAPE SETBACK
VARIANCE IS REQUESTED TO VARY FROM THE 15-FOOT BUFFER REQUIRED ABUTTING A
RESIDENTIALLY ZONED PROPERTY, AND A STREET STANDARDS MODIFICATION WAS
REQUESTED TO MODIFY THE UNIT LOT DRIVEWAY STANDARDS. THE PROPOSED
DEVELOPMENT IS LOCATED ON A PARTIALLY- DEVELOPED SITE THAT WAS ORIGINALLY
PART OF THE EXPIRED GRANT PLACE TOWNHOMES PRELIMINARY PLAT AND PLANNED
URBAN DEVELOPMENT (PUD) (LUA15- 000885 AND LUA17- 000335). THE PRELIMINARY PLAT
AND PUD APPLICATIONS HAVE EXPIRED AND THE PROPOSED TOWNHOME DEVELOPMENT
WOULD REQUIRE NEW LAND USE APPROVALS. THE SITE IS MAPPED WITH SENSITIVE
SLOPES, MODERATE COAL MINE HAZARDS, MODERATE LANDSLIDE HAZARDS, HIGH
EROSION HAZARDS, AND SEISMIC FAULTS.
LEAD AGENCY:
CITY OF RENTON
ENVIRONMENTAL REVIEW COMMITTEE
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT
DATE OF DECISION:
SEPTEMBER 18, 2023
MITIGATION MEASURES:
1. PROJECT CONSTRUCTION SHALL COMPLY WITH THE RECOMMENDATIONS OUTLINED
IN THE GEOTECHNICAL REPORT PREPARED BY NELSON GEOTECHNICAL
ASSOCIATES, INC., DATED JUNE 10, 2005 AS WELL AS THE GEOTECHNICAL LETTER
PREPARED BY COBALT GEOSCIENCES, LLC, DATED MARCH 3, 2023.
2. THE APPLICANT SHALL SUBMIT AN INADVERTENT DISCOVERIES PLAN PREPARED BY
A QUALIFIED PROFESSIONAL WITH THE CIVIL CONSTRUCTION PERMIT FOR REVIEW
AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO PERMIT
ISSUANCE.
3. THE DUWAMISH TRIBE SHALL ALSO BE NOTIFIED IF ANY ARCHEOLOGICAL WORK OR
MONITORING IS PERFORMED ON THE PROJECT SITE.
THE CITY OF RENTON ENVIRONMENTAL REVIEW COMMITTEE HAS DETERMINED THAT
PROBABLE SIGNIFICANT ENVIRONMENTAL IMPACTS FROM THE PROPOSED PROJECT CAN
BE MITIGATED. AN ENVIRONMENTAL IMPACT STATEMENT ( EIS) IS NOT REQUIRED UNDER
RCW 43.21C.030(2)(C). CONDITIONS WERE IMPOSED AS MITIGATION MEASURES BY THE
ENVIRONMENTAL REVIEW COMMITTEE UNDER THEIR AUTHORITY OF SECTION 4-9-070D
RENTON MUNICIPAL CODE. THESE CONDITIONS ARE NECESSARY TO MITIGATE
ENVIRONMENTAL IMPACTS IDENTIFIED DURING THE ENVIRONMENTAL REVIEW PROCESS.
SIGNATURES: DocuSlgned by:
1AAC4DOD98D92A54AO.
njela Barton
_ 9/18/2023 1 2:19 PM PDT
Martin Pastucha, Administrator Date Anjela Barton, Fire Marshal Date
P4Wj,rsi 4s, Chair EVanessa
"acQP0ignal Fire Authority
EF578322688C8E4E2
V" Cale9/18/2023 1 3:23 PM PDT Dolbee 9/18/2023 1 2:24 PM PDT
._53D381 F958CE4E4.--
Maryjane Van Cleave, Interim Administrator Date Vanessa Dolbee, Interim Administrator Date
Parks and Recreation Community and Economic Development
FURR
EN6INEERIN6
QERVICE.% PLLC
4715 142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
CITY OF
RENTON
Planning/Building/Public Works Dept.
�J
co
a
J
R-429002 I�
IN COMPLIANCE WITH CITY OF RENTON STANDARDS =O
DEVELOPMENT ENGINEERING z
NJanders 09/16/2024
O
LU
U
Q
DATE: J
GRANT PLACE TOWNHOMES 11/21/23 0-
1600 GRANT AVE S RENTON, WA 98055 FIELDBOOK:
PARCEL 2023059052 PAGE:
DRAWING N0:
20069
CONDITIONS OF APPROVAL SHEET: OF:
C1.1 28 V