No preview available
HomeMy WebLinkAboutR-4290040 N 0 W V ) W 75 O 2 z O I- W CU n I- z 0 O N U NE 1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N., R. 05 E, W.M. GRANT PLACE TOWNHOMES I I SDMH-1 (T2) CB-1 Ti RIM=294.51 Q- RIM=293.78 12 CMP N=290.01 12" CMP S=290.58 12" CMP E=286.71 8" CMP W=290.93 12" CMP S=287.21 SFMH (T2) 12" CMP W=286.61 RIM=300.62 /;;•, 1-' 12" CMP S=290.82 SDMH-2 (T2) *WESTERLY INVERT IS COVERED :• TOP CONC. RISER=295.72 BY CONTECH INTERNALS 12" CMP E=288.17 12" CMP 5E=288.37 CB-8 (TYPE ,> �/� GB-9 (TYPE 1) �1 PORTION OF PARCEL 2 31 9)013 CB-12 (TYPE 1) RIM= (TYPE J �� RIM CPEP E&W=312.18 1 L CB-10 (TYPE 1) R� 327.42 w RIM= 335.24 TYP 4 RIM CPEP E&5=300.63 01 437 RIM= 319.14 12" CPEP E&W= 323.97 w 12" CPEP E&W= 332.19EXPOS O LTOP'OFBPIPE S PIPE 289.28 / c p\ 12" CPEP E\= 315.99 \ / 1 \ \ \ \ \ \ I -3 30'l // /� / / N89"09'24"E 30' rn \ I (' JI ROCKERY \ ROCKERY �,V F S ;: IF RO ERY < _ < - �S < < < < \ RIK1133 �11) �� 40.77 3+00 _.., . ✓ 5 �" CF)EP NW& = 3 s.a - - - _ h i 5 - I �'�:,<5 - ! - �. �. S � ��.b•,� �4�4,� �,��dy.�4,� r,,X:6,�ad. �`a.rux` �.� .�' I •ssco ,F. I r� I ,� „� '' �, • lam(/J / s�o ssco w SSCO - . SSCO I SSCO SSCO / SSCO SSCO q ,, ,~ ` I •;�i�, o SSCO � � FH SSMH-10 , FF=359.52 FF=361.03 FF=3�.52 - "ep FH RIM- 35Fi10 I FF=357.98 BUILDING 4 FF-36401 \\ FF=333.44 I TI�CH.= 326.80 '• FF=334.94 1 J �1 a• J I 0 \ WATER SERVICE FF=331.59 FF=333.31 ^ -/ f;•, ! 1 G yy, VLACCESS GIP WATER SERVICE WATER SERVICE WATER SERVICE o� AO' WATER SERVICE LINE ETER LOCATION WATER SERVICE WATER SERVICE �q0� LINE M 12" C P \ SMH-9 / LINE/METER LOCATION LINE/METER LOCATION LINE/METER LOCATION WATER SERVICE :;y( •`; \ / ETER LOCATION LINE/METER LOCATION FF=354. 6 `gyp PP�� / \ LINE/METER LOCATION '•.''{?` \ \ FF=351.13 FF=354.22 / \ \ N=288.61 4IM= 13.68 / LINE/METER LOCATION 3 _ `l FF=348.19 FF=349.75 / y TTTffi p \ CTR. �H.= 306.2 GIPI f\\ FF=352.61 � FF=343.57 FF=344.56 N=290. ' t» SSCO \ VLT S 8 \/ \ BUILDING 2 / pR PIP `;+°;XT!'-.7„, SSCO SSC SSCO LID=3 \ • ' KEYST NE I I BUILDING 1 ( FOUNDATION ONLY i FF=343.03 FF=343.04 1 i , w B-7 (N ID) \ b 12" CPEP /WALL w (FOUNDATION ONLY) ( ) / ssco WJe \ -TOP CO .STRUCTURE ":• \ \ / N=295.57 / I \�f I ( \ o / I F: o M \ = 353.7 O F ....'.. •:.�..:":'.:' + 0' :•• 12" CPE = 349.02 I__CB (TYPE 1) NO RIM ( \ I \ I \ \ 12" CPEP 3 \ \ \ CB-16 (T1E 1) CB-17 (TYPE 1) WV y•;.,.. SS / OI 2 RIM=325.1 I RIM=334.44 I '' SSMH-8 ('�') O i o w \ 2.05AC DISTURBED AREA / \ \ wv , .; :. 5 RIM= 353/i4 \ L I 0 I \ \ \ 12" CPEP SW=312.67 / N 12" CPEP 323.03 I 12" CPEP W=332.3d �'y O \ CB-6 ( �':�' °?'." / SSCO / , / 00 r ' 0 O 4` PVC 5=315.47 \ 12" CPEP=323.03 RIM= 343 .9;:.•'.: .`'" :. C/0 3 7 0 �`° �` : \ I I I I `aao / / 7 / \ I I 1 \ / i \ \ \ ssco ssco w CD n • ( 12" CPEP 5 O ACCESS 5 12" CPEP �� / ( \ l l I I \ / \ \ "' / N O �'" •1:"; , / \ D=304.90 \ E=289.21 I SD SD SD SSMH- ,; ;llP FF=34 .53 FF=350.87 FF=352.46 FF=353.96 O OZ O \ T ACCES 4 \ :• \ Y. . ID=304.18 FF=348.25 WATER SERVICE J ACCESS 1 0� I C FT . ;33 .1f+;, :. WATER SERVICE LINE/METER LOCATION _ 0 ~" LID=308.85 \ ` 1 FF= 41.57 LINE/METER LOCATION BUILDING 5 O yyI \ \ BUILDING % \ FF=341.54 \ " BUILDING 8 \ `- FF=343.08 FF=364.01 z Q \ \ \ ) \ \ (FOUNDATION ONLY) BUILDING 6 FF=357.99 FOUNDATION ONLY FF=340.19 ^r:. ". ?.,;' + \/ I FF=360.98 FF=362.52 I ( ) ..:...:..v...... I 3 \ VLT ACCESS 3 0 307.4 FF=359.48 0 * ° �O D=ACC g O \ I WATER SERVICE WATER SERVICE AO//` FH \ \ IN LOCATION LINE/METER LOCATION B ":.;- I WATER SERVICE PR 1 GIP WATER SERVICE � ; Si".'..;.;•:,:::.:,; ' / \ WATER SERVICE LINE/METER LOCATION LINE ME R LOCATION FF=3 0.35 FF=331.80 FF=333.47 PM ':, : O"•';." i ACCESS 2 \ WATER SERVICE / / H. LID=3 8.09 U) LINE ETER LOCATION 330� \ x; /0 55 :n /M LINE/METER LOCATION I SS H-6 (TYP 2) \ \ �5.SNAG ` FH \ \ V I C/0 I I ` \ FH \ _ .,',.;,.:.',;;•.1 I 7 t. C 332.$1 \ . ,sue,., SSCO SSCO SSCO „ , ,, 1/I � "�M �341.81 \ 12" CPEP I \ \ SSCO SSC SSCO\ \ �,V / ',i::.:!!, ,.�:,Gj _`,i,•. I SF D G I / S=288.98 I \ SSCO / SSCO SSCU SSCO WV / \ I ) 6A'..' P F E F :�ti:. P x. ,1 Y / 1 2 •� 5 - P r 0 1 A V 0 - - 1 / 5. N G R • 5 a :s / r s• ,. 0 0 , - P ' S� cry r- _ E 2 ELECTRICAL 1:'" `"' / i CB-5 ( E 1) g O JUNCTION BOX t. CH BASIN (T1) CB- (TYPE 1) \ \ CB 4 (TYPE Ij 544'71 / / / c POWER 14.SNAG / �� v CB-3 TYPE 1) RIM= 333.51 t PV \ RIA 306.21 \ SSMH-4 (TYPE 2) RIM- 14.10 ( b(D 12" CPEP E= 321.85 8" PVC NE= 331.06 SSMH-5 (TYPE 2) INDICATOR POST �y GV .L 12" CPEP E=302.54 RIM= 317.67 RIM-313.13 12 CPEP E=311.00 12" CPEP W= 321.85 12" CPEP W= 330.41 RIM= 336.85 12" CPEP E= 314.67 >E' y -j 12 \CPEP N=302.54 CTR. -CH.= 305.23 12" CPEP W=310.90 CTR. CH.= 328.70 FIRE 1 `-" >j ;, I 12" CPEP W= 314.57 HYDRANT POWER �\ sr, t m STORM DRAIN MANHOLE (T2) RISER IA c RIM=313.98 PARCEL 326060-0000 ... •N:.... ,; 'j '7;f.+i, A 70 36" CMP 5=303.68 CATCH BASIN (Ty -� ;:r I z a W/ TREE HERITAGE VILLAGE CONDOMINIUM RIM=307.43 a a 12" CMP W=303.63 12" CMP E=303.24 *'i ' ?;t. TOP TREE=311.98 12" CMP W=463.24 6" CPEP N= 05.39 �C , ' o�U� OFFSITE BUILDING STORM DRAIN MANHOLE (T2) / '�+;;,• / RIM=313.87 12" CMP N= 304.40 '. 30 r`•: I < 0 12" CMP SE= 308.50 f f,✓ /CATCH BASIN (T1) '•":: T ?` ^� z RIM=307.45 8" CPM E=305.35 1.::A '• + N x 5p _ , " \ SSMH-A (CENTER STRUCTURE) yt ,• ", \ \ RIM=315.57 STORM DRAIN MANHOLE (T2) -1 G, p, - _ CTR CH-303.42 RIM=307.95 TB 12 CMP E-303.10 0 %: i'<• \ 12" CMP N=302.95 g^ 8" CMP W=303.45k,. C� ''�;. ,•'1.,..:.',::.:: ,y, P LEGEND CONSTRUCTION NOTES TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 14. 31 \ •;;`'icy \ ,-�i. I � :Y TELEPHONE RISER k I Know what's below. Call before you dig. 8/23/2024 SF HIGH VISIBILITY SILT FENCE LIMITS OF CLEARING AND GRADING OB OB TREE TO BE PROTECTED - ORANGE BARRIER FENCE ❑:: INLET PROTECTION OO STABILIZED CONSTRUCTION ENTRANCE O O -< < INTERCEPTOR SWALE WITH ROCK CHECK DAM SURVEYED: 4 PER CITY COMMENTS DAF 08/26/24 DESIGNED: DAF 3 PER CITY COMMENTS DAF 07/29/24 2 PER CITY COMMENTS DAF 05/21/24 DRAWN: TJW, FEM 1 PER CITY COMMENTS DAF 04/04/24 CHECKED: DAF NO. REVISION BY DATE APPR APPROVED: SCALE: 1 "=30' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY ID FLAG CLEARING LIMITS TO EXTENTS SHOWN ON THE PLAN. 2O HIGH VISIBILITY SILT FENCE PER DETAIL SHEET C2.1 OCONSTRUCTION ENTRANCE PER DETAIL SHEET C2.1 0 CATCH BASIN INSERT PER DETAIL SHEET C2.1 OINTERCEPTOR DITCH W / ROCK CHECK DAMS PER DETAIL SHEET C2.1 OTREE PROTECTION FENCE O7 MULCH SITE PER SWDM SECTION C.3.2 OVAULT TO BE USED TO STORE SEDIMENT -LADEN STORMWATER DURING CONSTRUCTION VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM CITY OF RENTON Planning/Building/Public Works Dept. 0) M Q0 MO�� t•J N LJ �, co a J ruRR ENOINEERING SERVICES, PLLC 4715142nd PI. SW #B, Edmonds, WA 98026 ph 206 890 8291 0 R-429004 I� IN COMPLIANCE WITH CITY OF RENTON STANDARDS =O DEVELOPMENT ENGINEERING z NJanders 09/16/2024 O P- W U Q DATE: J GRANT PLACE TOWNHOMES 11/21/23 a- 1600 GRANT AVE S RENTON, WA 98055 FlELDBOOK: PARCEL 2023059052 PAGE: DRAWING N0: 20069 � TESC PLAN SHEET: OF: r • ' C2.0 28 V