HomeMy WebLinkAboutR-429009CD 0 LU 7 30 15 0 30 60 SCALE: 1 INCH = 30 FEET EXIST STORM DRAINAGE STRUCTURE TABLE ID DESCRIPTION RIM ELEV PIPE INVERT STATION OFFSET 12" (W) LCPE IE=303.89 CB #2 TYPE I GRATE EL 307.56 12" (E) LCPE IE=303.89 9+92.54 12" (N) DRAINI.89 8.764E CB #3 TYPE I GRATE EL 309.41 12" (W) LCPE IE=305.00 9+80.14 8.685L CB #4 TYPE I GRATE EL 340.60 12" (NW) RCP IE=337.92 6+00.30 10.703L 12" (E) LCPE IE=286.71 12" (W) REINFORCED CONCRETE IE=286.61 EX SDMH-1 TYPE II -SOLID LID EL 294.51 12" (N) EX CMP IE=290.01 3+14.80 12" (NE) EX CMP IE=290.16 5.016E 12" (SE) EX CMP IE=287.21 12" (E) LCPE IE=302.54 10+09.06 EX. CB #1 TYPE I GRATE EL 306.95 12" (N) LCPE IE-302.54 10.824E 12" (NW) LCPE IE=341.60 5+45.00 EX.CB #6 TYPE I GRATE EL 345.08 12" (E) LCPE IE=341.60 14.654L EX.CB #7 TYPE I GRATE EL 354.82 12" (W) LCPE IE=349.02 1+18.16 0.970L 12" (E) LCPE IE=300.63 0+82.6312" EX.CB #8 TYPE I GRATE EL 303.51 (S) LCPE IE=300.63 9.047L 12" (E) LCPE IE=312.18 1+64.76 EX.CB #9 TYPE I GRATE EL 315.69 12" (W) LCPE IE=312.18 9.050L 12" (E) LCPE IE=315.99 2+51.50 EX.CB #10 TYPE I GRATE EL 319.95 12" (W) LCPE IE=315.99 9.019L 12" (E) LCPE IE=323.97 3+54.6312" EX.CB #11 TYPE I GRATE EL 327.12 (W) LCPE IE=323.97 9.096L 12" (W) LCPE IE=332.19 4+61.0812" EX.CB #12 TYPE I GRATE EL 335.01 (E) LCPE IE=332.19 8.799L 12" (SE) LCPE IE=336.82 4+99.46 EX.CB #13 TYPE I GRATE EL 340.48 12" (W) LCPE IE=336.82 8.262L 12" (E) LCPE IE=288.17 EX.CB #14 TYPE II-48" 0 GRATE EL 297.71 12" (SE) LCPE IE=288.37 0+50.85 12" (W) LCPE IE=288.17 16.247L 12" (SW) RCP IE=312.67 9+45.8212" EX.CB #15 TYPE I GRATE EL 317.65 (E) RCP IE=312.67 56.554R 12" (W) RCP IE=323.03 8+42.7112" EX.CB #16 TYPE I GRATE EL 325.70 (E) RCP IE=323.03 54.675R 12" (W) RCP IE=332.34 7+39.3712" EX.CB #17 TYPE I GRATE EL 335.01 (E) RCP IE=332.34 54.830R 12" (W) RCP IE=337.59 5+64.0312" EX.CB #18 TYPE I GRATE EL 341.06 (SE) RCP IE=337.59 32.526R 12" (W) LCPE IE=288.52 0+64.41 EX.SFMH#1 TYPE II-72" SOLID LID EL 300.76 12" (S) LCPE IE=290.82 9.834L NOTE: STORM FACILITIES HAVE BEEN INSTALLED UNDER AN EXPIRED PERMIT AND REFLECT AS -BUILT CONDITIONS. SURVEY IE AND RIM ELEVATIONS ARE PROVIDED FOR THE REFERENCE ONLY, USE STRUCTURES TABLE FOR THE PROPOSED FINAL ELEVATIONS. TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT: FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. EX.SFM EX.CB #14 RAISE EX. MH RI WITH ONE 2' SECTION I0 30' 30' EX 16LF 12" LCPE @ 2.2 \EX SDMH4--/ EX 34LF 12" LCPE @ EX 34LF 12" LCPE @ 40. 1. .4 nnnnnc+�n I �n��ln Know what's below. Call before you dig. GRASSCRETE SERVICE DRIVEWAY FOR STORM VAULT MAINTENANCE ASPHALT PAVEMENT CONCRETE SIDEWALK EX STORM DRAIN PIPE EX TYPE 1 CATCH BASIN EX TYPE 2 STORM DRAIN MANHOLE 8/23/2024 NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M. GRANT PLACE TOWNHOMES PER CITY COMMENTS PER CITY COMMENTS PER CITY COMMENTS PER CITY COMMENTS 4LF 12" LCPE @ 9.71 % CB #1 o F.'Tl"kqffi •. NOTE: THE UTILITIES HAVE BEEN PARTIALLY UPDATED TO REFLECT AS -BUILT CONDITIONS. ADDITIONAL AS -BUILT SURVEY REQIRED TO OBTAIN INVERT ELEVATIONS ON STORM AND SANITARY SEWER. PROPOSED IE AND RIM ELEVATION TAKES PRECEDENCE OVER SURVEY DATA. 87LF 12" LCPE @ 4.39% RELOCATE EX. STORM PIPING FROM EX.CB#1 TO CB#5 SSMH-A (CENTER STRUCTURE) TRIM=315.57 CTR CH.=303.42 STORM DRAINAGE NOTES ALL RIM ELEVATIONS CALLOUTS SHOWN IN THE DEVELOPMENT ARE EXISTING OELEVATION. THE FINAL RIM ELEVATIONS ARE SHOWN IN THE STRUCTURE DRAINAGE TABLE ON THIS PAGE. PORTION OF PARCEL 202305-9013 PARCEL 326060-0000 HERITAGE VILLAGE CONDOMINIUM ACO SLOTTED STEEL GRATE W/QUICKLOCK ASS'Y. TACK COAT FACE OF --- CUT AND EACH COURSE 4" HMA 6" COARSE FILL #3 REBAR CONTINUOUS (TYP) SEE STORM PLAN AND/OR UTILITY PLAN FOR CHANNEL INVERTS/SLOPE(S). #3REBAR@6"OC ACO FRAME MESH STEEL 12" TRENCH DRAIN K300 CLASS B POUR IN PLACE CONC. BASE 51/2 SACK MIX 4000 PSI @ 28 DAYS I. DMOF- OTVILL DC r-VUTCCU AGAINST COMPETENT NATIVE MATERIAL OR STRUCTURAL FILL. NEW STRUCTURAL FILL, COMPACT 2. ALTERNATE TRENCH DRAIN (ASTM D1557) SPECIFICATION MAY BE SUBMITTED NOTE: ALL STORM SYSTEM FACILITIES UPSTREAM EX.SDMH-1 ARE PRIVATE. SURVEYED: DAF 08/26/24 DESIGNED: DAF DAF 07/29/24 DAF 05/21 /24 DRAWN: TJW, FEM DAF 04/04/24 CHECKEDDAF BY DATE I APPR I APPROVED: FOR REVIEW AND APPROVAL. FORMED IN PLACE TRENCH DRAIN NTS SCALE: 1 "=30' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M Adoftk tuCITY OF RENTON Planning/Building/Public Works Dept. CONSTRUCTION NOTES 1O CONTROL STRUCTURE - SEE DETAIL SHEET C4.3 OWATER QUALITY CONTROL STRUCTURE - SEE DETAIL SHEET C4.3 EX STORMWATER DETENTION VAULT - 90.1' X 40.8' - SEE DETAIL SHEET C4.3 O 4" PERF PVC SDR 35 FOOTING DRAIN 4O O6" PVC ROOF DRAIN @ 2% MIN (TYP.) INSTALL STORM FILTERS AFTER CLEANING ALL CATCH BASINS AND PIPES O 43LF 12" LCPE @ 10.65% One meter channel Outlet Product Outlet size (Sch.40) Invert Depth GPM CFS B Bottom outlet - K3-00 8" round 11.81" 1 748 1.67 �FIIIJIIRR ENOINEERING vNERVICES, PLLC 4715142nd PI. SW #B, Edmonds, WA 98026 ph 206 890 8291 Cfl O O N �1 u SEE \SEPARATION NOTES 00 N o O I o O FEX.CB #77 O P o IW 0 N 0 � Q co, � C6 J Z) w o � U J z Qf Q a - T O O O C'0 N I..L r �---.---.--- � R-429009 w IN COMPLIANCE WITH CITY OF RENTON STANDARDS O SURFACE WATER UTILITY t � J Farah 09/03/2024 ' DEVELOPMENT ENGINEERING Z NJanders 09/16/2024 0 GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 DRAINAGE CONTROL PLAN LLI U Q DATE: 11/21/23 J FlELDBOOK: PAGE Z DRAWING NO: 20069 cr SHEET: OF, C4.0 28 -/