TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT:
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
FLOC
IF ---
INLET --
e /
TOP SLAB ACCESS
SEE FRAME AND
COVER DETAIL
CONTRACTOR TO GROUT TO
FINISHED GRADE
GRADE
RING/RISERS
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
PLAN VIEW
STANDARD OUTLET RISER
FLOWKIT: 42A
_ OUTLET
SUMP
A
rQJOUTLET
6'-0" [018291 I.D.
MANHOLE STRUCTURE
�(OT-0" [021341) O.D.
J a I
FLOATABLES
STORMFILTER BAFFLE
CARTRIDGE Q
U
w
Q c"
W 04
z 00
INLET PIPE --/ l a I I I I I � I l�
Know what's below.
Call before you dig.
a -
FLOW KIT
0 j z
OUTLET SUMP
U w
HDPE OUTLET RISER
z�
—O
SECTION A -A
= _ °
The Stormwater Management
StormFilter0
THIS PRODUCT MAY BE PROTECTED BY ONE OR MORE OF THE FOLLOWING
U.S. PATENTS: 5,322,629; 5,524,576; 5,707,527; 5,985,157; 6,027,639; 6,649,048;
RELATED FOREIGN PATENTS, OR OTHER PATENTS PENDING.
8/23/2024
STORMFILTER DESIGN NOTES
STORMFILTER TREATMENT CAPACITY IS A FUNCTION OF THE CARTRIDGE SELECTION AND THE NUMBER OF CARTRIDGES. THE STANDARD MANHOLE
STYLE IS SHOWN WITH THE MAXIMUM NUMBER OF CARTRIDGES (7). VOLUME SYSTEM IS ALSO AVAILABLE WITH MAXIMUM 7 CARTRIDGES.
06-0" [1829 mm] MANHOLE STORMFILTER PEAK HYDRAULIC CAPACITY IS 1.5 CFS [42.5 Us]. IF THE SITE CONDITIONS EXCEED 1.5 CFS [42.5 L/s] AN
UPSTREAM BYPASS STRUCTURE IS REQUIRED.
CARTRIDGE SELECTION
CARTRIDGE HEIGHT
27" [686 mm]
18" [458 mm]
LOW DROP
RECOMMENDED HYDRAULIC DROP (H)
3.05' [930 mm]
2.3' [700 mm]
1.8' [550 mm]
SPECIFIC FLOW RATE (gpm/sf) [L/s/m2]
2 [1.30]
1.67* [1.08]
1 [0.65]
2 [1.30]
1.67* [1.08] 1 [0.65]
2 [1.30]
1.67* [1.08]
1 [0.65]
CARTRIDGE FLOW RATE (gpm) [L/s]
22.5 [1.42]
18.79 [1.19]
11.25 [0.71]
15 [0.95]
12.53 [0.79] 7.5 [0.44]
10 [0.63]
8.35 [0.54]
5 [0.32]
* 1.67 gpm/sf [1.08 L/s/m2] SPECIFIC FLOW RATE IS APPROVED WITH PHOSPHOSORBR (PSORB) MEDIA ONLY
FRAME AND COVER
(DIAMETER VARIES)
N.T.S.
SITE SPECIFIC
DATA REQUIREMENTS
STRUCTUREID
SFMH#1
WATER QUALITY FLOW RATE (cfs) [L/s]
0.0266 CFS
PEAK FLOW RATE (cfs) [L/s]
0.1153 CFS
RETURN PERIOD OF PEAK FLOW (yrs)
2
CARTRIDGE HEIGHT (SEE TABLE ABOVE)
18"
NUMBER OF CARTRIDGES REQUIRED
7 PSC
CARTRIDGE FLOW RATE
10.0167 CFS
MEDIA TYPE (PERLITE, ZPG, PSORB)
I ZPG
PIPE DATA:
I.E.
MATERIAL
DIAMETER
INLET PIPE #1
(S) 290.82
LCPE
12"
INLET PIPE #2
OUTLET PIPE
(W) 288.59
LCPE
12"
RIM ELEVATION 300.59
ANTI -FLOTATION BALLAST
WIDTH
HEIGHT
6"
12"
NOTES/SPECIAL REQUIREMENTS:
* PER ENGINEER OF RECORD
GENERAL NOTES
1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE.
2. DIMENSIONS MARKED WITH () ARE REFERENCE DIMENSIONS. ACTUAL DIMENSIONS MAY VARY.
3. FOR SITE SPECIFIC DRAWINGS WITH DETAILED VAULT DIMENSIONS AND WEIGHTS, PLEASE CONTACT YOUR CONTECH ENGINEERED SOLUTIONS
LLC REPRESENTATIVE. www.ContechES.com
4. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS
DRAWING.
5. STRUCTURE SHALL MEET AASHTO HS-20 LOAD RATING, ASSUMING EARTH COVER OF 0' - 5' [1524 mm] AND GROUNDWATER ELEVATION AT, OR
BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS SHALL
MEET AASHTO M306 AND BE CAST WITH THE CONTECH LOGO.
6. FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL
BE 7-INCHES [178 mm]. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS.
7. SPECIFIC FLOW RATE IS EQUAL TO THE FILTER TREATMENT CAPACITY (gpm) [L/s] DIVIDED BY THE FILTER CONTACT SURFACE AREA (sq ft)[mz].
8. STORMFILTER STRUCTURE SHALL BE PRECAST CONCRETE CONFORMING TO ASTM C-478 AND AASHTO LOAD FACTOR DESIGN METHOD.
INSTALLATION NOTES
A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE
SPECIFIED BY ENGINEER OF RECORD.
B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE.
C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE.
D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S).
E. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. STORMFILTER EQUIPPED WITH A DUAL DIAMETER HDPE
OUTLET STUB AND SAND COLLAR. IF OUTLET PIPE IS LARGER THAN 8 INCHES [200 mm], CONTRACTOR TO REMOVE THE 8 INCH [200 mm] OUTLET
STUB AT MOLDED -IN CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR.
F. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF.
SURVEYED: SCALE:VEffn_
r
4 PER CITY COMMENTS DAF 08/26/24 1 a— —30 HORIZONTAL- N D 1983/1991
DESIGNEDDAF
3 PER CITY COMMENTS DAF 07/29/24
2 PER CITY COMMENTS DAF 05/21/24 DAWN'
TJW, FEM ONE INCH DATU M
1 PER CITY COMMENTS I DAF 1 04/04/24 CHECKED:
AT FULL SCALE
DAF IF NOT ONE INCH
NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY
CITY OF
RENTON
Planning/Building/Public Works Dept.
FURR
:±;�:1111VIM1%
NEERING
PLLC
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
R-429013
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
NJanders 09/16/2024 '
GRANT PLACE TOWNHOMES
1600 GRANT AVE S RENTON, WA 98055
PARCEL 2023059052
STORMFILTER DETAILS
DATE:
11/21/23
FIELDBOOK:
PAGE:
20069
SHEET: OF,
C4.4 28