11" 2" 4" 6", 12", OR 24"
ONE #3 BAR HOOP FOR 6" HEIGHT
INCREMENT (SPACED EQUALLY),
SEE NOTE 1
RECTANGULAR ADJUSTMENT SECTION
S�6
�1a0
E
26 5
N
#/3 BAR EACH CORNER
SFF 22,
\OTFT
#3 BAR EACH SIDE �Y
#3 BAR EACH WAY v
PRECAST BASE SECTION
#3 BAR HOOP
#3 BAR EACH
CORNER 18" MIN.
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
PUBLIC WORKS
FI` DEPARTMENT
1 251;4"
29 1 /4"
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR PLAIN
12"
CONCRETE
ALL METAL PIPE
15"
CPSSP"
12"
STD. SPEC. 9105.20
SOLID WALL PVC,
STD. SPEC. 9-05.12(1)
15"
PROFILE WALL PVC,
STD. SPEC. 9.05.12(2)
15"
" CORRUGATED POLYETHYLENE STORM
SEWER PIPE
NOTES:
1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN
IN THE PRECAST BASE SECTION, FIBERS (PLACED IN
ACCORDANCE WITH STANDARD SPECIFICATION
9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF
0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH
THE MINIMUM REQUIRED REBAR SHOWN IN THE
ALTERNATIVE PRECAST BASE SECTION. WIRE MESH
SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN
ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN
THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH
HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER
FOOT MAY BE USED.
2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER
THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS
OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5"
MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE
OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED,
FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-04.3.
3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO
THE LOWEST PIPE INVERT SHALL BE 5 FEET.
4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE
FLANGE DOWN.
5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED
FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF
1 H:24V OR STEEPER.
6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE
PRECAST BASE SECTION.
7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE
INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR
NON -SHRINK APPLICATIONS IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-20.3(2).
8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN
MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE
AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND
FRAMES.
9. MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURER'S DIRECTIONS.
1TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
0. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH.
11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
REMAIN VISIBLE UPON COMPLETION.
UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NTS)
STD. PLAN - 200.00
[PIRRED:
CATCH BASIN TYPE 1 GAZ 9/28/2018 1
PvbbAdmmiso- DATE
BOLT -DOWN HOLE (TYP.) - 5/8",
11 NC, SEE DETAIL AND NOTE 2
TOP
RECESSED ALLEN
HEAD CAP SCREW
5/8" - 11 NC x 2"
GRATE
FRAME
SECTION BOLT -DOWN DETAIL
SEE NOTE 2
24 1 /4"
�\
SECTION A
SEE DETAIL _ ISOMETRIC VIEW
7/8" 4"
1/8" �
3/4" \\
' 11/4" ` NOTES:
1. THIS FRAME IS DESIGNED TO ACCOMMODATE 20" x 24" GRATES OR COVERS,
4 1l2" SEE STANDARD PLANS 204.10, 204.20, AND 204.30.
I\ 1 5/8" I 2. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND
/ COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE
1 5,'8" FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS.
THE FRAME SHALL ACCEPT THE &W-1 1 NC x 2"ALLEN HEAD CAP
3/4" BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OFCREW BY
\ BOLT -DOWN HOLES VARIES BY MANUFACTURER.
�21/2"�
3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL
\ DETAIL / REQUIREMENTS.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 204.00
• PUBLIC WORKS APPROVED:
DEPARTMENT RECTANGULAR FRAME "sp
Martinn P 1astucha 0/19/2022
UR
Nkw d]S1k,Ad i-t
Pubiir Wwks Adminiscrato, DATE
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT:
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
Know what's below.
Call before you dig.
NE 1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N.7 R. 05 E, W.M.
2' 11-1/2"
4-3/4" 2'2" 4-3/4"
rr
4-1/2" ------
1 r
I I
I
2' 7" 1' 1 D" I I
I I
I I
l
4-1/2" ------
GRANT PLACE TOWNHOMES
CONVERSION RISER
ONE #4 BAR HOOP
#4s EACH SIDE OF OPENING
ADJUSTMENT RINGS 6"
CONVERSION RISER 8"
6"
3' 6-1/4"
I I
1 f 1
I I 11
I I I I I I
I I I 1 1 I 5' 5-3i4'
11 I 1 I
I I I
jL 3 J j j l
1 7 1 I I I
I I I
L--------J
5-112"
�2'9-1/2'� 2'5"------
DEPTH: 3.52' TO IE OUT
UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NTS)
STD. PLAN - 200.40
� PUBLIC WORKS PPR
MD
CONVERSION RISER URDEPARTMENT GAZ 9/28/2018 1
Public Works Admmistmto, DATE
24" '
BOLT -DOWN SLOT, 3/4•
SEE DETAIL AND
2 1/2" DIA. HOLE NOTE 1 1 1/4"
20" A U 518"
o T
O�O�OG
BOLT -DOWN SLOT DETAIL
OQ�d �Q�Q SEE NOTE 1
�3"1 TOP ern
ISOMETRIC
4 3/4" 1 1/2"
1 5/8i
R39% SEE NOTE 2
SECTION A
SECTION B
R26", SEE NOTE 2
5„
NOTES:
3 1/2
r 3/4,,
1 5/81•
1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES,
GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED.
PROVIDE TWO HOLES IN THE FRAME THAT ARE
VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS.
THE FRAME SHALL ACCEPT THE 518"-11 NC x 2" ALLEN
4"
HEAD CAP SCREW BY BEING TAPPED, OR OTHER
3/4" DIA. HOLE
APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES
VARIES BY MANUFACTURER.
1/2" DIA. HANDLE
1 1/2"
2. ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN
LIEU OF THE RIB DESIGN.
SECTION C
3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR
ADDITIONAL REQUIREMENTS.
4. FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD
PLAN 204.00.
UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS)
AOMSTD. PLAN - 204.10
� PUBLIC WORKS
RRECTANGULAR SOLID METAL COVER D 9/28/2018 1
�DEPARTMENT GAZ
PvbrcwAammisnamr DATE
8/23/2024
4 PER CITY COMMENTS
3 PER CITY COMMENTS
2 PER CITY COMMENTS
1 PER CITY COMMENTS
NO. REVISION
CATCH BASIN FRAME AND VANED
GRATE PER STD. PLAN 204.00
RECTANGULAR OR CIRCULAR ADJUSTMENT
SECTION (TWO SECTIONS MAX.)
MORTAR, (TYP.), SEE NOTE 5
4" MIN.
28" MAX. 16" MAX. FLAT SLAB TOP
48", 54", 60", 72", 84'
96", 120" OR 144" SEE NOTE 6, TYP.
16 MAX. FOR
MAINTENANCE STEPS OR
LADDER
12" (TYP.)
T 1"MIN.
12" MAX.
RING 24" 2.5" MAX. REINFORCING STEEL, (TYP.)
MIN.
12• GRAVEL BACKFILL FOR PIPE ZONE
12" BEDDING PER WSDOT STD.
SPECIFICATION SECTION 9-03.12(3)
6 6"
SEPARATE BASE INTEGRAL BASE
PRECAST PRECAST WITH RISER
NOTES:
1. NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS.
2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE
SLOPED TO FACILITATE CLEANING.
3. THE RECTANGULAR FRAME AND GRATE MUST BE
INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE
CAST INTO THE ADJUSTMENT SECTION.
4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2"
MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP
BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE
PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH
JOINT MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9.04.3.
5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET
IN MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9.04.3.
6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE
CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE
ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO
AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF
THE SAME MATERIAL AS THE CONNECTING PIPE.
7. MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURER'S DIRECTIONS.
8. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH.
9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
REMAIN VISIBLE UPON COMPLETION.
PUBLIC WORKS
DEPARTMENT
ISOMETRIC
24"
7 OR 8 EQUAL SPACES
1 DIRECTION OF FLOW
T �
1 5/8" MAX. J
SECTION A
CATCH BASIN DIMENSIONS
CATCH BASIN
DIAMETER
MIN. WALL
THICKNESS
MIN. BASE
THICKNESS
MAXIMUM
KNOCKOUT SIZE
MINIMUM
DISTANCE
BETWEEN
KNOCKOUTS
48"
4"
6"
36"
8"
54"
4.5"
8"
42"
8"
60"
5"
8.1
48"
8"
72"
6"
8"
60"
1 12"
84"
8"
12"
1 72'
1 12"
96"
8"
12"
1 84"
1 12"
120"
10"
12"
96"
12"
144"
12"
12"
108"
12"
PIPE ALLOWANCES
CATCH BASIN
PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER
DIAMETER
CONCRETE
ALL METAL
CPSSP'
SOLID WALL
PVC
PROFILE WALL
PVC,
48"
24"
30"
24"
30"
30"
54"
30"
36"
30"
36"
36"
60"
36"
42"
36"
42"
42"
72"
42"
54"
42"
48"
48"
84"
54"
60"
54"
48"
48"
96"
60"
72"
60"
48"
48"
120"
66"
84"
60"
48"
48"
144"
78"
96"
60"
48"
48"
'CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20)
2 STD. SPEC. 9-05.12(1)
a STD. SPEC. 9-05.12(2)
CATCH BASIN TYPE 2
UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NT
STD. PLAN - 201.00
6 PR-69PE:
GAZ 9/28/2018 1
vvmra works Aamm+snaror DATE
I
OLT-DOWN SLOT, 1 1/2"
EE DETAIL AND
OTE 1
3/4"
1 1.14"
I �
5/8"
I TI
BOLT -DOWN SLOT DETAIL
SEE NOTE 1
LETTERING
V.
3"
5"
5"
20"
5"
SECTION B
NOTES:
1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND
COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN
THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR
COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN
HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED
MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY
MANUFACTURER.
2. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL
REQUIREMENTS.
3. FOR FRAME DETAILS, SEE STANDARD PLAN 204.00.
UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS)
STD. PLAN - 204.20
PUBLIC WORKS
R�
®�
U 1� DEPARTMENT
RECTANGULAR VANED GRATE
JP1'11-D
GAZ 9/28/2018
G
PPbli< ks Administrator DATE
SURVEYED:
DAF
08/26/24
DESIGNED: DAF
DAF
07/29/24
05/21 /24
DRAWN:DAF TJW, FEM
DAF
04/04/24
CHECKED:
DAF
BY
DATE
APPR
APPROVED:
SCALE:
1 "=30'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
CITY OF
RENTON
Planning/Building/Public Works Dept.
SEE NOTE 4
CLEAN SURFACE AND BOTTOM AREA.
PROVIDE UNIFORM CONTACT. THE SURFACE
AREA OF THE BASE SECTION MUST BE
MORTARED TO THE BOTTOM AREA OF THE
ADJUSTMENT SECTION ADJUSTMENT SECTION
I
I
I
I
I
I
I
I
NOTES:
1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER,
DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO
MORTAR IN PLACE IN ACCORDANCE WITH WSDOT/APWA STANDARD SPECIFICATION 7-05.3.
2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED.
3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT.
4. ONLY BY APPROVAL OF THE CITY, THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR Y2 BOND.
5. BASE SECTION SHALL BE SEALED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH MORTAR.
6. MORTAR SHALL MEET THE REQUIREMENTS OF WSDOT/APWA STANDARD SPECIFICATION 9-04.3.
7. PICK / LIFTING HOLES ARE TO BE GROUTED WATER TIGHT, USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-20.3(2).
8. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS.
9. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF
SUFFICIENT LENGTH.
10. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION.
UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NTS)
AOISTD. PLAN - 202.00
�• PUBLIC WORKS PRO
Rt
DEPARTMENT CATCH BASIN INSTALLATION (GAZ 9/28/2018 1
G DATE
Public WPrks Administrator
co
C)
O
N
,
LJ
M
N
Q
J
co
T
C)
O
O
co
rum
ENOINEERING
SERVICES, P=
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291 W
R-429014
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
DEVELOPMENT ENGINEERING Z
NJanders 09/16/2024 0
I-
W
U
Q
DATE: J
GRANT PLACE TOWNHOMES 11/21/23
1600 GRANT AVE S RENTON, WA 98055 FIELDBOOK:
PARCEL 2023059052 PAGE:
DRAWING NO: Z
20069 cr
DETAILS SHEET: OF: