Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutzR-4290setm
8
w
Q
z
J
L,
LIGHT POLE SCHEDULE AS A CONDITION OF
APPROVAL APPLICANT NE 1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N.7 R. 05 E W. M.
Q POLE STATION\ MOUNTING HEIGHT ARM LENGTH SHALL SUBMIT THE 1 >
N ID OFFSET (FT) (FT) VOLTAGE WATTAGE LUMINAIREIPOLE TYPE PROPOSED STREET LIGHT POLE AND LUMINAIRE TO GRANT PLACE TOWNHOMES
ARTERIAL STREET DECORATIVE THE DEVELOPMENT
1 4+41.53 STREET- 35.5' STREET-8' STREET SCALE: 105 =� ENGINEERING PROJECT
TBD (24.92 M PEDESTRIAN - 16.5' PEDESTRIAN-4' TBD PED. SCALE: 34 LUMINARE POLE AS PER STD. ; MANAGER FOR REVIEW
PLAN-117.1, 119, 120, 121 = AND APPROVAL PRIOR TO
0
INSTALLATION.
W
PROPOSED KEYSTONE WALL (TYP)
WITH FENCE ON TOP. FENCE HEIGHT
MEASURED FOM THE BOTTOM OF RETAINING
J WALL SHALL NOT EXCEED 6'
TRACT B
(INGRESS, EGRESS, UTILITY,
AND OPEN SPACE)
TRACT A
PROPOSED ASPHALT RAMP �, (INGRESS, EGRESS, UTILITY,
1 ��,� PORTION OF PARCEL 202305-901.- AND OPEN SPACE)
RAIL ON THE RET. WALL ¢ GARBAGE COLLECTION 20' PRIVATE ALLEY ACCESS
o TOP EDGE VAULT MAINTENANCE AREA (TYP)
+ 30' GRATE & PUBLIC UTILITY EASEMENT N89°09'24"E
30' '`' - 1 - - - - - SE GRANT IRCLE
W- - - - -
O AC!ESS�/
-17
e'. 1• BUILDING #1 BUILDING #2 BUILDING #3
..,/ :' a:' ",.:°;:d l . 1STFF= is T= 1ST FF= 1STFF=
\ _ , \ �` 1ST FF= 1ST FF= 1ST FF= 1ST FF= 1ST FF= 1ST FF= 1ST FF= 1ST FF= 1ST FF= I •r' ;;
1 ITY EASEMENT I 316.73 317.77 318.35 318.91 320.0 I "' i' i ° 331.59 333.31 333.44 334.94
O �� 324.61 325.70 325.95 327.35
REPLACE EXISTING ' �� I 1' 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF=
0 CURB AND GUTTER �� ®- �\ �� \ \ I 330.08 333.77 335.27 335.27 336.77 341.57 343.03 343.03 344.56
\ 326.08 328.08 328.08 328.08
W \TRAGTA�
U �0'` 2 ,; {; 3'L NDSCAPE ° :\ \ (INGRESS,
SETBACK \ REGRESS , UTILITY,v \ 10' STORM DRAINAGE EASEMENT /
J
I
Q f,, AND
d^•
• d°
SPACE) v \ ►
"'T` 1.5'RO FDICATION - --- --- ---- ----
� \ � I: ' " a. ' '"'�' " = �f�:' PROPOSED CROSSWALK (TYP)
EXISTING DETENTION \ a „ _ -_ - - - - - d VAUL - - - - - ,
44
Z eye' \ \ d'••. BUILDING#7 IBU1LD1ING#6
Q °� \ 10 \ d
,•r.,. � c \ \� - \� \ ••: BUILDING #8 .•, 1ST FF= 1ST FF= 1ST FF= 1ST FF= 1ST FF= 1ST FF= 1ST FF= 1ST FF=
:5 330.35 331.80 331.80 333.47
\ I 1ST FF= 1ST FF= 1ST FF= 1ST FF= 1ST FF= 322.61 323.80 324.02 325.81
v 2ND FF= 2ND FF= 2ND FF= 2ND FF= � 314.90 315.92 316.10 316.60 317.57 2ND FF= � 2ND FF= 2ND FF= 2ND FF=
�: ' \ I 333.95 333.95 337.00
I' 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF= 331.85 1 " �'� J 340.19 341.55 341.55 343.08 �
324.73 325.92 325.92 325.92 327.'
I
L_ -
30 15 0 30 60
SCALE: 1 INCH = 30 FEET
WOOD FENCE ALONG
NORTH PROPERTY LINE
onYi�Yi�li\`:I�Yiii�iY��Yi�Yi�liiil�lii��i
III
�
I,
,
e�357.98
D
.,1
:ILdc'o
;
•
III
..
1
Dlowiaw�
�
•
•
_
NO---
1
I
•
:::� �'
fA�dll
�
•
�iJl�is�aa�.
BUILDING #5
e° I
N �
1ST FF=
1ST FF=
1ST FF=
1ST FF=
1ST FF=
J
ae I
Lr)� �
_j SCALE: 1 "=2000'
348.25
349.53
350.87
352.46
353.96
2ND FF=
2ND FF=
2ND FF=
2ND FF=
2ND FF=
364.01
I
z
LEGAL DESCRIPTION:
357.99
359.48
360.98
362.52
I
Q
!I NIN WE
1° I\ t-.I�� �i� . uea.�-�. � -�n� � Ci �ii�� i�iLr L� ,� i�l--.�C�C. -��a :i-�w•ICJ��i���R`�..-i ra�� � \�` �� I
� ` / ;lam,-P-��------���' :�•: �-�jn� ■- e' - �Id�A� -' � `��I! I�
LOT AREA TABLE
1
1,076 SF
2
846 SF
3
1,025 SF
4
846 SF
5
1,076 SF
6
1,076 SF
7
846 SF
8
1,025 SF
9
1,076 SF
10
1,076 SF
11
846 SF
12
1,025 SF
13
1,076 SF
14
1,083 SF
15
851 SF
16
1,032 SF
17
851 SF
18
1,083 SF
19
1,083 SF
20
851 SF
21
1,032 SF
22
851 SF
23
1,083 SF
24
1,076 SF
25
846 SF
26
1,025 SF
27
1,076 SF
28
1,076 SF
29
846 SF
30
1,025 SF
31
1,076 SF
32
1,076 SF
33
846 SF
34
1,025 SF
35
846 SF
36
1,076 SF
TOTAL
35,630 SF
MIN.
846 SF
MAX.
1,083 SF
AVG.
990 SF
9+08+00
;- VAULT ACCESS 00
------ 0
- - - - - - - - -
ENTRANCE ------------------------- i N
SE GRANT CIRCLE
CONNECT TO 20' PRIVATE ALLEY ACCESS LINEAR DRAIN
PROPOSED MAILBOXES (TYP) &PUBLIC UTILITY EASEMENT
Ok6� s d ° ®� EXIST SEWER WOOD FENCE ALONG TO THE SEWER
PROPOSED LINEAR DRAIN SOUTH PROPERTY LINE
NO PARKING - FIRE LANE SIGN (TYP)
PROPOSED SEWER PARCEL 326060-000U
REMOVE EX. HERITAGE VILLAGE CONDOMINIUM
WATER METER r';. c `s• �d 15' SEWER EASEMENT
AND
TO BE RFCnRnFn
CAP AT THE MAIN
BY CITY FORCES
PROPOSED SEWER MH
v'
�gs
TBM
PROPOSED SEWER ?:
0
FIRE SPLINKERS:
FIRE SPLINKERS ARE REQUIRED TO BE INSTALLED
ON BUILDINGS WITH 5 UNITS: BUILDING 1, 4,5 AND 8
AS PER NFPA 13 AND IBC2021
TRACT AREA TABLE
TRACT A
19,084 SF
0.44 AC
TRACT B
12,476 SF
0.29 AC
TRACT C
2,595 SF
0.06 AC
TOTAL
34,155 SF
0.78 AC
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
Know what's below.
Call before you dig.
PROPOSED SEWER MH
CONNECTION TO EXISTING
CLIENT/ DEVELOPER: GEOTECH:
SATWANT SINGH
PHIL HABERMAN
15 S. GRADY WAY, SUITE 527
COBALT GEOSCIENCES, LLC
RENTON, WA 98057
P.O. BOX 82243
pmvrsingh@gmail.com
KENMORE, WASHINGTON 98028
www.cobaltgeo.com
CIVIL ENGINEER:
ARBORIST:
DEAN FURR, P.E.
FURR ENGINEERING SERVICES
SHOFFNER CONSULTING4715
PLLC
1015 TENTH ST.
4715 142ND PL SW UNIT#B
MUKILTEO, WA 98275
EDMONDS, WA 98026
(206) 755-9407
(206) 890-8291
tony@tonyshoffner.com
furrengineering@gmail.com
LANDSCAPE:
SURVEYOR:
TIM GRIFFIN
TYEE SURVEYORS
10007 GREENWOOD AVE. N
SEATTLE, WA 98133
PHONE: (206) 525-3660
PROPOSED LEGEND
A-\ �\ GRASSCRETE ACCESS
ASPHALT PAVEMENT
" A. CONCRETE PAVEMENT
PROPERTY BOUNDARY
- - - - - - - EASEMENT LINE
ROW DEDICATION
8/23/2024
TINA VINCENT, PLA, ASLA
P.O. BOX 1744
EDMONDS, WA 98020
PHONE: (206) 913-9216
tina@vindesigngrp.com
TRAFFIC:
AARON VAN AKEN, P.E.
HEATH AND ASSOCIATES, INC.
PO BOX 397
PUYALLUP, WA 98371
253-770-1401
avanaken@heathtraffic.com
4 PER CITY COMMENTS
3 PER CITY COMMENTS
2 PER CITY COMMENTS
1 PER CITY COMMENTS
NO. REVISION
SITE INFORMATION:
ADDRESS:
PARCEL NUMBER:
ZONING:
PARCEL AREA:
DISTURBED AREA:
EXISTING IMPERVIOUS AREA:
GROSS NEW IMPERVIOUS AREA:
NET NEW IMPERVIOUS AREA:
BUILDING AREAS:
BUILDING 1
3,284 SF
BUILDING 2
2,723 SF
BUILDING 3
2,723 SF
BUILDING 4
3,284 SF
BUILDING 5
3,284 SF
BUILDING 6
2,723 SF
BUILDING 7
2,723 SF
BUILDING 8
3,284 SF
TOTAL
24,028 SF
BUILDING COVERAGE:
UTILITY PURVEYORS:
WATER
SEWER
STORMWATER
ELECTRIC
GAS
GARBGE
COMM
ADDITIONAL NOTES:
504-1582 SE GRANT CIRCLE
202305-9052
RM-F
92,051 SF (2.11AC)
89,451 SF (2.05 AC)
3,900 SF (0.09 AC)
58,866 SF (1.35 AC)
54,966 SF (1.26 AC)
26%
CITY OF RENTON
CITY OF RENTON
CITY OF RENTON
PUGET SOUND ENERGY
PUGET SOUND ENERGY
REPUBLIC SERVICES
CENTURYLINK
1. 6" VERTICAL CURB SHALL BE INSTALLED BETWEEN UNIT LOT DRIVEWAY
AND ABUTTING LANDSCAPED AREAS.
2. ALL TRACTS (UTILITY, DRAINAGE, SHARED AREAS, OPEN SPACES) SHALL
BE PLACED WITHIN SEPARATE TRACTS THAT WOULD BE OWNED AND
MAINTAINED BY THE HOMEOWNER'S ASSOCIATION.
3. ALL PRIVATE OPEN SPACE AREAS ATTRIBUTED TO EACH INDIVIDUAL
DWELLING UNIT SHALL BE LOCATED ON THE SAME UNIT LOT AS THE
DWELLING UNIT.
SURVEYED:
DAF
08/26/24
DESIGNEE DAF
DAF
07/29/24
DAF
05/21 /24
DRAWN
TJW, FEM
DAF
04/04/24
CHECKED
BY
DATE
APPR
I APPROVED:
SCALE:
1 "=30'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
I
- - - - l TRACT B AN UNDIVIDED ON -HALF INTEREST IN THE FOLLOWING DESCRIBED PROPERTY:
(INGRESS, EGRESS, PORTION OF THE NORTHEAST QUARTER OF THE SOUTHWEST QUARTER OF
UTILITY, AND OPEN SECTION 20, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., IN KING COUNTY, WASHINGTON,
%.. SPACE)
N89°09 29 E 115.73 - DESCRIBED AS FOLLOWS:
TRACT C BEGINNING ON THE EAST LINE OF SAID SUBDIVISION AT A POINT WHICH IS
- TREE PRESERVATION - - - - - - SOUTH 00°08'49" WEST 475.79 FEET FROM THE NORTHEAST CORNER THEREOF;
THENCE NORTH 00°08'49" EAST 158.00 FEET;
THENCE WEST PARALLEL WITH THE NORTH LINE OF SAID SUBDIVISION 654.50 FEET;
THENCE SOUTH 26'18'57" EAST TO THE INTERSECTION WITH A LINE EXTENDING
WESTERLY THROUGH THE SAID POINT OF BEGINNING AND PARALLEL WITH THE
SPLIT RAIL FENCE NORTH LINE OF SAID SUBDIVISION;
ON TREE PRESERVATION AREA THENCE EAST ALONG SAID EXTENDED LINE TO THE POINT OF BEGINNING;
EXCEPTION THEREFROM A STRIP OF LAND 30 FEET WIDE, PARALLEL WITH AND
ADJOINING THE WESTERLY LINE OF SAID TRACT, FOR ROAD PURPOSES;
ING INDEX SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON.
TAX PARCEL # 2023059052
DRAWING
C1.0
COVER SHEET
C1.1
CONDITIONS OF APPROVAL
C1.2
NOTES
C2.0
TESC PLAN
C2.1
TESC NOTES AND DETAILS
C3.0
GRADING PLAN
C3.1
DETAILS
C3.2
DETAILS
C3.3
DETAILS
C4.0
DRAINAGE PLAN
C4.1
ROAD AND STORM PROFILES
C4.2
VAULT PLAN AND DETAILS
C4.3
VAULT DETAILS
C4.4
STORMFILTER DETAILS
C4.5
DETAILS
C4.6
DETAILS
C4.7
DETAILS
C5.0
SEWER PLAN
C5.1
SEWER PROFILES
C5.2
SEWER DETAILS
C5.3
SEWER DETAILS
C6.0
WATER PLAN
C6.1
WATER PROFILES
C6.2
WATER DETAILS
C6.3
WATER DETAILS
C7.0
HORIZONTAL CONTROL, SIGNAGE, AND STRIPING PLAN
C8.0
TREE RETENTION PLAN
C9.0
FIRE GATES DETAIL
BOUNDARY & TOPOGRAPHIC SURVEY (2 SHEETS)
L1.1
TREE RETENTION PLAN
L1.2
TREE RETENTION PLAN
L3.1
CONCEPTUAL LANDSCAPE PLAN
L3.2
CONCEPTUAL LANDSCAPE PLAN
L3.3
OPEN SPACE PLAN
L3.4
OPEN SPACE PLAN
L3.5
PLANTING & SITE DETAILS
L3.6
PLANTING & SITE DETAILS
HORIZONTAL- NAD 1983/1991 CITY OF
OR) RENTON
DATUM
Planning/Building/Public Works Dept.
DATUM:
NAVD 88
BENCHMARKS:
ORIGINAL BM: FOUND BRASS DISK IN CONCRETE IN THE INTERSECTION OF
S 18TH ST AND GRAND AVE S. WGS POINT DESIGNATION: RENT787.
NORTHING = 172,295.95
EASTING = 1,302,573.67
ELEV. = 317.57
TBM - A: SET MAG NAIL IN SEAM 2' WEST OF TOP BACK CURB
ON WEST SIDEWALK OF GRANT AVE S.
ELEV. = 309.81
TBM - B: SET HUB + MAG NAIL 20' +/- E OF SE CORNER OF HOUSE.
ELEV. = 318.93
C.O.R. BM: MONUMENT IN CASE IN THE INTERSECTION OF
EAGLE RIDGE DRIVE SOUTH AND SOUTH 18TH STREET.
RENTON MONUMENT ID #1063
NORTHING = 172,968.69
EASTING = 1,301,533.10
ELEV. = 261.21
O
N
A
N
Q
J
H
H
N
rw URR DEVELOPMENT ENGINEERING
CNOIN RNEnders 09/16/2024
DER
4715142nd PI. SW #B, WATER UTILITY
Edmonds, WA 98026 ABDOUL GAFOUR 09/13/2024
ph 206.890.8291 W
R-429001 2
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
SURFACE WATER UTILITY 0 ,% WASTEWATER UTILITY z
JFarah 09/03/2024 jstowell 09/12/2024
O
REGIONAL FIRE AUTHORITY
APPROVED `` CURRENT PLANNING LIJ
cthomas 09/03/2024 4 f,RE>V Ming 09/03/2024 Q
J
GRANT PLACE TOWNHOMES 12/05/23
1600 GRANT AVE S RENTON, WA 98055 FIELDBOOK:
PARCEL 2023059052 PAGE:
DRAWING N0:
20069
COVER SHEEP: : OFc1.o 28
T
T
U
ro
8
w
Q
z
J
U_
AS A CONDITION OF APPROVAL
STRUCTURAL CALCULATIONS FOR
THE FOUNDATION DESIGN SHALL
BE SUBMIT TO THE DEVELOPMENT
ENGINEERING PROJECT MANAGER
PRIOR TO INSTALLATION.
DocuSign Envelope ID:
T
PAINT SPECIFICATIONS:
ALL LUMINAIRE, POLE, CAST ALUMINUM BASE PARTS. AND
ANY ADDITIONAL EQUIPMENT MOUNTED ON THE POLE
SHALL BE FACTORY PRIMED AND POWDER COATED TO
MATCH FINISH COLOR.
ALL BANDING AND ALL OTHER MOUNTING HARDWARE
SHALL MATCH FINISH COLOR.
FINISH COLOR: RAL 9005TX "JET BLACK% OR APPROVED
EQUAL WITH PAINT CHIP.
DECORATIVE LUMINAIRE POLE NOTES
© ROUND TUBULAR SECTION
(NO TAPER)
DOME STYLE LED LUMINAIRE
(WATTAGE PER PLANS, TYPE 3 IES
tr DISTRIBUTION, 4000K OCT, 120-277V
w UNIVERSAL DRIVER (75OmA OR
LOWER), WITH FLAT GLASS LENS) BY
CYCLONE (OR APPROVED EQUAL)
DRIVER SHALL BE INTEGRAL TO THE
FIXTURE. FOR MOUNTING ARM DETAILS
SEE STD PLAN 117.3. WIRING PER 4'-0"
o STD PLAN 119.
LUMINAIRE
18°
FOR STREET LIGHT STANDARD DECAL
k NUMBERING DETAIL, REFER TO CITY OF
a RENTON STD PLAN 121
POLE SHAFT FABRICATED FROM 6063-T4
wo ALUMINUM, HEAT TREATED TO T6 CONDITION
AFTER WELDING. 10" O.D. x 0.250" WALL AT
coo BOTTOM OF POLE SHAFT, 9.375" O.D. AT 27"
F UP FROM BUTT OF POLE. TAPERED BETWEEN
of LUMINAIRE CONNECTIONS
0 0
_ NOTE:
STANDARD PLANS REQUIRES
STRUCTURAL CALCULATIONS FOR THE
FOUNDATION. CONDITION TO BE ADDED
ON PERMIT THAT SUCH CALCULATIONS
561D7F SHALL BE PROVIDED PRIOR TO
INSTALLATION OF FOUNDATION.
-ROUND POLE CAP
ALUMINIUM SHROUD (BY MANUFACTURER)
DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, TYPE 3 IES
LUMINAIRE ARM LENGTH DISTRIBUTION, 4000K COT, 120-277V UNIVERSAL DRIVER (750mA OR
PER PLANS, 10' MAX LOWER), WITH FLAT GLASS LENS) BY CYCLONE (OR APPROVED EQUAL)
DRIVER SHALL BE INTEGRAL TO THE FIXTURE FOR MOUNTING ARM
DETAILS SEE STD PLAN 117-3. WIRING PER STD PLAN 119.
(6) 1.38" DIA. X 2" LONG SLOTTED
HOLES WITH 1 i/4° DIA, 4° HEX
27 $"
HEAD CONNECTING BOLTS AND NUTS A36 STEEL,
�1 Y,° THICK
BASE PLATE
,VOID
15"4 BOLT CIRCLE
POLE BASE PLATE DETAIL
FOUNDATION SHALL SUPPORT
POLE SHOWN IN STANDARD PLAN
.'
DECORATIVE BASE COVER PER
DETAIL, THIS SHEET
Z 4
o
m
4° X B" REINFORCED ALUMINUM HANDHOLE
OPENING WITH 5/16"-18 HOLE FORA
GROUND CONNECTOR AND FLUSH FITTING
ALUMINUM DOOR W/ GASKET
CAST ALUMINUM ANCHOR BASE,
INSTALL ANCHOR BOLT COVERS
(PROVIDED BY POLE
.-,
MANUFACTURER)
CONCRETE PAD/SIDEWALK PER STD PLAN
FOUNDATION PER STRUCTURAL ANAI
6" HIGH SIDEWALK
°i OR PLANTER STRIP
-A=F
ROADWAY
20 IF SURFACE IS NOT LEVEL, INSTALL
GROUT AT BASE OF POLE AND
.IS BASE COVER, PROVIDE 1/2" DIA
DRAIN TUBE THROUGH GROUT
POLE ELEVATION
117.1A
FOUNDATION, AND ANCHOR BOLT
DETAILS PER STANDARD PLAN
O
F180HI2111
9
• DECORATIVE ROADWAY LUMINAIRES
ARE MOUNTED AT V
• DECORATIVE PEDESTRIAN LUMINAIRES
ARE MOUNTED AT 180'
• HANDHOLES ARE MOUNTED AT 180'
ORIENTATION LOCATION
9V
OCTAGONAL SPLIT Ti OP I'D�
CAST IRON BASE
WITH REMOVABLE
ACCESS DOOR
z I
21"
DECORATIVE BASE COVER
ARTERIAL STREET STD. PLAN - 117.1
T PUBLIC WORKS DECORATIVE LUMINAIRE POLE
. � . APPROVED:
�F o� DEPARTMENT DETAILS �M�artlnPastucha 7/27/2022
DATE
DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F
7'-0"
LUMINAIRE POLE \ JUNCTION BOX
CONCRETE PAD,
PLAN VIEW BROOM FINISH
LUMINAIRE POLE
CONCRETE PAD
Z
4"
_r - JUNCTION BOX
LUMINAIRE CONCRETE
FOUNDATION
SIDE VIEW
LUMINAIRE CONCRETE PAD DETAIL
GENERAL NOTES:
1. LUMINAIRE CONCRETE PAD SHALL BE USED IN AREAS
OUTSIDE OF SIDEWALK
2. CONCRETE CLASS FOR LUMINAIRE CONCRETE PAD SHALL
BE PER STD PLAN 135
3. TOP OF LUMINAIRE FOUNDATION ELEVATION SHALL BE
LOCATED AT BOTTOM OF LUMINAIRE CONCRETE PAD
ELEVATION OR BOTTOM OF SIDEWALK ELEVA11ON
4. LUMINAIRE POLE AND JUNCTION BOX TYPE PER PLAN
5. LUMINAIRE CONCRETE PAD ACCOMMODATES TYPE 1 AND
TYPE 2 JUNCTION BOXES ONLY
LUMINAIRE POLE JUNCTION BOX
CONCRETE SIDEWALK
PLAN NEW PER STD PLAN 102
UMINAIRE POLE
CONCRETE SIDEWALK
PER STD PLAN 102
� JUNCTION BOX
--LUMINAIRE CONCRETE
FOUNDATION
SIDE VIEW
LUMINAIRE WITH SIDEWALK DETAIL
CONCRETE PAD J / 1'-0.
JUNCTION BOX J/ PLAN VIEW
4"
CONCRETE PAD
JUNCTION BOX SIDE VIEW
INDIVIDUAL JUNCTION BOX PAD DETAIL
��Y a LUMINAIRE CONCRETE STD. PLAN - 120
PUBLIC WORKS PAD/SIDEWALK AND
+� + APPROVED:
p DEPARTMENT JUNCTION BOX CONCRETE PAD MartlnPastueha 712712022
NZ�
DATE
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
NE 1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F _ aCKET CABLE, #10
AWG. SPLICES BETWEEN FUSE
HOLDER AND LUMINAIRE FIXTURE
SHALL NOT BE ALLOWED
FUSE KITS QUICK DISCONNECT 3 AMP 1 TO LUMINAIRE
TO RECEPTACLE
IN LINE FUSE KITS S.E.C. OR EQUAL,
ONE PER CURRENT CARRYING 120VAC RECEPTACLE WIRING, IF
REFER TO WSDOT LOCKING CONDUCTOR. APPLIES TO LUMINAIRE APPLICABLE. WIRING SIZE PER
LID STANDARD DUTY AND RECEPTACLE WIRING CONTRACT
JUNCTION BOX TYPES 1 & TO LUMINAIRE
2 STANDARD PLAN J-40.10 GREEN INSULATED WIRE, SIZED
SPLICE KITS CLEAR EPDXY SPLICE GROUND LUG TO MATCH THE LARGEST
KITS ON ALL THRU WIRE RUNS CURRENT CARRYING CONDUCTOR.
CONCRETE PAD OR TERMINATE AT LUMINAIRE
SIDEWALK PER STD PLAN 120 GROUND LUG
24"(MIN) COVER #8 BARE COPPER II / NON -INSULATED 4 AWG
GROUND WIRE GROUND #
CLAMP II II STRANDED COPPER,
II PROVIDE 3' MIN. SLACK.
1 -EQUIPMENT GROUND 2" PVC CONDUIT II ROUTE FROM GROUNDING
WIRE W/GREEN INSULATION REBARO CONNEECTIOTO
FROM SERVICE CABINET, REBAR USING AN ACORN
SEE NOTE 2, THIS SHEET CLAMP
2 - LIGHTING SYSTEM ROUN' COPPER CLAD GCONCRETE FOUNDATION
WIRES TO CONTACTOR GROUND ROD
(SIZED AS REQ'D.)
2 - 120VAC RECEPTACLE SYSTEM
WIRES TO SERVICE CABINET, IF
APPLICABLE (SIZED AS REQ'D.)
NOTES:
1. THIS DETAIL DEPICTS THE BASIC LUMINAIRE ELECTRICAL WIRING SYSTEM. ADDITIONAL ELECTRICAL EQUIPMENT MAY VARY.
2. MINIMUM GROUND WIRE SIZE SHALL BE #8, AS SHOWN ABOVE. IF CURRENT CARRYING CONDUCTORS ARE LARGER THAN
#8, THE MINIMUM GROUND WIRE SIZE SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING CONDUCTORS.
3. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE
HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE.
4. IF THE FIXTURE MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF A GROUND WIRE, A GREEN INSULATED
WIRE, SIZED TO MATCH THE LARGEST CURRENT CARRYING CONDUCTORS, SHALL BE RUN FROM THE FIXTURE TO THE POLE
GROUND LUG.
5. ALL CONDUIT SHALL BE PVC SCHEDULE 80.
�Y LUMINAIRE ELECTRICAL
STD. PLAN - 119
PUBLIC WORKS WIRING SYSTEM
.� . APPROVED:
DEPARTMENT Martin Pastucha 7/27/2022 I
DATE
DocuSign Envelope ID: 9D9B0DA8-03854664-AE66-57BFF1561D7F
INSTALL DECAL NUMBERS/LETTERS VERTICALLY.
DECAL NUMBERS/LETTERS, SEE NUMBERING
EXAMPLE, THIS SHEET. SHALL BE INSTALLED IN
DRY WEATHER, 50° F OR ABOVE
=m
66
z�
7
Z¢
CD
��
NUMBERING EXAMPLE
Tn
^o
a-
w
MOUNTING HEIGHT DETAIL
1-3/4" TO 2"
I-PEDESTRIAN
SCALE
CURB DECAL
TRAFFIC
FLOW
DECAL ORIEWA710111
FOR POLES SHOWN ON STD PLAN 11&1
PEDESTRIAN SCALE
i:1-PEDESTRIAN
DECAL
SCALE 0�
CURB DECAL CURB
TRAFFIC TRAFFIC
FLOW FLOW
DECAL DRIENTA7111XII
FOR POLE8 8MM ON STD PLAN 1172
-4 TRAFFIC
FLOW
DECAL ORIENrATNNI
FOR POLES SHOWN ON STD PLAN 117.1 & 117,1A
SCALE
CALE
U�cY oT LUMINAIRE STANDARD DECAL STD. PLAN - 121
+�+ PUBLIC WORKS NUMBERING SYSTEM APPROVED:
p DEPARTMENT MartlnPastucha ��z�/zoz2
N S DATE
Know what's below.
Call before you dig.
8/23/2024
PER CITY COMMENTS
PER CITY COMMENTS
PER CITY COMMENTS
PER CITY COMMENTS
REVISION
HEARING EXAMINERS FINAL DECISION
THE PROPOSED PRELIMINARY PLAT ( INCLUDING QUALIFYING AS A UNIT LOT SUBDIVISION), HEARING
EXAMINER SITE PLAN, PARKING MODIFICATION, STREET STANDARDS MODIFICATION AND A LANDSCAPE
VARIANCE COMPLY WITH ALL APPLICABLE CRITERIA FOR THE REASONS IDENTIFIED IN THE CONCLUSIONS OF
LAW OF THIS DECISION AND ARE ALL APPROVED, SUBJECT TO THE FOLLOWING CONDITIONS:
1. A FINAL TREE REPLACEMENT PLAN SHALL BE SUBMITTED AT THE TIME OF CONSTRUCTION PERMIT
REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER. THE FINAL TREE
REPLACEMENT PLAN SHALL INCLUDE THE PLANTING OF AN ADDITIONAL 52.5 TREE CREDITS ON THE
PROJECT SITE.
2. THE FLOOR PLANS SHALL BE REVISED TO IDENTIFY THE REQUIRED BICYCLE PARKING SPACE WITHIN
THE PROPOSED GARAGES. THE REVISED FLOOR PLANS SHALL BE SUBMITTED TO THE CURRENT
PLANNING PROJECT MANAGER AT THE TIME OF BUILDING PERMIT REVIEW FOR THE REVIEW AND
APPROVAL OF THE CURRENT PLANNING PROJECT MANAGER.
3. REVISED FLOOR PLANS SHALL BE SUBMITTED AT THE TIME OF BUILDING PERMIT REVIEW SHOWING THE
REQUIRED TWO FEET BY SIX FEET (2' X 6') FLOOR AREA AND SIXTY INCHES (60") HIGH STORAGE AREA
FOR THE INDIVIDUAL REFUSE AND RECYCLING CARTS. IN ADDITION, SITE PLAN SHALL BE REVISED TO
INCLUDE SPACE FOR CARTS TO BE PLACED ON GARBAGE PICK-UP DAY. THE SPACE MUST BE
SUFFICIENT TO ACCOMMODATE THE NUMBER OF CARTS EXPECTED TO BE SERVICED ON PICK-UP DAY.
THERE SHALL BE A DIRECT CONNECTION CONSTRUCTED OF A SMOOTH SURFACE THAT ALLOWS CARTS
TO BE SMOOTHLY ROLLED TO THE STREET OR OTHER SPECIFIED PICK-UP LOCATION. THE REVISED SITE
PLAN SHALL BE SUBMITTED TO THE CURRENT PLANNING PROJECT MANAGER AT THE TIME OF
CONSTRUCTION PERMIT REVIEW.
4. A CROSS SECTION WITH TOP AND TOE MEASUREMENTS AND MATERIAL COMPOSITION OF THE
PROPOSED RETAINING WALL SHALL BE PROVIDED TO THE CURRENT PLANNING PROJECT MANAGER AT
THE TIME OF CONSTRUCTION PERMIT REVIEW FOR REVIEW AND APPROVAL.
5. A REVISED LANDSCAPE PLAN SHALL BE SUBMITTED AT THE TIME OF CONSTRUCTION PERMIT REVIEW
INCLUDING A FENCING DETAIL DEMONSTRATING THAT THE TOTAL COMBINED HEIGHT OF ANY FENCING
PROPOSED ON TOP OF A RETAINING WALL WOULD NOT EXCEED THE MAXIMUM HEIGHT PERMITTED FOR
A STANDALONE FENCE. THE FENCING DETAIL SHALL BE SUBMITTED TO THE CURRENT PLANNING
PROJECT MANAGER FOR REVIEW AND APPROVAL.
6. A REVISED LANDSCAPE PLAN SHALL BE SUBMITTED AT THE TIME OF CONSTRUCTION PERMIT REVIEW
FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER. THE REVISED
LANDSCAPE PLAN SHALL INCLUDE A THREE-FOOT (T) LANDSCAPED SETBACK BETWEEN ANY RETAINING
WALLS AND THE FRONT PROPERTY LINE ALONG GRANT AVE S.
7. THE PROJECT PROPOSAL SHALL INCORPORATE A VARIETY OF ROOFING COLORS AND THAT THE
ROOFING MATERIAL SHALL BE FIRE RETARDANT. REVISED COLORED ELEVATIONS DEMONSTRATING
COMPLIANCE WITH THIS REQUIREMENT SHALL BE SUBMITTED TO THE CURRENT PLANNING PROJECT
MANAGER AT THE TIME OF BUILDING PERMIT REVIEW.
8. THE APPLICANT SHALL EITHER SUBMIT REVISED ELEVATIONS PROVIDING THE REQUIRED THREE AND
ONE-HALF INCHES (3 1/2") MINIMUM TRIM SURROUNDING ALL WINDOWS AND DOORS AND ONE OF THE
FOLLOWING ARCHITECTURAL DETAILS: SHUTTERS, KNEE BRACES, FLOWER BOXES, OR COLUMNS.
ALTERNATIVELY, THE APPLICANT MAY SUBMIT AN ALTERNATIVE THAT MEETS THE INTENT AND
GUIDELINES OF THE DESIGN SECTION. THE REVISED ELEVATIONS SHALL BE SUBMITTED TO THE
CURRENT PLANNING PROJECT MANAGER FOR REVIEW AND APPROVAL AT THE TIME OF BUILDING
PERMIT REVIEW.
9. A FULLY DETAILED MATERIALS BOARD AND COLOR PALETTE CODED TO EACH BUILDING ELEVATION,
SHALL BE PROVIDED TO THE CURRENT PLANNING PROJECT MANAGER FOR REVIEW AND APPROVAL AT
THE TIME OF BUILDING PERMIT REVIEW.
10. THE APPLICANT SHALL SUBMIT A SEPARATE DETAILED UTILITY AND LANDSCAPE PLAN SET IDENTIFYING
THE LOCATION AND SCREENING PROVIDED FOR ALL SURFACE UTILITY/MECHANICAL EQUIPMENT
REQUIRED FOR EACH TOWNHOME. THE SURFACE MOUNTED UTILITY PLAN SHALL INCLUDE
CROSS-SECTION DETAILS AND SCREENING MEASURES CONSISTENT WITH THE OVERALL DESIGN OF THE
DEVELOPMENT WITH THE CIVIL CONSTRUCTION PERMIT APPLICATION. THE APPLICANT SHALL WORK
WITH FRANCHISE UTILITIES TO ENSURE, AS PRACTICAL, UTILITY BOXES ARE LOCATED OUT OF PUBLIC
ROW VIEW, ACTIVE COMMON OPEN SPACES, AND THEY SHALL NOT DISPLACE REQUIRED LANDSCAPING
AREAS. THE UTILITY AND LANDSCAPE PLAN SET SHALL BE REVIEWED AND APPROVED BY THE CURRENT
PLANNING PROJECT MANAGER PRIOR TO PERMIT ISSUANCE.
11. A SIX-INCH (T) VERTICAL CURB SHALL BE INSTALLED BETWEEN THE UNIT LOT DRIVEWAY AND ABUTTING
LANDSCAPED AREAS. REVISED CIVIL PLANS SHOWING THE CURB SHALL BY SUBMITTED AT THE TIME OF
CONSTRUCTION PERMIT REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT
MANAGER.
12. THE APPLICANT SHALL CREATE A HOMEOWNERS' ASSOCIATION ("HOA") THAT MAINTAINS ALL
IMPROVEMENTS AND LANDSCAPING IN THE COMMON OPEN SPACE TRACTS AND ANY AND ALL OTHER
COMMON IMPROVEMENTS. THE HOA DOCUMENTS SHALL BE SUBMITTED TO, AND APPROVED BY, THE
CURRENT PLANNING PROJECT MANAGER PRIOR TO RECORDING OF THE UNIT LOT SUBDIVISION. SUCH
DOCUMENTS SHALL BE RECORDED CONCURRENTLY WITH THE UNIT LOT SUBDIVISION.
13. ALL TRACTS (E.G. UNIT LOT DRIVEWAY, DRAINAGE, OPEN SPACE, ETC.) SHALL BE PLACED WITHIN
SEPARATE TRACTS THAT WOULD BE OWNED AND MAINTAINED BY THE HOMEOWNER'S ASSOCIATION.
14. ALL PRIVATE OPEN SPACE AREAS ATTRIBUTED TO EACH INDIVIDUAL DWELLING UNIT SHALL BE LOCATED
ON THE SAME UNIT LOT AS THE DWELLING UNIT. A REVISED PLAT MAP SHALL BE SUBMITTED AT THE
TIME OF CONSTRUCTION PERMIT REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING
PROJECT MANAGER, THAT DEMONSTRATES COMPLIANCE WITH THIS REQUIREMENT.
15. THE APPLICANT SHALL BE REQUIRED TO DEMONSTRATE SAFE WALKING CONDITIONS TO/FROM THE
SUBJECT PLAT TO BUS STOP LOCATIONS PRIOR TO CONSTRUCTION PERMIT ISSUANCE.
DATED this 6th day of November, 2023.
City of Renton Hearing Examiner
SURVEYED:
DAF
08/26/24
DESIGNED:
DAF
DAF
07/29/24
DAF
05/21 /24
oRAwN:
TJW, FEM
DAF
04/04/24
CHECKED:
DAF
BY
DATE
I APPR
APPROVED:
SCALE:
1 "=30,
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
ENVIRONMENTAL REVIEW COMMITTEE (ERC)
DETERMINATION OF NON -SIGNIFICANCE -MITIGATED (DNS-M)
PROJECT FILE NUMBERS:
PR23- 000126 / LUA23- 000283, PP, SA- H, ECF, MOD, V-H
PROJECT NAME:
GRANT PLACE TOWNHOMES
APPLICANT
SATWANT SINGH, 15 S GRADY WAY, SUITE 527, RENTON, WA 98057
PROJECT LOCATION:
1504- 1582 SE GRANT CIRCLE, RENTON, WA 98055 ( PARCEL NO. 2023059052)
PROJECT DESCRIPTION:
THE APPLICANT IS REQUESTING PRELIMINARY PLAT APPROVAL, HEARING EXAMINER SITE
PLAN REVIEW, ENVIRONMENTAL (SEPA) REVIEW, A PARKING MODIFICATION, A STREET
STANDARDS MODIFICATION, AND A LANDSCAPE VARIANCE FOR THE CONSTRUCTION OF A
MULTI- FAMILY DEVELOPMENT CONTAINING A UNIT LOT SUBDIVISION WITH 36
TOWNHOMES. THE PROJECT SITE TOTALS APPROXIMATELY 2.14 ACRES AND IS LOCATED
WITHIN THE RESIDENTIAL MULTI- FAMILY (RMF) ZONING CLASSIFICATION, AND THE
RESIDENTIAL HIGH DENSITY (RHD) LAND USE DESIGNATION. THE DEVELOPMENT WOULD
BE COMPRISED OF EIGHT (8) SEPARATE MULTI- FAMILY RESIDENTIAL STRUCTURES.
ACCESS TO THE SITE IS PROPOSED VIA NEW LOOP ACCESS DRIVE EXTENDED FROM
GRANT AVE S. A PARKING MODIFICATION IS REQUESTED AS THE PARKING STALLS WOULD
NOT COMPLY WITH THE MINIMUM DIMENSIONAL REQUIREMENT, A LANDSCAPE SETBACK
VARIANCE IS REQUESTED TO VARY FROM THE 15-FOOT BUFFER REQUIRED ABUTTING A
RESIDENTIALLY ZONED PROPERTY, AND A STREET STANDARDS MODIFICATION WAS
REQUESTED TO MODIFY THE UNIT LOT DRIVEWAY STANDARDS. THE PROPOSED
DEVELOPMENT IS LOCATED ON A PARTIALLY- DEVELOPED SITE THAT WAS ORIGINALLY
PART OF THE EXPIRED GRANT PLACE TOWNHOMES PRELIMINARY PLAT AND PLANNED
URBAN DEVELOPMENT (PUD) (LUA15- 000885 AND LUA17- 000335). THE PRELIMINARY PLAT
AND PUD APPLICATIONS HAVE EXPIRED AND THE PROPOSED TOWNHOME DEVELOPMENT
WOULD REQUIRE NEW LAND USE APPROVALS. THE SITE IS MAPPED WITH SENSITIVE
SLOPES, MODERATE COAL MINE HAZARDS, MODERATE LANDSLIDE HAZARDS, HIGH
EROSION HAZARDS, AND SEISMIC FAULTS.
LEAD AGENCY:
CITY OF RENTON
ENVIRONMENTAL REVIEW COMMITTEE
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT
DATE OF DECISION:
SEPTEMBER 18, 2023
MITIGATION MEASURES:
1. PROJECT CONSTRUCTION SHALL COMPLY WITH THE RECOMMENDATIONS OUTLINED
IN THE GEOTECHNICAL REPORT PREPARED BY NELSON GEOTECHNICAL
ASSOCIATES, INC., DATED JUNE 10, 2005 AS WELL AS THE GEOTECHNICAL LETTER
PREPARED BY COBALT GEOSCIENCES, LLC, DATED MARCH 3, 2023.
2. THE APPLICANT SHALL SUBMIT AN INADVERTENT DISCOVERIES PLAN PREPARED BY
A QUALIFIED PROFESSIONAL WITH THE CIVIL CONSTRUCTION PERMIT FOR REVIEW
AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO PERMIT
ISSUANCE.
3. THE DUWAMISH TRIBE SHALL ALSO BE NOTIFIED IF ANY ARCHEOLOGICAL WORK OR
MONITORING IS PERFORMED ON THE PROJECT SITE.
THE CITY OF RENTON ENVIRONMENTAL REVIEW COMMITTEE HAS DETERMINED THAT
PROBABLE SIGNIFICANT ENVIRONMENTAL IMPACTS FROM THE PROPOSED PROJECT CAN
BE MITIGATED. AN ENVIRONMENTAL IMPACT STATEMENT ( EIS) IS NOT REQUIRED UNDER
RCW 43.21C.030(2)(C). CONDITIONS WERE IMPOSED AS MITIGATION MEASURES BY THE
ENVIRONMENTAL REVIEW COMMITTEE UNDER THEIR AUTHORITY OF SECTION 4-9-070D
RENTON MUNICIPAL CODE. THESE CONDITIONS ARE NECESSARY TO MITIGATE
ENVIRONMENTAL IMPACTS IDENTIFIED DURING THE ENVIRONMENTAL REVIEW PROCESS.
SIGNATURES: DocuSlgned by:
1AAC4DOD98D92A54AO.
njela Barton
_ 9/18/2023 1 2:19 PM PDT
Martin Pastucha, Administrator Date Anjela Barton, Fire Marshal Date
P4Wj,rsi 4s, Chair EVanessa
"acQP0ignal Fire Authority
EF578322688C8E4E2
V" Cale9/18/2023 1 3:23 PM PDT Dolbee 9/18/2023 1 2:24 PM PDT
._53D381 F958CE4E4.--
Maryjane Van Cleave, Interim Administrator Date Vanessa Dolbee, Interim Administrator Date
Parks and Recreation Community and Economic Development
FURR
EN6INEERIN6
QERVICE.% PLLC
4715 142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
CITY OF
RENTON
Planning/Building/Public Works Dept.
�J
co
a
J
R-429002 I�
IN COMPLIANCE WITH CITY OF RENTON STANDARDS =O
DEVELOPMENT ENGINEERING z
NJanders 09/16/2024
O
LU
U
Q
DATE: J
GRANT PLACE TOWNHOMES 11/21/23 0-
1600 GRANT AVE S RENTON, WA 98055 FIELDBOOK:
PARCEL 2023059052 PAGE:
DRAWING N0:
20069
CONDITIONS OF APPROVAL SHEET: OF:
C1.1 28 V
U)
CW
G
O
77
O
I-
U-1
U
Q
n
Z
Q
rr
N
T
U
m
8
w
Q
Z
J
U_
SURFACE WATER STANDARD PLAN NOTES:
THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY
PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE
APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE
SURFACE WATER STANDARD PLAN NOTES.
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY
REFERRED TO AS THE CITY. THE APPLICANT. AND THE APPLICANT'S CONTRACTOR.
12. THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION.
3. ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE
WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL
CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO
CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO
THE CITY.
4. APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER,
SEWER, GAS, ELECTRICAL. ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY
THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION
FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY.
15. A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
6. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL
THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANT'S
CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT
SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS -BUILT DRAWINGS ALL
UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A
CONFLICT EXISTS.
7. VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY.
REFERENCE BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS.
8. ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER SECTION 2-03.3(14)D - COMPACTION AND
MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS ALL TRENCH BACKFILL SHALL
BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY.
9. OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE
APPROVED PLANS, ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS.
10. ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE
DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED.
11. ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE
APPROVED BY THE CITY.
12. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD
SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION
MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE
SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 220.10, AND
220.20.
111 STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR 5 INSIDE AND OUTSIDE.
14. ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT -LOCKING LIDS PER THE CITY STANDARD PLAN
204,10, 204,20, 204,30, 204,40, AND 204.50. STRUCTURES SHALL HAVE:
• RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY.
• ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/GUTTER LINE.
• ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE
PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO.
115. BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM.
16. LIDS OF MANHOLES/CATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/CATCH BASIN RIMS
SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN.
17. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE
DRIVEWAY TO THE BOTTOM OF THE DITCH.
18. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT
AND SHALL MEET THE FOLLOWING SPECIFICATIONS:
• 4 - 8 INCH ROCK / 40 - 70% PASSING;
• 2 - 4 INCH ROCK / 30 - 40% PASSING, AND
• LESS THAN 2 INCH ROCK 110 - 20% PASSING.
19. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE
CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BMPS.
20. THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED "STORM" OR "DRAIN" SHALL BE LOCATED AT THE
PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00.
21. ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED
TO THE CITY PRIOR TO CONSTRUCTION.
22. ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV
ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL
PROJECT CURBS, GUTTERS AND/OR PAVEMENT.
23. ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS
AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS
TESTED.
24. FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL
EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN
264.00.
25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY
CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM
SYSTEM PROVIDED DURING CONSTRUCTION.
26, ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF
THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED
RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT
STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY.
27. PROJECTS LOCATED WITHIN THE CITY'S AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT #6 OF THE RENTON SWDM AND AQUIFER
PROTECTION REGULATIONS (RMC 4-3-050).
28. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASIN/MANHOLE LIDS, CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF
STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A
SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID LID PER ADA REQUIREMENTS.
129. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT.
130. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM.
31. CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE
PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO
CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE
PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE
MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE,
THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS (E.G., PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE
WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING
ASTM C1781.
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
Know what's below.
Call before you dig.
8/23/2024
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N.7 R. 05 E, W.M.
GRANT PLACE TOWNHOMES
Utility Specifications
Vater Utility Notes and Specifications
THESE NOTES SHALL APPEAR ON PROJECTS FOR THE WATER UTILITY.
1. All work material shall be in conformance with the standards and specifications of the
City of Renton Planning/Building/Public Works Department and the latest edition of the
WSDOT/APWA Standards and Specifications, as approved and modified by the City of
Renton in the Renton Standard Plans & Specifications. A set of approved plans shall be
kept on site at all times during construction.
2. The hours of work in the street right of way shall be limited to 8:30 AM to 3:30 PM on
weekdays unless otherwise approved in writing by the Public Works Department at
(425) 430-7301. The Police Department, Fire Department, and 911 shall be notified 24
hours in advance of any work in the right of way,
3. All locations of existing utilities shown are approximate and it shall be the contractor's
responsibility to verify the true and correct location so as to avoid damage or
disturbance. For utility locates call 48-hour locators 800-424-5555.
4. An approved Traffic Control Plan is required to be submitted at the Pre -Construction
meeting.
5. Datum for Vertical Control shall be North American Vertical Datum 1988 Meters and for
Horizontal Control shall be North American Datum 1983/1991 Meters unless otherwise
approved by the City of Renton Public Works Department. Reference benchmark and
elevations are noted on the plans.
6. All watermain pipe is to be cement lined ductile iron pipe conforming to AWWA C110
and C111 or latest revision, thickness Class 52. Cement mortar lining and seal coating
shall conform to AWWA C104 or latest revision. Pipe joints to be push -on or mechanical
joint. Bedding to be Class C. All ductile iron pipe and fittings shall be polyethylene
wrapped per ANSI/AWWA C105/A21.5-93 Standards.
7. Cast iron and ductile iron fittings shall be cement lined, pressure rated as noted on
plans, and in accordance with ANSI/AWWA C110/A21.10-87. Cement lining shall be in
accordance with ANSI/AWWA C104/421/4-90. If fittings are 3 to 12 inches in diameter
and have mechanical joints, the fittings shall in accordance with either ANSI/AWWA
C110-A21.10-87 or ANSI/AWWA C153/A21.53-94. Three (3) inch to 12 inch diameter
fittings, which have mechanical joints and/or flanged joints, shall be in accordance with
ANSI/AWWA C110/A21.10.87 or a combination of ANSI/AWWA C110/A21.10.87 and
ANSI/AWWA C153/A21.53-94 such that the portion of the fitting with a mechanical
joint(s) may be with ANSI/AWWA C153/A21.53-94 and that portion of the fitting with
flanged joint(s) shall be in accordance with AWWA C110/A21,10-87. Acceptance testing
in accordance with section 53.53 of ANSI/AWWA section 10-4.3 of ANSI/AWWA
C110/A21.10-87 shall be obtained by the contractor and transmitted to the owner.
8. Gate valves shall be iron body, bronzed -mounted, double disc with bronze wedging
device and 0-ring stuffing box (AWWA C500) or of resilient seated type (AWWA C509).
Valves shall be designed for a minimum water operating pressure of 200 psi. Gate
valves shall be Clow List 14, Mueller Company NO. A2380 or M & H.
9. Fire hydrants shall be Corey type (opening with the pressure) or compression type
(opening against pressure) conforming to AWWA C-502-85 with a 6 inch mechanical
joint inlet and a main valve opening (M.V.O.) of 5-1/4 inch, two 2-1/2 inch hose nozzles
with National Standard Threads 7-1/2 threads per inch and one 4 inch pumper nozzle
with the new Seattle Pattern 6 threads per inch, 60 degrees V. Threads: outside
diameter of male thread 4.875 and root diameter 4.6263. Hydrants shall have a 1-1/4
inch pentagon operating nut opened by turning counter clockwise (left).
10. The two 2-1/2 inch hose nozzles shall be fitted with cast iron threaded caps with
operating nut of the same design and proportions as the hydrant stem nut. Caps shall
be fitted with suitable neoprene gaskets for positive water tightness under test
pressures.
11. The 4 inch pumper nozzle shall be fitted with a Storz adapter, 4 inch Seattle Thread x 5
inch Storz. Storz adapter shall be forged and/or extruded 6061-T6 aluminum alloy,
hardcoat anodized. Threaded end portion shall have no lugs and two set screws 180
degrees apart. Storz face to be metal, no gasket to weather. Storz cap to have
synthetic molded rubber gasket, and shall be attached to hydrant adapter with 1/8 inch,
coated, stainless steel, aircraft cable.
12. Fire hydrants shall be painted with two coats of paint. Preservative paint number 43-
655 safety yellow or approved equal.
13. Pumper connection to face roadway assembly.
14. Fire hydrants shall be installed per City of Renton Standard Detail for fire hydrants,
latest revision.
15. All watermains 10 inches and smaller to maintain a minimum cover of 36 inches below
finish grade. All watermain 12 inches and larger shall be at a minimum of 48 inches
below finish grade. Where utility conflicts occur, watermains are to be lowered to clear.
16. All watermains 6 inches and larger in diameter shall be cleaned with pipe cleaning
"PIGS" prior to disinfection. The "Poly pigs" shall be Girard Industries Aqua Swab -AS or
approved equal, 2 lb/cu. ft. density foam with 90A durometer urethane rubber coating
on the rear of "PIG" only.
17. "PIGS" shall be cylinder shaped with bullet nose or square end. The contractor will
perform the cleaning operation,
18. All watermains and services shall be pressure tested to a minimum of 200 psi or 150 psi
over operating pressure, in accordance with the specifications of the City of Renton and
the Washington State Health Department. All pressure testing shall be done in the
presence of a representative of the City of Renton. The quantity of water lost from the
main shall not exceed the number of gallons per hour as listed in City of Renton
Utility Specifications
Vater Utility Notes and Specifications
THESE NOTES SHALL APPEAR ON PROJECTS FOR THE WATER UTILITY.
1. All work material shall be in conformance with the standards and specifications of the
City of Renton Planning/Building/Public Works Department and the latest edition of the
WSDOT/APWA Standards and Specifications, as approved and modified by the City of
Renton in the Renton Standard Plans & Specifications. A set of approved plans shall be
kept on site at all times during construction.
2. The hours of work in the street right of way shall be limited to 8:30 AM to 3:30 PM on
weekdays unless otherwise approved in writing by the Public Works Department at
(425) 430-7301. The Police Department, Fire Department, and 911 shall be notified 24
hours in advance of any work in the right of way.
3. All locations of existing utilities shown are approximate and it shall be the contractor's
responsibility to verify the true and correct location so as to avoid damage or
disturbance. For utility locates call 48-hour locators 800-424-5555.
4. An approved Traffic Control Plan is required to be submitted at the Pre -Construction
meeting.
5. Datum for Vertical Control shall be North American Vertical Datum 1988 Meters, and for
Horizontal Control shall be North American Datum 1983/1991 Meters unless otherwise
approved by the City of Renton Public Works Department. Reference benchmark and
elevations are noted on the plans.
6. All watermain pipe is to be cement lined ductile iron pipe conforming to AWWA C110
and C111 or latest revision, thickness Class 52. Cement mortar lining and seal coating
shall conform to AWWA C104 or latest revision. Pipe joints to be push -on or mechanical
joint. Bedding to be Class C. All ductile iron pipe and fittings shall be polyethylene
wrapped per ANSI/AWWA C105/A21.5-93 Standards.
7. Cast iron and ductile iron fittings shall be cement lined, pressure rated as noted on
plans, and in accordance with ANSI/AWWA C110/A21.10-87. Cement lining shall be in
accordance with ANSI/AWWA C104/421/4-90. If fittings are 3 to 12 inches in diameter
and have mechanical joints, the fittings shall in accordance with either ANSI/AWWA
C110-A21.10-87 or ANSI/AWWA C153/A21.53-94. Three (3) inch to 12 inch diameter
fittings, which have mechanical joints and/or flanged joints, shall be in accordance with
ANSI/AWWA C110/A21.10.87 or a combination of ANSI/AWWA C110/A21.10.87 and
ANSI/AWWA C153/A21.53-94 such that the portion of the fitting with a mechanical
joint(s) may be with ANSI/AWWA C153/A21.53-94 and that portion of the fitting with
flanged joint(s) shall be in accordance with AWWA C110/A21.10-87. Acceptance testing
in accordance with section 53.53 of ANSI/AWWA section 10-4.3 of ANSI/AWWA
C110/A21.10-87 shall be obtained by the contractor and transmitted to the owner.
8. Gate valves shall be iron body, bronzed -mounted, double disc with bronze wedging
device and 0-ring stuffing box (AWWA C500) or of resilient seated type (AWWA C509).
Valves shall be designed for a minimum water operating pressure of 200 psi. Gate
valves shall be Clow List 14, Mueller Company NO. A2380 or M & H.
9. Fire hydrants shall be Corey type (opening with the pressure) or compression type
(opening against pressure) conforming to AWWA C-502-85 with a 6 inch mechanical
joint inlet and a main valve opening (M.V.O.) of 5-1/4 inch, two 2-1/2 inch hose nozzles
with National Standard Threads 7-1/2 threads per inch and one 4 inch pumper nozzle
with the new Seattle Pattern 6 threads per inch, 60 degrees V. Threads: outside
diameter of male thread 4.875 and root diameter 4.6263. Hydrants shall have a 1-1/4
inch pentagon operating nut opened by turning counter clockwise (left),
10. The two 2-1/2 inch hose nozzles shall be fitted with cast iron threaded caps with
operating nut of the same design and proportions as the hydrant stem nut. Caps shall
be fitted with suitable neoprene gaskets for positive water tightness under test
pressures.
11. The 4 inch pumper nozzle shall be fitted with a Storz adapter, 4 inch Seattle Thread x 5
inch Storz. Storz adapter shall be forged and/or extruded 6061-T6 aluminum alloy,
hardcoat anodized. Threaded end portion shall have no lugs and two set screws 180
degrees apart. Storz face to be metal, no gasket to weather. Storz cap to have
synthetic molded rubber gasket, and shall be attached to hydrant adapter with 1/8 inch,
coated, stainless steel, aircraft cable.
12. Fire hydrants shall be painted with two coats of paint. Preservative paint number 43-
655 safety yellow or approved equal.
13. Pumper connection to face roadway assembly.
14. Fire hydrants shall be installed per City of Renton Standard Detail for fire hydrants,
latest revision.
15. All watermains 10 inches and smaller to maintain a minimum cover of 36 inches below
finish grade. All watermain 12 inches and larger shall be at a minimum of 48 inches
below finish grade. Where utility conflicts occur, watermains are to be lowered to clear.
16. All watermains 6 inches and larger in diameter shall be cleaned with pipe cleaning
"PIGS" prior to disinfection. The "Poly pigs" shall be Girard Industries Aqua Swab -AS or
approved equal, 2 lb/cu. ft. density foam with 90A durometer urethane rubber coating
on the rear of "PIG" only.
17. PIGS shall be cylinder shaped with bullet nose or square end. The contractor will
perform the cleaning operation.
18. All watermains and services shall be pressure tested to a minimum of 200 psi or 150 psi
over operating pressure, in accordance with the specifications of the City of Renton and
the Washington State Health Department. All pressure testing shall be done in the
presence of a representative of the City of Renton. The quantity of water lost from the
main shall not exceed the number of gallons per hour as listed in City of Renton
Standard Plans & Specifications 7-11.3(11). The loss in pressure shall not exceed 5 psi
during the 2 hour test period.
19. All watermains and services shall be disinfected by the injection of a 50 ppm (minimum
concentration) chlorine/water solution. Dry Calcium Hypochlorite shall NOT be placed in
the pipe as laid. Chlorine shall be metered/injected in accordance with Section 7-
11.3(12)E or 7-11.3(12)F of the Standard Specifications referenced above.
20. A pre -construction conference is required prior to any construction. A minimum of five
(5) working days notice is required for scheduling.
21. Twenty-four (24) hours notice will be required prior to starting new construction.
22. It shall be the contractor's responsibility to secure all necessary permits prior to starting
construction.
23. Installation of corporate stops, water services, lines and meters shall not be done until
all service agreements, meter applications, construction permits, and payment of fees
have been made to the City of Renton.
24. All connection to existing mains is to be accomplished by the City of Renton, except wet
taps, which may be made by approved wet tap contractors with prior approval from the
Public Works Department. All necessary excavation and materials are to be supplied by
the contractor and be on -site prior to City notifications.
25. Inspection will be accomplished by a representative of the City of Renton. It shall be
the contractor's responsibility to notify Development Services twenty four (24) hours in
advance of backfilling all construction. The contractor, as well as the engineers, shall
keep as -built drawings.
26. Contractor to provide plugs and temporary blow -off assemblies for testing and purity
acceptance prior to final tie-in.
27. All joint restraint systems (shackle rods, nuts, bolts, etc.) shall be as manufactured by
the Star Manufacturing Company of Columbus Ohio, or equal, approved in writing by the
Public Works Department.
28. Asphalt and concrete street paving shall be sawcut to a minimum depth of two (2)
inches. Oil mat streets may be spade cut. All surface concrete, pavement, sidewalks,
curb, gutters, and driveway approaches shall be sawcut to a minimum depth of two (2)
inches or removed to an existing expansion joint.
29. A temporary cold mix asphalt patch shall be placed on the day of initial excavation with
a permanent, sealed patch to be placed, to City of Renton policy, within 10 days. Call
for subgrade inspection prior to placement of final patch.
30. For City projects such as telemetry conduit, the PVC pipe used shall be All chemical
process lines shall be schedule 80 PVC pipe. Schedule 40 in unimproved areas and
schedule 80 PVC pipe under improved areas.
FURR
/ \SERVIMS, Pu.c
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291 R-429003
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
NJanders 09/16/2024
SURVEYED: SCALE, DATE:
"Eff' NAVD 1988 GRANT PLACE TOWNHOMES / /
4 PER CITY COMMENTS DAF 08/26/24 1 "=30' HORIZONTAL: NAD ,sas/,ss, CITY 0 F 11 21 23
3 PER CITY COMMENTS DAF 07/29/24 DESIGNED: 1600 GRANT AVE S RENTON, WA 98055 FIELDBOOK:
2 PER CITY COMMENTS DAF 05/21/24 DRAWN: TJW, FEM RENTON PARCEL 2023059052 PAGE:
• DRAWING N0:
1 PER CITY COMMENTS DAF 04/04/24 CHECKED: ONE INCH DATUM
DAF AT FULL SCALE Planning/Building/Public Works Dept. 20069
IF NOT ONE INCH
N 0 . REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY NOTES SHEET: OF,
C 1.2 28
V)
M
O
QD
O
O
C'7
N
On
u
co
Q
J
U)
CW
G
O
2
Z
O
W
U
Q
J
Z
a
rr
0
N
0
W
V )
W
75
O
2
z
O
I-
W
CU
n
I-
z
0
O
N
U
NE 1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
I
I
SDMH-1 (T2)
CB-1 Ti RIM=294.51 Q-
RIM=293.78 12 CMP N=290.01
12" CMP S=290.58 12" CMP E=286.71
8" CMP W=290.93 12" CMP S=287.21 SFMH (T2)
12" CMP W=286.61 RIM=300.62
/;;•, 1-' 12" CMP S=290.82
SDMH-2 (T2) *WESTERLY INVERT IS COVERED
:•
TOP CONC. RISER=295.72 BY CONTECH INTERNALS
12" CMP E=288.17
12" CMP 5E=288.37 CB-8 (TYPE ,> �/� GB-9 (TYPE 1) �1 PORTION OF PARCEL 2 31 9)013 CB-12 (TYPE 1)
RIM= (TYPE J �� RIM CPEP E&W=312.18 1 L CB-10 (TYPE 1) R� 327.42 w RIM= 335.24
TYP 4 RIM CPEP E&5=300.63 01 437 RIM= 319.14 12" CPEP E&W= 323.97 w 12" CPEP E&W= 332.19EXPOS
O LTOP'OFBPIPE S PIPE 289.28 / c p\ 12" CPEP E\= 315.99 \ / 1 \ \ \ \ \ \ I -3
30'l // /� / / N89"09'24"E
30' rn \ I (' JI ROCKERY \ ROCKERY �,V F S ;: IF RO ERY
< _
< -
�S < < < < \ RIK1133 �11)
�� 40.77
3+00 _.., . ✓ 5 �" CF)EP NW& = 3 s.a
- - - _ h
i 5 -
I
�'�:,<5 - ! - �. �. S � ��.b•,� �4�4,� �,��dy.�4,� r,,X:6,�ad. �`a.rux` �.� .�'
I •ssco ,F. I r� I
,� „� '' �, • lam(/J
/ s�o ssco
w SSCO - . SSCO I SSCO SSCO / SSCO SSCO q ,, ,~ ` I •;�i�, o SSCO � � FH SSMH-10 , FF=359.52 FF=361.03 FF=3�.52 - "ep
FH RIM- 35Fi10 I FF=357.98 BUILDING 4 FF-36401 \\
FF=333.44 I TI�CH.= 326.80
'• FF=334.94 1 J �1
a• J I 0 \ WATER SERVICE FF=331.59 FF=333.31 ^ -/ f;•, ! 1 G
yy, VLACCESS GIP WATER SERVICE WATER SERVICE WATER SERVICE o�
AO' WATER SERVICE LINE ETER LOCATION WATER SERVICE WATER SERVICE �q0� LINE M
12" C P \ SMH-9 / LINE/METER LOCATION LINE/METER LOCATION LINE/METER LOCATION WATER SERVICE :;y( •`; \ / ETER LOCATION LINE/METER LOCATION FF=354. 6 `gyp PP�� / \ LINE/METER LOCATION '•.''{?` \ \ FF=351.13 FF=354.22 /
\ \ N=288.61 4IM= 13.68 / LINE/METER LOCATION
3 _ `l FF=348.19 FF=349.75 /
y TTTffi p
\ CTR. �H.= 306.2 GIPI f\\ FF=352.61
� FF=343.57 FF=344.56 N=290. ' t» SSCO
\ VLT S 8 \/ \ BUILDING 2 / pR PIP `;+°;XT!'-.7„, SSCO SSC SSCO
LID=3 \ • ' KEYST NE I I BUILDING 1 ( FOUNDATION ONLY i FF=343.03 FF=343.04 1 i , w B-7 (N ID)
\ b 12" CPEP /WALL w (FOUNDATION ONLY) ( ) / ssco WJe \ -TOP CO .STRUCTURE
":• \ \ / N=295.57 / I \�f I ( \ o / I F: o M \ = 353.7
O F ....'.. •:.�..:":'.:' + 0' :•• 12" CPE = 349.02
I__CB (TYPE 1) NO RIM (
\ I \ I \ \ 12" CPEP 3 \ \ \ CB-16 (T1E 1) CB-17 (TYPE 1) WV
y•;.,.. SS / OI
2 RIM=325.1 I RIM=334.44 I '' SSMH-8 ('�') O
i o w \ 2.05AC DISTURBED AREA / \ \ wv , .; :. 5 RIM= 353/i4
\ L I 0 I \ \ \ 12" CPEP SW=312.67 / N 12" CPEP 323.03 I 12" CPEP W=332.3d �'y O \ CB-6 ( �':�' °?'." / SSCO / , / 00
r ' 0 O 4` PVC 5=315.47 \ 12" CPEP=323.03 RIM= 343 .9;:.•'.: .`'"
:. C/0 3 7 0
�`° �` : \ I I I I `aao / / 7 / \ I I 1 \ / i \ \ \ ssco ssco w CD
n
• ( 12" CPEP 5 O
ACCESS 5 12" CPEP �� / ( \ l l I I \ / \ \ "' / N O
�'" •1:"; , / \ D=304.90 \ E=289.21 I SD SD SD SSMH- ,; ;llP FF=34 .53 FF=350.87 FF=352.46 FF=353.96 O
OZ O \ T ACCES 4 \ :• \
Y. .
ID=304.18
FF=348.25 WATER SERVICE J
ACCESS 1 0� I C FT . ;33 .1f+;, :. WATER SERVICE LINE/METER LOCATION _ 0
~" LID=308.85 \ ` 1 FF= 41.57 LINE/METER LOCATION BUILDING 5 O
yyI \ \ BUILDING % \ FF=341.54 \ "
BUILDING 8 \ `- FF=343.08 FF=364.01 z Q
\ \ \ ) \ \ (FOUNDATION ONLY) BUILDING 6 FF=357.99
FOUNDATION ONLY FF=340.19 ^r:. ". ?.,;' + \/ I FF=360.98 FF=362.52
I ( ) ..:...:..v...... I
3 \ VLT ACCESS 3 0 307.4 FF=359.48
0 * ° �O D=ACC g O \ I WATER SERVICE WATER SERVICE
AO//` FH \ \ IN LOCATION LINE/METER LOCATION B ":.;-
I WATER SERVICE PR
1 GIP WATER SERVICE � ; Si".'..;.;•:,:::.:,; '
/ \ WATER SERVICE LINE/METER LOCATION LINE ME R LOCATION FF=3 0.35 FF=331.80 FF=333.47 PM ':, : O"•';." i
ACCESS 2 \ WATER SERVICE / /
H. LID=3 8.09 U) LINE ETER LOCATION 330� \ x;
/0 55 :n /M LINE/METER LOCATION I SS H-6 (TYP 2) \ \ �5.SNAG
` FH \ \
V I C/0 I I ` \ FH \ _ .,',.;,.:.',;;•.1 I 7 t. C 332.$1 \ . ,sue,.,
SSCO SSCO SSCO „ , ,, 1/I � "�M �341.81 \
12" CPEP I \ \ SSCO SSC SSCO\ \ �,V / ',i::.:!!, ,.�:,Gj _`,i,•. I SF D
G I / S=288.98 I \ SSCO / SSCO SSCU SSCO WV / \
I ) 6A'..' P
F E
F
:�ti:. P x. ,1
Y /
1 2
•� 5 -
P
r
0
1 A
V 0
- - 1
/
5. N G R •
5
a
:s /
r s• ,.
0
0 , - P
' S� cry
r-
_ E
2
ELECTRICAL 1:'" `"' / i CB-5 ( E 1) g
O JUNCTION BOX t. CH BASIN (T1) CB- (TYPE 1) \ \ CB 4 (TYPE Ij 544'71 / / / c POWER 14.SNAG / ��
v CB-3 TYPE 1) RIM= 333.51 t
PV \ RIA 306.21 \ SSMH-4 (TYPE 2) RIM- 14.10 ( b(D 12" CPEP E= 321.85 8" PVC NE= 331.06 SSMH-5 (TYPE 2) INDICATOR POST
�y GV .L 12" CPEP E=302.54 RIM= 317.67
RIM-313.13 12 CPEP E=311.00 12" CPEP W= 321.85 12" CPEP W= 330.41 RIM= 336.85
12" CPEP E= 314.67
>E' y -j 12 \CPEP N=302.54 CTR. -CH.= 305.23 12" CPEP W=310.90 CTR. CH.= 328.70
FIRE 1 `-" >j ;, I 12" CPEP W= 314.57
HYDRANT
POWER �\ sr, t m STORM DRAIN MANHOLE (T2)
RISER IA c RIM=313.98 PARCEL 326060-0000
... •N:....
,; 'j '7;f.+i, A 70 36" CMP 5=303.68
CATCH BASIN (Ty -� ;:r I z a W/ TREE HERITAGE VILLAGE CONDOMINIUM
RIM=307.43 a a 12" CMP W=303.63
12" CMP E=303.24 *'i ' ?;t. TOP TREE=311.98
12" CMP W=463.24
6" CPEP N= 05.39 �C , ' o�U� OFFSITE
BUILDING STORM DRAIN MANHOLE (T2)
/ '�+;;,• / RIM=313.87
12" CMP N= 304.40
'. 30 r`•: I < 0 12" CMP SE= 308.50
f f,✓
/CATCH BASIN (T1) '•":: T ?` ^� z
RIM=307.45
8" CPM E=305.35 1.::A '• + N x
5p _ , " \ SSMH-A (CENTER STRUCTURE)
yt ,• ", \ \ RIM=315.57
STORM DRAIN MANHOLE (T2) -1 G, p, - _ CTR CH-303.42
RIM=307.95 TB
12 CMP E-303.10 0 %: i'<• \
12" CMP N=302.95 g^
8" CMP W=303.45k,. C� ''�;. ,•'1.,..:.',::.::
,y, P
LEGEND
CONSTRUCTION NOTES
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
14.
31
\
•;;`'icy
\
,-�i.
I �
:Y
TELEPHONE
RISER
k
I
Know what's below.
Call before you dig.
8/23/2024
SF HIGH VISIBILITY SILT FENCE
LIMITS OF CLEARING AND GRADING
OB OB
TREE TO BE PROTECTED - ORANGE BARRIER FENCE
❑:: INLET PROTECTION
OO STABILIZED CONSTRUCTION ENTRANCE
O O
-< < INTERCEPTOR SWALE WITH ROCK CHECK DAM
SURVEYED:
4
PER CITY COMMENTS
DAF
08/26/24
DESIGNED:
DAF
3
PER CITY COMMENTS
DAF
07/29/24
2
PER CITY COMMENTS
DAF
05/21/24
DRAWN:
TJW, FEM
1
PER CITY COMMENTS
DAF
04/04/24
CHECKED:
DAF
NO.
REVISION
BY
DATE
APPR
APPROVED:
SCALE:
1 "=30'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
ID FLAG CLEARING LIMITS TO EXTENTS SHOWN ON THE PLAN.
2O HIGH VISIBILITY SILT FENCE PER DETAIL SHEET C2.1
OCONSTRUCTION ENTRANCE PER DETAIL SHEET C2.1
0
CATCH BASIN INSERT PER DETAIL SHEET C2.1
OINTERCEPTOR DITCH W / ROCK CHECK DAMS PER DETAIL SHEET C2.1
OTREE PROTECTION FENCE
O7 MULCH SITE PER SWDM SECTION C.3.2
OVAULT TO BE USED TO STORE SEDIMENT -LADEN STORMWATER
DURING CONSTRUCTION
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
CITY OF
RENTON
Planning/Building/Public Works Dept.
0)
M
Q0
MO��
t•J
N
LJ
�,
co
a
J
ruRR
ENOINEERING
SERVICES, PLLC
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206 890 8291 0
R-429004 I�
IN COMPLIANCE WITH CITY OF RENTON STANDARDS =O
DEVELOPMENT ENGINEERING z
NJanders 09/16/2024
O
P-
W
U
Q
DATE: J
GRANT PLACE TOWNHOMES 11/21/23 a-
1600 GRANT AVE S RENTON, WA 98055 FlELDBOOK:
PARCEL 2023059052 PAGE:
DRAWING N0:
20069 �
TESC PLAN SHEET: OF: r • '
C2.0 28 V
0
N
I
Lu
I-
T
N
U
JOINTS IN FILTER FABRIC SHALL BE SPLICED AT
POSTS. USE STAPLES, WIRE RINGS, OR
EQUIVALENT TO ATTACH FABRIC TO POSTS
2"x2" 14 GAUGE WIRE, OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
FILTER FABRIC
7
2' AIIN
------------
6' MAX. - I I I I 12" MIN.
PO O 8' IF WI SACING E BACKING IS USEMAI BE D I I 4"x4" MIN. TRENCH I I
;lull BACKFILL TRENCH WITH NATIVE SOIL
OR 3/4" TO 1-1/2" WASHED GRAVEL
2"x4" WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP.)
NOTES:
1. CONDITIONS OF USE
1I .1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS.
1.2. SLT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED
FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE.
ADS (ASTM D4751)
30-100 SIEVE SIZE (0.60-0.15mm) FOR SILT FILM
50-100 SIEVE SIZE (0.30-0.15mm) FOR OTHER FABRICS
WATER PERMITTIVITY (ASTM D4491)
0.02 SEC 1 MINIMUM
GRAB TENSILE STRENGTH (ASTM D4632)
180 LBS. MIN. FOR EXTRA STRENGTH FABRIC
100 LBS. MIN. FOR STANDARD STRENGTH FABRIC
GRAB TENSILE ELONGATION (ASTM D4632)
30 % MAX. (WOVEN)
ULTRAVIOLET RESISTANCE (ASTM D4355)
70 % MIN.
2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED
FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE.
2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V
2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4"X4" TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND
SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE.
2.5. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE.
3. MAINTENANCE STANDARDS
3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY.
3.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND.
3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING
CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT.
3.4. SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH.
3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED.
UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS)
AoaSTD. PLAN - 214.00
c®♦ PUBLIC WORKSbi,, FPRE
7%1-*DEPARTMENT SILT FENCE GAZ 9/28/2018
P„mi,Wo ,Adm l,t,a DATE
EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES:
THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL (ESC) PLAN SET. ALL THE NOTES ON THE
LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT
APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC
ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES.
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY
REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR.
2. THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL
PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY
ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT.
3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION
COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS.
4. THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS
PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF
RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE
BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF
CONSTRUCTION.
5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT.
ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT
CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL
BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING
WATERS OF THE STATE.
6. WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF -SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE
TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON -SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE
WASHOUT AREAS.
7. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF
SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL
SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER
CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION,
MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT.
8. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY.
9. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS, AS CONSTRUCTION
PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE
COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE
APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM
REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM.
10. APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS,
CHANNELS, OR STORMWATER FACILITIES.
11. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL.
12. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST
THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED
ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM.
13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY.
14. ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS.
15. THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT.
INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY.
16. BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM
DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED
TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING
CONDITION.
17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE
CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM.
18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL
PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE
TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT
FACILITY.
19. AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING STORMWATER FACILITIES OR ON -SITE BMPS (AMENDED SOILS, BIORETENTION, PERMEABLE PAVEMENT,
ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION.
20. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR
SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON.
AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW,
21. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVING THE PROJECT SITE,
ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON -SITE BMPS SHALL BE RESTORED TO THEIR FULLY
FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM,
DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH
WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST.
22. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS
RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF
ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 268.00
PRIgPUBLIC WORKS EROSION AND SEDIMENT CONTROL PPR °
DEPARTMENT GAZ 9/28/2018
STANDARD PLAN NOTES
PuAlir-Ad-k-l- DATE
NE 1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N.3 R. 05 E, W.M.
GRANT PLACE TOWNHOMES
EXtsS\NGROPD
R = 25' MIN. -\ �f
INSTALL DRIVEWAY CULVERT
IF THERE IS A ROADSIDE
DITCH PRESENT, AS PER CITY
ROAD STANDARDS
4"-8" QUARRY SPALLS
GEOTEXTILE
12" MIN. THICKNESS
100' MIN.
CONSTRUCTION ENTRANCE NOTES:
1. DRIVEWAYS SHALL BE PAVED TO
THE EDGE OF THE RIGHT-OF-WAY
PRIOR TO INSTALLATION OF THE
CONSTRUCTION ENTRANCE TO
AVOID DAMAGING OF THE
ROADWAY.
2. IT IS RECOMMENDED THAT THE
ENTRANCE BE CROWNED SO THAT
RUNOFF DRAINS OFF THE PAD
15' MIN.
PROVIDE FULL WIDTH OF
INGRESS/EGRESS AREA
NOTES:
1. CONDITION OF USE
1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER
PAVED AREAS WITHIN 1,000 FEET OF THE SITE-
1-2- FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVISION
ENTRANCE. STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTHWIDTH TO PROVIDE VEHICLE ACCESS/PARKING, BASED ON LOT SIZE/CONFIGURATION.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. A SEPARATION GEOTEXTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTEXTILE
SHALL MEET THE FOLLOWING STANDARDS:
GRAB TENSILE STRENGTH (ASTM D4632)
200 LBS. MIN.
GRAB TENSILE ELONGATION (ASTM D4632)
30% MAX. (WOVEN)
CBR PUNCTURE STRENGTH (ASTM D6241)
495 LBS. MIN.
ADS (ASTM D4751)
20.45 (U.S. STANDARD SIEVE SIZE)
2.2. DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE PH
LEVELS IN STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED.
2.3. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS.
HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS
IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT.
2.4. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE.
2.5. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY INCREASE THE
EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE.
3. MAINTENANCE STANDARDS
3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS.
3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF
SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF A WHEEL
WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND.
3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE
REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND
THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE
WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND
CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS.
3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY.
3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL
TRAFFIC.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 215.10
c PUBLIC WORKS APPROVED:
DEPARTMENT STABILIZED CONSTRUCTION ENTRANCE GAZ 9/28/2018 1
vPnrvwPd,: Aamm�:n,ro, DATE
CONSTRUCTION SEQUENCE:
5" MAX.
DRAINAGE GRATE TRIM
GRATE FRAME _
C- OVERFLOW BYPASS
d
BELOW INLET GRATE DEVICE
SEDIMENT AND DEBRIS
.b
FILTERED
WATER
SECTION VIEW
DRAINAGE GRATE
(RECTANGULAR GRATE SHOWN) RETRIEVAL SYSTEM (TYP.)
OVERFLOW BYPASS (TYP.)
BELOW INLET GRATE DEVICE
ISOMETRIC VIEW
NOTES:
1. PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR
CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP.
2. INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM.
3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE.
4. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE.
5. THE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS).
6. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL.
7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15).
8. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE
STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 216.30
v PUBLIC WORKS APPR FD
DEPARTMENT CATCH BASIN INSERT GAZ 9/28/2018 1
DATE
1. PRE -CONSTRUCTION MEETING.
2. POST SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR (MAY BE CONSOLIDATED WITH THE REQUIRED NOTICE OF
CONSTRUCTION SIGN).
3. FLAG OR FENCE CLEARING LIMITS.
4. INSTALL CATCH BASIN PROTECTION IF REQUIRED.
5. GRADE AND INSTALL CONSTRUCTION ENTRANCE(S).
6. INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.).
7. CONSTRUCT SEDIMENT PONDS AND TRAPS.
8. GRADE AND STABILIZE CONSTRUCTION ROADS.
9. CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.) SIMULTANEOUSLY WITH
CLEARING AND GRADING FOR PROJECT DEVELOPMENT.
10. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL AND
MANUFACTURER'S RECOMMENDATIONS.
11. RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE THE EROSION
AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY'S EROSION AND SEDIMENT CONTROL STANDARDS.
12. COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAYS DURING
THE WET SEASON WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING OR EQUIVALENT.
13. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN SEVEN DAYS.
14. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS.
15. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BMPS REMOVED IF APPROPRIATE.
8/23/2024
4
3
2
1
PER CITY COMMENTS
PER CITY COMMENTS
PER CITY COMMENTS
PER CITY COMMENTS
REVISION
SURVEYED:
DAF
08/26/24
DESIGNED:
DAF
DAF
07/29/24
DAF
05/21 /24
DRAWN:
TJW, FEM
DAF
04/04/24
CHECKED:
DAF
BY
DATE
APPR
APPROVED:
LEVEL BOTTOM
SWALE SPACING DEPENDS ON SLOPE GRADIENT
2
2 MAX.
MAX. 1 �j
�1
NOTES:
1. CONDITIONS OF USE
I.I. REQUIREDAT:
1.1.1. THE TOP OF ALL SLOPES IN EXCESS OF 3HA V AND WITH MORE THAN 20 FEET OF VERTICAL RELIEF.
1A.2. AT INTERVALS ON ANY SLOPES THAT EXCEEDS THE DIMENSIONS SPECIFIED BELOW.
AVERAGE SLOPE
SLOPE PERCENT
FLOW PATH LENGTH
20HAV (OR LESS)
3-5 %
300 FEET
(10 TO 20)H:1 V
5-10 %
200 FEET
(4 TO 10)H:1V
10-25%
100 FEET
(2 TO 4)HA V
25-50 %
50 FEET
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. FOR SLOPES STEEPER THAN 2H:1V WITH MORE THAN 10 FEET OF VERTICAL RELIEF, BENCHES MAY BE CONSTRUCTED OR CLOSER SPACED
INTERCEPTOR SWALES MAY BE USED. THE DESIRED MEASURE MUST BE DESIGNED BY AN ENGINEER TO EFFECTIVELY INTERCEPT THE HIGH VELOCITY
RUNOFF TO A SEDIMENT POND OR TRAP.
Z2. CONSTRUCTION TRAFFIC OVER TEMPORARY SWALES SHALL BE MINIMIZED.
3. MAINTENANCE STANDARDS
3.1. DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE REPAIRED IMMEDIATELY.
lZ IF THE FACILITIES DO NOT REGULARLY RETAIN STORM RUNOFF, THE CAPACITY AND/OR FREQUENCY OF THE SWALES SHALL BE INCREASED.
UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS)
Alffiv.
STD. PLAN - 217.10
ciPUBLIC WORKS INTERCEPTOR SWALE PPR D 9/28/2018
�1` DEPARTMENT GAZ
rwoa. Aamm�:n.ro, DATE
SECTION A
2"-4" ROCK
2
L
A
L = THE DISTANCE SUCH THAT POINTS B
18" MIN.
A AND BARE OF EQUAL ELEVATION a�
BOTTOM OF DITCH
SECTION B
NOTES:
1. CONDITIONS OF USE
1.1. WHERE THERE IS CONCENTRATED RUNOFF FROM DISTURBED AREAS TO AND FROM SEDIMENT PONDS OR TRAPS.
1.2. TO CONVEY RUNOFF INTERCEPTED FROM UNDISTURBED AREAS AROUND THE SITE TO A NON -EROSIVE DISCHARGE POINT.
2. MAINTENANCE STANDARDS
2.1. ANY SEDIMENT DEPOSITION OF MORE THAN 6 INCHES SHALL BE REMOVED SO THAT THE CHANNEL IS RESTORED TO ITS ORIGINAL DESIGN CAPACITY.
2.2. THE CHECK DAMS SHALL BE EXAMINED FOR SIGNS OF SCOURING AND EROSION OF THE BED AND BANKS. IF SCOURING AND EROSION HAS OCCURRED,
AFFECTED AREAS SHALL BE PROTECTED BY RIPRAP OR AN EROSION CONTROL BLANKET OR NET.
UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS)
STD. PLAN - 217.40
c PUBLIC WORKS DITCH CHECK DAMS PPR D. 9/28/2018 1
'1` DEPARTMENT GAZ
vPer DATE
SCALE:
11'=301
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
HORIZONTAL:: NAVD 1988 NAD 991
� CITY OF
RENTON
DATU M
Planning/Building/Public Works Dept.
NFURR
\Cw NOINIEERING
\&RVICES, PLLC
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206 890 8291
'-` R-429005
0)
(17
0
C/)
��
t-,/
N
�J
F-
M,
l�
M
Q
J
lm
t-,/
N
rr
In
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
DEVELOPMENT ENGINEERINGAO%z
NJanders 09/16/2024
O
I-
Lu
U
a
DATE: PPPPPJ
GRANT PLACE TOWNHOMES 11/21/23 0-
1600 GRANT AVE S RENTON, WA 98055 FIELDBOOK: z
PAGE:
PARCEL 2023059052 DRAWING NO*
20069
TESC NOTES AND DETAILS SHEET: OF, �•
C2.1 28
O
N
O
r)
W
CW
G
O
z
O
W
U
J
n
z
a
O
U
W
Q
W
J
NOTE:
THE UTILITIES HAVE BEEN PARTIALLY UPDATED TO REFLECT AS -BUILT
CONDITIONS. ADDITIONAL AS -BUILT SURVEY REQIRED I I
TO OBTAIN INVERT ELEVATIONS ON STORM AND SANITARY SEWER.
0
30'
30' C1 294.77�
EG 294.37 g 5°la
EG 294.33
295.63
2 .57
,•4 J-
y.
'4 4
G y I Q S:3+5 81
0
97
20' WIDE TYPE C1 B DRIVEWAY APPROACH` .
PER RENTON STD PLAN 104.4, SIDEWALK
AT DRIVEWAY CROSSING SHOULD NOT ,...,
BE DEPRESSED AT LOCATIONS WHERE
LANDSCAPING IS MORE THAN 5 FEET WIDE
STREET NAME SIGN, ONE WAY SIGN
AND DO NOT ENTER SIGN A
SEE SHEET C3.2
30 15 0 30 60
SCALE: 1 INCH = 30 FEET
I
60' R.O.W.
CL
30'
NEW STREET LIGHT POLE
ALIGNMENT: GRANT AVE S
STA: 4+41.53
or
i
NE
1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N.7 R. 05 E,
W.M.
GRANT PLACE TOWNHOMES
TRASH COLLECTION
INSTALL WOOD FENCE ALONG
SOUTH PROPERTY LINE, SEE
ULTRA BLOCK RET. WALL.
"
20' PRIVATE ALLEY ACCESS
& PUBLIC UTILITY EASEMENT
STAGING (TYP)
TOP: 340.9
MAIL BOX (TYP) TOE: 340.0
WALL FACE TO BE 12AWAY FROM THE PROPERTY LINE .
TYP
SHEETS C3.1 AND C3.2 FOR DETAIL ( )
SEE DETAIL SHEET C3.2 TOP: 339.5
TOP: 302.7 TOP:
TOP: 316.7 PORTION OF PA =L 202305-901 �
TOP: 312.9 TOE: TOP: TOP: TOP:
OR SIMILAR TOE: 339.5
TOE:301.3 TOE :306.5
TOP:318.1 TOE:318.7 TOE:319.8 TOE:320.0
TOE:311.0 TOE:316.3 4 of
�'o �2 / ^
c�
W
o �,
� Q
`' N89°09'24"E
00
B
- -
'
- --�---00--o---N--�--}
- - - -- - I GRANT CIRCLE S.E.--
�� -��- -- -
-o --R -
o-�- - -
---�
c M
, mg, P1
gjmvp
MME;,��
INFIN't
•
Ax
\
\
'
60' .O.W.
G
4 ,
\
G2
OP: 3(
\h
TOE:3(
304.05
\303.93
304.01--
`L
\
GRANT AVE S\:` +
20' WIDE TYPE C1 B DRIVEWAY
APPROACH PER RENTON STD PLAN 104.4,
SIDEWALK AT DRIVEWAY CROSSING SHOULD
NOT BE DEPRESSED AT LOCATIONS WHERE
LANDSCAPING IS MORE THAN 5 FEET WIDE
O
O
o
X tY
w a_
i
I
31.5' PUBLIC 1/2 R.O.W.
1.5' R.O.W.
30' 5' DEDICATION
SIDEWALK I i
8' LANDSCAPE 3'
I EXISTING 18.0'
I SIDEWALK EXISTING
I CURB (TYPICAL) EXISTING 6
" 2% 1.50/1 �
Ix PAVEMENT
SAWCUT LINE
CURB I 4" THICK
d i 12" I CONCRETE
ISIDEWALK
GRANT AVENUE
CROSS SECTION A I
SCALE: 1'=10'
5 WIDE(MIN)
TRANSITION TO EX.
CONC. SIDEWALK
5' MIN. WIDE A.C. RAMP
EG
EG 294.33-� 9.69' -_ \
ASPHALT TRANSITION AT NORTH
END OF NEW SIDEWALK
SCALE: 1 "=10'
O O
16 � M
N
-
M - N �
° \ 1 N
°
o � 4.4% to --- 4,2 /o - - � �... rr-- ; [====I=L_=] "' •�" ,' .: L____T .
4.8/o
� -., ram___ t__M1_L •.d i _ _ � � __� m• a____ ____J .v• � ____ - ^ '�
1 _ 333.59 334.93 s°
)0.3% T \ o - - ° 318.41� �318.96 320.00 L 1 324.62 r� 325.70 ~ 325.95� 327.35 0 �0 I T 331.59 333.16a
TOP: 306.0 15.0 /0 315.11 1 BUILDING #2 BUILDING #3 344.23 i
T_ 303.4, 316.73 317.78 BUILDING #1 329.74 O 333.43 336.43 342.30 342.96 343..
•d •, o� �' 1ST FF= 1ST FF= 1ST FF= 1ST FF=
1ST FF= 1ST FF= 1ST FF= 1ST FF= 1ST FF= N 1ST FF= 1ST FF= 1ST FF= 1ST FF=
N d'
d
R
333.44
334.94
�- � `� � � P .,•'I 316.73 317.77 318.35 318.91 320.0 I - �� 324.61 325.70 325.95 327.35 33 331.59 333.31
T P: 306 9 2ND FF=
314.54 M o� 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF=
TOE: 306.8 v, 2ND FF= 2ND FF= 2ND FF= 2ND FF= 2ND FF= \
1 w 1 o � 326.08 328.08 328.08 328.08 330.08 333.77 335.27 335.27 336.77 w 341.57 343.03 343.03 344.56
��\0 20.6/° 1 325.74 326.26t-328.82334.93 334.93 334.69 Itl• 340.70 0
337.07
- I �.�o, I 327.74
\.• 'r �j3233207,o3.74 1.
.74 -3318.78 -235o2.-5501373.04%.84' 342.70 -
34,0
a
o
_a336.52 34314.814342.70'T
318 327.69 c" 339.72 A TOP3.43.1
420/° TOE: 341.731324 3215.9/'4.6°/o
4/°9
1.4iI f 340.29 3.0 /o
I
e3 • 329.52 330.62 334.51 338.02
323.61 �, a � o
�� 321.51 0 • 322.50 0 0 0 332.75J336.50 ,r �M 340.86
- v � - -- y� \ ` M i'' • o w ot333.61 336.40 341.22 �M 341.22
fOP: 30 .3 , \ eo I ao e1.4 - -- - - - - - - - - - - - 340
fOE: 301.7 T P: 312. o ° - - - - - - - - - 333.61 334.47 0
15.8 /o - � � 325.12 - - - � `�
\ 308.20 325.58 T� 328.01 BUILDING #7 334.34 'I N I 340.81
336.94 BUILDING #6 I '
\ 307 43 \ i 319.16 325.58 325.58
\ BUILDING #8 325.38 11ST FF= 1ST FF= 1ST FF= 1ST FF= I4 1ST FF- 1ST FF= 1ST FF= 1ST FF=
1 ST FF= 1 ST FF= 1ST FF= 1ST FF= 1ST FF= I . • ��� 322.61 323.80 324.02 325.81 330.35 331.80 331.80 333.47 I
\ . 314.90 315.92 316.10 316.60 317.57 2ND FF= 2ND FF= 2ND FF= 2ND FF= 0 33 2ND FF= 2ND FF= 2ND FF= 2ND FF= I
06.63 308.48 A o�Q 333.95 333.95 337.00 v 9 34'
\ i . 313.31 2ND FF= 2ND FF= 2ND FF= 2ND FF- 2ND FF= 331.85 340.19 341.55 341.55 343.08 342.75
- 324.73 325.92 325.92 325.92 327.57�V, 1 331.51 336.66 "' 332 339.86 331.80 333.46 7
1•0 w 313.54 0, 324.39 1 .1 316.60 327.23 323.80 324.42 325.81 333.41 330.38 E �337.71 ^b
314.88 315.92 3 6 0 317.57 322.61 - - - - ° - -
�.. �. �.- -
16.2/0 - - � � _ 1 _ -- da _ -
.I -r - ,'-' , . '.. .: ...' . ago r ---r - • --
T
r_ � .... _ °
1v vv
�- 331.80 4.19
_
- I IR 8+00 t 4' +- � o \ 7+00 �� 16
16 9+0 GRANT CIRCLE S.E. - - - - - -
- - - - - -
- -
313.92 318.62 325.56 333.53
d 0 C TOP:337.8
v
o �TOE:337.8
305.94 307.Oi / N 3 1, MAIL BOX (TYP)
k63 ck 306.60 `' 74� 20' PRIVATE ALLEY ACCESS SEE DETAIL SHEET C3.2 TOP: 341.2�
TRASH COLLECTION TOE: 339.3
STAGING (TYP) & PUBLIC UTILITY EASEMENT OR SIMILAR
NOTE:
NO WORKS SHALL BE DONE ON ADJACENT PRIVATE PROPERTY
UNLESS A TEMPORARY CONSTRUCTION EASEMENT HAS BEEN
RECORDED WITH KING COUNTY AND PROVIDED TO THE DEVELOPED
ENGINEERING PROJECT MANAGER FOR REFERENCE.
J415.49
TOE: 357.4
TOP: 343.0
TOP: 351.4 353.46
TOP- 358.0 TOP: 359.8
TOP: 360.1
TOE:342.3
TOE:350.9
TOE:355.4 TOE:356.9
TOE:357.2
TOP:362.1
350.49
355.43
IF353.72
o
TOE:360.7
348.72
356.54
-
-
TOP:363.1
_
0.8%' d
TOE: 360.5
-351.01
- 356.97
- TOP: 360.2
357.13 �o TOE: 357.3
0.48
M 352
g
354.99
c?
v
-
I
I G
343.00
348.57-
�`'-
p
a
- M
N
g
�5
tppo
pe42.63
359.19
360.70
362.19
357.30
i
I 357.87
352.53
BUILDING 44
359 62
I 363.68
3G2
1 ST FF=
1 ST FF=
1ST FF=
1 ST FF=
1 ST FF=
358
43.68
I 348.19
2ND FF=
349.75
2ND FF=
351.13
2ND FF=
352.61
2ND FF=
354.23
2ND FF=
TOP:359.3
`TOE:
°'O
357.98
359.52
361.03
362.52
364.01
N I
I 357.9
P: 43.0
I 357.43
TOE: 42.3
3G�
357.65
I
349.75
351.13
352.61
354.23
a'cb
355.67
10
344.97
-
- :- -
- -
d
"
i TOP: 355.7
TOE:
-
345.11
348.19
L_ •_J. L-- _";_J 4'
P171VATE ALLEY 1+db
w ---
-5.8
OF WALK 355.22
4' 346.01
348.25
349.53J
350.8,
I352.46
353.96
356
= 355.67
357.66
BUILDING 45
363.68
I
0 1 N 357.43
0
�4
: 34 .2 -34
1 ST FF=
1 ST FF=
1ST FF=
1ST FF=
1ST FF=
v
N
. in
106%
1-y 00
TOE:34.1
•I 348.25
1 349.53
350.87
352.46
353.96
�357.86
2ND FF=
2ND FF=
2ND FF=
2ND FF=
2ND FF=
357.99
359.48
360.98
362.52
364.01
4
.
359.62
sss
3 54
M • :
352.98
359.15
360.65
362.19
1
1 INSTALL WOOD
342' ; �
M
W3
a�
350.61 0
... o
�� w
359.03 FENCE ALONG
EAST PROPERT
3�Ogo
350.49
357.31
358.06
��
1 LINE, SEE LAND
TOP: 341.E
� .,,
M ''' 4.5%''
` �'.2.2 /o . 0.9 /o=
°
' 3.9 /o •
358.70 PLANS FOR DEl
TOE:341.4
v
350.37
353.39 89"09 29 E
356.79 11 .73
�� �°
' 347.42
,
351.01
353.67 355.01
-�
- J
\ PARCEL 326060-0000 INSTALL WOOD FENCE ALONG
HERITAGE VILLAGE CONDOMINIUM SOUTH PROPERTY LINE, SEE
��:raarx•rrr�r_ml
z
20' PRIVATE
J I
>_
ALLEY ACCESS
20' PRIVATE
d'
I I
3
ALLEY ACCESS
I
I 4 I w
I
16' ASPHALT
O
16' ASPHALT C
DRIVE LANE
NCRE E
WALK
o
=
CONCRETE
DRIVE LANE
4
ONE WAY
z
WALK
I ONE WAY
I
O
CEMENT CONCRETE
I
4' SIDEWALK
I
CURB
I
~
PEDESTRIAN CUBR
1.5%
I CURB
I
SLOPES
ULTRA BLOCK WALL
2%
1.5%
AS PER STD.PLAN-101
-
2%
I - o
5%
g;1M
VARIES
3'�MPX.
SLOPES
4" THICK 2:1 MAX
g.1 MPX
NOTE: PAVEMENT THICKNESS PER
VARIES NOTE: PAVEMENT THICKNESS PER
CONCRETE
TYPICAL DETAIL ON SHEET C3.0
2:1 MAX TYPICAL DETAIL ON SHEET C3.0
SIDEWALK
GRANT CIRCLE S.E. (PRIVATE
ALLEY)
GRANT CIRCLE S.E. (PRIVATE
ALLEY)
CROSS SECTION B
CROSS SECTION C
GRASSCRETE SERVICE DRIVEWAY FOR
STORM VAULT MAINTENANCE SEE SH. C3.2
d
.4 306.48
307.08
306.42 - ASPHALT PAVEMENT
305.97
a /^
EX. WATER METER TO BE
307.30 REMOVED AND CAPPED AT e. CONCRETE PAVEMENT
MAIN BY CITY FORCES UNDER d
307.09 °
SEPARATE PERMIT.
ELECTRIC TRANSFORMER, AND - - PROPERTY BOUNDARY
\ ' EG 307.78 TELEPHONE BOX TO BE ^^ RELOCATED AS REQ. - - - - - - -
EASEMENT LINE
TRANSITION AT SOUTH END OF NOTE: SEPARATE PERMITS
FROM UTILITY OWNERS - - ROW DEDICATION
NEW SIDEWALK REQUIRED
SCALE: 1 "=10' TRASH COLLECTION STAGING AREA
44+1 8-UNIT CLUSTER MAILBOX
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
Know what's below.
Call before you dig.
8I2312024
4 PER CITY COMMENTS
3 PER CITY COMMENTS
2 PER CITY COMMENTS
1 PER CITY COMMENTS
N0. REVISION
17
0
SCALE: 1'=10'
zl 20' PRIVATE
J ALLEY ACCESS
� j I 4' I
� I CONCRETE,
� I 16' ASPHALT I WALK
DRIVE LANE i o
7 ONE WAY
I �
FENCE CURB I
� 2% I 1.5%
3'� M SLOPES
NOTE: PAVEMENT THICKNESS PER VARIES
TYPICAL DETAIL ON SHEET C3.0
2:1 MAX
GRANT CIRCLE (PRIVATE ALLEY)
CROSS SECTION E
SCALE 1'=10'
T 4" HMA CL. 1l2 IN. COMPACTED DEPTH
1T0" AGGREGATE BASE 6" COMPACTED DEPTH
GEOTEXTILE
EG. GRADE
NOTE:
PAVEMENT GRANT CIRCLE SE TO BE CLEARED
FROM EX. TEMPORARY PAVEMENT
SECTION (TYP) AND TO BE REPAVED AS PER DETAIL.
SCALE: NTS
SURVEYED: SCALEVER_
DAF 08/26/24 DESIGN
a-30 ' HORIZONTAL- NAD 19 3/1991
DESIGNED:
1 -
DAF 07/29/24
DAF 05/21 /24 DRAWN: DAF
TJW, FEM
DAF 04/04/24 CHECKED: ONE INCH DUMAT AT FULL SCALE
DAF IF NOT ONE INCH
BY DATE APPR APPROVED: SCALE ACCORDINGLY
SCALE 1'=10'
LU
J I- 22'
�I
I 4' 15'
OI w
�I U)
� o
3:1 MAX. �
ULTRA BLOCK 0 i
RET. WALL I 1.5% VARIES
4" CONCRETE
SIDEWALK
CROSS SECTION F
SCALE 1'=10'
O
vugv
R
EARTHWORKS CALCS:
CUT: 431 CU YD
FILL: 1,892 CU YD
NET: 1,461 CU YD [FILL]
•
CITY OF
RENTON
Planning/Building/Public Works Dept.
INSTALL SPLIT RAIL WOOD FENCE
ALONG TREE PRESERVATION
TRACT PROPERTY LINE, SEE
LANDSCAPE PLANS FOR DETAIL
20' PRIVATE
ALLEY ACCESS
12'ASPHALT
w
w
4'
DRIVE LANE
4'
o
0
z
CONC
1
CONC
z
�
i
�
1.5% 1 2% � 2% 1 1.5%
NOTE: PAVEMENT THICKNESS PER
TYPICAL DETAIL ON SHEET C3.0
PRIVATE ALLEY
CROSS SECTION D
SCALE 1'=10'
0-
0 Uj
I�
w
3:1 MAX. �
w'~ 6' 4' 6'
= o 3:1 MAX.
i
z �
VARIES 1.5%
- -� �- ULTRA BLOCK
4" CONCRETE j RET. WALL
SIDEWALK I
CROSS SECTION G
SCALE 1'=10'
NOTE:
RESTORATION WITHIN GRANT AVE SHALL COMPLY WITH THE CITY'S OF
RENTON TRENCH AND RESTORATION STANDARDS. SEE DETAILS ON SCH. C3.2
O
N
U
H
H
C'7
a
J
N
�W uRR
EN6INEERIN6
SERVICES, PLLC
4715 142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
R-429006
W
2
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
O
DEVELOPMENT ENGINEERING
NJanders 09/16/2024
z
O
W
U
Q
GRANT PLACE TOWNHOMES
DATE:
11/21/23
�
1600 GRANT AVE S RENTON, WA 98055
FlELDBOOK:
PARCEL 2023059052
PAGE:
�
DRAWING N0:
20069
PAVING AND GRADING PLAN
I�
\J
SHEET: OF:
C3.0 28
O
N
1
1
W
I-
V J
5W
G
O
2
Z
O
I-
W
U
<
n
I-
Z
Q
It
0
T
CM
U
3
c
Z
0
U
I
io
S
LJ
M
<
Z
J
L_
FACE OF CURB
e
1f2'R I I VIM. - 124
I
T- TOP OF
D % 1n" R ROADWAY
--
try
c b1t- I
CEMENT CONCRETE
TRAFFIC CURB AND GUTTER
FACE OF ADJACENT CURB
I.612" J FLUSH WITH GUTTER
PAN AT SIDEWALK
RAMP ENTRANCE
i
1:12 - 1:24
\ i TOP OF
12" R. ROADWAY
C • t
1' - 6•
DEPRESSED CURB SECTION
AT SIDEWALK RAMPS
3B"
6' CEMENT CONCRETE
12' FR 1• R. SIDEWALK RAMP
VARIES OR LANDING
FROM
6"TOO 1 F
6'
_ 316• PRE -MOLDED
JOINT FILLER
CEMENT CONCRETE
PEDESTRIAN CURB
AT SIDEWALK RAMPS AND LANDINGS
- FACE OF ADJACENT CURB
-
SEE DEPRESSED CURB DETAIL THIS SHEET
124
TOP OF
1' 112' R. ROADWAY
r
_T- P E'
t D•
1'-6'
DEPRESSED CURB SECTION
AT RESIDENTIAL DRIVEWAYS ONLY,
FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 104.2
FACE OF CURB
FACE OF ADJACENT CURB
'
GUTTER SURFACE
P ► q
aA' i��•'
PREMOLDED
J 01 NT FILLER
1r
o irr
5112" 1'
1n•rz � j -� •R.
• 1 j TOP OF
I ROADWAY
•/ t
_1
E FULL -DEPTH 1" R. I
I 81l4' _
EXPANSION JOINT
I*R, CEMENT CONCRETE
TRAFFIC CURB
DEPRESSED CURB DETAIL
AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS
GENERAL NOTES:
1. See standard plans 102 and 101.1 for curb expansion and contraction joint spacing.
2. Expansion Joint shall be full depth, 3/8" (in.) premolded joint filler.
3. For Depressed Monolithic Driveway Curb & Gutter Section, see Standard Plan 104-2
STD. PLAN - 101
,• PUBLIC WORKS DEPARTMENT , PCEMENT CONCRETE CURBS PP �'ED
M
L
8 MIN. VARIES ISEE NOTE 7) V MIN.
ISEE NOTE 8)
(SEE NOTE 8)
10 LF OF PAVED
DRNEW IY REOUIRED
XPANSION JOINT ITYP.)
ISEE STD. PUN 102)
CI
CI
SII
0
o
SEE NOTE 5
Y
Z
3
HH
VENT
NCRETE
EWALK
/ SEE NOTE CEMENT CONCRETE
RAMP LOPEWITH TYP.)
J// B CURB &GUTTER
SLOPE (TYPJ (SEE NOTE 3)
3I8• CONTRACTION JOINT )TYP )
(SEE STD. PLAN 102) PLAN VIEW
(TYPE C3 SHOWN, C1 & C2 8 C-MAX SIMILAR)
(SEE NOTE 9)
VARIES
(SEE NOTE 10) 8.35, MAX. SEE NOTE 81TYPT
10' MIN. 10" MIN.
CEMENTCONCRETE 10-MIN.
SIDEWALK O 318'EXPANSION JOINT (TYP.)
SECTION A (SEE STD. PLAN 102)
slDswr
DIFFERENCE IN SLOPE 112' R (TYP.)
DRIVEWAY
NEGATIVES
SHOWNEX
DRIVEWAY WI SITNE SLOPE (SLOPE SHOWN EXAGGERATED) 1.5%
-
y C DRIVEWAY ,
D 10' MIN.
RELATNE SEE DETAIL ON STD PUN 2
(SLOP
SERATED)
SECTION OB
sp
CEMENT
CONCRETE
SIDEWALK
CEMENT CONCRETE
CURB & GUTTER
(SEE NOTE 3)
AIL. STD. PLAN 104.21
TYPE C2 - ISOMETRIC VIEW
For NOTES see STD. PLAN 104.2
ti Y o� STD. PLAN - 104
PUBLIC WORKS CEMENT CONCRETE DRIVEWAY
DEPARTMENT ENTRANCE -TYPES C1, C21 PPRO D:
�NTo$ C3, and C-MAX
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N.7 R. 05 E, W.M.
GRANT PLACE TOWNHOMES
r-aEE NOTE2 /8'R X 5/B"D DUMMY JOINT SEE NOT'E2
_p• 2'_p• /b
I I
l
3/8• PREMOLDED JOINT FILLER (T)-P) I
J L _--
5" (6 5'
PLAN VIEW
FACEOF CENTERLINEOF
CURB+_ FRAME d GRATE
FRAME AND GRATE - NOT INCLUC ED
1/2' R. I• R'MATCH ROADWAY INCURBf3T. ANDOUTTBIOITEM
SLOPE
c 1• R• RECESS
ROADWAY
P �
ADJUSTMENT SECTION-N(Tr1NCLUMD
►' : ► ' IN CURB AND GUTTER BID ITEM
• CATCHIlASIN-NGT INCLUDED
u • IN CUFA MID GUTTER BID FTSM
• ,a
CWEW CONCRETE
CURB AND GUTTER
SECTION AOK�/I
GENERAL NOTES: -1 '
1. The intent of this design Is to facilitate the removal' ;
of a catch basin with minimal disturbance
of the Curb.
2. The expansion Joints of the
adjacent sldewalk shall
be -adjusted to be In -
line wllh these curb
expansion Joints.
f1 U�`' I lSOFTC VIEW
1r ,- Ali
CEMENT CONCRETE CURB SM. PLAN - 101.1
PUBLIC WORKS PRO D:
+ + INSTALLATION AT
DEPARTMENT CATCH BASINS
DA .
CELExr
CONCRM
SIDEWALK
NOTES
1. When a driveway width exceeds 15 fee;, construct a full depth
DEPRESSED f1LONOUTKC
' CURB 4 GUTTER
(SEE DETAIL THI S SHEET)
TYPE C2B - ISOMETRIC VIEW
(COMMERCIAL, WITH BUFFER)
CEMENT CONCRETE
CURB A GUTTER
(SEE NOTE 3)
expansion joint wtth 3B• Joint filler along the driveway tans lines
(see aid. plan 102). Construct expansion joints parallel with the ,00 SEE oEP11FssPc QJRB DETAa
centerllne as required at 15' maximum spacing when driveway CONTRACT.ONxXT1T at! ON r•IsSMSET
widths exceed 30'. atDttiAl4tm sttr r
�I •? opor
R TROADWAY
2. See std. plan 102 for sidewalk details
3. Curb and gutter shown, other curb designs may be specified. •• ' •T �.
See std. plan 101 for curb details I_ ' . '• • , •. 1
•
4. Hal used 7�_-`�'
r-o' i'-r
I
5. The engineer will design all driveways to Indude elevations at all Hutt osliff"Y LaQrtuoO4AL OaANSION
points marked with symbol 'X'. All elevations are at the back of
ao1NTa OVAL BE FULL DEirH
Curb top on uphill side. 0 86EO MONOLITHIC CURB & GU"rER DETAIL
6 Nat used
7. For Driveway Widths see DRIVEWAY STANDARDS
(See NOTE 10) The expansion joints (see sld plan 102) shall be
spaced as shown In the corresponding Isometric View.
8, Slopes shall comply with sections R303.2.1 or R303.2.2 or --FACE OF ADJACENT CURB
R3032.3 of the Revised Draft Guidelines for Accessible Public 1'
Rigbts-of--Way of November 23, 2005 (PROWAG). ` y
9. Curb returns for any Type C-MAX Driveway may be approved on
a case -by -case basis. ?. ► 1'R ��VJWAM
.�R ► P,
10. STREET STANDARDS = Renton Municipal Code (RMC) C o,
Title IV Development Regulations o e •_
CHAPTER 6 STREET AND UTILITY STANDARDS a o • 'a
Section 4-"60 STREET STANDARDS DEPRESSED CUM DETAIL
AT f EBICENT1AL ORCOM111lRCIAL DIVVMYS. MIO ALLEYS
DRIVEWAY STANDARDS - Renton Municipal Code (RMC)
Title IV Development Regulations 0& way Exelmple: TYPE C18
CHAPTER 4 R=Reekiard d C•Cotrim ral --%'
CITY-WIDE PROPERTY DEVELOPMENT STANDARDS 1KRrlberofLarim -�
Section 4-4-M PARKING, LOADING AND DRIVEWAY (MAX"A Lsne Cornmemmeq
REGULATIONS Bil,"NOBuffer -
PUBLIC WORKS CEMENT CONCRETE DRIVEWAY ),`. PLAN - 104.8
DEPARTME1N'f ENTRANCES - NOTES AND DETAILS ivy/
Know what's below.
Call before you dig.
8/23/2024
4 PER CITY COMMENTS
3 PER CITY COMMENTS
2 PER CITY COMMENTS
1 PER CITY COMMENTS
IN
REVISION
s RAISED EDGE DETAIL 1'-0- 6-1 SIDEWALK
LEVEL �.J 1� EXTEND SIDEWALK TRANSVERSE 1'-0• 1'-0' &8•, N) PREMOLOED JOINT FILLER
ire (IN) R I JOINTS TO INCLUDE RAISED EDGE TYPICAL WHERE APPLICABLE
ROU DNG 2�-U% i 1W(IN)R.(TYP.)
' I FOR CURB DETAILS
••' . . tr 1.5% SEE STD PLAN 1011
'EXISTING
1• QN} R. a .: a C�it� �J r .._ ~ .. - }r• - CRUSHED ROCK BASI
r o l t•. ,:.
SEE RAISED EDGE I
r';
1'•0• SIDEWALK DETNL - THIS SHE CALUNDERUNDER CRUSHED SURFACING TOP COURSE (CSTC)
ALL CLn MIN. SIDEWALKLK OMPACT TO 95% MODIFIED PROCTOR
yioPEs7 WITH RAISED EDGE NHS REQUIREMEW WANED BY
ENGINEER) TYPICAL UNDER ALL CURB,
12• (IN) R. (M.) GUTTER & SIDEWALK CSTC UNDER
`U% .�. ;, FOR CURB DETAILS CURB a GUTTER TO BE 6•THICKNESS OR
13% SEE STD PLAN HIT MATCH EXISTING ROADWAY CRUSHED ROCK
1J 611 -� BASE, WHICHEVER IS GREATER (TYP. FOR
aH�-K71'g • ' _ ALL CURD 6 GUTTER).
M •• • •• FINISHED GRADE /• (IN) BELOW
P 1 TOP OF CONCRETE SURFACE
2'-W SIDEWALLc
ADJACENT TO CURB MIN.
Rou DING 1?(IN)R(iYP.)
-�, FOR CURB DETAILS
-2.0% a 7SX _ SEE STO PLAN 101
BRIDGE OR PEDESTRIAN d' • --- _y`� �~ r•
RAILING -\�-• •.
FORcuRBDETAILS ADJACENT TO CURB
BARRIER -SEE
SIDEWALK SEE STD CPLAN URB DETAILS
(STEEP FILL SLOPES)
CONTRACT PLANS / ALL OR BARRIER
! I 1Ir (IN) R. (TIP-)
FLUSH
SIDEWALK
• • • IrT N) R
VERTICAL WALL
-
SEE DETAIL 01Wt PREAIOLDED
JOINT FILLER
ADJACENT TO CURB AND RAILING OR WALL e• MO
PRQADLDEO
JOINT FILLER
FOR SIDE BUFFER STRIP
TREATMENT SIDEWALK SIDEWALK ADJACENT TO WALL DETAIL
SIDEWALK (SEE NOTE 10)
SECTIONS 1/2• (IN) R
1 (TYP) FOR. CURB DETAILS
MIN. SEE STD PLAN 101 .'
GROOMED FINISH
ORMATCHE70ST1NG
' p.Y.. . 4-WIDE,SMOOTH
TROWELED PERIMETER
FINISHED GRADE 1' (IN) BELOW TOP OF CONCRETE (�/
SURFACE FOR PLANTING -FLUSH IF PAVED Q• Q' I ;,�,, to (CURB fj'' :;\ CEMENT CONCRETE CURD
(CURB AND GUTTER SHOWN)
ADJACENT TO BUFFER STRIP FOR cuRe DETAILS
d- ti SEE STD PLAN 101.
i_ 1r8• TO lie
NOTES
1. Four feet of the sidewalk width shaA
be the minimum pedestrian COMRAcnOH JONT ' • '
accessible mute (PAr� free of vertical 4 rN SIDEWALKONIY a ► �� to '•
and horizontal obstructions. Gratings, �` • " • R 'r
Access Covers, Junction BDKa's FULL -DEPTH EXPANSION JOINT IN BOTH
Cable Vaults, Pull Boxes and other �-
•••,�� _ CURB AND SIDEWALK (SEE STD PLAN 10L1)
appurtenances within the sidewalk C CONTRACTION JOINT
must be flush with surface, and match -re
grade of the sidewalk. JOINT AND FINISH
. we DETAIL • . . t► �
2. Monolithic Cement Concrete Curb and A •� ' +�, Jb'�
Sidewalk Is not permitted in new For other referenced NOTES see •� .p ,
constnJction. When replacement work STD PLAN 104.2.
necessitates a Monolithic Cement ��
Concrete Curb build per WSDOT ,PRE FILLER
FLz
Standard Plan F-30.10-03. Paved surfaces must comply with . E. FULL -DEPTH
3. Concrete to be 4,000 P51. STD PLAN 102.1 as applicable,
EXPANSION JOINT
STDPUBLIC WORKS CEMENT CONCRETE
• PLAN - 102
DEPARTMENT SIDEWALK FPRO,rED:
iA 7
�
`- run
TlorrEMerIa.LlDeawellwlLKlluars) _ _
_ v_An�staTatlatan _ _
a.1.. I
10 LF OF PAVED
1
DRN'EV110 REDI:gEO
18'EAPANSIONJOM lTY'P
'SEE ETD PLAN 102T
SIa•TSIMifIONbNt1tYPJ I
(i rIQ KA711�
CEWEM
1 CONCRETE
'
SIDEWALK
SEE NOTES
1aV C'EAERENC! M S.OPE YAX-
CAWEWAT w AELAI
!Ef:ATIVE 5<DPE 141
SNO,vN ERAGCEMI
CONSTRUCTION JOINT -
SEE NOTE I CEMENTCONCRETE
RAW WITH 124 IV (B) Cuu a ouTTER -
SLOPE (TYP) / (SEE NOTE ]1
(
i&' CONTRACTION JOINT LrYP I
ISEE STD PLAN lam
PUN VIEW
(TYPE C3 S140014114 Cl a C2 IS C-MAX SIMILAR)
(SEE NOTE 9)
E n NA1t
S=r Ml* •
•
01A1 1P'YM
DEPHESSEO LURA A GL.' TER
��� Ic•w
\ ae• E}PANSI]N JOM•!TTJ
(SEE NO7EA
SECTION O E M 'LANtT, TYP!
SMWA.K WIDTH \
-oTYNlYMTW SLOPE IS Oft SNOWNEA:GERA•W
tall Ia.W \
lee
4.• :. ••4. •
, de.ENMY
to' W K1a
SE
0
For NOTES see STD PLAN 104.2
STD. PLAN - 104.4
PUBLIC WORKS CEMENT CONCRETE DRIVEWAY
DEPARTMENT ENTRANCE - TYPES C1B, C2B, PP
'E:D.
040,11
C3B, and C-MAXB (WITH BUFFER) t
SURVEYED:
DAF
08/26/24
DESIGNED:
DID
DAF
07/29/24
DAF
05/21/24
DRAWN:
TJW, FEM
DAF
04/04/24
1 CHECKED:
DAF
BY
DATE
APPR
APPROVED:
SCALE:
i 9#=30►
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL, NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
1" X 6" PLANKS (SECURED BY TWO GALVANIZED NAILS)
2' X 6" CAP
2" X 6" STRINGERS (2 EACH)
6" X 6" POST
(PRESSURE TREATED) 2" X 6" CAP
8'-0" 6" STEP MAX
WHEN NECESSARY
1" X 6" PLANKS FOR GRADE CHANGE
It
C1)CONCRETE FOOTING
FINISH GRADE
CD
o
KR
16" TYP GRAVEL BASE (TYP)
6' WOOD FENCE EXISTING SUB GRADE
NTS
NOTES:
1. 6' X 6" POSTS NEED TO BE PRESSURE TREATED FIR.
2. ALL OTHER WOOD MEMBERS TO BE CEDAR.
3. ALL NAILS USED SHALL BE GALVANIZED.
J
d
KEYSTONE FACING
TENSAR UX
1400 GEOGRID
FREE -DRAINING
GRANULAR FILL
(SEE REPORT)
FILL COMPACTED
TO 95% OF
ASTM D1557
(MODIFIED PROCTOR)
NOTE:
FILL MATERIAL FOR THE BERM CONSIST OF COARSE, PIT -RUN
GRAVEL OR CRUSHED ROCK THAT IS COMPACTED TO 95 %
OF THE MAXUMUM MODIFIED PROCTOR DENSITY. THE FILL
MATERIAL SHOULD HAVE A GRADATION AS FOLLOWS:
SCREEN SIZE PERCENT OF MATERIAL PASSING
3 INCH 100
3/4 INCH 45-80
40 5-20
200 <5
NFURR
KEYSTONE RETAINING WALL VE
NOT TO SCALE
'-�_ CITY OF
RENTON
Planning/Building/Public Works Dept.
\SERVICE.% PLLC
4715 142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
O
co
,
�J
co
a
J
N
CO
C�
t)
-J
N
rr
0-
TM
R-429007 UJ
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
DEVELOPMENT ENGINEERING Z
Wanders 09/16/2024
O
LLI
U
Q
DATE: J
GRANT PLACE TOWNHOMES 11/21/23
1600 GRANT AVE S RENTON, WA 98055 ooK:
PAGE:
PARCEL 2023059052 PAGE. z
DRAWING NO:
20069
DETAILS SHEET: OF:
C3.1 28 �J
Q DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
N
1
0
LU
V i
LU
75
O
z
O
I-
W
U
/Q
n
I-
z
Q
rr
0
N
U
U
W
M
Z
J
6-
I
SEE STANDARD PLANS 110, 110.1, 110.2, AND 111 FOR PAVEMENT
RESTORATION REQUIREMENTS
SURFACE RESTORATION AS I
SPECIFIED IN CONTRACT DOCUMENTS
12" MIN. EXISTING PAVEMENT SURFACE
I
NEAT LINE TRENCH
6" MIN., SEE NOTE 4
"CRUSHED SURFACING TOP COURSE" PER
WSDOT STD. SPEC 9-03.9(3), COMPACTED
TO 95% OF MAXIMUM DENSITY
"CRUSHED SURFACING TOP COURSE" PER
WSDOT STD. SPEC 9-03.9(3), "BANK RUN
GRAVEL FOR TRENCH BACKFILL" PER
WSDOT STD. SPEC 9-03.19, OR "GRAVEL
BORROW" PER WSDOT STD. SPEC 9-03.14(1),
COMPACTED TO 95% OF MAXIMUM DENSITY
BENCH AS NEEDED FOR
SHORING SYSTEM WHEN
DEPTH IS 4' OR GREATER
kj'
PIPE
PIPE ZONE BEDDING AND BACKFILL
PER STD. PLANS 220.00 AND 220.10
SEE NOTE 1
UNPAVED AREAS I PAVED AREAS
NOTES:
1. SEE WSDOT/APWA STANDARD SPECIFICATIONS SECTION 2-09.4 FOR
MEASUREMENT OF TRENCH WIDTH.
2. EXCAVATIONS OVER 4' DEEP SHALL COMPLY WITH THE SAFETY STANDARD
DESCRIBED IN CHAPTER 295-155 PART N OF THE WAC.
3. MAXIMUM BACKFILL DEPTH ABOVE PIPE SHALL NOT BE EXCEEDED, AS
DETERMINED BY PIPE MANUFACTURER.
4. IN PAVED AREAS, IF PIPE HAS LESS THAN 3' OF COVER, USE "CRUSHED
SURFACING TOP COURSE" FOR THE ENTIRE BACKFILL DEPTH ABOVE PIPE ZONE.
5. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 220.20
URI
PUBLIC WORKS TYPICAL TRENCH AND BACKFILL PPR D9/28/2018 DEPARTMENT GAZ
P"bfiCWorks Admi1js W1 DATE
370
365
360
355
350
345
340
335
330
325
320
315
310
305
300
295
290
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N.7 R. 05 E, W.M.
GRANT PLACE TOWNHOMES
6" X 6" PO'
(PRESSURE TREATE
1" X 6" PLANKS
6" X 6" POSTS
ALL OTHER WOOD MEMBERS TO BE CEDAR.
ALL NAILS USED SHALL BE GALVANIZED.
6' WOOD FENCE
NO SCALE
:45
^4LVANIZED NAILS).
RS (2 EACH)
STEP MAX.
CESSARY FOR
)E CHANGE
CONCRETE FOOTING
FINISH GRADE
BASE (TYP.)
L/�IJIIIYV JVU GRADE
57 5fir
301/2"
0 ❑
D• ❑
FRONT VIEW
vital''m Cluster Box Unit - Type I
45"
SIDE VIEW
28 1/2"
PEDESTAL
1
Ct"
17'
PEDESTAL BASE
BOLT PATTERN
DOOR CHART
000RmR alwwlow(xe
NOTES: 10'.AIOCEL itti�fk�A1-b/�r
17PAR'CEL I I"4k12-13/1r
1. This unit is approved for USPS and private applications. I40pICIS� vital �' C1llSTER BOX UNIT
OUIGOMGSLOT 4k11r
2. Decorative mailbox accessories sold separately and are LISPS Approved
products.
3. Pedestal should be installed with included Rudder Pad; Residential and Commercial M cm R�
mounting hardware not included, refer to installation manual for Mailboxes 49-N
p 4"
recommendations. - BY
4. Florence "F" series CBU is Officially Licensed by USPS: GcMalllboxes.com °`�"'"'"GNUh16Bt DRAWN BY
License#CDSEQ-08-B-0012 800-427-9612 1570,13 S AFD
$94 North Main Street, Orange, CA 92869
......... ...a................:.. .............. ................. :.......... ...................... :................. I............ _..:.
...... _......I...._..........:............._.I..._...._...._.:...... ..._....{......... _ ....:__ ._....... ...._.._... _. _:................L...............................I..._._._._.._.._.._.._.._.... a.. _. _... _...:.. .................... ..._... _........_.......I........ _.... .:....... _._.... .. ....... .:......_..._....
_..FGBOTOF.._.
THE RET. WALL
N
J +
STA. 5 94.71
__..... .._. __............._._.:........._.._.:.. _. ._..__. _.. .......... _ _.
...... �_-ELEV:357:20_.
FG BOT OF
THE RET. WALL L'-LI
................................................. _................ LEV 351 2
................................................................................................... ....STA• 5+18.00 :. .
'moo, E 0
_......................... _....................... ..._....... _... ...................... ........ :...... ............................................ ......__......_........._................ ..... ............................
FGT POF:................._.............:......._.......
THE F
ET. WALL
....... ..... :......................
........... :...............................
..:.... ....STA:.
+57.21......... :................
........
.........
ELEV:
324.47
l
td'IJl IT dF'tHE
ft WALL'
STA: 4+37.99
:...................
FG TOP 0
ELEV: 336.00
.............. ................
........ ........................
THE RET:
ALt ....... _..:...............................................................i.
........ .............
............. .............
............. ............. ............. _ ............. I
STA:1+48.
9
�'
ELEV:317.4
_
_.....__._._.........
........................................................
....
_
�...:.....
..
"'
............ TOP OF............................................................
........
........ ....
.............................................
.............
............. .............
............. .............
.............
I ... ..... _
THE ET. WALL
EG BOT OF THE RET. WA
L
ST :0+46.93
STA:2+23.50
ELV:303.84
......................
.............. ............. J...
ELEV:319.T1...............................................................................................-.....
..
..... .
. L
EG BOT OF THE RET.
WALL
o
1+35..54
......
.......................... .... lz........................
..
ELEV:314.37J
a �
...........................................................
w
....
EGGBOT OFTH RET. WALL . .................
<a STA:0+42.42
:ELEV:301.58
Q...:.......... ........ .....................
.
LU
0_
0+50 1+00 1+50 2+00
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
Know what's below.
Call before you dig.
2+50
NORTH PL BORDER FENCE SECTION
V.. 1 "=1 O' H: 1 "=30'
3+00
8/23/2024
3+50 4+00 4+50
4 PER CITY COMMENTS
3 PER CITY COMMENTS
2 PER CITY COMMENTS
1 PER CITY COMMENTS
NO. REVISION
5+00
5+50
SURVEYED:
DAF
08/26/24
DESIGNED:
DAF
DAF
07/29/24
DAF
05/21/24
DRAWN:
TJW, FEM
DAF
04/04/24
CHECKED:
DAF
BY
DATE
APPR
APPROVED:
J/J
370
365
360
355
350
345
340
335
330
325
320
315
310
305
300
295
290
6+00 6+22
SCALE:
1 "=30'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
SHRUB MASS
C)
C)
C)
t'J
N
LJ
co
co
a
J
GRAVELROADBASE
VAULT ACCESS GRASSPAVE DETAIL
!jCza W1771 AC4X0 L44�lS AID
4F7ER PAT07-!ice
5
4"
uMo., N,1 ii � - 82455 C4P
3',4.GC�.G ...• ..•
f::�•.:';. �--GOMPAC E`D ELEI/.4T/Ort/
1:' .I SAND
a Zi ECT ,51CKF/LL
SEGT/C�c/ Jcni C29M194cr/av
NOTE.
1. STANDARD MONUMENT CASE AND COVER WASHINGTON STATE DEPARTMENT OF HIGHWAYS
1976.
2. THE CASTINGS SHALL BE GRAY-iRON CASTINGS, ASTI4 DESIGNATION A-48, CLASS 40.
THE COVER AND SEAT SHALL BE MACHINED SO AS TO HAVE PERFECT CONTACT
AROUND THE ENTIRE CIRCUMFERENCE AND FULL WIDTH OF BEARING SURFACE.
3. WHEN THE MONUMENT CASE AND COVER ARE PLACED IN CONCRETE PAVEMENT, A CEMENT
CONCRETE BASE WILL NOT BE NECESSARY.
4. SEE CITY OF RENTON SUPPLEMENTAL SPECIFICATION SECTION 7-05.3(1) FOR
ADJUSTMENTS TO GRADE.
ZEE
INEERING
RVICES, PLLC
4715 142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
CITY OF
RENTON
Planning/Building/Public Works Dept.
NOT TO SCALE
N
T
C)
1
N
0-
Monument Case & Cover
ADOPTED
U CITY OF RENTON
+ + STANDARD PLANS
LST DATE:1•Feb-89
DWG NAME: HR-04 SP PAGE: H031
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
DEVELOPMENT ENGINEERING w % z
74
NJanders 09/16/2024
O
LU
U
Q
DATE: J
GRANT PLACE TOWNHOMES 11/21/23
1600 GRANT AVE S RENTON, WA 98055 ooK:
PAGE:
PARCEL 2023059052 PAGE.
DRAWING N0: L
20069
DETAILS SHEET: OF: % r�
C3.2 28 �J
CD
0
LU
7
30 15 0 30 60
SCALE: 1 INCH = 30 FEET
EXIST STORM DRAINAGE STRUCTURE TABLE
ID
DESCRIPTION
RIM ELEV
PIPE INVERT
STATION
OFFSET
12" (W) LCPE IE=303.89
CB #2
TYPE I GRATE
EL 307.56
12" (E) LCPE IE=303.89
9+92.54
12" (N) DRAINI.89
8.764E
CB #3
TYPE I GRATE
EL 309.41
12" (W) LCPE IE=305.00
9+80.14
8.685L
CB #4
TYPE I GRATE
EL 340.60
12" (NW) RCP IE=337.92
6+00.30
10.703L
12" (E) LCPE IE=286.71
12" (W) REINFORCED CONCRETE IE=286.61
EX SDMH-1
TYPE II -SOLID LID
EL 294.51
12" (N) EX CMP IE=290.01
3+14.80
12" (NE) EX CMP IE=290.16
5.016E
12" (SE) EX CMP IE=287.21
12" (E) LCPE IE=302.54
10+09.06
EX. CB #1
TYPE I GRATE
EL 306.95
12" (N) LCPE IE-302.54
10.824E
12" (NW) LCPE IE=341.60
5+45.00
EX.CB #6
TYPE I GRATE
EL 345.08
12" (E) LCPE IE=341.60
14.654L
EX.CB #7
TYPE I GRATE
EL 354.82
12" (W) LCPE IE=349.02
1+18.16
0.970L
12" (E) LCPE IE=300.63
0+82.6312"
EX.CB #8
TYPE I GRATE
EL 303.51
(S) LCPE IE=300.63
9.047L
12" (E) LCPE IE=312.18
1+64.76
EX.CB #9
TYPE I GRATE
EL 315.69
12" (W) LCPE IE=312.18
9.050L
12" (E) LCPE IE=315.99
2+51.50
EX.CB #10
TYPE I GRATE
EL 319.95
12" (W) LCPE IE=315.99
9.019L
12" (E) LCPE IE=323.97
3+54.6312"
EX.CB #11
TYPE I GRATE
EL 327.12
(W) LCPE IE=323.97
9.096L
12" (W) LCPE IE=332.19
4+61.0812"
EX.CB #12
TYPE I GRATE
EL 335.01
(E) LCPE IE=332.19
8.799L
12" (SE) LCPE IE=336.82
4+99.46
EX.CB #13
TYPE I GRATE
EL 340.48
12" (W) LCPE IE=336.82
8.262L
12" (E) LCPE IE=288.17
EX.CB #14
TYPE II-48" 0 GRATE
EL 297.71
12" (SE) LCPE IE=288.37
0+50.85
12" (W) LCPE IE=288.17
16.247L
12" (SW) RCP IE=312.67
9+45.8212"
EX.CB #15
TYPE I GRATE
EL 317.65
(E) RCP IE=312.67
56.554R
12" (W) RCP IE=323.03
8+42.7112"
EX.CB #16
TYPE I GRATE
EL 325.70
(E) RCP IE=323.03
54.675R
12" (W) RCP IE=332.34
7+39.3712"
EX.CB #17
TYPE I GRATE
EL 335.01
(E) RCP IE=332.34
54.830R
12" (W) RCP IE=337.59
5+64.0312"
EX.CB #18
TYPE I GRATE
EL 341.06
(SE) RCP IE=337.59
32.526R
12" (W) LCPE IE=288.52
0+64.41
EX.SFMH#1
TYPE II-72" SOLID LID
EL 300.76
12" (S) LCPE IE=290.82
9.834L
NOTE:
STORM FACILITIES HAVE BEEN INSTALLED UNDER AN EXPIRED PERMIT
AND REFLECT AS -BUILT CONDITIONS.
SURVEY IE AND RIM ELEVATIONS ARE PROVIDED FOR THE
REFERENCE ONLY, USE STRUCTURES TABLE FOR THE PROPOSED
FINAL ELEVATIONS.
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT:
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
EX.SFM
EX.CB #14
RAISE EX. MH RI
WITH ONE 2' SECTION
I0 30'
30' EX 16LF 12" LCPE @ 2.2
\EX SDMH4--/
EX 34LF 12" LCPE @
EX 34LF 12" LCPE @ 40.
1.
.4
nnnnnc+�n I �n��ln
Know what's below.
Call before you dig.
GRASSCRETE SERVICE DRIVEWAY FOR
STORM VAULT MAINTENANCE
ASPHALT PAVEMENT
CONCRETE SIDEWALK
EX STORM DRAIN PIPE
EX TYPE 1 CATCH BASIN
EX TYPE 2 STORM DRAIN MANHOLE
8/23/2024
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
PER CITY COMMENTS
PER CITY COMMENTS
PER CITY COMMENTS
PER CITY COMMENTS
4LF 12" LCPE @ 9.71 %
CB #1
o
F.'Tl"kqffi •.
NOTE:
THE UTILITIES HAVE BEEN PARTIALLY UPDATED TO REFLECT AS -BUILT
CONDITIONS. ADDITIONAL AS -BUILT SURVEY REQIRED
TO OBTAIN INVERT ELEVATIONS ON STORM AND SANITARY SEWER.
PROPOSED IE AND RIM ELEVATION TAKES PRECEDENCE OVER
SURVEY DATA.
87LF 12" LCPE @ 4.39%
RELOCATE EX. STORM PIPING
FROM EX.CB#1 TO CB#5
SSMH-A (CENTER STRUCTURE)
TRIM=315.57
CTR CH.=303.42
STORM DRAINAGE NOTES
ALL RIM ELEVATIONS CALLOUTS SHOWN IN THE DEVELOPMENT ARE EXISTING
OELEVATION. THE FINAL RIM ELEVATIONS ARE SHOWN IN THE STRUCTURE
DRAINAGE TABLE ON THIS PAGE.
PORTION OF PARCEL 202305-9013
PARCEL 326060-0000
HERITAGE VILLAGE CONDOMINIUM
ACO SLOTTED STEEL GRATE
W/QUICKLOCK ASS'Y.
TACK COAT FACE OF ---
CUT AND EACH COURSE
4" HMA
6" COARSE FILL
#3 REBAR CONTINUOUS (TYP)
SEE STORM PLAN
AND/OR UTILITY PLAN
FOR CHANNEL INVERTS/SLOPE(S).
#3REBAR@6"OC
ACO FRAME MESH STEEL
12" TRENCH DRAIN K300 CLASS B
POUR IN PLACE CONC. BASE
51/2 SACK MIX
4000 PSI @ 28 DAYS
I. DMOF- OTVILL DC r-VUTCCU
AGAINST COMPETENT NATIVE
MATERIAL OR STRUCTURAL FILL.
NEW STRUCTURAL FILL, COMPACT 2. ALTERNATE TRENCH DRAIN
(ASTM D1557) SPECIFICATION MAY BE SUBMITTED
NOTE:
ALL STORM SYSTEM
FACILITIES UPSTREAM
EX.SDMH-1 ARE PRIVATE.
SURVEYED:
DAF
08/26/24
DESIGNED: DAF
DAF
07/29/24
DAF
05/21 /24
DRAWN:
TJW, FEM
DAF
04/04/24
CHECKEDDAF
BY
DATE
I APPR
I APPROVED:
FOR REVIEW AND APPROVAL.
FORMED IN PLACE TRENCH DRAIN
NTS
SCALE:
1 "=30'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
Adoftk
tuCITY OF
RENTON
Planning/Building/Public Works Dept.
CONSTRUCTION NOTES
1O CONTROL STRUCTURE - SEE DETAIL SHEET C4.3
OWATER QUALITY CONTROL STRUCTURE - SEE DETAIL SHEET C4.3
EX STORMWATER DETENTION VAULT - 90.1' X 40.8' - SEE DETAIL SHEET C4.3 O
4" PERF PVC SDR 35 FOOTING DRAIN 4O
O6" PVC ROOF DRAIN @ 2% MIN (TYP.)
INSTALL STORM FILTERS AFTER CLEANING ALL CATCH BASINS AND PIPES O
43LF 12" LCPE @ 10.65%
One meter channel
Outlet
Product
Outlet size
(Sch.40)
Invert
Depth
GPM
CFS
B
Bottom outlet - K3-00
8" round
11.81"
1 748
1.67
�FIIIJIIRR
ENOINEERING
vNERVICES, PLLC
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206 890 8291
Cfl
O
O
N
�1
u
SEE
\SEPARATION
NOTES
00
N
o
O
I o
O
FEX.CB #77
O
P o
IW 0
N
0 �
Q
co,
� C6 J
Z)
w
o � U
J
z Qf
Q
a -
T
O
O
O
C'0
N
I..L
r �---.---.--- � R-429009 w
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
SURFACE WATER UTILITY t �
J Farah 09/03/2024 '
DEVELOPMENT ENGINEERING Z
NJanders 09/16/2024 0
GRANT PLACE TOWNHOMES
1600 GRANT AVE S RENTON, WA 98055
PARCEL 2023059052
DRAINAGE CONTROL PLAN
LLI
U
Q
DATE:
11/21/23
J
FlELDBOOK:
PAGE
Z
DRAWING NO:
20069
cr
SHEET: OF,
C4.0 28
-/
Lij
G
O
z
0
LU
U
J
n
I-
z
Q
rr
T
U
zS
m
8
w
Q
U_
370
365
360
355
350
345
340
335
330
325
320
315
310
305
300
295
290
285
280
275
270
EX
O.W.
�2' ROW DEDICATION
W
w
Z
I
Z
j
5' SW
Q
I
Z
CD
I
P STA:0+40.64
I EL: 297.39
K: 3.83
20' VC
m
M
of
U
o
x
+ +
0
LL
LU
H co
U
.. " CV
7.12°/
F�
1 01
48LF 12"pL
CPE @ 3.02%
-
J
EX SDMH-1
RIM EL 294.51
12" IE 286.71 (E)
EX.CB #14
12" IE 287.21 (SE)
RIM EL 297.71
- 12" IE 286.61 (W)
12" IE 288.17 (E)
12" IE 290.01 (N)
12" IE 288.37 (SE)
12" IE 290.16 (NE)
12" IE 288.16 (W)
0+00
0+50
I
PVI STA: 8+70.45
-
PVI EL: 317.05
K: 4.63
37
o6
00
+
N
00
CV
Q M
O
0
M
U M
W W
L6
W
ti
1
0+0
F-�
I
Ir
C
I
-
J
-
=
w
U
w�
EX.CB #8
RIM EL 303.51
12" IE 300.63 (E)
12" IE 300.63 (S)
EX.SFMH#1
RIM EL 300.76
12" IE 290.82 (S)
12" IE 288.52 (W)
-16LF 12" LCPE
i
24LF 12" LCPE @ 50.38%
TO VAULT
1 +00
8+50 9+00 9+50 10+00
GRANT CIRCLE SE (PRIVATE ALLEY)
V: 1"=10' H: 1"=30'
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT'
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.
-GRANT PLACE TOWNHOMES -
BLDG 2
PVI STA: 3+92.96
I 1
I
I
I
PVI EL: 331.72
PVI STA: 4+61.81
PVI STA: 2+87.00
K: 1.95
IL
PVI EL: 435.00
PVI EL: 324.45
20' VC
z I
I K. 1.•
5
K:1.85
o
J
20 ��
20' VC
�
I N
I
I
I
O
I O�
I
+
_�
I`
CSC
Q
N
O
N
04
�+
'
(V
Lf7 (V
U
CO
c
co
Q
��
CV
Imo"
Q
Ln
BLDG 1
U
rn
cliM C0'IT
M
'
w
>
I>
1
>
J
PVI STA: 3+66.96
1
m
J
LUI
LU
J
LU
•
LU w
LU
�
PVI EL: 327.82
PVI STA: 2+60.95
K: 1.85
L:
PVI 320.54
20' VC
1
F
- 1
K: 1.88-
1
"
�
0'VC
I
I
I
I F-
I I I
I I
I I
PVI STA: 1+67.58
co
Oi
I O'
co
II-
PVI EL: 316.44
o
1
F
co
K:1.89
N
o N
o
I �-
��
-
I
m�
co
W
I��
@T.12°I°
00
I
I w
i I
1 14.21% I I
I
ti
F_
1
,.00°/
'
00
F
1 1 I
I 1
I IIF01
a
1 ,- 'CPE
qCl l4°l0
1 1
I
I
I,
'1osLF 12
EX.CB #12
MI I{
-
EX.CB #9
RIM EL 315.69
12" IE 312.18 (E)
12" IE 312.18 (W)
EX.SSMH #8
STA 1 +50.07
8" IE IN 306.30 (E)
8" IE OUT 306.2 (S)
1 +50
10+50
Know what's below.
Call before you dig.
2+00
/,Y i
ozmo
IEX.CB #10
RIM EL 319.95
12" IE 315.99 (E)
12" IE 315.99 (W)
2+50
365
360
355
350
345
340
335
50 330,
t5 325
t0 320
35 315
30 310
?5
305
?0
300
15
295
10 290
)5
285
)0
280
295
290
1 1 +00
8/23/2024
EX.CB #11
RIM EL 327.12
12" IE 323.97 (E)
12" IE 323.97 (W)
-GRANT CIRCLE SE (PRIVATE ALLEY)
V: 1"=10' H: V=30'
3+00 3+50 4+00
RIM EL 335.01
12" IE 332.19 (W)
12" IE 332.19 (E)
cM
m W
15�0°I0 1IX
i
i
i
EX.SSMH #9
STA 4434.14
8" IE 0 JT 326.75 (W)
WATER 10" D.I.
PVI STA: 5+50.34
PVI EL: 348.28
K: 3.33
RIM EB #45.08 I
EX.SSMH #6
STA 5+51.20
12" IE 341.60 (E)
RIM EL 345.05
12" IE 341.59 (NW)
EX.CB #13
8" IE IN 335.16 (
)
RIM EL 340.48
8" IE OUT 335.1
(S)
12" IE 336.82 (SE)
12" IE 336.82 (W)
EX. SSRIH
#5
RIM EL
1.84
-43LF 12" LCPE @ 10.65%
8" IE IN
32.81 (N)
00
H I ei
U.) M
W W
I
I
BLDG 6
I I 1
I PVI STA: 7+17.50 1
r
PVI STA: 6+48.87-
PVI EL: 330.70
PVI EL: 333.50
K: 1.83
K: 1.83 1
1 rI go PVI STA: �+46.27
20' VC
2P' VC
PVI EL: 3.26.38
o o
K: 2. 3
370
365
360
O�
0
iC�T
355
o
350
O
PVI STA: 8+33.11
N
PVI EL: 321.49
K: 3.19
345
U
00
co
I
00
0
o+ + '
�� 'moo 20' V
20' VC
+
CD
+
co
H Yr O� N
U I+
M
C*
340
I
----
co
�0��
U
'w
M I
II
U
M I
I
�- J
I w -1`i`�IwQCR I a00 �
1 o
I �o 0
WWI
�°��,
CO
335
I
�w
�,M
I
v`�'
W
+W
I mIww
ii
00
_
I
330_oo
I II
w
I I
I-mIW4.08%
U)
w
\ I
I II
1 1
I I w
w ��
_
I I
z
325
EX.SSMH #4
vo7h
co
STA 6+27.31
_
00
RIM EL 336.56
320
8" IE IN 328.75
NE)
11.90
O
8" IE OUT 328.
5 (W)
w
CB #4
w`
RIM EL 340.60
315
C)
12" IE 337.92 (NW)
C'7
N
-55LF 12" RCP @ 0.60%
310
Q
Z)
305
J
4+50 5+00 5+50 6+00 6+50
7+00 7+50 8+00 8+50
BLDG 4 & 5
J
I '�
a
r,-
I
BLDG
3,6
CAI
r'
1
O I
@� Al
BLDG2,7
I
r
i
1 p4LF 12' LCPE
EX
-
EX.CB #7
R.O.W.
---
RIM EL354.82
55LF 12" RCP
@ 0.60% w
12" IE 349.02
(W)
BLDG 1, 8
�2' ROW
DEDICATION
I
1
RCP
_
4 99%
@
W
_ 17'
WATER
10" D.I.
'I
I
p1°�o
EX.CB #18
EX.CB #6
I
RCP @ 9
RIM EL 341.06
345.08
' 103vF 12
12" IE 337.59 (W)
12" IE 341.60 (E)
EX.SSMH #7
TA 5+73.32
11
1
1
1 I /
RIM EL 335.01
RIMEX.EL 35.
2" IE 337.59 (SE)
12" IE 341.59 (NW)
U)
II
i
' '
12" IE 332.34 (W)
RIM EL 354.13"
W)
IE OUT 343.49
LU
12" IE 332.34 (E)
EX.SSMH #6
p 65 °
CB #4
RIM EL
STA 4+76.92
4 . E
IRIM
EX.CB #16
/
_ _ _
1p3�F 12�
12" IE 3
7.92 (NW)
8" IE IN 335.16
E)
Q
I
RIM EL 325.70
8" IE OUT 335.1
(S)
Z U
I
12" IE 323.03
< Lu
I
12" IE 323.03 (E)
C� o
I
/
w
Q
U_
I
/
1
#15
EX. SEWER-,--,EX.CB
- -
RIM EL 317.65
12" IE 312.67 (SW)
\12" IE 312.67 (E)
_30LF 12" RCP @ 79.36%
STATIONS:
LOT CENTER LINE PROFILE
-VAULTINLET
STA: 0+85.08
V:1"=10' H: 1"=30'
STATIONS ARE AS PER LOT CENTER
LINE ALIGNMENT.
ELEV: 289.21
0+50
4 PER CITY COMMENTS
3 PER CITY COMMENTS
2 PER CITY COMMENTS
1 PER CITY COMMENTS
K0
1 +00
1 +50
2+00
SURVEYED:
DAF
08/26/24
DESIGNED: DAF
DAF
07/29/24
DAF
05/21 /24
D'�W"`
TJW, FEM
DAF
04/04/24
CHECKED:
DAF
BY
DATE
1
APPR
I APPROVED:
2+50 3+00 3+50 4+00
URR
��ERVICES, PLLC
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
SCALE:VEffn_
1 "=30' HORIZONTAL- N DV 1983/1991 Adoftk
CITY OF
RENTON
ONE INCH DATU M
AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
365
1,6110
355 N
T
C)
350 O
O
345 N
0-
340
335 1
330
325
320
315
310
305
300
295
290
285
280
4+50 5+00 5+50 6+00 6+15 U)
R-42901 0 LU
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
DEVELOPMENT ENGINEERING z
SURFACE WATER UTILITY U
JFarah 09/03/2024 NJanders 09/16/2024 0
LLJ
U
Q
DAM _j
GRANT PLACE TOWNHOMES 11/21/23
1600 GRANT AVE S RENTON, WA 98055 PAGE. OK:
DE:
PARCEL 2023059052 DRAWING NO: z
20069 oC
ROAD AND STORM PROFILES SHEET: OF: %•
C4.1 28 �/
Cl)
CLU
G
O
z
O
W
U
Q
n
z
Q
0
N
U
V
5'x10' GRATED LOCKING
REMOVABLE
ACCESS PANEL (MARKED DRAIN)
RIM=302.91
- a
a'
8
STEEL PROTECTION CAGE
a14
0.010'Wxl.9'HNOTCH
. a
PIPE SUPPORT: a.
3" X .090" ALUMINUM
W/ %" STAINLESS BOLTS
a
a
12" OUTLET PIPE
EXIST
FRAME & LADDER OR
STEPS OFFSET. SEE
NOTE 8.
100-YEAR WATER SURFACE
iT DESIGN EL.=299.02
1-1-18" RISER
0
LU
0
Q
— 8" SHEAR 0
(—
GATE w
o J
00
0
IE=295.57 AB
AS PER SURVEY
DATED 03/05/24
COUPLING
SOLID FLANGE OR CAP
ELEV=293.57
m WATER QUALITY
EL.=290.87 AB
°a a a a
a
PROPOSED FLOW CONTROL STRUCTURE
5'x10' GRATED LOCKING
REMOVABLE
ACCESS PANEL (MARKED DRAIN)
RIM=302.91
a
a'
SOLID FLANGE OR CAP °�
ELEV=299.52
aa.
ELBOW WITH ORIFICE ELEV=294.87
DRILL A 0.98" HOLE IN PLATE WELDED TO
FLANGE OR DRILLED TO CAP a
a.
a
FRAME & LADDER OR
STEPS OFFSET. SEE
NOTE 8,
100-YEAR WATER SURFACE
II DESIGN EL.=299.02
PIPE SUPPORTS (2 MIN):
3" X .090" ALUMINUM ° 18" RISER
W/ %" STAINLESS BOLTS
a'
0
8" SHEAR c*"'
12" OUTLET PIPE GATE o
EXIST
01
WATER QUALITY
EL.=290.87 AB
IE=290.87 AB a Q
AS PER SURVEY a: i
DATED 03/05/24
COUPLING �. w
a
ti
ti
d V
RESTRICTOR PLATE WITH ORIFICE
ELEV=289.87 m BQWS
DRILL A 0.90" HOLE IN PLATE WELDED TO DESIGN EL.=286.10
FLANGE OR DRILLED TO CAP
°a a a a
a
a 4-
PROPOSED WATER QUALITY CONTROL STRUCTURE
NTS
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
Know what's below.
Call before you dig.
0
NE 1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
STORMFILTER MANHOLE
SEE DIET. ON SHEET C4.1
SD
°a \
a �\
a \ a
d \ �
d .
�i EXIST CONTROL STRUCTUR
\ IN VAULT - SEE DETAIL SHEET C4.3
\ GRATE WITH HATCH
\ d
° a
LT AC
1
a ,
PROPOSED
PAII INr a\
PROPOSED
KEYSTONE °
WALL
°
4" PERF PVC SDR 35
FOOTING DRAIN
A \.
4 PER CITY COMMENTS
3 PER CITY COMMENTS
2 PER CITY COMMENTS
1 PER CITY COMMENTS
8/23/2024 NU. REVISION
SED
SIDEWALK
'-- PROPOSED
KEYSTONE
WALL
WATER QUALITY
CONTROLSTRUCTURE 1+00 _ — — — -4- — —
IN VAULT SEE DETAIL
SHEET C4.3 PROPOSED
V L 1. ACUESS 7 PARKING
VAULT ACCESS / ° °° d - -----------
d / °
°
a 5'x10' GRATE � d
-SEE C4.3 - -- � --- -
d
°
VLT
d ° d
.12 \C� EP• . \° ° SSMH—g °
d
f PROPOSED AIM— 313.68 d
GRASSCRETE 'TR. C H . = 306.2
°
\12 PROPOSED., \ \ EXISTING VAULT °
KEYSTONE
d
WALL \/ \ \
\/ \\ EXIST WALL
V
� a
EXI§T�PERF PV DRAIN PROPOSED �` 4.4 C
��\ \ SIDEWALK R I M =
12 c
12 C
0 1 V �� \ 4" PERF PVC SDR 35 " \
\ FOOTING DRAIN N 4 P
vL A c 5
VL A S � D �-0 .9
\ \ \ d
u L ID 0 �/� \ � 5°
�� v / 0 \
\ \ T ACC S 1 5�
XIST PERF PVC DRAIN \ \ d
L`I\D.5 0`8
I a
VLC
°\ ID- b�\\ 9 0�'✓
VAULT ACCESS
4
\ �5'x10' GRATE
SEE C4.3
G J a
° \ 14' 55L°'1 308.09 <4
C d a PROPOSED
PARKING
CA �� PROPOSED °
12 C P E P ACCESS,
S — 88.9F
DRIVEWAY
7 -
-- -- da - - -- - - - -- - -- ----
__
0
\ \ a
V
SURVEYED:
DAF
08/26/24
DESIGNED:DAF
DAF
07/29/24
DAF
05/21 /24
DRAWN:
TJW, FEM
DAF
04/04/24
CHECKED:.-
BY
DATE
I APPR
I APPROVED:
SCALE:
1 "=30' HORIZONTAL NAD ;98 ,,99, CITY OF
RENTON
ONE INCH DATUM
AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
10 5 0 10 20
SCALE: 1 INCH = 10 FEET
NOTE:
CONTROL STRUCTURES SHOP DRAWINGS AS SUBJECT
FOR APPROVAL BY THE ENGINEER OF RECORD PRIOR
TO THE MANUFACTURING AND INSTALLATION.
NOTE:
STORM FACILITIES HAVE BEEN INSTALLED UNDER AN
EXPIRED PERMIT AND REFLECT AS -BUILT CONDITIONS.
NEW VAULT BUILDING PERMIT BY CITY OF RENTON
WILL BE REQUIRED.
LEGEND
PROPOSED GRASSCRETE SERVICE DRIVEWAY FOR STORM
VAULT MAINTENANCE
PROPOSED ASPHALT PAVEMENT
4° PROPOSED CONCRETE SIDEWALK
d
EX STORM DRAIN
PROPOSED 4" PERF PVC FOOTING DRAIN
M
O
O
O
C'7
N
,
u
N
Q
J
FURR
ENGINEERING
am
QERVICES, PLLC
4715142nd PI.
Edmonds, WA 98026
ph 206.890.8291 W
R-42901 1 LU
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
DEVELOPMENT ENGINEERING z
NJanders 09/16/2024 U0
W
U
Q
DATE:
GRANT PLACE TOWNHOMES 11/21/23 a-
1600 GRANT AVE S RENTON, WA 98055 FIELDBOOK:
PAGE:
PARCEL 2023059052
DRAWING N0:
20069
VAULT PLAN AND DETAILS SHEET: OF:
C4.2 28 V
0
N
0 315
w
Cw 305
G
0
z
300
0
I1J
U 295
Q
n
z 290
Q
rr
285
C'7
U
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
GRASSCRETE ACCESS
RAIL FENCE VAULT ACCESS 3
H=42" EXISTING GRADE GEOFOAM BLOCKS 24"0 SOLID LOCKING LID
KEYSTONE RET. WALL VAULT ACCESS 4 EPS46 OR EQUAL
24"0 SOLID LOCKING LID FINISHED GRADE W/ FRAME (TYP)
T PP P MARKED DRAIN
.........................................................................................................................................................................................................................................................................................................................................................................................................:................................................................................................................................ .................................... ....................................................................... TRI.M..OR..S....E.......IN..G.TO.....RO.W.QE.................................................:...........................................................................................................................................................................................(...................................).............................................
WI FRAME (TYP)
FINISHED GRADE (MARKED DRAIN) GEOFOAM BLOCKS TO MATCH AB RIM=306.99
VAULT AJE
AB RIM=304.18 FINISHED GRADE SLOPE
5'x10' GRATED LOCKING REPROPOSED RIM=306.46
ACCE
AE3.R
FINISHED GRADE �300.7 (AVERAGE)L L
e
..........................................................................
................................................................................................................................. ...._.............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................. ................ .CONTROLST CTURE - - -
_ MAX. DEPTH FROM
FINISHED GRADE TO
34LF 12" TO CB #14 0.67' FREEBOARD
100-YEAR WATER SURFACE e VAULT SHALL BE 20 FEET
IE.=295.57 DESIGN EL.=299.02 AT ACCESS POINTS
............................................................................................................................................................................................................................. .................................................................................................................................................................:.................................................................................................................................................................................................................................................................................................. —
8:18` CIVE'S70'RAGE..............................................................................................................5'x7' OPENING
WATER QUALITY CONTROL AS -BUILD REQUIRED VOLUME 29,359 CF
STRUCTURE W/ SOLID TOP WATER QUALITY e PROVIDED VOLUME 29,960 CF 5'
......................................................................................................................................................................28LF 1.. F 12, TO ...........................................
STORMFILTER MANHOLE
4" PERF. PVC SDR35
FOOTING DRAIN @ S= 0.5%
MIN. (TYP.)
............................................................................................................................................ ......RAVEL AR
............................
FOOTING DRAIN (TYP.)
SHEET DRAIN
(TYP.)
4" C.O.
W/ VALVE BOX
FRAME & COVER
& CONC. PAD
4" MIN.GRASSCRETE PAVERS
2" MIN. CHOKER COURSE
(3/4" CRUSHED STONE)
ON 6" MIN. CRUSHED SURFACE BASE
i\� \
(3/4" TO 1-1/2" CRUSHED STONE)
V MIN NATIVE SOIL BACKFILL
4" PVC VERT. PIPE
GEOFOAM BLOCKS
EPS46 OR EQUAL
4" PERF. PVC
@ S=0.0050
6" MIN. GRAVEL BASE
•a
' %• 4 TOP OF VAULT
EL.=300.73
WATER SURFACE
DESIGN EL.=358.4
GEOFOAM DETAIL SECTION A -A
IE.=290.87 - - - - -
DESIGN EL.=290.87 7f
---------------------------------------------------- --- -------------- -----
........................................................................................................................................................................................................................................ ...................................................................................... . ..... ... .......
SEDIMENT STORAGE 288.98
DESIGN EL.=286.10 e 4.77' DEAD STORAGE REQUIRED VOLUME 8,856 CF
(AVERAGE) PROVIDED VOLUME 17,535 CF
0+50
.............................................................................................................................. -.........................................................................................................................................................................................................................
0.T SEDIMENT STORAGE (VARIES)
90.0,
315
310
4" MIN.GRASSCRETE PAVERS
2" MIN. CHOKER COURSE
(3/4" CRUSHED STONE)
305
ON 6" MIN. CRUSHED SURFACE BASE
(3/4" TO 1-1/2" CRUSHED STONE)
2' MIN.
V MIN NATIVE SOIL BACKFILL
FILTER FABRIC ON TOP AND
300
AROUND SIDES OF GEOFOAM
1' MIN. BLOCKS
I�►I GEOFOAM BLOCKS
I I EPS46 OR EQUAL
FILTER FABRIC
295
GRAVEL
4" PERF. PVC
6" MIN. GRAVEL BASE
t
• �' R ' '' TOP OF VAULT
290
EL.=300.73 (AVERAGE)
WATER SURFACE
DESIGN EL.= 358.4
285
GEOFOAM DETAIL SECTION B-B
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
Know what's below.
Call before you dig.
8/23/2024
280
1 +00
DETENTION VAULT SECTION A -A
VAULT ACCESS 5
EXISTING GRADE
24" 0 SOLID LOCKING LID
EXIST WALL
VAULT ACCESS 4
W/ FRAME (TYP)
GEOFOAM BLOCKS
24"0 SOLID LOCKING LID
MARKED DRAIN
( )
EPS46 OR EQUAL FINISHED GRADE
...................................................................................W/..F.R.AM.E...TYP...............................................................................................................AB
(TYP)
=3 ..................................................................................................................................................................................................................
AB RIM-304.90
......................................................................
(MARKED DRAIN)
TOP OF VAULT PROPOSED RIM=307.16
AB RIM=304.18
EL.=300.73
PROPOSED RIM=306.14
. _
........... .................................. ....................... .................. ............................................. ................... ............ .......................... :........................................................................ ...
4 PERF. PVC
4" PERF. PVC
0.67' FREEBOARD
100-YEAR WATER SURFACE
DESIGN EL.=299.02
4" PERF. PVC SDR35
20.0'
FOOTING DRAIN @ S=
AS -BUILD
0.5% MIN. (TYP.)
WATER QUALITY
DESIGN EL.=290.87
...................................................................................................................................................................................................................................................................................
/
SEDIMENT STORAGE
DESIGN EL.=286.10
6" MIN. GRAVEL AROUND
FOOTING DRAIN (TYP.)
4 PER CITY COMMENTS
3 PER CITY COMMENTS
2 PER CITY COMMENTS
1 PER CITY COMMENTS
NO. REVISION
8.15LIVE STORAGE
........................................... ................................................................................................................................................................................................................................................................
20.0 SHEET DRAIN (TYP.)
...................................................................... i.............................................................................. .
4.77' DEAD STORAGE
(AVERAGE)
o+oo o+50
DETENTION VAULT SECTION B-B
1 "=5'
FURR
ENGINEERING
SERVICES, PLLC
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
SURVEYED: SCALE: VEffnCAL*
°1988
�
DAF 08/26/24 DESIGNED: 1 a_ —30' HORIZONTAL NAD 1983/1991 o CITY OF
DAF 07/29/24 DAF DRAWN: RENTON
DAF 05/21 /24
TJW, FEM ONE INCH •
DAF 1 04/04/24 1 CHECKED: DATU M
DAF AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
BY DATE APPR APPROVED: SCALE ACCORDINGLY
.......................................................................
34LF 12 FROM CB #1
315 315
310 310
305 305
300 300
295 295
290 290
285 285
101W
[Late]
K191.1
•
280
1 +35
FINISHED GRADE
GEOFOAM BLOCKS
EPS46 OR EQUAL VAULT ACCESS 2
5'X10' GRATED LOCKING
.........................a................................................................REMOVABACESPANEL................
ABRIM=308.09 ................................... ................................................................................................................................
MAX. DEPTH FROM
FINISHED GRADE TO
VAULT SHALL BE 20 FEET
AT ACCESS POINTS
ELEV=288.50
DETENTION VAULT SECTION C-C
N
�1
u
H
H
co
Q
Z)
J
N
T
315 C)
C)
C)
i
C'7
310
305
300
295
290
285
'280 280' '280
0+60 0+30
U)
R-429012 LU
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
FNJanders,
MENT ENGINEERING z
09/16/2024 0
W
U
Q
DATE: J
GRANT PLACE TOWNHOMES 11/21/23
1600 GRANT AVE S RENTON, WA 98055 FIELDBOOK:
PAGE
PARCEL 2023059052 DRAWING NO:
20069 oC
VAULT DETAILS SHEEP: OF: C4.3 28 0
0
N
0
W
W
5
O
2
>Z
O
W
U
n
I—
Z
Q
rr
CU
7
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT:
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
FLOC
IF ---
INLET --
e /
TOP SLAB ACCESS
SEE FRAME AND
COVER DETAIL
CONTRACTOR TO GROUT TO
FINISHED GRADE
GRADE
RING/RISERS
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
PLAN VIEW
STANDARD OUTLET RISER
FLOWKIT: 42A
_ OUTLET
SUMP
A
rQJOUTLET
6'-0" [018291 I.D.
MANHOLE STRUCTURE
�(OT-0" [021341) O.D.
J a I
FLOATABLES
STORMFILTER BAFFLE
CARTRIDGE Q
U
w
Q c"
W 04
z 00
INLET PIPE --/ l a I I I I I � I l�
Know what's below.
Call before you dig.
a -
FLOW KIT
0 j z
OUTLET SUMP
U w
HDPE OUTLET RISER
z�
—O
SECTION A -A
= _ °
The Stormwater Management
StormFilter0
THIS PRODUCT MAY BE PROTECTED BY ONE OR MORE OF THE FOLLOWING
U.S. PATENTS: 5,322,629; 5,524,576; 5,707,527; 5,985,157; 6,027,639; 6,649,048;
RELATED FOREIGN PATENTS, OR OTHER PATENTS PENDING.
8/23/2024
STORMFILTER DESIGN NOTES
STORMFILTER TREATMENT CAPACITY IS A FUNCTION OF THE CARTRIDGE SELECTION AND THE NUMBER OF CARTRIDGES. THE STANDARD MANHOLE
STYLE IS SHOWN WITH THE MAXIMUM NUMBER OF CARTRIDGES (7). VOLUME SYSTEM IS ALSO AVAILABLE WITH MAXIMUM 7 CARTRIDGES.
06-0" [1829 mm] MANHOLE STORMFILTER PEAK HYDRAULIC CAPACITY IS 1.5 CFS [42.5 Us]. IF THE SITE CONDITIONS EXCEED 1.5 CFS [42.5 L/s] AN
UPSTREAM BYPASS STRUCTURE IS REQUIRED.
CARTRIDGE SELECTION
CARTRIDGE HEIGHT
27" [686 mm]
18" [458 mm]
LOW DROP
RECOMMENDED HYDRAULIC DROP (H)
3.05' [930 mm]
2.3' [700 mm]
1.8' [550 mm]
SPECIFIC FLOW RATE (gpm/sf) [L/s/m2]
2 [1.30]
1.67* [1.08]
1 [0.65]
2 [1.30]
1.67* [1.08] 1 [0.65]
2 [1.30]
1.67* [1.08]
1 [0.65]
CARTRIDGE FLOW RATE (gpm) [L/s]
22.5 [1.42]
18.79 [1.19]
11.25 [0.71]
15 [0.95]
12.53 [0.79] 7.5 [0.44]
10 [0.63]
8.35 [0.54]
5 [0.32]
* 1.67 gpm/sf [1.08 L/s/m2] SPECIFIC FLOW RATE IS APPROVED WITH PHOSPHOSORBR (PSORB) MEDIA ONLY
FRAME AND COVER
(DIAMETER VARIES)
N.T.S.
SITE SPECIFIC
DATA REQUIREMENTS
STRUCTUREID
SFMH#1
WATER QUALITY FLOW RATE (cfs) [L/s]
0.0266 CFS
PEAK FLOW RATE (cfs) [L/s]
0.1153 CFS
RETURN PERIOD OF PEAK FLOW (yrs)
2
CARTRIDGE HEIGHT (SEE TABLE ABOVE)
18"
NUMBER OF CARTRIDGES REQUIRED
7 PSC
CARTRIDGE FLOW RATE
10.0167 CFS
MEDIA TYPE (PERLITE, ZPG, PSORB)
I ZPG
PIPE DATA:
I.E.
MATERIAL
DIAMETER
INLET PIPE #1
(S) 290.82
LCPE
12"
INLET PIPE #2
OUTLET PIPE
(W) 288.59
LCPE
12"
RIM ELEVATION 300.59
ANTI -FLOTATION BALLAST
WIDTH
HEIGHT
6"
12"
NOTES/SPECIAL REQUIREMENTS:
* PER ENGINEER OF RECORD
GENERAL NOTES
1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE.
2. DIMENSIONS MARKED WITH () ARE REFERENCE DIMENSIONS. ACTUAL DIMENSIONS MAY VARY.
3. FOR SITE SPECIFIC DRAWINGS WITH DETAILED VAULT DIMENSIONS AND WEIGHTS, PLEASE CONTACT YOUR CONTECH ENGINEERED SOLUTIONS
LLC REPRESENTATIVE. www.ContechES.com
4. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS
DRAWING.
5. STRUCTURE SHALL MEET AASHTO HS-20 LOAD RATING, ASSUMING EARTH COVER OF 0' - 5' [1524 mm] AND GROUNDWATER ELEVATION AT, OR
BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS SHALL
MEET AASHTO M306 AND BE CAST WITH THE CONTECH LOGO.
6. FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL
BE 7-INCHES [178 mm]. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS.
7. SPECIFIC FLOW RATE IS EQUAL TO THE FILTER TREATMENT CAPACITY (gpm) [L/s] DIVIDED BY THE FILTER CONTACT SURFACE AREA (sq ft)[mz].
8. STORMFILTER STRUCTURE SHALL BE PRECAST CONCRETE CONFORMING TO ASTM C-478 AND AASHTO LOAD FACTOR DESIGN METHOD.
INSTALLATION NOTES
A. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE
SPECIFIED BY ENGINEER OF RECORD.
B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE.
C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE.
D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S).
E. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. STORMFILTER EQUIPPED WITH A DUAL DIAMETER HDPE
OUTLET STUB AND SAND COLLAR. IF OUTLET PIPE IS LARGER THAN 8 INCHES [200 mm], CONTRACTOR TO REMOVE THE 8 INCH [200 mm] OUTLET
STUB AT MOLDED -IN CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR.
F. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF.
SURVEYED: SCALE:VEffn_
r
4 PER CITY COMMENTS DAF 08/26/24 1 a— —30 HORIZONTAL- N D 1983/1991
DESIGNEDDAF
3 PER CITY COMMENTS DAF 07/29/24
2 PER CITY COMMENTS DAF 05/21/24 DAWN'
TJW, FEM ONE INCH DATU M
1 PER CITY COMMENTS I DAF 1 04/04/24 CHECKED:
AT FULL SCALE
DAF IF NOT ONE INCH
NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY
CITY OF
RENTON
Planning/Building/Public Works Dept.
FURR
:±;�:1111VIM1%
NEERING
PLLC
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
R-429013
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
NJanders 09/16/2024 '
GRANT PLACE TOWNHOMES
1600 GRANT AVE S RENTON, WA 98055
PARCEL 2023059052
STORMFILTER DETAILS
DATE:
11/21/23
FIELDBOOK:
PAGE:
20069
SHEET: OF,
C4.4 28
O
O
O
C'7
N
61
M
Q
J
N
T
C)
O
C)
C'7
rr
n
0
w
5
O
Z
O
W
U
Q
J
0-
Z
Q
0
N
I
O
I�
W
V )
5W
L
O
2
Z
`O
1
W
U
n
Z
�rr
V
L J
U
0
0
ifl
8
w
Q
W
U_
11" 2" 4" 6", 12", OR 24"
ONE #3 BAR HOOP FOR 6" HEIGHT
INCREMENT (SPACED EQUALLY),
SEE NOTE 1
RECTANGULAR ADJUSTMENT SECTION
S�6
�1a0
E
26 5
N
#/3 BAR EACH CORNER
SFF 22,
\OTFT
#3 BAR EACH SIDE �Y
#3 BAR EACH WAY v
PRECAST BASE SECTION
#3 BAR HOOP
#3 BAR EACH
CORNER 18" MIN.
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
PUBLIC WORKS
FI` DEPARTMENT
1 251;4"
29 1 /4"
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR PLAIN
12"
CONCRETE
ALL METAL PIPE
15"
CPSSP"
12"
STD. SPEC. 9105.20
SOLID WALL PVC,
STD. SPEC. 9-05.12(1)
15"
PROFILE WALL PVC,
STD. SPEC. 9.05.12(2)
15"
" CORRUGATED POLYETHYLENE STORM
SEWER PIPE
NOTES:
1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN
IN THE PRECAST BASE SECTION, FIBERS (PLACED IN
ACCORDANCE WITH STANDARD SPECIFICATION
9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF
0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH
THE MINIMUM REQUIRED REBAR SHOWN IN THE
ALTERNATIVE PRECAST BASE SECTION. WIRE MESH
SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN
ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN
THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH
HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER
FOOT MAY BE USED.
2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER
THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS
OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5"
MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE
OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED,
FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-04.3.
3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO
THE LOWEST PIPE INVERT SHALL BE 5 FEET.
4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE
FLANGE DOWN.
5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED
FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF
1 H:24V OR STEEPER.
6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE
PRECAST BASE SECTION.
7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE
INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR
NON -SHRINK APPLICATIONS IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-20.3(2).
8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN
MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE
AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND
FRAMES.
9. MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURER'S DIRECTIONS.
1TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
0. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH.
11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
REMAIN VISIBLE UPON COMPLETION.
UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NTS)
STD. PLAN - 200.00
[PIRRED:
CATCH BASIN TYPE 1 GAZ 9/28/2018 1
PvbbAdmmiso- DATE
BOLT -DOWN HOLE (TYP.) - 5/8",
11 NC, SEE DETAIL AND NOTE 2
TOP
RECESSED ALLEN
HEAD CAP SCREW
5/8" - 11 NC x 2"
GRATE
FRAME
SECTION BOLT -DOWN DETAIL
SEE NOTE 2
24 1 /4"
�\
SECTION A
SEE DETAIL _ ISOMETRIC VIEW
7/8" 4"
1/8" �
3/4" \\
' 11/4" ` NOTES:
1. THIS FRAME IS DESIGNED TO ACCOMMODATE 20" x 24" GRATES OR COVERS,
4 1l2" SEE STANDARD PLANS 204.10, 204.20, AND 204.30.
I\ 1 5/8" I 2. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND
/ COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE
1 5,'8" FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS.
THE FRAME SHALL ACCEPT THE &W-1 1 NC x 2"ALLEN HEAD CAP
3/4" BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OFCREW BY
\ BOLT -DOWN HOLES VARIES BY MANUFACTURER.
�21/2"�
3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL
\ DETAIL / REQUIREMENTS.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 204.00
• PUBLIC WORKS APPROVED:
DEPARTMENT RECTANGULAR FRAME "sp
Martinn P 1astucha 0/19/2022
UR
Nkw d]S1k,Ad i-t
Pubiir Wwks Adminiscrato, DATE
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT:
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
Know what's below.
Call before you dig.
NE 1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N.7 R. 05 E, W.M.
2' 11-1/2"
4-3/4" 2'2" 4-3/4"
rr
4-1/2" ------
1 r
I I
I
2' 7" 1' 1 D" I I
I I
I I
l
4-1/2" ------
GRANT PLACE TOWNHOMES
CONVERSION RISER
ONE #4 BAR HOOP
#4s EACH SIDE OF OPENING
ADJUSTMENT RINGS 6"
CONVERSION RISER 8"
6"
3' 6-1/4"
I I
1 f 1
I I 11
I I I I I I
I I I 1 1 I 5' 5-3i4'
11 I 1 I
I I I
jL 3 J j j l
1 7 1 I I I
I I I
L--------J
5-112"
�2'9-1/2'� 2'5"------
DEPTH: 3.52' TO IE OUT
UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NTS)
STD. PLAN - 200.40
� PUBLIC WORKS PPR
MD
CONVERSION RISER URDEPARTMENT GAZ 9/28/2018 1
Public Works Admmistmto, DATE
24" '
BOLT -DOWN SLOT, 3/4•
SEE DETAIL AND
2 1/2" DIA. HOLE NOTE 1 1 1/4"
20" A U 518"
o T
O�O�OG
BOLT -DOWN SLOT DETAIL
OQ�d �Q�Q SEE NOTE 1
�3"1 TOP ern
ISOMETRIC
4 3/4" 1 1/2"
1 5/8i
R39% SEE NOTE 2
SECTION A
SECTION B
R26", SEE NOTE 2
5„
NOTES:
3 1/2
r 3/4,,
1 5/81•
1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES,
GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED.
PROVIDE TWO HOLES IN THE FRAME THAT ARE
VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS.
THE FRAME SHALL ACCEPT THE 518"-11 NC x 2" ALLEN
4"
HEAD CAP SCREW BY BEING TAPPED, OR OTHER
3/4" DIA. HOLE
APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES
VARIES BY MANUFACTURER.
1/2" DIA. HANDLE
1 1/2"
2. ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN
LIEU OF THE RIB DESIGN.
SECTION C
3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR
ADDITIONAL REQUIREMENTS.
4. FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD
PLAN 204.00.
UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS)
AOMSTD. PLAN - 204.10
� PUBLIC WORKS
RRECTANGULAR SOLID METAL COVER D 9/28/2018 1
�DEPARTMENT GAZ
PvbrcwAammisnamr DATE
8/23/2024
4 PER CITY COMMENTS
3 PER CITY COMMENTS
2 PER CITY COMMENTS
1 PER CITY COMMENTS
NO. REVISION
CATCH BASIN FRAME AND VANED
GRATE PER STD. PLAN 204.00
RECTANGULAR OR CIRCULAR ADJUSTMENT
SECTION (TWO SECTIONS MAX.)
MORTAR, (TYP.), SEE NOTE 5
4" MIN.
28" MAX. 16" MAX. FLAT SLAB TOP
48", 54", 60", 72", 84'
96", 120" OR 144" SEE NOTE 6, TYP.
16 MAX. FOR
MAINTENANCE STEPS OR
LADDER
12" (TYP.)
T 1"MIN.
12" MAX.
RING 24" 2.5" MAX. REINFORCING STEEL, (TYP.)
MIN.
12• GRAVEL BACKFILL FOR PIPE ZONE
12" BEDDING PER WSDOT STD.
SPECIFICATION SECTION 9-03.12(3)
6 6"
SEPARATE BASE INTEGRAL BASE
PRECAST PRECAST WITH RISER
NOTES:
1. NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS.
2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE
SLOPED TO FACILITATE CLEANING.
3. THE RECTANGULAR FRAME AND GRATE MUST BE
INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE
CAST INTO THE ADJUSTMENT SECTION.
4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2"
MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP
BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE
PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH
JOINT MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9.04.3.
5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET
IN MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9.04.3.
6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE
CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE
ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO
AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF
THE SAME MATERIAL AS THE CONNECTING PIPE.
7. MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURER'S DIRECTIONS.
8. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH.
9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
REMAIN VISIBLE UPON COMPLETION.
PUBLIC WORKS
DEPARTMENT
ISOMETRIC
24"
7 OR 8 EQUAL SPACES
1 DIRECTION OF FLOW
T �
1 5/8" MAX. J
SECTION A
CATCH BASIN DIMENSIONS
CATCH BASIN
DIAMETER
MIN. WALL
THICKNESS
MIN. BASE
THICKNESS
MAXIMUM
KNOCKOUT SIZE
MINIMUM
DISTANCE
BETWEEN
KNOCKOUTS
48"
4"
6"
36"
8"
54"
4.5"
8"
42"
8"
60"
5"
8.1
48"
8"
72"
6"
8"
60"
1 12"
84"
8"
12"
1 72'
1 12"
96"
8"
12"
1 84"
1 12"
120"
10"
12"
96"
12"
144"
12"
12"
108"
12"
PIPE ALLOWANCES
CATCH BASIN
PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER
DIAMETER
CONCRETE
ALL METAL
CPSSP'
SOLID WALL
PVC
PROFILE WALL
PVC,
48"
24"
30"
24"
30"
30"
54"
30"
36"
30"
36"
36"
60"
36"
42"
36"
42"
42"
72"
42"
54"
42"
48"
48"
84"
54"
60"
54"
48"
48"
96"
60"
72"
60"
48"
48"
120"
66"
84"
60"
48"
48"
144"
78"
96"
60"
48"
48"
'CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20)
2 STD. SPEC. 9-05.12(1)
a STD. SPEC. 9-05.12(2)
CATCH BASIN TYPE 2
UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NT
STD. PLAN - 201.00
6 PR-69PE:
GAZ 9/28/2018 1
vvmra works Aamm+snaror DATE
I
OLT-DOWN SLOT, 1 1/2"
EE DETAIL AND
OTE 1
3/4"
1 1.14"
I �
5/8"
I TI
BOLT -DOWN SLOT DETAIL
SEE NOTE 1
LETTERING
V.
3"
5"
5"
20"
5"
SECTION B
NOTES:
1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND
COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN
THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR
COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN
HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED
MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY
MANUFACTURER.
2. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL
REQUIREMENTS.
3. FOR FRAME DETAILS, SEE STANDARD PLAN 204.00.
UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS)
STD. PLAN - 204.20
PUBLIC WORKS
R�
®�
U 1� DEPARTMENT
RECTANGULAR VANED GRATE
JP1'11-D
GAZ 9/28/2018
G
PPbli< ks Administrator DATE
SURVEYED:
DAF
08/26/24
DESIGNED: DAF
DAF
07/29/24
05/21 /24
DRAWN:DAF TJW, FEM
DAF
04/04/24
CHECKED:
DAF
BY
DATE
APPR
APPROVED:
SCALE:
1 "=30'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
CITY OF
RENTON
Planning/Building/Public Works Dept.
SEE NOTE 4
CLEAN SURFACE AND BOTTOM AREA.
PROVIDE UNIFORM CONTACT. THE SURFACE
AREA OF THE BASE SECTION MUST BE
MORTARED TO THE BOTTOM AREA OF THE
ADJUSTMENT SECTION ADJUSTMENT SECTION
I
I
I
I
I
I
I
I
NOTES:
1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER,
DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO
MORTAR IN PLACE IN ACCORDANCE WITH WSDOT/APWA STANDARD SPECIFICATION 7-05.3.
2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED.
3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT.
4. ONLY BY APPROVAL OF THE CITY, THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR Y2 BOND.
5. BASE SECTION SHALL BE SEALED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH MORTAR.
6. MORTAR SHALL MEET THE REQUIREMENTS OF WSDOT/APWA STANDARD SPECIFICATION 9-04.3.
7. PICK / LIFTING HOLES ARE TO BE GROUTED WATER TIGHT, USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-20.3(2).
8. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS.
9. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF
SUFFICIENT LENGTH.
10. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION.
UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NTS)
AOISTD. PLAN - 202.00
�• PUBLIC WORKS PRO
Rt
DEPARTMENT CATCH BASIN INSTALLATION (GAZ 9/28/2018 1
G DATE
Public WPrks Administrator
co
C)
O
N
,
LJ
M
N
Q
J
co
T
C)
O
O
co
rum
ENOINEERING
SERVICES, P=
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291 W
R-429014
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
DEVELOPMENT ENGINEERING Z
NJanders 09/16/2024 0
I-
W
U
Q
DATE: J
GRANT PLACE TOWNHOMES 11/21/23
1600 GRANT AVE S RENTON, WA 98055 FIELDBOOK:
PARCEL 2023059052 PAGE:
DRAWING NO: Z
20069 cr
DETAILS SHEET: OF:
C4.5 281 0
0
N
I
I�
W
I-
V )
5W
L
O
2
z
`O
1
W
U
n
1
z
��
V
0
0
m
8
Lij
a
w
L,
:TIERING
)LT HOLES - 3 PLACES
)UALLY SPACED 120' APART ON
11116 DIA. B.C.
SKID GROOVE PATTERN
DIA. PICKHOLE
PLAN VItW
25" DIA.
314"
2 1/2"
8 3/4"
(TYP.)
COVER SECTION VIEW
COVER BOTTOM VIEW
(3) BLT SOC. (ALLEN HEAD)
518%11 x 1.5 SS RUBBER
WASHER
EON BOLTING DETAIL
1 /8"
R1/8"
26 1/2" DIA.
251/4"DIA. GASKET GROOVE DETAIL
1/4" DIA. NEOPRENE GASKET
1 1/16"
-1/4'- � m 1/2'
ri
6„
3/76"
5/8„ 23 318" DIA. CL OPEN
27 5/16" DIA.
SKID GROOVE PATTERN DETAIL
34 1/8" DIA.
FRAME SECTION VIEW
NOTES:
1. ALL COVERS SHALL BE LOCKING LID PER EJ No. 3717C1
OR APPROVED EQUAL,
2. THIS COVER SHALL ONLY BE USED FOR STRUCTURES
WITHIN PRIVATE DEVELOPMENTS OUTSIDE OF PUBLIC
RIGHT-OF-WAY.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE INTS)
STD. PLAN - 204.40
PAdalitik ,� PUBLIC WORKS STORM ROUND FRAME AND COVER C b"g?d by.
PII DEPARTMENT (PRIVATE) I Aartin Pastuch&✓13/2020
O06Nd4P©98B449D_ DATf
Public Works Atlminiz .a
T MIN. CLEARANCE TO
ANY PORTION OF FLOW RESTRICTOR
TEE INCLUDING ELBOWS
REMOVABLE WATERTIGHT
I
COUPLING OR FLANGE
2" MIN. A
I
ELBOW RESTRICTOR,
SEE DETAIL AND NOTE 10
6" MIN.
MAX.
2' MIN,
6'
PLATE WELDED TO ELBOW WITH
ORIFICE AS SPECIFIED, SEE NOTE 3
ELBOW RESTRICTOR DETAIL
ELEVATION PER PLANS
12" MIN. UNDER
PAVEMENT
16" MAX
ADDITIONAL LADDER RUNGS (IN SETS) TO
ALLOW ACCESS TO TANKS OR VAULTS
WHEN CATCH IS FILLED WITH WATER
II T i/
/ 71
ANGLE AS /
NECESSARY, j
SEE NOTE 7 i
FRAME & SOLID COVER MARKED "DRAIN" WITH
LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50
VERTICAL BAR GRATE FOR
SECONDARY INLET
6" MIN.
WATER
ELBOW RESTRICTOR,URFACE
TDESIGN
SEE DETAIL AND NOTE 10
HANDHOLDS, STEPS, OR LADDER
PIPE SUPPORTS, SEE NOTE 612" (TYP.)
1.5 x D
SEE NOTE 9 (TYP.)
MIN.2' MIN.
T
ISOMETRIC
1
OUTLET PIPE,S
INLET PIPE
NOTES 1 & 5 2'
o MIN.
SHEAR GATE WITH CONTROL ROD FOR
INVERT AND
CLEANOUT/DRAIN (ROD BENT AS REQUIRED
ELEVATION PER PLANS
FOR VERTICAL ALIGNMENT WITH COVER)
12" SECTION OF PIPE ATTACHED BY
PER STD. PLAN 237.30
GASKETED BAND TO ALLOW REMOVAL 2'
MIN.
12"
WELDED RESTRICTOR PLATE WITH
ORIFICE DIA AS SPECIFIED, SEE NOTE 10
NOTES: SECTION A
1.
USE A MINIMUM OF A 54" DIAMETER TYPE 2 CATCH BASIN.
2.
OUTLET CAPACITY: 100-YEAR DEVELOPED PEAK FLOW.
3.
METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST
BE GALVANIZED WITH TREATMENTS 1, 2, OR 5.
4.
FRAME AND LADDER OR STEPS OFFSET SO:
A. CLEANOUT GATE IS VISIBLE FROM TOP.
B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE.
C. FRAME IS CLEAR OF CURB.
5.
IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4".
6.
PROVIDE AT LEAST ONE 3" X .090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM T-0" VERTICAL SPACING).
7.
LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN.
8.
LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS
WHEN CATCH BASIN IS FILLED WITH WATER.
9.
WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING
TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE.
10.
IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE INTS)
STD. PLAN - 237.00
,� PUBLIC WORKS
�I� DEPARTMENT
FLOW CONTROL STRUCTURE -
RESTRICTOR
`DMSWedby:
$/13/20
�l
V4311471�'-'�
1tuuayyrtiin""""Pastucha
fAftp %,449D... DATE
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT:
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
Know what's below.
Call before you dig.
LOT LINE, TYP.
6" DIA MIN. ROOF DRAIN 5' MIN.
STUB WITH CLEANOUT (TYP.) (TYP.)
HOUSE (TYP.)
r T MIN.
NE 1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N.7 R. 05 E, W.M.
GRANT PLACE TOWNHOMES
- PRIVATE TYPE I
CATCH BASIN
I
- PRIVATE ROOF DRAIN
COLLECTOR PIPE;
6" DIA MIN., SL 0.5% MIN. OPE,
2 FT MIN. COVER
PRIVATE JOINT U SD
®�� SD
UTILITY EASEMENT CURB, SIDEWALK
CITY STORM SYSTEM
5' MIN. WIDTH
DRAIN (SD)D)
R.O.W. LINE
PRIVATE STORM DRAIN (SD) SYSTEM,
8" MIN. DIA. PIPE, SEE NOTE 1
ROOF DRAIN TO CONNECT INTO CITY
CATCH BASIN (CB), MIN. SIZE TYPE I
CLEANOUT, TYP AT EVERY 90',
OR 2ND 45' BEND, AND AT 109 MAX.
SPACING ON STRAIGHT SECTIONS -
NOTES:
1. SEE STD. PLANS 220.OD AND 220.10 FOR PIPE MATERIALS AND MINIMUM COVER REQUIREMENTS.
2. THE ROOF AND FOOTING DRAIN SYSTEMS ARE PRIVATELY MAINTAINED.
3. FLOW PATTERN SHOULD BE TO THE NEAREST CB IF GRADE ALLOWS, OR TO THE NEXT DOWNSTREAM CB.
4. ROOF DRAIN COLLECTORS MUST BE ANALYZED FOR CAPACITY, SIZED FOR 25-YEAR PEAK FLOW.
5. PVC PIPE MUST BE SDR 35 OR THICKER AND MEET THE REQUIREMENTS OF ASTM D3034.
6. PVC PIPE USED IN PRIVATELY MAINTAINED DRAINAGE SYSTEMS MUST BE WHITE IN COLOR.
7. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.
8. AREA DRAIN WITHIN CRAWL SPACE IS ALLOWED TO CONNECT INTO THE STORM DRAINAGE SYSTEM WITH
THE FOLLOWING CONDITIONS:
A. THE CONNECTION IS TO BE TIGHT LINED A MINIMUM OF 10' OUTSIDE OF THE FOUNDATION, AND IN NO
CASE CONNECTED UPSTREAM OF THE FOOTING DRAIN SYSTEM FOR THE HOUSE.
B. THE AREA DRAIN MUST BE ROUTED THROUGH A SUMP PUMP SYSTEM PRIOR TO CONNECTION TO THE
PUBLIC STORM DRAINAGE SYSTEM TO HELP PREVENT BACKUP DURING SURCHARGE CONDITIONS.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
AdatSTD. PLAN - 225.00
• PUBLIC WORKS TYPICAL PRIVATE STORM DRAIN i ' SBed by:
DEPARTMENT 8/13/20
PRCOLLECTION SYSTEM ry� apctipn Pastucha
IJ'��U{,fr� aQWD. DATE
(6) EVENLY SPACED HOLES ON 10 3/8" BOLT
CIRCLE FOR BOLTING TO FLANGE CONNECTION
LEVEL LINE
SEE NOTE 5
FRONT SIDE MAXIMUM OPENING OF GATE
HANDLE WITH LOCK PIN
0
ADJUSTABLE LOCK HOOK WITH LOCK SCREW
LIFT HANDLE SHALL BE ATTACHED PER
MANUFACTURER'S RECOMMENDATIONS
o
1" ROD OR TUBING, VARIABLE LENGTH
LIFT HANDLE
NOTES:
1. SHEAR GATE SHALL BE ALUMINUM ALLOY PER ASTM B-26-ZG-32a OR CAST IRON ASTM A48 CLASS 30B AS REQUIRED,
2. GATE SHALL BE 8 INCH DIA. UNLESS OTHERWISE SPECIFIED.
3. GATE SHALL BE JOINED TO TEE SECTION BY BOLTING (THROUGH FLANGE), WELDING, OR OTHER SECURE MEANS.
4. LIFT ROD: AS SPECIFIED BY MFR. WITH HANDLE EXTENDING TO WITHIN ONE FOOT OF COVER AND ADJUSTABLE HOOK LOCK FASTENED TO FRAME OR UPPER
HANDHOLD.
5. GATE SHALL NOT OPEN BEYOND THE CLEAR OPENING BY LIMITED HINGE MOVEMENT, STOP TAB, OR SOME OTHER DEVICE.
6. NEOPRENE RUBBER GASKET REQUIRED BETWEEN RISER MOUNTING FLANGE AND GATE FLANGE.
7. MATING SURFACES OF LID AND BODY TO BE MACHINED FOR PROPER FIT.
8. FLANGE MOUNTING BOLTS SHALL BE 3/8" DIA. STAINLESS STEEL.
9. ALTERNATE CLEANOUT/SHEAR GATES TO THE DESIGN SHOWN ARE ACCEPTABLE, PROVIDED THEY MEET THE MATERIAL SPECIFICATIONS ABOVE AND HAVE
A SIX BOLT. 10 3/8" BOLT CIRCLE FOR BOLTING TO THE FLANGE CONNECTION.
UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS)
�1` DEPARTMENT GAZ 9/
STD. PLAN - 237.30
PUBLIC WORKS TEE SECTION SHEAR GATE 28/2018 1
v„nrr work:aammnvar", DATE
8/23/2024
4 PER CITY COMMENTS
3 PER CITY COMMENTS
2 PER CITY COMMENTS
1 PER CITY COMMENTS
NO. I REVISION
3/4' FLAT FACE GOTHIC
�9"DIA�
00
4❑ ❑ ❑
❑ STORM ❑
4-
0 0 CI 13
OO
8-1 /8" DIA
10-1/2" DIA
(2) 3/8"-16 SS SOCKET HEAD CAP
15" DIA
(1) OPEN PICKHOLE 1"
SCREW (ALLENHEAD) WIWSHRS
ON A 8" DIA BOLT CIRCLE
PLAN VIEW
FRAME SECTION
CAST IRON FRAME AND
COVER, SEE NOTE 3
I� I�
8" CLASS "B"//\\� /\\j�.�
ASPHALT, SEE NOTE 4
CLEANOUT RISER, SEE NOTE 2
PAVED AREA (TYP.)
EXTEND CLEANOUT RISER
2" ABOVE DESIGN PONDING
ELEVATION OR PER PLAN -
DESIGN PONDING
ELEVATION
4" COMPACTED SAND OR
GRAVEL BACKFILL FOR DRAINS
PER WSDOT 9-03.12(4)
8-13/16" DIA
518„
FERNCO GASKETED
QUIK CAP OR SIMILAR
4'STREAMBED COBBLES
F PER WSDOT 9-03.11(2)
CLEANOUT RISER, -III I I I I I I
SOIL TIGHT 45' BEND SEE NOTE1-
/'� III-III-111 III' II-111-
WYE
SOIL TIGHT j\\ \ 1=1 I S I I ] I IS I I--
COUPLERi--,� 1_
UNDERDRAIN, FOOTING
DRAIN COLLECTOR, OR�7 1-111=
ROOF DRAIN COLLECTOR I';=
PIPE, SEE NOTE 1 .,O -. CLEANOUT RISER LOCATED WITHIN
- BIORETENTION PONDING AREA
4_1_1 \41 Iffifil
TO OVERFLOW
STRUCTURE OR
STORM MAIN
MECHANICAL PLUG OR
CONTINUED CONNECTION
TYPICAL CLEANOUT CONFIGURATION
NOTES:
1. DIAMETER TO BE 6-INCHES MINIMUM PRIVATE, 8-INCHES MINIMUM PUBLIC. UNDERDRAIN PIPE PER STD. PLAN 262.10.
2. CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE.
3. FRAME AND COVER SHALL BE EJ PRODUCTS 3675Z1 PT AND 3675APT OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "STORM' OR
"DRAIN".
4. FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BIORETENTION PONDING AREA, POUR 8" THICK, 2'x2' SQUARE CONCRETE COLLAR
AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI.
GENERAL NOTES:
1. CLEANOUTS FOR UNDERDRAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT
EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERDRAIN PIPE NOT CONNECTED TO AN
OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES.
2. ALL FITTINGS SHALL BE SOIL TIGHT.
3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF BIORETENTION PONDING WHERE POSSIBLE.
4. CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
Aoft STD. PLAN - 226.00
,• PUBLIC WORKS BRO$Unr d by:
,1� DEPARTMENT STORM SYSTEM CLEANOUT artinPastucha 8/13/20
11'"AftomwWO... DATE
SEE NOTE 11 (TYP.)
FLOW `/ 0
II1
SUMPAREA I
III 4'MIN.
I
�
ACCESS MANHOLE WITH 24" BOLT
LOCKING RING AND COVER PER
STD. PLANS 204.40 AND 204.50
OUTLET PIPE
FLOW �/ f
SEE NOTE 11 (TYP.)
1 15'x10' REMOVABLE LOCKING
OPTIONAL I I I PANEL FOR VAULTS GREATER VENTILATION PIPE (TYP).
5'x10' ACCESS VAULT THAN 1,250 SF OF FLOOR AREA SEE NOTE g
MAY BE USED IN
LIEU OF TOP ACCESS I I I I PLAN VIEW
L-L
FRAMES, GRATES, AND ROUND SOLID
COVERS MARKED "DRAIN" WITH LOCKING
BOLTS PER STD. PLANS 204.40 AND 204.50
5'x10' GRATE
ACCESS DOORS OR
16" MAX. REMOVABLE PANEL 2' MIN. COVER,
4° MIN. SEE NOTE 10
WALL FLANGE, TYP
Q DESIGN 6" MIN. FLOW RESTRICTOR
WATER
FLOW o = SURFACE Q
�/�► e o e
0 7' MIN.
SEE NOTE 11 (TYP.) HANDHOLDS, STEPS
1 e OR LADDER o e
12" 1 o I 2' MIN. a FLOW
12„ 1 0
6" SEDIMENT STORAGE kNOT
PACITY OF OUTLET PIPE
LESS THAN DEVELOPED
0 - YR DESIGN FLOW
MIN. I SEE NOTE 11 (TYP.)
4' MIN -------
NOTES: SECTION A
1. THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN
CRITERIA.
2. METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5.
3. PROVIDE WATER STOP AT ALL CAST -IN -PLACE CONSTRUCTION JOINTS. PRECEAST VAULTS SHALL HAVE APPROVED RUBBER GASKET SYSTEM.
4. VAULTS 00' WIDE MUST USE REMOVABLE LIDS.
S. PREFABRICATED VAULT SECTIONS MAY REQUIRE STRUCTURAL MODIFICATIONS TO SUPPORT 5' X 10' OPENING OVER MAIN VAULT. ALTERNATIVELY, ACCESS CAN BE
PROVIDED VIA A SIDE VESTIBULE AS SHOWN.
6. ALL VAULT AREAS MUST BE WITHIN 50, OF AN ACCESS POINT.
7. FOR VAULTS UNDER ROADWAYS, THE REMOVABLE PANEL MUST BE LOCATED OUTSIDE THE TRAVEL LANES. ALTERNATIVELY, MULTIPLE STANDARD LOCKING MANHOLE
COVERS MAY BE PROVIDED. SPACING OF MANHOLE COVERS SHALL BE 12 FEET, MEASURED ON CENTER, TO FACILITATE REMOVAL OF SEDIMENT. LADDERS AND
HAND -HOLDS NEED ONLY BE PROVIDED AT THE OUTLET PIPE AND INLET PIPE.
8. MINIMUM DIAMETER FOR ALL ACCESS OPENINGS (RISERS), EXCEPT THOSE COVERED BY REMOVABLE PANELS, IS 36 INCHES.
9. VAULTS PROVIDING MANHOLE ACCESS AT 12 FOOT SPACING NEED NOT PROVIDE CORNER VENTILATION PIPES. VENTILATION PIPES SHALL BE CAPPED OR OTHERWISE
COVERED, BUT DESIGNED SO THAT MAINTENANCE PERSONNEL CAN REMOVE FOR VENTILATION.
10. FOR RAISED OPENINGS WHERE THE DEPTH FROM THE IRON COVER TO THE TOP OF THE VAULT EXCEEDS 24 INCHES, AN ACCESS STRUCTURE EQUIVALENT TO A TYPE 2
CATCH BASIN OR TYPE 1 MANHOLE SHALL BE USED.
11. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING
TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE.
12. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.
UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS)
STD. PLAN - 236.00
, Dtbk PUBLIC WORKS APPROVED:
`��� DEPARTMENT "al9".dby
TYPICAL DETENTION VAULT 10/19/2022
Martin Pastucha
11,tFcffiesaasn
vuerc work: Aaml"gym"m, DATE
V J
co
O
co
,
16J
N
Q
J
\rwURR
ENOINEERING
vNERVICES, PLLC
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
W
R-429015
LU
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
O
DEVELOPMENT ENGINEERING
z
NJanders 09/16/2024
0
I-
W
U
Q
SURVEYED:
SCALE:
1 "=30'
VERTIAL: AD 1981988
HORIZONTAL: NAD 1983/1991
/1
DATUM
' CITY OF
+
RENTON
Planning/Building/Public Works Dept.
GRANT PLACE TOWNHOMES
1600 GRANT AVE S RENTON WA 98055
'
PARCEL 2023059052
DATE:
11/21/23
J
0-
7
L
cr
DAF
08/26/24
DESIGNEDDAF
DAF
o�/29/24
FIELDBOOK:
PAGE:
DAF
05/21/24
°�°�"' FEM
TJW,
ONE INCH
DRAWING N0:
20069
DAF
04/04/24
CHECKED:
DAF
IFAT FULL
NOT ONECNCH
BY
DATE
APPR
SCALE ACCORDINGLY
DETAILS
�•
�/
APPROVED:
SHEET: OR
C4.6 28
0
N
0
W
Cn
5W
L
0
2
Z
`0
1
W
U
n
1
Z
��
V
0
0
m
s
Lij
Q
W
L,
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N.7 R. 05 E, W.M.
GRANT PLACE TOWNHOMES
GENERAL NOTES:
1, ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) SANITARY SEWER AND STORM DRAIN MAIN LINES SHALL BE
INSPECTED BY MEANS OF REMOTE CCTV. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY OF RENTON INSPECTOR
ASSIGNED TO THE PROJECT PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS, AND/OR PAVEMENT.
2. THE CONTRACTOR SHALL PERFORM ALL CCTV INSPECTIONS IN ACCORDANCE WITH THE NATIONAL ASSOCIATION OF SEWER SERVICE
COMPANIES (NASSCO) PIPELINE ASSESSMENT CERTIFICATION PROGRAM (PACP).
3. ALL CCTV OPERATORS SHALL HAVE CURRENT NASSCO PACP CERTIFICATION.
4. CCTV INSPECTIONS SHALL BE RECORDED IN A GRANITENET COMPATIBLE FORMAT DATABASE USING THE LATEST SOFTWARE VERSION
AND SUBMITTED WITH ELECTRONIC LINKS BETWEEN THE DATA AND THE VIDEO ON AN EXTERNAL HDD, OVD, OR FLASH DRIVE.
5. ALL CCTV INSPECTION REPORTS SHALL BE WITHIN +/- TWO (2) FEET OF THE MEASURED LINEAR FOOTAGE BETWEEN MANHOLES ALONG
THE EXISTING PIPELINE CENTERLINE FROM THE START OF PIPE TO END OF PIPE.
6. ALL OWNER AND PACP REQUIRED HEADER INFORMATION MUST BE FULLY AND ACCURATELY ENTERED ON ALL CCTV REPORTS. WORK NOT
FOLLOWING THESE SPECIFICATIONS WILL BE REJECTED AND THE CONTRACTOR SHALL BE REQUIRED TO RE -CCTV THE WORK.
7. THE DOCUMENTATION OF THE WORK SHALL CONSIST OF PACP CCTV REPORTS, PACP DATABASE, LOGS, ELECTRONIC REPORTS, ETC.
NOTING IMPORTANT FEATURES ENCOUNTERED DURING THE INSPECTION. THE SPEED OF TRAVEL SHALL BE SLOW ENOUGH TO INSPECT
EACH PIPE JOINT, TEE CONNECTION, STRUCTURAL DETERIORATION, INFILTRATION AND INFLOW SOURCES, AND DEPOSITS, BUT SHOULD
NOT, AT ANY TIME, BE FASTER THAN 30 FEET PER MINUTE, EXCEPT AS NOTED OTHERWISE IN THIS DOCUMENT.
8. THE CAMERA MUST BE CENTERED IN THE PIPE TO PROVIDE ACCURATE DISTANCE MEASUREMENTS TO PROVIDE LOCATIONS OF FEATURES
IN THE SEWER AND THESE FOOTAGE MEASUREMENTS SHALL BE DISPLAYED AND DOCUMENTED ON THE VIDEO. ALL PACP OBSERVATIONS
SHALL BE IDENTIFIED BY AUDIO AND ON A PACP LOG. ALL VIDEO MUST BE CONTINUOUSLY METERED FROM MANHOLE TO MANHOLE. ALL
VIDEO RECORDING SHALL BE CONTINUOUS FROM STRUCTURE TO STRUCTURE WITH NO "PAUSING" OF THE VIDEO RECORDING DURING
EACH PIPELINE INSPECTION. THE PIPE SHALL BE CLEANED PRIOR TO THE CCTV INSPECTION TO ENSURE ALL DEFECTS, FEATURE, AND
OBSERVATIONS ARE SEEN AND LOGGED.
9. JUST PRIOR TO BEGINNING THE CCTV INSPECTION, WHILE THE CCTV CAMERA IS IN PLACE AND RECORDING, WATER (CONTAINING DYE)
SHALL BE INTRODUCED INTO THE UPSTREAM MANHOLE OF EACH PIPE SEGMENT UNTIL IT IS OBSERVED AND RECORDED FLOWING PAST
THE CAMERA'S FIELD OF VISION IN ITS ENTIRETY.
10. THE CCTV CAMERA SHALL HAVE A WATER -LEVEL MEASURING DEVICE BALL CYLINDER ETC. ATTACHED THAT HAS 1A" MARKINGS TO
SHOW THE DEPTH OF WATER IN THE PIPE DURING THE CCTV INSPECTION.
11. ALL MANHOLES SHALL BE CHANNELED AND COATED PRIOR TO CCTV INSPECTION.
12. PER CITY OF RENTON SPECIFICATION 7-08.3(2)B, SEWER AND STORM DRAIN PIPELINE SHALL HAVE NO MORE THAN 1/2" OF PONDING TO BE
CONSIDERED ACCEPTABLE.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 266.00
®• PUBLIC WORKS CCTV INSPECTION SPECIFICATIONS [PPRMD 9/28/2018 1
�INDEPARTMENT GAZ
T411101vum-c works nam so-aroDATE
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT:
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
Know what's below.
Call before you dig.
8/23/2024
SURFACE WATER STANDARD PLAN NOTES:
THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY
PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE
APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE
SURFACE WATER STANDARD PLAN NOTES.
18. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT
AND SHALL MEET THE FOLLOWING SPECIFICATIONS:
• 4. 8 INCH ROCK 140 - 70% PASSING;
• 2 - 4 INCH ROCK 130 - 40% PASSING; AND
• LESS THAN 2 INCH ROCK / 10 - 20% PASSING.
19. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE
CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BMPS.
20. THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED "STORM" OR "DRAIN" SHALL BE LOCATED AT THE
PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00.
21, ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED
TO THE CITY PRIOR TO CONSTRUCTION.
22. ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED PUBLIC AND PRIVATE STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV
ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL
PROJECT CURBS, GUTTERS AND/OR PAVEMENT.
23. ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS
AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS
TESTED.
24. FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL
EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN
264.00.
25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY
CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM
SYSTEM PROVIDED DURING CONSTRUCTION.
26, ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF
THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED
RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT
STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY.
27. PROJECTS LOCATED WITHIN THE CITY'S AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT 46 OF THE RENTON SWDM AND AQUIFER
PROTECTION REGULATIONS (RMC 4-3-050).
28. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASIN/MANHOLE LIDS, CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF
STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A
SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NONSLIP OR NON-SKID LID PER ADA REQUIREMENTS.
29, CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT.
30, MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM.
31. CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE
PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO
CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE
PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE
MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE,
THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS (E.G., PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE
WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING
ASTM C1781.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 267.10
PUBLIC WORKS SURFACE WATER STANDARD PLAN - f-§Red by:
MR DEPARTMENT NOTES (2 OF 2) Martin PastuchA11312020
l ®81.3 C9dB4A9D DATE
4
PER CITY COMMENTS
DAF
3
PER CITY COMMENTS
DAF
2
PER CITY COMMENTS
DAF
1
PER CITY COMMENTS
DAF
era
REVISION
M.
SURVEYED:
08/26/24 DESIGNED: DAF
07/29/24
05/21 /24 DRAWN'
TJW, FEM
04/04/24 CHECKED:
DAF
DATE APPR I APPROVED:
EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES:
THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL (ESC) PLAN SET. ALL THE NOTES ON THE
LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT
APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC
ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES.
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY
REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR.
2. THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL
PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY
ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT,
3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION
COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS.
4. THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS
PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF
RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE
BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF
CONSTRUCTION.
5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT.
ADDITIONAL MEASURES SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT
CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL
BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING
WATERS OF THE STATE.
6. WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF -SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE
TRUCKS ONTO THE GROUND OR TO STORM DRAINS OR OPEN DITCHES. ON -SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE
WASHOUT AREAS.
7. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF
SEDIMENT TO SURFACE WATER DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL
SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER
CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION,
MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT.
8. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY.
9. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION
PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE
COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE
APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM
REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM.
10. APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS,
CHANNELS, OR STORMWATER FACILITIES.
11. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL.
12. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST
THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED
ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM.
13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY.
14. ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS.
15. THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT.
INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY.
16. BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM
DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED
TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING
CONDITION.
17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 213 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE
CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM.
18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL
PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE
TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT
FACILITY.
19. AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING STORMWATER FACILITIES OR ON -SITE BMPS (AMENDED SOILS, BIORETENTION, PERMEABLE PAVEMENT,
ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION.
20. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR
SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON.
AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW.
21. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVING THE PROJECT SITE,
ALL ESC EIMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON -SITE BMPS SHALL BE RESTORED TO THEIR FULLY
FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM,
DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH
WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST.
22, ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS
RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF
ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE.
UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS)
STD. PLAN - 268.00
PUBLIC WORKS EROSION AND SEDIMENT CONTROL PPR D:
PRDEPARTMENT GAZ 9/28/2018 I
STANDARD PLAN NOTES
vunrcwor�saam �iseraror DATE
SCALE:
1 "=30'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
0 CITY OF
RENTON
Planning/Building/Public Works Dept.
rum
1cb N1
/ \S1.-.-RV1M.% Pu.c
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291 R-429016
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
NJanders 09/16/2024
GRANT PLACE TOWNHOMES
1600 GRANT AVE S RENTON, WA 98055
PARCEL 2023059052
DETAILS
DATE:
11/21/23
FIELDBOOK:
PAGE:
20069
SHEET: OF:
C4.7 28
O
O
O
C17
N
A,
u
CM
CV
Q
ZD
J
N
T
O
O
O
N
I..L
Cn
w
75
0
17
>Z
0
W
U
Q
J
0-
Z
Q
r�
V
0
N
O
W
5
O
2
z
O
W
U
Q
n
H-
z
Q
rr
CD
O
r\
U
2
30'
STA 3+58.81 (GRANT AVE)
=STA 0+00 (GRANT CIRCLE S.E.)
INSTALL STREET MONUMENT
S
=STA10+41
INST)
RENTON MON.
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N.7 R. 05 E, W.M.
GRANT PLACE TOWNHOMES
\ NV rfV\r\IINU I Ir\L LP1wL JIVIV
T C.2 FOR DETAIL SEE SHEET ON BOTH SIDES OF THE ALLEY
55 AT 50 FEET MAXIMUM SPACING
/ 2� ALTERNATING FROM ONE SIDE
TO THE OTHER (TYP.)
SEE SHEET C3.2 FOR DETAIL
z
C
Z
rn
S 181H SI
RENTON MON.
#787
Know what's below.
Call before you dig.
0
N
L0
�t
I
8/23/2024
SITE INFORMATION:
ADDRESS:
PARCEL NUMBER:
ZONING:
PARCEL AREA:
NInTr-c.
0- 29MMAmItisivale]ND]4F
1600 GRANT AVE S
202305-9052
RM-F
92,051 SF (2.11AC)
ALL ONSITE ROADWAYS SHALL BE MARKED AND SIGNED PER CITY STREET
STANDARDS AS FIRE LANES.
SURVEYED:
4
PER CITY COMMENTS
DAF
08/26/24
DESIGNED:
DAF
3
PER CITY COMMENTS
DAF
07/29/24
2
PER CITY COMMENTS
DAF
05/21/24
DRAWN:
TJW, FEM
1
PER CITY COMMENTS
I DAF
1 04/04/24
CHECKEDD F
NO.
REVISION
BY
DATE
APPR
APPROVED:
SCALE:
1 "=30'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL• NAVD 1988
HORIZONTAL- NAD 1983/1991
DATU M
a
N
30 15 0 30 60
SCALE: 1 INCH = 30 FEET
CITY OF
RENTON
1-q'R
Planning/Building/Public Works Dept.
TRACT B
(INGRESS, EGRESS, UTILITY,
AND OPEN SPACE)
FURR
EN6INEERIN6
SERVICES, PLLC
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
R-429017 T-429002
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
NJanders 09/16/2024 '
GRANT PLACE TOWNHOMES
1600 GRANT AVE S RENTON, WA 98055
PARCEL 2023059052
HORIZONTAL CONTROL, SIGNAGE AND STRIPING PLAN
DATE:
11/21/23
FIELDBOOK:
PAGE:
20069
SHEET: OF:
C7.0 28
O�
O
co
O
O
co
N
I1
6W
H
H
M
Q
Z)
J
Q0
N
T
O
O
O
N
rr
0-
Cn
W
5
O
z
O
W
U
Q
J
z
Q
0
0
LU
G
O
>z
O
LU
U
Q
n
z
Q
W-
z
0
1
f�
05
0
c�
m
8
w
z
J
NE 1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
II I--- ( �C,
34�
CB-11 \ I I \ \ 0
\9 /
\ i- \
l #8 \ \ \ \ \
\ / TBM-B \ I \ \\
#5 I � � � \ 24 #35 #3
#48 \ 5 1
#4 \ #46 I
#4 I EXI TING TREES TO 22 \ �51
l I #4 #47 BE /REMOVED (TYP) / #3
1 I 1 x 7 TREE RETENTIO
1 / AREA /� � � #4
#2 2.� EXISTING TREES TO � /
5 #3X1 # 3 #4 BE REMOVED (TYP) / #31
I/ 13 #32 / �.8 #1
r #4 q� B SOB--�
I / #2 #23
j I
49 17
I #37 I 5 � / I #2 � � �,
.,/# J #36 # 12 #52 / ( I #28 / # +4 '
33
/\ Gy-
(NO R c) \ ) / % E C� TING TRE``E (#2.k, J14 & #1
\ \ \ TO REMAI . rTEqT TIREES W/
VIS1.B'ILI C�ST
RUCTIC N FENCE
\ CB- fDM -4
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
11/16/2015
TREE
TABLE
TREE TAG TYPE SIZE DRIPLINE STATUS
TREE TAG TYPE SIZE DRIPLINE
STATUS
1
ALDER
18"& 16"
75'
30
MAPLE
14"
55'
2
18"&14"
70'
31
MAPLE
12"
16'
DANGEROUS
3
16"&10"
50,
32
ALDER
15"
30'
4
CEDAR
40"&36"
55'
33
CHERRY
15"
50'
5
CHERRY
16%14"
40'
34
ALDER
16"
40'
6
ALDER
1211, 811, 6"
50,
35
RED ALDER
16"
15,
DANGEROUS
7
18", 16" 10"
65'
36
ALDER
18"
14'
SIGNIFICANT
8
DECIDUOUS
10", 3 X 6"
20'
37
18"
45'
9
MAPLE
16", 12" 10", 10", 14"
30'
38
20"
45'
10
MAPLE
8"
6'
DANGEROUS
39
20"
50'
11
LOCUST
2X14", 2X12", 6X10", 3X8", 6"
100,
40
RED ALDER
18"
15'
DANGEROUS
12
ALDER
12"
12'
DANGEROUS
41
22"
35'
13
12"
30'
42
FIR
22"
14
RED ALDER
12"
14'
DANGEROUS
43
ALDER
24"
15
12"
25'
44
ALDER
20"
16'
DANGEROUS
16
12"
30'
45
24"
17
BIGLEAF MAPLE
12"
15'
SIGNIFICANT
46
24"
N/A TREE IS DYING
18
MAPLE
8"
10'
47
FIR
24"
19
MAPLE
10"
6'
48
24"
20
ALDER
13"
35'
49
CEDAR
26"
21
13"
25'
50
ALDER
32"
22'
DANGEROUS
22
14"
40'
51
ASH
36"
23
14"
40'
52
CEDAR
31"
14'
LANDMARK
24
RED ALDER
14"
15'
DANGEROUS
53
CHERRY
36"
25
RED ALDER
14"
12'
DANGEROUS
26
RED ALDER
14"
12'
DANGEROUS
27
RED ALDER
14"
12'
DANGEROUS
28
RED ALDER
14"
12'
DANGEROUS
29
RED ALDER
14"
12'
DANGEROUS
Know what's below.
Call before you dig.
8/23/2024
4
3
2
1
He]
PER CITY COMMENTS
PER CITY COMMENTS
PER CITY COMMENTS
PER CITY COMMENTS
REVISION
SURVEYED:
DAF
08/26/24
DESIGNED:
DAF
DAF
07/29/24
DAF
05/21 /24
DRAWN:
TJW, FEM
DAF
04/04/24
1 CHECKED:
DAF
11
BY
DATE
I APPR
APPROVED:
SCALE:
1 "=30,
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
%C� CITY OF
RENTON
Planning/Building/Public Works Dept.
30 15 0 30 60
SCALE: 1 INCH = 30 FEET
0 DECIDUOUS (TO REMAIN)
CONIFER (TO REMAIN)
�n
DECIDUOUS (REMOVED)
CONIFER (REMOVED)
06 HIGH VISIBILITY FENCE
Zw
INEERING
RVICES, PLLC
4715 142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
6,
H
H
N
Q
J
X
X
X
X
X
TM
R-429018 I�
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
CURRENT PLANNING z
Ming 09/03/2024 IL DEVELOPMENT ENGINEERING
NJanders 09/16/2024
�O
LU
U
Q
DATE:
GRANT PLACE TOWNHOMES 11/21/23
1600 GRANT AVE S RENTON, WA 98055 FIELDBOOK:
PARCEL 2023059052 PAGE:
DRAWING N0:
20069 �
TREE RETENTION PLAN SHEET: OF:
C8.0 28 0
O
N
O
0
W
W
75
O
>z
O
W
U
Q
n
z
Q
rr
0
2
0.
0
m
s
w
M
a
z
J
!1
c� EXISTING DOUBLE SWING GATE TO
9ti� BE REUSED OR REPLACED AT THE
9 DIRECTION OF C.O.R. FIRE MARSHAL
LF
SEE DETAIL FOR `S
GATE CONTROL* `
CONNECT GATE ELECTRICAL
CONTROL TO EXISTING POWER
*LOCATION OF DETECTORS AND PEDESTALS
FOR GATE OPERATION TO BE DETERMINED
BY C.O.R. FIRE MARSHAL
EXISTING NORTH GATE
(NTS)
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
E
0
T
22
id
ro
FREE EXIT LOOP
\
Q
3
3
IL
�
\
\
U
\
-
N
\ \ I 120VAC POWER
~
X
REVERSING LOOP
\ I�TO CONTROLLER
ro �*
\
\ I
m
Y 3:
o
Co
rn
\ \ I
a
C Ir
r-
i
MOTOR CONTROL
\
CO
i
PHONE LINE TO
TO GATE OPERATORS
\ \
I
0
0
0
=
a.
TELEPHONE ENTRY
�.—"---,
��GZ
\
\ \
\
_j
PEDESTAL
II \��
'i'�,,
\
3
I
, s9JJ...
I I — .
\
_�5
Co
I
it
\ \ /
o
Co
_j o
U
a
\\
GATE CONTROLLER
LU
u)-
GATE
(location TBD)
C
°, u
CO
\
/ /
M
>>T
\
�._-- — —.—
o 01)
m
\
PHOTOBEAM DETECTORS
u] 7
E
\
REVERSING LOOP
(PHOTOEYES) TO
/
Q
\
/. CONTROLLER
z w
w
\
0
COMM. LINE BETWEEN
CONTROLLER AND
lJUn
((��
Q)
TELEPHONE
`
TELEPHONE ENTRY
U�J of
a
ENTRY PEDESTAL
w
Iss
ad
Up©
EDGE OF ROADWAY
EDGE OF ROADWAY
l-J
z
a�e
w
LEY
Q
TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
Know what's below.
Call before you dig.
8/23/2024
EXISTING CURB PAINTED RED
W/ "NO PARKING FIRE LANE"
FIRE LANE MARKING
�o
LU
INECT GATE -
-TRICAL
ITROL TO
;TING POWER
w
U
SEE DETAIL FOR v
GATE CONTROL* EXISTING DOUBLE SWING GATE TO
w
APPROXIMATE LOCATION
OF ELECTRICAL LINE
w
EXISTING SIDEWALK
/LU
� I
Q
z
Q
c�
BE REUSED OR REPLACED AT THE
DIRECTION OF C.O.R. FIRE MARSHAL
EXISTING CURB PAINTED RED
W/ "NO PARKING FIRE LANE"
FIRE LANE MARKING
ApAR1MENT ACCESS ROAD
EX.
EXISTING CURB
EXISTING "NO PARKING
FIRE LANE" MARKING
*LOCATION OF DETECTORS AND PEDESTALS
FOR GATE OPERATION TO BE DETERMINED
BY C.O.R. FIRE MARSHAL
EXISTING SOUTH GATE
(NTS)
. Innovative
o . Adaptable
. P rove n
_
. Accepted
. Patented
V
L] Mandated By Public Safety
Agencies Throughout the
CQ United States
L>
cla
Click2Enter, Inc.
emergency access control
Q,Ndc?�
P.O. Box 1532
Sonoma, CA 95476
V Toll Free 877-939-3800
t� click2Enter� Fax it info@click2enter.net
Email info@click2enter.net
www.click2enter.net
SURVEYED:
4
PER CITY COMMENTS
DAF
08/26/24
DESIGNED:
3
PER CITY COMMENTS
DAF
07/29/24
DAF
2
PER CITY COMMENTS
DAF
05/21/24
DRAWN:
TJW, FEM
1
PER CITY COMMENTS
DAF
04/04/24
CHECKED:
NO.
REVISION
BY
DATErAPPR
DAF
APPROVED:
NfE ?1l
Emergency Click2EnterA ccess
Control For...
Gates & Doors
Using your own radio transceivers
ft
W 4 Seconds Count
�J Support Mutual Aid Response
W Gates and Doors Should NOT Delay Your Response
Life Safetyis Absolui
SCALE:
1 "=307
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
Ld
Q
EXISTING
NORTH GATE
Q
0
Q
O
w
U
U
Q
EX. AP AR ROE, T
ACCESS
WOODCLIFFE 0
rn EXISTING
APARTMENTS aN
> SOUTH GATE
aU
U
LU Q
F
Q
CD
Technical Features of The
NEW Click2Enter-LV4
• LARGE FREQUENCY
CAPACITY— 100 CHANNELS
• OPERATES WITHIN ALL OF
THE ALLOCATED FREQUENCY
SPECTRUM— VHF HIGH &
LOW AND UHF HIGH & LOW
• PROGRAMMABLE TIME DELAY
ON MAIN GATE CONTROL
RELAY
• SOFTWARE INTERFACE FOR
EASY PROGRAMMING
• OPERATES IN SUB -ZERO
TEMPERATURES
• CAPABLE OF OPERATING
WITH CTCSS (PL & DPL)
PRIVATE LINE CODING
• BRIGHT ACTIVATION AND
POWER LED'S
• DUAL DRY CONTACT RELAY
OUTPUTS
• RELAYS CAN BE
INDEPENDENTLY
CONTROLLED VIA CHIP
FIRMWARE
• ACTIVATION HISTORY DATA
LOGGING FOR EXPORT TO
COMPUTER FILE
• ENCLOSURE NEMA 4X RATED
• REFLECTIVE FRONT
IDENTIFICATION LABEL TO
SUPPORT FASTER NIGHTTIME
IDENTIFICATION
Learn More Visit: www.click2enter.net
F1ZURR
EN6INEERIN6
SERVICES, PLLC
4715 142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
ICAL: NAVE) 1988
HORIZONTAL- NAD 1983/1991
CITY OF
RENTON
DATU M 0
Planning/Building/Public Works Dept.
VICINITY MAP
(NTS)
No cost to the public safety
agency, because they already
posses the access control device
[KEY]— Their own radio
transceiver.
Don't risk untimely delays during
an emergency response. Every
second counts so forcing the
emergency responder to STOP
their vehicle to enter a code,
activate a key, or not get in at all
can have a catastrophic
outcome.
Operate both gates and doors
for a comprehensive overlay
emergency access response.
Features and benefits of the
NEW Click2Enter-I.V4:
elk
Q Mutual Aid Control
�4 Stealth Operation
%i Improved Response
Time
►; Officer Safety Friendly
0 Provides Increased
Security Over Light &
Siren Systems
I
R-429019
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
NJanders 09/16/2024
GRANT PLACE TOWNHOMES
1600 GRANT AVE S RENTON, WA 98055
PARCEL 2023059052
FIRE GATES DETAIL
DATE:
11/21/23
FIELDBOOK:
PAGE:
20069
SHEET: OF:
C9.0 28
O
Cfl
O
C')
N
A,
u
H
H
C'M
Q
J
H
H
C'7
N
0—
Cn
W
O
>z
O
W
U
Q
J
z
Q
rIt
V
0
1
1
0
L1J
NOTES:
1. TREE INVENTORY BY:
TYEE SURVEYERS
DATED 7-22-2015
(206) 525-3660
2. ARBORIST REPORT (1):
GREENFOREST INC.
DATED 12-21-2015
(206) 723-0656
3. ARBORIST REPORT (2):
SHUFFNER CONSULTING
DATED 10-24-2022
(206) 755-9407
4. TREE RETENTION AND
REPLACEMENT WILL BE IN ACCORDANCE WITH
THE CITY OF RENTON'S MUNICIPAL CODE 4-4-130 'TREE
RETENTION AND LAND
CLEARING REGULATIONS'.
PROPERTY LINE
Ii / [— RIGHT-OF-WAY
6
�O�
�6e
� t
i
e
Q-i
i
ZOi�<v
i
Gj t=Iti
.< ;`4<C/
Ji(44,1
e
PROPOSED RETAINING WALL,
i TYP.
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
/ EXISTING UNDERGROUND
t STORMWATER VAULT # \�
�7 vv
#49 \GRANT CIRCLE S.E.-
\
--- --- -- -- -- --
--------
PROPERTY LINE
TREE RETENTION PLAN
SCALE: 1" = 20'- 0" 0 5' 20' 40'
PORTION OF PARCEE
-
-
-
-
---- — N
—
GRANT CIRCLE S.E.
—
W
—W
-
-
-U)-
11
.0
n
7
J
E
Know what's below.
Call before you dig.
1 1 Report to the Hearing Examiner,10-2-23
NO. REVISION
Z
—
C
1
11/16/23
BY DATE
TREE INVENTORY
(TREE CREDIT
TREE
# SPECIES
DBH
DRIPLINE
HAZARDOUS
RETAINED
COMMENT
PER CITY OF
RENTON, REF
1
ALDER
18",16"
75'
REPORT TO
2
ALDER
18",14"
70'
HEARING
3
ALDER
16",10"
50,
EXAMINER,
4
CEDAR
40",36"
55'
102423, PG, 11
5
CHERRY
1614"
40'
'TREE RETENTION')
6
ALDER
1614"
40'
7
ALDER
18",16",10"
65'
8
DECIDUOUS
10",6"
20'
9
MAPLE
16",14",12"
30'
„--
E
10
MAPLE
10"
30'
11
LOCUST
14",12",10"
100'
12
ALDER
12"
35'
13
ALDER
12"
30'
**14
ALDER
12"
30'
YES
X
CREATE
SNAG
15
ALDER
12"
25'
16
ALDER
12"
30'
* 17
MAPLE
12"
45'
NO
18
MAPLE
12"
40'
19
MAPLE
12
40'
20
ALDER
13"
35'
21
ALDER
13"
25'
22
ALDER
14"
40'
23
ALDER
14"
40'
* 24
ALDER
14"
25'
YES
* 25
ALDER
14"
30'
YES
* 26
ALDER
14"
30'
YES
* 27
ALDER
14"
30'
YES
** 28
ALDER
14"
30'
YES
X
CREATE
SNAG
** 29
ALDER
14"
20'
YES
X
CREATE
SNAG
30
MAPLE
14"
55'
31
MAPLE
14"
50'
32
ALDER
15"
30'
33
CHERRY
15"
50'
34
ALDER
16"
40'
* 35
ALDER
16"
35'
YES
36
ALDER
18"
45'
37
ALDER
18"
45'
38
ALDER
20"
45'
(7)
39
ALDER
20"
50'
(8)
* 40
ALDER
22"
40'
YES
41
ALDER
22"
35'
(8)
42
FIR
22"
35'
(9)
43
ALDER
24"
45'
(9)
* 44
ALDER
24"
50'
YES
X
CREATE
SNAG
45
ALDER
24"
50'
(9)
46
ALDER
24"
40'
TREE IS
DYING
47
FIR
24"
35'
(9)
48
FIR
24"
35'
(9)
49
CEDAR
24"
35'
RCW
(9)
50
ALDER
34"
50'
(12)
51
ASH
36"
75'
(12)
52
CEDAR
36"
50'
(12)
53
CHERRY
36"
60'
(12)
SCREENED
BACK TEXT INDICATES
INVENTORIED TREES
THAT WERE NOT
EXAMINED
BY ARBORIST
*
INDICATES
TREES SURVEYED
IN FIRST
ARBORIST REPORT, 2015
**
INDICATES
TREES SURVEYED
IN SECOND ARBORIST
REPORT, 2022
SURVEYED:
DESIGNED:
TMV
DRAWN.
TMV
CHECKED:
TMV
AP P R I APPROVED
TREE PRESERVATION LEGEND
SYMBOL ITEM DESCRIPTION
EXISTING TREES TO REMAIN
EXISTING TREES TO BE REMOVED
PROPOSED DECIDUOUS TREES
PROPOSED EVERGREEN TREES
TREES SAVED
UNHEALTHY TREES THAT WERE
RETAINED. TO BE SNAGS.
REF LANDSCAPE DWGS, SHEET. L3.1
REF LANDSCAPE DWGS, SHEET. L3.1
49 OF THE EXISTING 53 TREES HAVE BEEN REMOVED. 4 UNHEALTHY TREES WERE
RETAINED AND WILL BE MADE INTO HABITAT SNAGS LOCATED IN THE TREE PROTECTION
AREA. TREE #9 IS LOCATED OFF —SITE AND TREE #49 IS LOCATED IN THE ROW. SEE
TREE RETENTION WORKSHEET AND ARBORIST REPORTS FOR MORE INFORMATION.
SCALE.
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VR
C TY 0F
RENTON
N43119v
Planning/Building/Public Works Dept.
--- Tina Vincent, PLA, ASLA
landscape architect
(206)913-9216
P.O. Box 1744
Edmonds, WA 98020
tina@vindesigngrp.com
NOTES:
1. REQUESTING TO PAY A FEE IN LIEU OF
ANY MISSING REQUIRED TREE
REPLACEMENT PER 4-4-130 'TREE
RETENTION AND LAND CLEARING
REGULATIONS' BASED ON PROVIDING AS
MANY TREES AS THE PROJECT SITE CAN
MAINTAIN WHILE AVOIDING ALL RETAINING
WALL, UTILITIES AND EASEMENTS.
R-429022
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING
Ming 09/03/2024 '
DEVELOPMENT ENGINEERING
NJanders 09/16/2024
GRANT PLACE TOWNHOMES
1600 GRANT AVE S RENTON, WA 98055
PARCEL 2023059052
TREE RETENTION PLAN
DATE:
FIELDBOOK:
PAGE:
DRAWING NO:
SHEET: L 1 .1 F
o)
2
O
Z
O
W
U
J
Q
CD
1
1
C)
W
E 202305— 9013
#9
- I I
I
J iiiiiin- `\ /
-- >- --
LU
2
Cn
LU
LLJ
Z
—
E -- /
U
Q
C \\
I I
�_-
--A-
A
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
PRIVATE ALLEY
\
I
I
I
/I
BECOME 10'-20' HT. WILDLIFE
SNAGS
TREE RETENTION PLAN
SCALE: 1" = 20'- 0" 0 5' 20' 40'
N
Know what's below.
Call before you dig.
OF W AS
PM.VINcF��G
VJ
r �
2�S 7371>1_X P . 08I
C'4 P E P,
Z SURVEYED:
DESIGNED:
TMV
i DRAWN.
TMV
1 Report to the Hearing Examiner,10-2-23 11/16/23 CHECKED:
TMV
N0. REVISION BY DATE APPR APPROVED:
AS SHOWN th '%R
C T Y OF
RENTON
ONE INCH
AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
NOTES:
1. REQUESTING TO PAY A FEE IN LIEU OF
ANY MISSING REQUIRED TREE
REPLACEMENT PER 4-4-130 'TREE
RETENTION AND LAND CLEARING
REGULATIONS' BASED ON PROVIDING AS
MANY TREES AS THE PROJECT SITE CAN
MAINTAIN WHILE AVOIDING ALL RETAINING
WALL, UTILITIES AND EASEMENTS.
--- Tina Vincent, PLA, ASLA
landscape architect
(206)913-9216
P.O. Box 1744
Edmonds, WA 98020
tina@vindesigngrp.com
R-429023
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING 0
Ming 09/03/2024 '
DEVELOPMENT ENGINEERING
NJanders 09/16/2024
GRANT PLACE TOWNHOMES
1600 GRANT AVE S RENTON, WA 98055
PARCEL 2023059052
TREE RETENTION PLAN
DATE:
FIELDBOOK:
PAGE:
DRAWING NO:
SHEET: L 1 1:
0
1
1
C)
LLJ
SITE
CLEAR
ZONE
0
LEGEND
SYMBOL (QTY) NAME NOTES
QP LANDSCAPE BOULDER
® BENCH
PICNIC TABLE / ADA COMPLIANT
o MONUMENT SIGN. DESIGN TBD
�IIiIIIIIIIIIIIIIIIIIIIIIIIIF � �
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
LANDSCAPE SCHEDULE
SYMBOL BOTANICAL/COMMON NAME SIZE AT PLANTING/CONDITION/REMARKS MATURE PNW
TREE SIZE NATIVE
0 DECIDUOUS TREES
38 ACER CIRCINATUM MULTI —STEMMED, MIN (3) 1" CALIPER TRUNKS, SMALL X
VINE MAPLE 10'-12' HT., WELL —BRANCHED, FULL, MATCHED,
5
3
2
2
1(
B&B.
INKGO BILOBA 'PRINCETON SENTRY' MIN. 4" CALIPER, 12-14' HT. WELL —BRANCHED
PRINCETON SENTRY GINKGO
ABOVE
6' HT., MATCHED,
B&B.
GLEDITSIA TRIACANTHOS 'INERMIS'
MIN. 4"
CALIPER, 12-14'
HT. WELL —BRANCHED
SKYLINE HONEYLOCUST
ABOVE
6' HT., MATCHED,
B&B.
HAMAMELIS X INTERMEDIA 'JELENA'
MULTI —STEMMED, 6'-8' HT., FULL TO
BASE, B&B
JELENA WITCH HAZEL
TILIA CORDATA 'CHANCELLOR'
MIN. 4"
CALIPER, 12-14'
HT. WELL —BRANCHED
CHANCELLOR LITTLE LEAF LINDEN
ABOVE
6' HT., MATCHED,
B&B.
ULMUS 'FRONTIER'
MIN. 4"
CALIPER, 12-14'
HT. WELL —BRANCHED
FRONTIER ELM
ABOVE
6' HT., MATCHED,
B&B.
Oz
EXISTING 4' HT.
LANDSCAPE
BLOCK WALL.
PLANT ONE ROW
OF KINNICHINNIK
START EASEMENT, MAINTENANCE ACCESS
ALONG TOP. ALLOW TO
NORTH PROPERTY LINE DRIVE: NDS TUFFTRACK �= CASCADE DOWN WALL. =
I BUFFER PLANTING AREA. LAWN PAVER JCS�� PORTIO N OF P A R C E!
I REF CIVIL DWGS.
e: <c/� SOLID WOOD 10' FULLY SIGHT -OBSCURING
PROPERTY LINE FENCE, HT TBD LANDSCAPE BUFFER, SEE SHEET
I / : L3.2
----------------------------
G RA •
-
,`' I.TABLES F_ C e I
\\ • • I II I I I LL, L LLLi Li LLLLLI LILLL,; _LLL LLLLLLLLLLLLLLLLLLL4. .LLL .C.C.LLLLLLLL LLLLLL
LLL2
1=L6 LII_LL LLLLLLLLLLLLLLLLLLLLLLLZi- t I I I I LLLLL LLLLLLLLLLLLLLtLtL:LL1L_L
-LYLLL LLLLLLLLLLLL
LLLL L LLLLLLLLLLLLLLLLL4L.kLLLLLLL
6LLLLL--6LL-
! I4A
LOC TION
OF ENTRY
MONUM T
I 1 • �1 � � •��\�� o : e o �° a •sea • ° ° °
V �1I�-� ° e• o s • e° s e• o e
jav
-OR
TZ;
AM
.1 MIZ-01119
BUILDING 1
ta1
/...;
FA
BUILDING 21
--��r C�®IWA—
SEATING
PRIVATE
AREA
OPEN SPACE,
Y r 1
II� P/' ►♦©!
�II��I r�i�.��w /�:.�.�--
\i/lil �`-1•/ ��.�,/`YY'�I'©©.,'�©�©"!_-�©W©lel��•
c•�i ©© \ ,arcs
�ov� III/V '7/a9©
��_��©��•��I(�\�/�y��-
�71vi
f�,♦ Q©
I ♦
� �1�+j
������
�►�
�-
oil ` non I�es>'r�
i � - -_
t v" �.�- Ir
Iasi �.
�%/%/////��/
ail I%E'1! 0.0 :�\,�,�,-�: 1�/9I ©� ���
w /
.iw��l�!,►�r—�v�©���� �I�J) vim
�'��
�!'.���p',�I.rsIV��11������:�.U_7�©b'1�
1
�7��� ��
Q�l�v'I,', v/�r'�i >c�
kvvo s� .■C,... .... w�iie�w-
!7 `�©�'✓ ��i �.�! \� \ � ©© y.
I � I � y ��. ��
1�;''�'.,J �' ���'iv���r�;Q'��il;:
��©
\���o�
I�.I
,CAI- L�0'✓:�®.
'
BUILDING
IQI
BUILDING
/ FIRE HYDRANT, TYP. I
DECORATIVE PAVING /
FIRE LANE. NO PARKING �, GRANT CIRCLE S.E.'Mm
�\ ------------- ------------------------
---------------------- --------
10' LANDSCAPE BUFFER, AVERAGED.
SOUTH AND EAST PROPERTY LINES.
UNDERGROUND UTILITIES IN BUFFER STRIP
'L 20'X20' ALONG SOUTH PROPERTY LINE, NO TREES.
SITE CLEAR ZONE
CONCEPTUAL LANDSCAPE PLAN
SCALE: 1 " = 20'- 0" 0 5' 20' 40'
OF W A S
M. v INOF,�,� G
Know what's below. y �0,
'1>
Call before you dig. �scFxP.°$12c,�,��
q PE AR
1 Report to the Hearing Examiner,10-2-23
N0. REVISION
N
SURVEYED:
DESIGNED:
TMV
DRAWN.
TMV
11/16/23 CHECKED:
TMV
BY DATE APPR APPROVED:
SCALE.
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
MEDIUM
MEDIUM
SMALL
LARGE
EVERGREEN TREES
12
PSEUDOTSUGA MENZIESII
DOUGLAS FIR
181
THUJA 'EMERALD GREEN'
EMERALD GREEN ARBORVITAE
13
O
THUJA PLICATA
WESTERN RED CEDAR
6
THUJA PLICATA 'HOGAN'
HOGAN CEDAR
SHRUBS
8'-10' HT., FULL TO BASE, B&B LARGE X
6'-8' HT., FULL TO BASE, B&B
8'-10' HT., FULL TO BASE, B&B LARGE X
8'-10' HT., FULL TO BASE, B&B MEDIUM X
133
®
CORNUS ALBA 'ELEGANTISSIMA'
3 GAL.
CONT.
MIN, 24-30"
HT. & SPR., FULL
VARIGATED DOGWOOD
MEDIUM 42
O
CORNUS SERICEA 'ISANTI'
3 GAL.
CONT.
MIN, 24-30"
HT. & SPR., FULL
X
ISANTI RED TWIG DOGWOOD
65
0
HYDRANGEA QUERCIFOLIA 'ALICE'
3 GAL.
CONT.
MIN, 24-30"
HT. & SPR., FULL
OAK —LEAF HYDRANGEA
2
O
LONICERA JAPONICA
2 GAL.
CONT.
MIN, 18-24"
HT. & SPR, FULL
JAPANESE HONEYSUCKLE
134
Q
MAHONIA AQUIFOLIUM
3 GAL.
CONT.
MIN, 24-30"
HT. & SPR., FULL
X
TALL OREGON GRAPE
133
0
MISCANTHUS SINENSIS 'LITTLE KITTEN'
2 GAL.
CONT.
MIN, 18-24"
HT. & SPR, FULL
LITTLE KITTEN MAIDEN GRASS
34
I`,I
MYRICA CALIFORNICA
5 GAL.
CONT.
MIN, 42"
HT. & SPR., FULL
X
PACIFIC WAX MYRTLE
34
Q
RHODODENDRON 'GIRARD'S CRIMSON'
2 GAL.
CONT.
MIN, 18-24"
HT. & SPR, FULL
EVERGREEN AZALEA
60
0
RIBES SANGUINEUM
3 GAL.
CONT.
MIN, 24-30"
HT. & SPR., FULL
X
RED FLOWERING CURRANT
162
O
SARCOCOCCA HOOKERIANA
2 GAL.
CONT.
MIN, 18-24"
HT. & SPR, FULL
FRAGRANT SWEET BOX
103
O
SYMPHORICARPOS ALBUS
3 GAL.
CONT.
MIN, 24-30"
HT. & SPR., FULL
X
COMMON SNOWBERRY
179
0
VACCINIUM OVATUM
3 GAL.
CONT.
MIN, 24-30"
HT. & SPR., FULL
X
EVERGREEN HUCKLEBERRY
MAY BE
SHEARED,
MAINTAIN HEDGE @ 30" HT.
GROUNDCOVERS / ORNAMENTAL GRASSES
ARCTOSTAPHYLOS UVA—URSI
1 GAL.
CONT.
@ 18" O.C.
TRIANGULAR SPACING,
X
KINNIKINNICK
START
FIRST
ROW 12"
FROM EDGE OF PAVE.
GAULTHERIA SHALLON
1 GAL.
CONT.
@ 24" O.C.
TRIANGULAR SPACING,
X
SALAL
START
FIRST
ROW 12"
FROM EDGE OF PAVE.
HEMEROCALLIS 'STELLA D'ORO'
1 GAL.
POTS
@ 18" O.C. TRIANGULAR SPACING,
Q
DAYLILY
START
FIRST
ROW 12"
FROM EDGE OF PAVE.
HOSTA 'BLUE CADET'
1 GAL
CONT.,
SPACING
AS SHOWN
355
,�p
BLUE CADET HOSTA
LIRIOPE MUSCARI 'BIG BLUE'
1 GAL.
CONT.
@ 18" O.C.
TRIANGULAR SPACING,
BLUE LILY TURF
START
FIRST
ROW 12"
FROM EDGE OF PAVE.
®MAHONIA
REPENS
1 GAL.
CONT.
@ 18" O.C.
TRIANGULAR SPACING,
X
CREEPING MAHONIA
START
FIRST
ROW 12"
FROM EDGE OF PAVE.
POLYSTICHUM MUNITUM
2 GAL.
CONT.
@ 24" O.C. TRIANGULAR SPACING,
X
SWORD FERN
START
FIRST
ROW 12"
FROM EDGE OF PAVE.
r•
HYDROSEEDED LAWN
SEE SPECIFICATIONS
0
EXISTING TREES TO REMAIN
CREATE
SNAGS
n 12'
TO 20' HIS, RFF
CIVIL DWGS
FOR EXACT
LIMITS OF
CLEARING
•
R C TY 0F
RENTON
N430v
Planning/Building/Public Works Dept.
--- Tina Vincent, PLA, ASLA
landscape architect
(206)913-9216
P.O. Box 1744
Edmonds, WA 98020 R-429024
tina@vindesigngrp.com
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING 19 w
Ming 09/03/2024 DEVELOPMENT ENGINEERING W
NJanders 09/16/2024 O
z
O
DATE: W
GRANT PLACE TOWNHOMES FIELDBDGK: VJ
1600 GRANT AVE S RENTON, WA 98055 PAGE:
DRAWING NO: (—
PARCEL 2023059052 zz
SHEET
CONCEPTUAL LANDSCAPE PLAN L3.1GF
ENHANCED LANDSCAPE PROVIDED
DECIDUOUS TREE SIZE
REQUIRED:
1.5" CAL. MIN
PROVIDED:
4" CAL. MIN
REF RMC 4-4-070(L)(4)
'LANDSCAPING'
EVERGREEN TREE SIZE
REQUIRED:
6' HT. MIN
PROVIDED:
8'-10' HT. MIN
REF RMC 4-4-070(L)(4)
'LANDSCAPING'
SHRUB SIZE
REQUIRED:
2 GAL. MIN
PROVIDED:
3 & 5 GAL. MIN
REF RMC 4-4-070(L)(3)
'LANDSCAPING'
GROUNDCOVER
SIZE
REQUIRED:
4" CONT. MIN
PROVIDED:
1 GAL. MIN
REF RMC 4-4-070(L)(2)
'LANDSCAPING'
TREE PROTECTION AREA
1. ALL NEW
PLANTING, FULL COVERAGE. ALL PLANTS ARE NATIVE
SPECIES.
INCLUDING 13 REQUIRED REPLACEMENT TREES.
2. TREE PROTECTION
AREA ENCLOSED BY SPLIT RAIL WOOD FENCE
WITH 2 OPENINGS AND REQUIRED SIGNAGE.
3. SEATING AND NATURE TRAIL PROVIDED FOR ADDED AMENITY.
REF RMC 4-4-130(H)(2)
'TREE RETENTION AND LAND CLEARING
REGULATIONS'.
202305—qn1.-�
10' FULLY SIGHT -OBSCURING
p LANDSCAPE BUFFER, SEE SHEET
L3.2
—------- ---------- -
-
----- ----------- -- ---- -
. Tr DECORATIVE P VI
IN FIRE LANE, TYP. • 0 PARKING ,
_LLLLLLL LLL���- �� L��-r-L LLLL LLLLLLLLLLLLL 6LL LL
�LLLLLLL4LLLLLLL�LLLi..'', _ _... LLLLLLLLI:LL LLLLLLLLLLLL'LL-LL LL LLL
Epp ��fy a�--nBUILDING 2
^IJ
TING
Ir �Rrl.���-171..E
li E ��..: CAREA
LU
I 1 �
1glara
�r—
��...� � v
001
- / 10 �t� � •yea � �It� it
o_ ,.ru•
BUILDING 6
V
N
v
lkffl PIil1
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
END EASEMENT,
NORTH PROPERTY LINE
BUFFER PLANTING AREA.
REF CIVIL DWGS.
RIVER ROCK AT
BASEOF SLOPE/S.
DRAIN OR SUMP AS NEEDED,\TYP.
r
00-0-10: ,Loac A:RPM'.-A..` ,, ;0,Qi :d waWw'd �7.50WM M,%,.►i.�iA �•�7t>rS/A�A.h'�2:�.�_�.V'��.OG`'�
9 WE
U 11�1 �����—�����
•'SOLIDFENCE
WOOD
14
=-�w
�!►
rr
BUILDING 4►�
■
�. ■.�a
�. ..
u nil..1A i
�• nil�l
- -
N
i1�� r[zz�� .alAn/■■�:::::■■■...'III �,,,, t �1l 1�;1�.�..�.■�w�l■�''
a r�� 1.
BE CH,
AOD
:. .....,
,
d1�i
11
BUILDING
/y ../■ /�1//A
AOWN I,
�� HA�(r��
r Iw..,-� � �:I ,�.-, rp,fiel � � � i■e:�
/7 TREE PROTECTION T CT.
t
IN
PROPERTY
10'LANDSCAPE BUFFER, AVER.
•-
SOUTH. EAST PROPERTY
UNDERGROUND UTILITIES IN BUFFER STRIP• :.
ALONG• PROPERTY LINE, NO
CONCEPTUAL LANDSCAPE PLAN
1 1 1 1 41
OF W A Sh,
• �F, PM.VINcF��G
Q VJ
r � �
Know what's below. �0 �
2�73��
S
Call before you dig. cFXP.0g12
q PE RG
1 Report to the Hearing Examiner,10-2-23
NO. REVISION
M
1911
42" HT. SPLIT RAIL FEN
AROUND TREE PROTEI
AREA.
N
SURVEYED:
DESIGNED:
TMV
DRAWN.
TMV
11/16/23 CHECKED:
TMV
DATE APPR APPROVED:
_E
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
C TY OF
RENTON
Planning/Building/Public Works Dept.
NOTES:
1. SEE SHEET L3.3 & L3.4 FOR
OPEN SPACE AND LANDSCAPE
REQUIREMENTS.
- Tina Vincent, PLA, ASLA
landscape architect
(206)913-9216
P.O. Box 1744
Edmonds, WA 98020 R-429025
tina@vindesigngrp.com
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING IS DEVELOPMENT ENGINEERING UJ
Ming 09/03/2024 NJanders 09/16/2024 O
_
z
O
DATE: LU
U
GRANT PLACE TOWNHOMES FIELDS°GK:
1600 GRANT AVE S RENTON, WA 98055 PAGE: a -
DRAWING NO:
PARCEL 2023059052 zz
SHEET
CONCEPTUAL LANDSCAPE PLAN L3 2°F:
0
0
w
PROPERTY LINE
10'�R0TAGE
B FER
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
in' clr_NT ()RC('I ipw(, I onlnC(,opf= PORTION OF P A R C E!
BUFFER REQUIRED, 5' PROVIDED. VARIANCE
REQUESTED. SOLID WOOD PANEL FENCE 4' - UHT.
AND SOLID EVERGREEN HEDGE TO BE MAINTAINED
AT 8' HT.
�o i or 2.
--------
------------------
LLLLL LLLLLLLLLL_- LLLLLL
_ L LL
L--
LLLLLL LLLLL LLLL
V // LL L
G ii r/j % // '_
i LLLLL OPEN SPACE #2 '
% "L� SEATING,LAWN, GARDEN / SEAT{'
i
SL
>5% SLOPE (30% SLOPE) �� + j °
BUILDING 1FRI! BUILDING 2
ram,
SEATING
AREA
, s , 362 SF 256 SF
L 359 SF 261 SF 273 SF 277 SF 330 SF
/ c-J
`,
LLJ
1crH �1 11 r /:� i H H W
LU
!.%:��',/ 1 344 SF I 251 SF -
't%. 368 SF 242 SF 272 SF 260 SF 369 SF
BUILDING 8BUILDING 7
6685 SF 707 SF
OPEN SPACE 3 :
OPEN # R/;
LL SPACE #1 SEATING,LAWN, GARDEN SEA : 75
/ - ,i >5%
} .. LL�� -- �° SLOPE (30% SLOPE) - -� ._
LL - r-- ___ _ __ _LLLL _ L - _ _ - 1 L — • .
j _ r
LLT--��� _ iLLL �LI _=L LLLLL-��_-d_=_____ I-�-= LLLL LLLLL LLLLLLLLLLL __!,-�
`-
LLl'LLLLLLLLLLLL. LLLLLLLLL Ll _ �- �Ty-r^TrLLLLLL LLLL,�,.�,.1- LL______--_
\ LLLLL LLL
LL LLLL4�LLLLLLLLLLLLI LLLLLL4LLLLLL:LLLLLLLLLLLLL _--.,. �4LLLLLLLLLLLLLLLLLLLLLLLiLLLLLLLLLLLLLLLLLLLLLLI LLL LIliLLLLLLLLLLLLLLLLLLLLLLLLL'LLLLL-
I L-Ltiiii'.LLLLLLLLLLLLL��.LLLLLLLLLL6L'LLLLLLLLLLLLLL-�
------------------ ---
------------------------ —
--------------------— — — — — — —
..
C
10' LANDSCAPE BUFFERS ALONG
SOUTH AND EAST PROPERTY LINES,
\ \ AVERAGED. 6 HT. WOOD PANEL FENCE.
UTILITIES ALONG SOUTH BUFFER, NO
TREES. VARIANCE REQUESTED.
OPEN SPACE AND REQUIRED LANDSCAPE BUFFERS
SCALE: 1 " = 20'- 0" 0 5' 20' 40'
N
OF W A S
M. v INOF,�,� G
Know what's below. y �07rp e
Call before you dig. �scXP.OBI 0
q PE AR
1 Report to the Hearing Examiner,10-2-23
NO. REVISION
SURVEYED:
DESIGNED:
TMV
DRAWN.
TMV
11/16/23 CHECKED:
TMV
BY DATE APPR APPROVED:
LANDSCAPE CALCULATIONS
TOTAL PROJECT AREA: 97,229 SF
ROW: 5,177 SF
SITE: 92,052 SF
TOTAL SITE LANDSCAPE AREA:
ROW:
SITE: 29,575 SF
FRONTAGE BUFFER
REQUIRED: 1,219 SF (10' WIDTH OFF SIDEWALK)
PROVIDED: 1,219 SF, INCLUDES RETAINING WALL 3' OFF
SIDEWALK. RETAINING WALL IS PROVIDING
MAXIMUM USABLE 'COMMON' OPEN SPACE AT THE
REQUIRED 5% SLOPE.
PERIMETER BUFFER
REQUIRED: 12,952 SF (10' WIDTH NORTH, EAST, SOUTH)
PROVIDED: 10,101 SF (AVERAGED & INCLUDES TREE PROTECTION AREA)
*CITY APPROVAL IS REQUESTED TO DEVIATE FROM THE PROVISIONS OF SECTION
4-2-115 'RESIDENTIAL DESIGN AND OPEN SPACE STANDARDS' BY PROVIDING AN
'ENHANCED LANDSCAPE' THAT MEETS OR EXCEEDS THE INTENTION OF THIS CODE
REQUIREMENT.
TREE PROTECTION AREA
REQUIRED: 2,457 SF (SEPARATE TRACT)
PROVIDED: 2,457 SF
TOTAL 'COMMON' OPEN SPACE AREA
REQUIRED: 12,600 SF (350 SF X 36 UNITS)
PROVIDED: OPEN SPACE #1 — 6685 SF
OPEN SPACE #2 — 707 SF (>5% SLOPE)
OPEN SPACE #3 — 707 SF (>5% SLOPE)
OPEN SPACE #4 — 707 SF (>5% SLOPE)
OPEN SPACE #5 — 707 SF (>5% SLOPE)
OPEN SPACE #6 — 1657 SF
OPEN SPACE #7 — 278 SF
OPEN SPACE #8 — 2458 SF (>5% SLOPE)
TOTAL — 13,906 SF
*CITY APPROVAL IS REQUESTED TO DEVIATE FROM THE PROVISIONS OF SECTION
4-2-115 'RESIDENTIAL DESIGN AND OPEN SPACE STANDARDS' BY PROVIDING AN
'ENHANCED LANDSCAPE' THAT MEETS OR EXCEEDS THE INTENTION OF THIS CODE
REQUIREMENT.
TOTAL 'PRIVATE' OPEN SPACE AREA
REQUIRED: 250 SF FOR EACH 36 UNITS
PROVIDED: 303 SF FOR EACH 36 UNITS (AVERAGED)
*CITY APPROVAL IS REQUESTED TO DEVIATE FROM THE PROVISIONS OF SECTION
4-2-115 'RESIDENTIAL DESIGN AND OPEN SPACE STANDARDS' BY PROVIDING AN
'ENHANCED LANDSCAPE' THAT MEETS OR EXCEEDS THE INTENTION OF THIS CODE
REQUIREMENT.
SEE SHEET L3.1 FOR 'ENHANCED LANDSCAPE PROVIDED'.
SCALE.
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
•
R C TY 0F
RENTON
N430v
Planning/Building/Public Works Dept.
LEGEND
SYMBOL (QTY) NAME NOTES
'COMMON' OPEN SPACE
------------I
r 1
'PRIVATE' OPEN SPACE
'------------
--- Tina Vincent, PLA, ASLA
landscape architect
(206) 913-9216
P.O. Box 1744
Edmonds, WA 98020
tina@vindesigngrp.com
R-429026
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING DEVELOPMENT ENGINEERING
Ming 09/03/2024 ' NJanders 09/16/2024 U
GRANT PLACE TOWNHOMES
1600 GRANT AVE S RENTON, WA 98055
PARCEL 2023059052
OPEN SPACE PLAN
DATE:
FIELDBOOK:
PAGE:
DRAWING NO:
SHEET: OF
L3.3
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
0
w
GENERAL NOTES:
1. ADDRESS: 1600 GRANT AVE. S RENTON, WA 98055
2. ZONE: RESIDENTIAL MULTIFAMILY (RM—F)
10' SIGHT OBSCURING LANDSCAPE 3. COORDINATE WORK WITH OTHER TRADES AS REQUIRED. DETERMINE
p BUFFER REQUIRED, 5 PROVIDED. VARIANCE LOCATION OF UNDERGROUND UTILITIES AND PERFORM WORK IN A MANNER
REQUESTED. SOLID WOOD PANEL FENCE 4'- 6' HT. WHICH WILL AVOID POSSIBLE DAMAGE. COORDINATE WITH UTILITIES
AND SOLID EVERGREEN HEDGE TO BE MAINTAINED F 3.78:,� UNDERGROUND LOCATION CENTER AND OWNER FOR LOCATIONS OF
�
AT8'HT. - - - -- -, EXISTING UNDERGROUND UTILITIES, ETC. SERVICING OR ROUTED THROUGH
- - a ` i_ V THE SITE.
• - ��� �� ,�i��}. }" �R -- __tt'�.-- , r, 4. PROVIDE PROTECTION OF ALL PROPERTY, PERSONS, WORK IN PROGRESS,
_ - - -
_-------- -------- - _-a
-- - -e + ++ ++ �., - STRUCTURES, UTILITIES, WALLS, WALKS, CURBS AND PAVED SURFACES
DECORATIVE PAVING
p 4 � FROM DAMAGES INCURRED ARISING FROM THIS WORK THE CONTRACTOR
IN FIRE LANE, TYP. NO PARKING\yam �)�— �e� / R- �/ I " H ��� SHALL PAY FOR ANY SUCH DAMAGE AT NO ADDITIONAL COST TO THE
-- LLLLLLLLLLL_L_L-L_ ,r�,I__-� -' -`LLL_tL-rt-LLF�_`t-1L_4LL-LLL•LI LLI LLjLLLL_LLILLLLLcL-ILLLkLLLLLLLLLLLL�LLLLLLLLLLLLLLLLLL L L ::.
I +
y� OWNER.
LLLLCLELLLL LLLLLLLLLLL L 269 S
LIL LLLLL- LLL LL- 'LLLiLLLLLLLL356 SL51 389 5 DURING CONSTRUCTION, KEEP PAVEMENT AND BUILDING CLEAN. PROTECT L
LLLLLLLL
��
SITE AND ADJACENT PROPERTIES FROM DAMAGE DUE TO CONSTRUCTION
707 SF OPERATIONS, OPERATIONS BY OTHER CONTRACTORS, TRADES AND
OPEN SPACE #4 s :%;.rt LL r— 1 TRESPASSERS. UNFINISHED AND COMPLETED WORK SHALL BE PROTECTED
IG,LAWN, GARDENS ,.�,,� L�,,� v FROM DAMAGE BY EROSION OR TRESPASSING, AND PROPER SAFEGUARDS
I
�/; ,, - � - --- �� 328 SIF
(
-)PE 30% SLOPE) �/.,.'"'-''�1 SHALL BE ERECTED TO PROTECT THE PUBLIC.
1657 SF�Qi
OPEN SPACE #6 �/j/,;, ;,,/� `'� I. o °� � 6. VERIFY INSTALLATION CONDITIONS AS SATISFACTORY TO RECEIVE WORK.
,: ; -� SEATING %� BUILDING 4
SEATING AND/% ' % - r '+° DO NOT INSTALL ANY SITE ELEMENTS UNTIL ANY UNSATISFACTORY
;;.;;,,,� - BUILDING 3 s ; �; %/ io=
BUILDING 2 I �>."' - LAWN /! %' %" _ _ - __----_ LLLLLL t, ) CONDITIONS ARE CORRECTED. BEGINNING OF WORK CONSTITUTES
AREA / /I. / 1"P - - LLLLLLL - - LLLLLLLLLL LLLL
LLLLLLL LL--tLtLLLt�L_, ! L�LLLLLLLLLLL._ LLLL. ACCEPTANCE OF CONDITIONS AS SATISFACTORY. WHEN CONDITIONS
i - /�/;/ . ; . - LLL '
�i'1/� ,, •�•l a� / �I 418 __....LL,LLLLLLLLLLLLLLLLLLLLLL LL LLLLLLLLLLLr.I___ -- -` L LLLLLI �''
' i 359 SF 262 SF 262 SF '�% % //'';' f _ __ _ _
67 SF362 SF� % ��; 3O7 SF ; / LL'LLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLL LLLLL
II� � �_..._LLLLLLLLLLLLLLLLLLLLLLLLLLLI=LLLLLLLLLLLLL --- --- �+� r yc LLLLL' �j/�//,,"�, � DETRIMENTAL TO PLANT GROWTH/CONSTRUCTED ELEMENTS, ARE
./}�j 2-78- JR J� ICE -. LLLLLI �z7�
LLLLL ENCOUNTERED SUCH AS RUBBLE FILL ADVERSE CONDITIONS OR
LLLLLI > >
H r " } / ,'; � i SEATING WI H VIEWS DOWN LLLLr z �r
-- -- fir- - , ,>•,, -, i H �' s V �/,�,f�' �,� , I OBSTRUCTIONS NOTIFY OWNERS REPRESENTATIVE.
" ,• f��/;, /�i GARDEN C RRIDOR AND
/ TOW R S THE WEST
-1+ - t + / ��///i
Y ��� %/ �j �'j j/ , LLLLL L
+ +�i
+ + + ] +
LLLLLLLLLLLLLLLLLLLLLLLLL-LLLL LLLLLLLLLLL4LLL7L'LLLLLL.IL�. ------ --- -L LLLLL /%i'i,
L=- ���i f
/ • ,., ---- LLtiLLLLLLLLLLLLLLLLLLLLL�LLLtLLLLLLLLLLLLL♦=tL ---L6LtLLL. .�LLLLLLLLLLtLLLL LLLLL � /,!
PLANTING NOTES:
f LLLLL r LLLLL LLLL
M _ -_---- - �/ %',, j /%///�:'I -J - -LL L LLLLLLLLLLI LLL - L" LL LLL `T .y 1. ALL NEW PLANTINGS WILL BE INSTALLED IN ACCORDANCE WITH CITY OF
cc;o� �./:,.. SEATING AREA +
RENTON'S MUNICIPAL CODE (RMC) 4-4-070 'LANDSCAPING'.
1f H H WITH TRELLIS, TBD Av.�
W _ � �jy, i;,,,./.� � � f—' •, ��� �,/�/ %;':;l poi � ����� 2. TREES TO BE PLANTED AT THE APPROPRIATE SPACING FROM UTILITIES
LL1_f///�' �;i i •��,✓�///�/�.
i �)
AND SIGNS:
354 SF 255 SF 255 SF 283 SF52 SF UTILITY OR SGNAGE DISTANCE REQUIRED
349 SF
/,i, .•/.. .,,� III �"`..•�'//�,/,//''.i� ',\�_'• I I F-_�_— .�
W BUILDING UNDERGROUND UTILITIES 5'
BUILDING 7 - BUILDING 6
//�,�,,/ FIRE HYDRANTS 10'
362 SF 251 SF 283 SF269 SF S 389 - DRIVEWAYS 7.5'
'
LLJ 707 SF // % //.!: ,. iwll LL -
Z LL — — ---
OPEN SPACE #5 LLL UTILITY POLES 10'
R + I•-�-�, STOP & YIELD SIGNS 20
LLLL // V 1 HHH V i + ,
J :ING,LAWN, GARDEN LLL V -1 H C + s
LOPE (30% SLOPE) : =_'� _� ------ LLLLLLL _ `�, /� STREETLIGHTS 25
/��A L•eis S�cG ,lam // LLLLLLL _ L _ _ L LLLLLLL + +�rr� CSc +
/ F _
I I I I .. L L _ ++
-__��_ I -, _ _L, LLLLL-_- .LLLLLLLLLLL L LLL + + + �;__�_-__a�. �_ - ._ .,.4)..__._....___... ,+ w._r' ,
- '� _ _ _ .- a. �.a
- _ 1`' 3. TREE RETENTION AND REPLACEMENT WILL BE IN ACCORDANCE WITH RMC
H _ir """"-- -.LL LLLLLLLLLLLL4LLLLL'LLLL LLLLLL-�-�
�I
LLLL- CE:J�LLLEL,
��__=_____�__LLLLL -_ - t LLLLL LLLLLLL LLLLLLLLLL -- --- , LLLL % I� ������ �� ��- ����� r�
L LLLLLLLLLLLLLLLLLLLLLLLLL LLLLLLLL �� e >
LLttt. LLLLLLLLLLLLL4 _ _
__LLLLLLLLLLLLLLLL ......... : L LL LL LLLLLLLLLLtLLLLLLLLLL _ '--- --` :y� n�. 4-4-130 TREE RETENTION AND LAND CLEARING REGULATIONS'.
r111
p / -► i!;//,��///J,�p��j' �,,�„J y�//��� ��'` �/;`�,,;;,;y / /�! �.% ''�; �; �/�, %/. 4. RIGHT—OF—WAY PLANTINGS AND STREET TREES WILL BE IN ACCORDANCE
_ ;��_� WITH RMC 4 4 070(F)(2) STREET TREES AND LANDSCAPING REQUIRED
WITHIN THE RIGHT—OF—WAY ON PUBLIC STREETS LARGE STREET
�� ---- ---t — — TREES
-------------
��i�"�x'�'!s,"�%./%/;// �� ','���. �'��/,��`/ % a AS PER THE CITY OF RENTON APPROVED TREE LIST AND SPACING
�� GUIDELINES, NOV. 2022 EDITION AT 50' SPACING.
5. OPEN SPACE REQUIREMENTS WILL BE IN ACCORDANCE WITH RMC 4-2-115
10' LANDSCAPE BUFFERS ALONG + PROPERTY LINE 2458 SF 'RESIDENTIAL DESIGN AND OPEN SPACE STANDARDS'.
SOUTH AND EAST PROPERTY LINES, OPEN SPACE #8
AVERAGED. 6 HT. WOOD PANEL FENCE. TREE PROTECTION AREA 6. ALL NEW PLANTINGS WILL BE WATERED BY A PERMANENT AUTOMATIC
UTILITIES ALONG SOUTH BUFFER, NO AMENITIES PROVIDED: NATURE IRRIGATION SYSTEM.
TREES. VARIANCE REQUESTED. TRAIL, SEATING, WILDLIFE VIEWING.
>5% SLOPE (25% SLOPE +/—) 7. SOIL PREPARATION: CULTIVATE PLANTING BED SUB —GRADE TO A MINIMUM
Rnis n—ninnin DEPTH OF SIX INCHES (6") AND REMOVE ALL ROCKS, ROOTS AND DEBRIS
OVER TWO INCHES (2") IN DIAMETER. LAY A TWO INCH (2") DEPTH OF
COMPOST OVER THE ENTIRE BED AND TILL AGAIN TO INCORPORATE
COMPOST THOROUGHLY INTO GRADE.
OPEN SPACE AND REQUIRED LANDSCAPE BUFFERS
SCALE: 1" = 2110" 0 5' 20' 40'
OF W A S
M. v INCF,�,� G
r �
Know what's below. y �07rp e
Call before you dig. �scXP.OBI 0
q PE AR
1 Report to the Hearing Examiner,10-2-23
N0. REVISION
N
SURVEYED.
DESIGNED.
TMV
D<AW.,
TMV
11/16/23 -NECKED.
TMV
BY DATE APPR APPROVED
SCALE.
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VICITY 0E
FENTON
Planning�Building�Public Works Dept.
8. MULCH ALL PLANTING AREAS WITH A MINIMUM THREE INCH (3") DEPTH
OF APPROVED 'MULCH'. FINISH GRADE OF MULCH SHALL BE ONE INCH
(1") BELOW ADJACENT HARD SURFACES AND FLUSH WITH LAWNS.
9. FENCES AND RETAINING WALLS WILL BE IN ACCORDANCE WITH RMC
4-4-040 'FENCES, HEDGES, AND RETAINING WALLS'.
10. SUBMIT COLOR PHOTOS REPRESENTATIVE OF PROPOSED NURSERY STOCK
FOR EACH PLANT SPECIES AND VARIETY LISTED IN LANDSCAPE SCHEDULE.
FINAL APPROVAL OF PLANT MATERIAL WILL NOT BE PROVIDED UNTIL
DELIVERY AND REVIEW ON SITE.
11. CONTAINERIZED TREES ARE STRONGLY DISCOURAGED. TREES WITH LARGE
CIRCLING ROOTS OR TOO DEEP ROOT SYSTEMS WILL BE REJECTED.
12. ALL ROOT PACKAGES MUST BE FREE OF ANY WEEDS.
13. TREE STAKING REQUIREMENTS WILL BE DETERMINED BY LANDSCAPE
ARCHITECT AT THE TIME OF PLANTING. PROPERLY PROPORTIONED AND
PLANTED TREES WITH HEALTHY ROOT PACKAGES MAY NOT REQUIRE
STAKING.
14. ALL TREE STAKES MUST BE REMOVED BY THE CONTRACTOR BY THE END
OF THE FIRST FULL GROWING SEASON.
15. AT THE DIRECTION OF THE LANDSCAPE ARCHITECT, PRUNING MAY BE
REQUIRED TO REMOVE DAMAGED, CROSSING, MISSHAPEN OR LOW
BRANCHING LIMBS. TREES SHOULD NOT REQUIRE SIGNIFICANT PRUNING
TO CORRECT HEALTH OR AESTHETIC DEFICIENCIES.
16. REFER TO CIVIL PLANS FOR NEW UTILITY WORK. CONTRACTOR
RESPONSIBLE FOR PATCH AND REPAIR OF ALL EXISTING LANDSCAPE
AREAS DISTURBED BY CONSTRUCTION WORK UNDER THIS CONTRACT.
17. CLEAR VISION AREAS WILL BE IN ACCORDANCE WITH RMC 4-11-030
'DEFINITIONS C'.
18. WARRANTY: SHALL INCLUDE REPLACING AND PLANTING SAME SIZE AND
SPECIES OF PLANT MATERIAL SHOWN ON DRAWINGS THAT IS DESIGNATED
TO BE REPLACED BY THE LANDSCAPE ARCHITECT. EXCEPT FOR LOSS
DUE TO EXCESSIVELY SEVERE CLIMATOLOGICAL CONDITIONS (20 YEAR
WEATHER CHARTS), INSTALLED PLANT MATERIALS ARE REQUIRED TO BE
GUARANTEED UNTIL THE END OF ONE GROWING SEASON AGAINST DEFECTS
AND UNSATISFACTORY GROWTH, EXCEPT FOR CASES OF NEGLECT BY
OWNERS/OTHERS. ALL PLANTS REPLACED SHALL BE REINSTATED UNDER
THE PLANT GUARANTEE CONDITIONS.
--- Tina Vincent, PLA, ASLA
landscape architect
(206) 913-9216
P.O. Box 1744
Edmonds, WA 98020
tina@vindesigngrp.com
R-429027
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING + DEVELOPMENT ENGINEERING
Ming 09/03/2024 ' NJanders 09/16/2024 '
GRANT PLACE TOWNHOMES
1600 GRANT AVE S RENTON, WA 98055
PARCEL 2023059052
OPEN SPACE PLAN
DATE:
FIELDEOOK
PACE
DRAWING A0:
,TLLI
L3.4
co
2
O
Z
O
U
J
Q
V
1
C
1
BOULDER SIZE
SPECIFICATIONS:
2—MAN
ROCKS
(300-800
POUNDS)
3—MAN
ROCKS
(800-1500
POUNDS)
4—MAN
ROCKS
(1500-2100
POUNDS)
5—MAN
ROCKS
(2100-3000
POUNDS)
LANDSCAPE BOULDER
not to scale
D/iLL UIMIVILIL-IN
13" —18" MIN. NE 1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N., R. 05 E, W.M.
24"-32'''' MIN. GRANT PLACE TOWNHOMES
30"-38" MIN.
Imo.\\I•Z�T•7iU�!7�1�1�•ly! i
NOTES:
• USE THREE 'ARBOR TIE' OR APPROVED
EQUAL, TREE TIES EVENLY SPACED AROUND BASE
F TREE —PLACE FOR LOCAL WIND CONDITIONS.
PLANT TREE 1" HIGHER THAN DEPTH GROWN
T NURSERY.
�BOR TIE' OR APPROVED EQUAL TREE TIES
" DEPTH BARK MULCH
- ANTING BACKFILL MIX — EXISTING
DPSOIL & COMPOST
WATERING BASIN SURROUNDING TREE
K2 HARDWOOD STAKE DRIVE INTO
NDISTURBED SUBGRADE
FINISH GRADE
-MOVE TWINE AND CORD AROUND
;UNK OF TREE
JLL BURLAP OFF TOP 1 /3 OF ROOTBALL
;ARIFY PLANTING PIT WALLS -
-OPE WALLS 1:3
LXISTING SUBGRADE
EVERGREEN TREE PLANTING
not to scale
GROUNDCOVER PLANT. SEE PLANT LIST
3" DEPTH BARK MULCH
_ TOPSOIL DEPTH AND TYPE AS
"=III-�����I���lil���lilllllillllllll��l��l•1=III SPECIFIED
EXISTING SUBGRADE
O O O O
EQUAL PLANT SPACING AS INDICATED ON
DISTANCE PLANT LIST (TYPICAL)
'v EDGE OF PLANTER
60'
8 TYPICAL PLANT SPACING
not to scale
Know what's below.
Cali before you dig.
E
SUBGRADE
CULTIVATE
SUBGRADE
TO 6"
DEPTH.
* SUBGRADE
SHOULD BE
ROUGHLY
7" BELOW
ADJACENT
HARDSCAPE
PLACE 2"
LAYER OF
COMPOST
AND TILL
TO A 6"
DEPTH
SOIL AMENDMENT PROFILE
not to scale
MI r-AIrl IAI-F/l
EXISTING)
GRADE/SLOP
BALL DIAMETER
PLACE 2"
LAYER OF
COMPOST
AND TILL
AGAIN TO
A 6"
DEPTH
PLACE
LAYER OF
MULCH. FINISH
GRADE SHOULD
BE 1" BELOW
HARD SURFACES
AND FLUSH WITH
LAWNS
FINISH
GRADE
COMPACTED
SUBGRADE
NOTES:
• USE THREE 'ARBOR TIE' OR APPROVED
EQUAL, TREE TIES EVENLY SPACED AROUND
BASE OF TREE —PLACE FOR LOCAL WIND
CONDITIONS.
• PLANT TREE 1" HIGHER THAN DEPTH GROWN
AT NURSERY.
— 'ARBOR TIE' OR APPROVED EQUAL TREE TIES
— 3" DEPTH BARK MULCH
— PLANTING BACKFILL MIX — EXISTING
TOPSOIL & COMPOST
— 4" WATERING BASIN SURROUNDING TREE
— 2X2 HARDWOOD STAKE DRIVE INTO
UNDISTURBED SUBGRADE
FINISH GRADE
REMOVE TWINE AND CORD AROUND
TRUNK OF TREE
PULL BURLAP OFF TOP 1 /3 OF ROOTBALL
— SCARIFY PLANTING PIT WALLS — SLOPE
WALLS 1:3
EVERGREEN TREE PLANTING ON SLOPE
not to scale
13ALL UTAML I LK
MULTI -TRUNK TREE PLANTING
not to scale
OF W A S,y
F. M.ViN I�
cF�� C�
ad bd o
20 �lZII
2�Is',37�FXP.08i26\���
Cq PE ARG
NOTES:
• TREE STAKES TO BE VERTICAL,
PARALLEL, EVEN —TOPPED, UNSCARRED
AND DRIVEN INTO UNDISTURBED
SUBGRADE. PLACE FOR LOCAL WIND
CONDITIONS.
• PLANT TREE 2" HIGHER THAN
ADJACENT
GRADE
'ARBOR TIE' OR APPROVED EQUAL
TREE TIES
8 FOOT, 3" ROUND HARDWOOD STAKES,
3 PER TREE
REMOVE TWINE AND CORD FROM TREE TRUNK
3" DEPTH BARK MULCH
4" WATERING BASIN SURROUNDING TREE
FINISH GRADE —
PULL BURLAP OFF TOP 1/3 OF ROOTBALL
PLANTING BACKFILL MIX — EXISTING
TOPSOIL & COMPOST
SCARIFY PLANTING PIT WALLS —
SLOPE WALL 1:3
SET ROOTBALL ON MOUND OF
UNDISTURBED BASE
1 Report to the Hearing Examiner,10-2-23
NO. REVISION
EX
SL
BALL DIAMETER
DECIDUOUS TREE PLANTING
not to scale
SHRUB PLANTING
not to scale
SURVEYED:
DESIGNED:
TMV
DRAWN.
TMV
11/16/23 CHECKED:
TMV
BY DATE APPR APPROVED:
OTES:
TREE STAKES TO BE VERTICAL,
ARALLEL, EVEN —TOPPED, UNSCARRED
ND DRIVEN INTO UNDISTURBED
UBGRADE. PLACE FOR LOCAL WIND
ONDITIONS.
PLANT TREE 2" HIGHER THAN
DJACENT GRADE
'ARBOR TIE' OR APPROVED EQUAL TREE TIES
8 FOOT, 3" ROUND
HARDWOOD STAKES,
3 PER TREE
REMOVE TWINE AND
CORD FROM TREE TRUNK
3" DEPTH BARK MULCH
4" WATERING BASIN
SURROUNDING TREE
FINISH GRADE
PULL BURLAP OFF
TOP 1 /3 OF ROOTBALL
PLANTING BACKFILL
MIX — EXISTING
TOPSOIL & COMPOST
SCARIFY PLANTING
PIT WALLS —
SLOPE WALL 1:3
SET ROOTBALL ON
MOUND OF
UNDISTURBED BASE
• PLANT SHRUB 1 /2" HIGHER THAN
DEPTH GROWN AT NURSERY.
3" DEPTH BARK MULCH
4" WATERING BASIN SURROUNDING PLANT
FINISH GRADE
LIGHTLY SCARIFY ROOTBALL OF
CONTAINER —GROWN PLANTS. PRIOR TO
BACKFILLING
PLANTING BACKFILL — EXISTING
TOPSOIL & COMPOST
SCARIFY PLANTING PIT WALLS
EXISTING SUBGRADE
SET ROOTBALL ON MOUND OF
UNDISTURBED SOIL
SCALE.
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
11111111111111111111111111111uuuulll''�Iniillllllllllllllllllllllllllllllllllll���������������
STREET TREE PLANTING
not to scale
EXISTING
GRADE/SLOPE
�7�1_BLEN
BALL DIAMETER
ROOT BARRIER:
1. ROOT BARRIER SHALL BE RIGID HIGH
IMPACT POLYROPYLENE TREATED WITH UV
INHIBITORS, MINIMUM 18" HEIGHT, WITH
1 /2" RAISED VERTICAL RIBS 6" ON
CENTER, OR APPROVED EQUAL.
2. INSTALL ROOT BARRIER IN CONTINUOUS
STRIP FOR ENTIRE LENGTH OF BED
NEXT TO SIDEWALK AND CURB
ACCORDING TO MANUFACTURER'S
DIRECTIONS. EXPOSED EDGE SHALL NOT
EXTEND MORE THAN 1/2" ABOVE
FINISHED GRADE OF TOPSOIL.
NOTES:
TREE STAKES TO BE VERTICAL, PARALLEL,
EVEN —TOPPED, UNSCARRED AND DRIVEN
INTO UNDISTURBED SUBGRADE. PLACE
FOR LOCAL WIND
• PLANT TREE 2" HIGHER THAN
ADJACENT GRADE
'ARBOR TIE' OR APPROVED EQUAL TREE TIES
8 FOOT, 3" ROUND BVC HARDWOOD
STAKES, 3 PER TREE
REMOVE TWINE AND CORD FROM TREE TRUNK
3" DEPTH BARK MULCH
4" WATERING BASIN SURROUNDING TREE
PULL BURLAP OFF TOP 1 /3 OF ROOTBALL
FINISH GRADE
PLANTING BACKFILL MIX — EXISTING
TOPSOIL & COMPOST
SCARIFY PLANTING PIT WALLS —
SLOPE WALL 1:3
SET ROOTBALL ON MOUND OF
UNDISTURBED BASE
DECIDUOUS TREE PLANTING ON SLOPE
not to scale
A03ftkC TY 0F
RENTON
Planning/Building/Public Works Dept.
--- Tina Vincent, PLA, ASLA
landscape architect
(206) 913-9216
P.O. Box 1744
Edmonds, WA 98020
tina@vindesigngrp.com
R-429028
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING
JDing 09/03/2024 '
DEVELOPMENT ENGINEERING
NJanders 09/16/2024
GRANT PLACE TOWNHOMES
1600 GRANT AVE S RENTON, WA 98055
PARCEL 2023059052
PLANTING & SITE DETAILS
DATE:
FIELDBOOK:
PAGE:
DRAWING NO:
SHEET jr�F
L3.
V)
O
Z
0
Uj
J
Q
(D
0
(N
1
1
0
LU
1
— BLEND INTO
EXISTING GRADE
EXISTING
ROOTBALL DIA.
SHRUB PLANTING ON SLOPE
not to scale
SLOPE
OF F00
TO DRA
FROM F
TYP.
42" HT. SPLIT RAIL FENCE
not to scale
10' - 20' HT. WILDLIFE SNAGS
6ot to scale n
• PLANT SHRUB 1 " HIGHER THAN
DEPTH GROWN AT NURSERY.
3" DEPTH BARK MULCH
4" WATERING BASIN SURROUNDING PLANT
FINISH GRADE
LIGHTLY SCARIFY ROOTBALL OF
CONTAINER -GROWN PLANTS. PRIOR TO
BACKFILLING
PLANTING BACKFILL - EXISTING
TOPSOIL & COMPOST
SCARIFY PLANTING PIT WALLS
EXISTING SUBGRADE
SET ROOTBALL ON MOUND OF
EXISTING SOIL
Know what's below.
Call before you dig.
NE 1 /4 OF THE SW 1 /4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
PLANT SO THAT TOP OF ROOTBALL
IS 1 " ABOVE FINISHED GRADE PLAN
GROUNDCOVER PLANTING - 1 GAL.
not to scale
OF W A Sh,
PMA VINcF��G
z
y Z 0° C�
0 0
73
2�S 7?FXP.0g12�\����
C'4 PE ARG
PLACE FERTILIZER PRIOR TO MULCH
APPLICATION. FEATHER MULCH TO
BASE OF PLANT. NO MULCH SHOULD
TOUCH THE BASE OF THE PLANT.
MULCH DEPTH 2" - 3" MAX
CUT AND REMOVE ENTIRE
CONTAINER FROM PLANT.
SCARIFY ROOTS IN AT LEAST
SIX LOCATIONS ON SIDES AND
AT LEAST TWICE ON BOTTOM.
WATER AND COMPRESS POCKETS TO
ALLOW FOR SETTLING OF BACKFILL.
BACKFILL WITH 3 IMPORTED
TOPSOIL & 3 SITE SOIL.
THOROUGHLY WATER TO SETTLE.
SECTION
6' HT. WOOD PANEL FENCE
not to scale
12 GAUG
WELDED
MESH, 3'
BLACK P
COATING
STAPLE
SIDE OF
SLOPE T
OF FOOT
TO DRAII
FROM P(
TYP.
01 A /+
42" HT. SPLIT RAIL FENCE WITH OPTIONAL METAL MESH
not to scale
NOTES:
1. ALL POSTS TO BE PRESSURE TREATED
LUMBER, ALL OTHER WOOD TO BE TIGHT
KNOT CEDAR.
2. ATTACH RAILS TO POSTS WITH HIDDEN
GALVANIZED BRACKET.
3. ALL HARDWARE TO BE GALVANIZED
STEEL.
4. STAIN ALL WOOD, COLOR TO BE
)APPROVED BY OWNER
TALLATION.
4
3: 1X4, EACH SIDE
0 SPACE BETWEEN SLATS
aTH POST CAP
?AIL: 1X6, EACH SIDE
)OTING 12" DIAMETER
FOOTING ON 6" CRUSHED
EMBED POST INTO
AND POUR CONCRETE.
IF FOOTING AWAY FROM
SIDES. 18" DIAMETER
AND ENDS
ASE
SOIL
12 GAUGE
WELDED WIR
MESH, 3" SO. MAX,
BLACK PVC
COATING OPTIONAL,
STAPLE TO BACK
SIDE OF FENCE
a
- Tina Vincent, PLA, ASLA
landscape architect
(206)913-9216
P.O. Box 1744
Edmonds, WA 98020
tina@vindesigngrp.com
R-429029
vJ
Cw
G
O
Z
O
w
U
Q
J
I—
Q
(D