TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT-
FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY,
BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE
CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD
VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING
UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE
PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE
PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF
FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES.
NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.
GRANT PLACE TOWNHOMES
DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3
LENGTH(FT)
w 0
a 50
a
Ir 100
150
Lj
200
a 250
0
300
Z 350
°D 400
450
LENGTH(FT)
a 0
a 50
Of 100
Lj
150
a 200
250
Z 300
350
400
450
LENGTH FT
a 0
n. 50
of 100
w 150
a 200
0 250
Z 300
ry 350
400
450
LENGTH(FT)
d 0
a 50
100
~ 150
Q 200
0 250
Z 300
350
400
450
PROCEDURE
SLOWLY PRESSURIZE THE PIPE TO 40 PSIC ALL SEWER PIPE SHALL MEET A MINIMUM AIR
ALLOW 2 MINUTES FOR STABILIZATION, ADDING PRESSURE TEST OF 4 0 P S I G FOR 5 MINUTES
AIR AS REQUIRED TO STABILIZE THE PRESSURE WITH NO LOSS OF PRESSURE IF THERE IS A LOSS
AT 40 P S.I.G OF PRESSURE, THEN THE TIME OF THE DROP FROM
35 P S I G TO 2 5 P S I C SHALL NOT BE LESS
THAN THE TIME SHOWN ON THE ABOVE TABLES
AIR TEST TABLE STD. PLAN - 410
PUBLIC WORKS APP
DEPARTMENT (LOW PRESSURE) Martin PastuCtPA26/2020 1 12:
FOR SANITARY SEWERS1%89&AI61FD98B449D
n,am won, wx.ww,eoc DATE
1292
Know what's below.
Call before you dig.
6 IN DIAMETER PIPE
0
50
100
150
200
250
300
350
400
450
500
0
80
160
236
316
396
476
556
632
680
680
140
220
300
380
456
536
616
696
712
708
708
280
360
440
520
600
676
748
744
736
732
728
424
500
580
660
740
780
772
764
756
748
744
564
644
720
800
808
796
788
780
772
764
760
704
784
856
836
820
808
800
792
784
776
772
844
880
860
844
832
820
808
800
792
788
780
908
884
868
852
840
828
820
808
804
796
788
908
888
872
856
844
836
824
816
808
804
796
908
888
876
860
852
840
832
824
816
808
804
TIME SECONDS
6 IN DIAMETER PIPE
0
50
100
150
200
250
300
350
400
450
500
0
80
160
236
316
396
476
556
632
680
680
220
300
380
456
536
616
696
768
760
752
744
440
520
600
676
756
836
840
828
812
804
792
660
740
820
896
932
908
888
B68
856
840
832
880
960
1028
992
964
940
920
900
888
872
860
1100
1084
1044
1012
988
964
944
928
912
900
888
1132
1092
1056
1028
1004
984
964
948
932
920
908
1132
1096
1068
1040
1016
996
980
964
948
936
924
1132
1100
1076
1052
1028
1008
992
976
964
952
940
1132
7104
1080
1056
1036
1020
1004
988
976
964
952
TIME (SECONDS)
6 IN DIAMETER PIPE
0
50
100
150
200
250
300
350
400
450
500
0
80
160
236
316
396
476
556
632
680
680
316
396
476
556
632
712
832
816
804
804
792
632
712
792
872
952
984
952
928
908
888
876
952
1028
1108
1132
1088
1052
1020
992
972
952
936
1268
1284
1224
1176
1132
1100
10fi8
1044
1020
1000
984
1360
1300
1248
1204
1164
1132
1104
1080
1056
1036
1020
1360
13d8
1264
1224
1192
1160
1132
1108
1088
1068
1052
1360
1316
1276
1240
1208
1180
1156
1132
1112
1096
1076
1360
1320
1284
1252
1224
1200
1176
1152
11 32
1116
1100
1360
1324
1292
1264
1236
1212
1192
1168
1152
1132
1116
TIME SECONDS
6 IN DIAMETER PIPE
0
50
100
150
200
250
300
350
400
450
500
0
80
160
236
316
396
476
556
632
680
680
496
576
652
732
812
892
972
948
924
900
884
988
1068
1148
1228
1248
1192
1144
1104
1072
1044
1020
1484
1564
1484
1408
1344
1292
1248
1208
1172
1144
1116
1700
1608
1532
1464
1408
1360
1316
1280
1248
1216
1192
1700
1624
1560
1504
1452
1408
1368
1332
t 304
1272
1248
1700
1636
1580
1532
1484
1444
1408
1376
1344
1316
8/23/2024
DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3
WASTEWATER UTILITY STANDARD NOTES
1 ALL WORK AND MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY
OF RENTON PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND
SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON STANDARD PLANS & SPECIFICATIONS
A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION
2 DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 HORIZONTAL CONTROL
SHALL BE NORTH AMERICAN DATUM 1983/1991 UNLESS OTHERWISE APPROVED BY THE CITY BENCHMARKS
AND MONUMENTS SHALL BE REFERENCED ON THE APPROVED PLANS
3 A PRE -CONSTRUCTION CONFERENCE AND A 24-HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW
CONSTRUCTION IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS,
INCLUDING STREET USE PERMITS, PRIOR TO STARTING CONSTRUCTION INSPECTION WILL BE ACCOMPLISHED
BY A REPRESENTATIVE OF THE CITY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC
WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION
4 THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS
UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AN APPROVED TRAFFIC
CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT-OF-WAY
5 CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND
FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE IN ACCORDANCE WITH LOCAL,
STATE AND FEDERAL REQUIREMENTS.
6. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE
THE CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF RCW 19 122 A DIG TICKET SHALL BE
OBTAINED A MINIMUM OF TWO BUSINESS DAYS PRIOR TO STARTING ANY EXCAVATION THE CONTRACTOR
SHALL HAVE A COPY OF THE DIG TICKET ON SITE AT ALL TIMES
7. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH
OF 12-INCHES, MAXIMUM DEPTH 18-INCHES, THOROUGHLY COMPACTING EACH LAYER TO 95 PERCENT OF
MAXIMUM DENSITY THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE
PIPE OR TO THE SIDE OF THE TRENCH MATERIALS TO COMPLETE THE FILL OVER THE PIPE SHALL BE
EQUIVALENT TO BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19).
B SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER-GASKETED ASTM D 3034, SDR 35,
C900/C905 OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE CITY
9 SANITARY SEWER PIPES SHALL NOT BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, ETC)
UNLESS APPROVED BY THE CITY IF A SANITARY SEWER IS TO BE LOCATED UNDER ANY STRUCTURE (WALL,
BUILDING FOUNDATION, ETC.), IT SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE
OF WASHINGTON IN ACCORDANCE WITH STANDARD DETAIL 412
10. OPEN -CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAYS SHALL BE
BACKFILLED WITH CRUSHED SURFACING AGGREGATE (WSDOT SPECIFICATION 9-03 9(3) AND MECHANICALLY
COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY
11 ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH
THE STANDARDS AND SPECIFICATION OF THE CITY AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS
AND SPECIFICATION AS APPROVED AND MODIFIED BY THE CITY IN THE RENTON STANDARD PLANS &
SPECIFICATIONS THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE
FOUNDATION MATERIAL TO A UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED
ON A UNIFORMLY DENSE, UNYIELDING BASE PIPE BEDDING SHALL BE IN ACCORDANCE WITH STANDARD PLAN
405
12 ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF
THE CITY FOR THE PREVENTION OF ON -SITE EROSION BOTH DURING CONSTRUCTION AND AFTER THE
COMPLETION OF CONSTRUCTION IN ACCORDANCE WITH THE CURRENT SURFACE WATER DESIGN MANUAL
13 THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH A RECORD DRAWING OF THE SANITARY SEWER
SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED
PROFESSIONAL SURVEYOR
S PLAN - 413
PUBLIC WORKS WASTEWATER UTILITY APPROVED
DEPARTMENT STANDARD NOTES Martin PastuchaLO/26/2 20
rwic wo,lu no,nw,ccnn DATE
SURVEYED:
4
PER CITY COMMENTS
DAF
08/26/24
DESIGNED:
3
PER CITY COMMENTS
DAF
07/29/24
DAF
2
PER CITY COMMENTS
DAF
05/21/24
DRAWN:
TJW, FEM
1
PER CITY COMMENTS
DAF
04/04/24
CHECKED:
N0.
REVISION
BY
DATE
APPR
DAF
APPROVED:
SCALE:
1 "=30'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
M
FURR
I
GINEERING
.ERVICES, PLLC
4715142nd PI. SW #B,
Edmonds, WA 98026
ph 206.890.8291
S-429004
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING 7j)+
IL
NJanders 09/16/2024
WASTEWATER UTILITY
jstowell 09/12/2024
DATE:
VERTICAL: NAVD 1988 GRANT PLACE TOWNHOMES
HORIZONTAL: NAD 1983/1991 11 21 23
+ CITY OF 1600 GRANT AVE S RENTON, WA 98055 FIELDBooK:
RENTON
DATU M PARCEL 2023059052 DRAWING N0:
Planning/Building/Public Works Dept. 20069
SANITARY SEWER DETAILS SHEET: OF:
C5.3 28
O)
O
CO
N
Ir
U
75
r— �
M
Q
J
N
T
1
N
Cn
W
0
2
Z
O
W
U
Q
J
z
Q
r�
V