Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutLUA98-136 Large Format00
N
0
's
0
0
0
■
3333
3329
Conc ter e
Drivewav
3325
s
A- 20 _
AS-1 9 s i"
/ VE-1 Concrete
AS-18, / ay
VE-13 00
y
/ S-17
3330
(VE-1 Concrete
Driveway
AS —1
�. 1 foot diameter tree
25 feet tall
I
E 0
KT AVE
22 •�\
I
16"0 Ductile Iron
I of
SE
�`� Sprinkler box
VE-8 AS-13 1 AS-12 VE-7 \
AS-15 _ J
I 1 - -VE-9 •
VE-16I Proposed Southern 5-14
P d
Equipment laygroun
—W_ \
Enclosure
O O 2' high O
2 foot diameter tree concrete wall
30 feet tall
\ Concrete
2 foot diameter tree
\ ° 30 feet tall
O
\ ° �2 foot diameter tree
�_45 feet tall
Concrete slab
Southern System
�- 2 foot diameter tree
30 feet tall
Sidewalk concrete (typ.)
Maplewood Park
T
R/W
Curb (typ.)
Grass (typ.)
EXPLANATION:
SEE LEGEND & SYMBOL SHEET
Restroom
8' chainlink fenc
with slats --�
Curb
typ.)
Grass
(typ.)
3425
32
3429
sidewalk (tvp.
Concrete AS-10 VRS.
\ 4' chainlink fence
Baseball AS-11 O
Diamond _ _ O
—•-- —Grul s �
\ •17
O \ O 20" Pipeline (OPLC) 8' deep
16" Pipeline (OPLC) 5.5' deep
Added trenching t I Northern System south vapor
extraction exhaust to
north enclosure for
vapor treatment. \
\
V;
\
Asphalt path
U
Notes: 1. The locations of all features shown are approximate.
2. Underground utilities to be verified by locate. Not all utilities are shown.
Reference: Drawing entitled "Cedar River Recovery Area Plot Plan" by Olympic Pipe Line Company, 10/16/86.
AS 8
AS-7
AS
VE-6
Asphalt
Playground
surface
R/W
OPLC
Concrete
Drivewav
Legend
v J Description
�J Total Site Area (square feet)
Proposed Floor AArea and Building Area
(square feet)
Proposed Piping Trench Total (linear feet)
Percentage of Lot Coverage
Parking Analysis
Interior Parking Lot Landscaping
All Other Landscaping
Allowable Building Height
Proposed Building Height
Building Setbacks Required by Code
Proposed Building Setbacks
3508
—R / —
VE— 5
II
AS-3
VE— 4
AS-2
3' diameter tree
VE-3 40 feet tall
�I 43
AS-1 Block Valve Enclo ure
jGr
pop
I` AS-4
w
ire ' I —2 �.
ydranj i
I 4
I
\I
Geoff/Engineers
8' High Chainlijk Fence
I
posed Northern--
iipment Enclosure
�s
PROJECT: REMEDIATION SYSTEM
FACILITY: OLYMPIC PIPE LINE COMPANY
Maplewood Neighborhood
Renton, WA
1 DATE: 9/01 /98 [SHEET 3 OF 8
TITLE:
DRAWING No. 3
Dimensions
43,225
Two equipment enclosures at 400 square
feet each, total 800 square feet
1.400 feet
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
8 foot fencing
Not applicable
Not applicable
30 0 15 30
SCALE IN FEET
SITE PLAN
th
clv of
SAP 01 1938
P!Ecoveo
N
0
00
0
00
M
N
0
3333
`'oncrete
Drive 'oy
TP-1
T
AS 2
VE IO
AS-19� VE-11 Concrete
G Walkway
AS- 18 VE-12
VE-13 3330
AS-17 Concrete
' Driveway
/ VE-14
SAS-16 / 1 foot diameter tree
' -25 feeta
NEWPORT AVE SE
PLACE PIPING TRENCHES AND WELLS
BENEATH MIDDLE OF SIDEWALK
22 0\ 34
16"0 Ductile Iron Water Line
20 feet North of Centerline
I \I
528
' VE 1 ' 110' VE-8 AS-13 AS-12 VE-7 \
l —
8
' 1 Min. VE-9
30
E-16 Proposed Southern --rr
Equipment Playground AS-14
Enclosure
O O 2' high O O
\ ,,-2 foot diameter tree concrete wall —
° 30 feet tall
2 foot diameter tree
30 feet tall
�- 2 foot diameter tree
45 feet tall
Concrete slab
,� 2 foot diameter tree
(OD 30 feet tall
Sidewalk concrete (typ.)
Maplewood Park
\ R/W
Curb (typ.)
Grass (typ.)
E)(PLANATION:
SEE LEGEND & SYMBOL SHEET
Concrete
Southern System
Restroom
n
8' chainlink fence
Curb
(typ.) \
Grass
(typ.) \
3425 \
32 \
Z
sidewalk (typ.) \ U)
Sprinkler box with slats MANIFOLD
REMOVED
ASI 9"
Concrete AS-10 VRS-1
4' chainlink fence
\ � Baseball AS-11 O AS 8 x
\Diamond O
\
x
\ • 17
AS-7
r
\ O
20" Pipeline (OPLC) 8' deep O
16" Pipeline (OPLC) 5.5' deep
Added trenching to Northern System
connect south vapor
extraction exhaust to
north enclosure for
vapor treatment. \ O
(jn STORM DRAIN
\ APPROX. 4 DEEP
Asphalt path
Notes: 1. The locations of all features shown are approximate.
2. Underground utilities to be verified by locate. Not all utilities are shown.
Reference: Drawing entitled "Cedar River Recovery Area Plot Plan" by Olympic Pipe Line Company, 10/16/86.
AS-6�
VE-6
I
Asphalt
playground
surface ,
R/W
OPLC
3508
Concrete
Driveway
_R/W — —
VE-5
4"0
AS-3
18
I VE-4
AS-2
II 3' diameter tree I
(n VE-3 40 feet tall
(-n 43
AS-1 Block Valve Enclo ure
Gra 38
Con to
h
0 \ �`k —
' � I— AS-4
w it— —
VE- 2
Fire 1
r
hydran I V \ 3 o'
AS-5
lZ
\I
Its Illa.rlp' r#���1N 1�1� [ f Engin,.eers
20�"- 8' High Chainlink Fence
t'
I
Proposed Northern
Equipment Enclosu
�s
PROJECT: REMEDIATION SYSTEM
FACILITY: OLYMPIC PIPE LINE COMPANY
Maplewood Neighborhood
Renton, WA
1 I DATE: 9/01 /98 I SHEET 3 OF 9
TITLE:
Jo 1F 30
9C" M FEET
SITE PLAN
DRAWING No. 3A 3 (�
r
U
N
O
O
00
O
00
C\
00
CD
22 •
14
AS-200)jy
VE-10
AS-19 �M VE—j'
AS-18 ' /ET,1 ,
150 '
AS-17
)Y�VE-14 ,'NOTE:
ALL PIPING TO DAYLIGHT INTO ENCLOSURE
AS-16 % ' ,% LINES BROKEN FOR GRAPHIC REPRESENTATION, TYP.
,--------- ------------------------ ---- ------------- -------
-------------------- ----
__ �.
16
AS-15 f-
O VE-16
�I
34•.
NOTE:
PROPOSED PIPING TO BE PLACED
ADJACENT TO EXISTING PIPING-
0 32
BURIED MANIFOLD
10
---------___-------,
0 20
VE-5
i
E=*l VE-4
AS-2
'' VE-3
' 43
pAS-1
• 38
r-
VE— 2
AS-5
VE-1
LEGEND
1 " DIA.
SCH 80 PVC
AIR SPARGING
3" DIA.
SCH 40 PVC
-------------------------------_
VAPOR
EXTRACTION
6" DIA.
PVC
VAPOR
EXTRACTION (EXISTING)
(TO BE
FIELD VERIFIED)
6" DIA.
PVC PERFORATED
VAPOR
EXTRACTION (EXISTING)
(VRS-1)
10" DIA. PVC
_
- VAPOR
EXTRACTION (EXISTING)
(TO BE
FIELD VERIFIED)
SOUTH
VAPOR DISCHARGE
AND CONTROL WIRING
TO NORTH ENCLOSURE
NOTE:
ALL PIPING TO DAYLIGHT INTO ENCLOSURE
LINES BROKEN FOR GRAPHIC REPRESENTATION, TYP.
Site North
30 0 15 30
SCALE IN FEET
0