Loading...
HomeMy WebLinkAboutCA_2021 WSEC_Worksheet_240709_v1John Gabriel Spruell CGP 253-312-5523 gabe@pacifichomesource.com Pacific Home Source LLC 4001 72nd Street East Tacoma, WA 98443 2021 WSEC WORKSHEET – CLIMATE ZONE 4, 5&6 DATE: 7-9-24 PROJECT#: PHS24.009 PLAN: Bull ADU SITE ADDRESS: 5424 NE 10th St Renton, WA 98059 WSU Code Compliance Calculator, WSEC 2018 Project Information Messages / Results * Tristan Bull, Bull Accessory Dwellihng Unit 5424 NE 10th St Renton, WA 98059 UA Reduction = 14.46, Proposed UA is better than baseline by 9% Contact Information Pacific Home Source Gabe Spruell - 253-312-5523 Whole House Mechanical Ventilation Airflow Rate: 30 CFM with Run Time Percent of 100%, Balanced, Distributed ANALYSIS SET UP What code compliance pathway are you using? Project Building Type? Occupancy Type? Code Version?WSEC-R Rev: Oct. 2023, https://www.sbcc.wa.gov/sites/default/files/2023-12/OTS-5010.1_post.pdf Classification:Small Dwelling Unit -- 968 sq. ft. Baseline Description: Code Baseline - Baseline and proposed window areas are equal. About Your Selection:Up to 15 sf exempt window and 24 sf exempt door allowable RESULTS - Comparison of Baseline and Proposed Design Component Performance, R occupancies U *Area UA Area UA Doors U =0.300 0 0.0 0 0.0 Overhead Glazing U =0.500 0 0.0 0 0.0 Vertical Glazing U =0.300 171 51.2 171 42.6 Flat/Vaulted Ceilings U =0.024 968 23.2 968 23.2 Wall (above grade) U =0.056 1,056 59.1 1,056 57.0 Floors over Crawlspace U =0.029 956 27.7 956 23.9 Slab on Grade F =0.540 0 0.0 0 0.0 Below Grade Wall U =N/A 0 0 0.0 Below Grade Slab F =N/A 0 0 0.0 * Values from Table R402.1.2 (Oct 2023) Baseline UA Total 161.2 Proposed UA Total 146.8 Required Credits 5.0 Proposed Credits 5.0 from Tables 406.2 and 406.3 UA Percent Reduction 9.0% UA Reduction 14.5 If the Proposed UA ≤ the Target UA, and the Proposed Credits from Table 406 are ≥ those required in Section R406, then the home meets the WSEC. Total Credits (406.2 & 406.3) 5.0 0.250 0.024 0.054 0.025 Proposed Design Table R406.3 UA Trade Off U Baseline New Construction R3 Single family homes and duplexes WSEC 2021 1.0 Brief Description of Selected Options*Category Select System TypeSystem No. 5 Fuel Normalization Credits (406.2) 1 Option 3.5 3.0 Full Description For heating system based on electric resistance with (1) inverter driven ductless mini- split heat pump system installed in the largest zone in the dwelling OR (2) With 2kW or less total installed heating capacity per dwelling High Efficiency HVAC Energy Credits 3.11 Option 3.11High Efficiency HVAC: Smart Thermostat 0.5 Connected Energy Star Certified smart thermostat. Table R406.2 Energy Equalization Credits 2.0 Electric Resistance with Ductless Heat Pump OR electric resistance with max 2 kW installed capacity Select Options Option 1.2 Perscriptive compliance per Table 402.1.3 / U-0.25 vertical fenestration / R-38 floors or R-10 perimeter & fully insulated slab. Or 15% reduction in UA per section R402.1.5 Table R406.3 Energy Credits Option No. 2 Air Leakage Control and Efficient Ventilation Efficient Building Envelope 3.1 -3.10 Energy Credits (406.3) * Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ. Ductless Mini Split Heat Pump W/ Zonal Control. Min HSPF2 of 9 (HSPF of 10) installed in largest zone of the home and primary heat is Zonal Elec Resist Heat 1.5 1/25/2024https://d.docs.live.net/50d71b58ec65f5ce/1. PHS LLC/Vaults/2024 - Vault/24.009 - Bull^J Tristan ^0 Leah- ADU - 2-9-24/2021 Energy Calculations/WSU_C32021_20240223^FMaster.xlsm 7/9/2024 WSU Code Compliance Calculator, WSEC 2018 Renewable Electric Energy kWh Energy Credits *Refer to WSEC 2015 Table R406.2 for complete option descriptions and requirements 4 Not Selected 0.0 0.0 High Efficiency HVAC Distribution System 7 Appliance Package Efficient Water Heating: Drain Heat Recovery Efficient Water Heating Efficient Water Heating: Compact Hot Water Distribution 5.1 5.3-5.8 5.2 6 0.0 3.0 0.0 - 0.0 0.0 1/25/2024https://d.docs.live.net/50d71b58ec65f5ce/1. PHS LLC/Vaults/2024 - Vault/24.009 - Bull^J Tristan ^0 Leah- ADU - 2-9-24/2021 Energy Calculations/WSU_C32021_20240223^FMaster.xlsm 7/9/2024 WSU Code Compliance Calculator, WSEC 2018 THERMAL ENVELOPE DETAILS - Proposed Design Conditioned Floor Area, Proposed Design 968 sq. ft Classification Small Dwelling Unit Exterior Doors Plan Component Door ID Description Ref.U Qt.Feet Inch Feet Inch Area UA Exempt U=0.28 - 0.28 1 3 0 6 8 20 5.6 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 Sum of Area and UA (excluding exempt door)0 0.0 0 0 Exterior Doors Area Weighted U Overhead Glazing Plan Component Glazing ID Description U Feet Inch Feet Inch - - - - - 0.0 0 0 0 Overhead Glazing Area Weighted U Vertical Glazing Schedule Rows to Show 12 Plan Component Glazing ID Description U Feet Inch Feet Inch Exempt - - - 1 U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 2 6 0 2 0 24.0 6.00 2 U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 7 3.00 0 5 0 105.0 26.25 3 U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 1 5 0 2 0 10.0 2.50 4 U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 3 3 0 3 6 31.5 7.88 5 - - 6 - - 7 - - 8 - - 9 - - 10 - - 11 - - 12 - - Sum of Area and UA 170.5 42.6 0 Vertical Glazing Area Weighted U 0.250 Vertical Glazing and Doors Area Weighted U 0.250 Flat/Vaulted Ceilings Plan Component Attic ID Description U R60 blown Attic STD baffled (2021 Code Baseline)10-7 0.024 968 23.2 968 23.2 0 Walls (Above Grade) Plan Component Wall ID Description Ref.U UA UA Area UARef. Sum of Area and UA Net Area Ref. Ref. Height Notes Height Area Width Qt. Sum of Area and UA Qt.UAArea HeightWidth Width 1/25/2024https://d.docs.live.net/50d71b58ec65f5ce/1. PHS LLC/Vaults/2024 - Vault/24.009 - Bull^J Tristan ^0 Leah- ADU - 2-9-24/2021 Energy Calculations/WSU_C32021_20240223^FMaster.xlsm 7/9/2024 WSU Code Compliance Calculator, WSEC 2018 R21 cavity+R0 foam INT 2X6W Lap (2018 Code Baseline)10-5 0.054 1,056 57 1,056 57 0Sum of Area and UA 1/25/2024https://d.docs.live.net/50d71b58ec65f5ce/1. PHS LLC/Vaults/2024 - Vault/24.009 - Bull^J Tristan ^0 Leah- ADU - 2-9-24/2021 Energy Calculations/WSU_C32021_20240223^FMaster.xlsm 7/9/2024 WSU Code Compliance Calculator, WSEC 2018 Floor (over crawl or exterior) Plan Component Floor UA ID Description Ref.U R38 vented Joist 16oc (2021 1.2, 1,3; 2018 1.3-1.5)10-3 0.025 956 24 956 24 0 Slab on Grade (less than 2 feet below grade) Plan Component Slab ID Description Ref.F FP No slab on grade NA - 0 0 0 0 Below Grade Walls and Slabs Plan Component Slab Wall Wall Wall Slab ID Description Depth Ref.U Area UA UA Sum of Area, Length and UA 0 0.0 0 0 0 Links to Download Forms, Checklists and Other Resources Compliance Certificate Instructions Insulation Certificate for Residential New Construction Duct Testing Affadavits Existing Construction New Construction Prescriptive Checklist for 2018 WSEC Alterations (Remodel) Worksheet Show Ventilation Requirements Conditioned Floor Area 968 sq. ft. Number of Bedrooms 1 Run-Time Percent in Each 4-Hour Segment 100% Is the system Balanced?Verify system meets definition of 'Balanced Whole-House Ventilation' Is the system Distributed?Verify system meets definition of 'Distributed Whole-House Ventilation' Ventilation Code Section IRC, Chapter 15 Whole House Mechanical Ventilation Airflow Rate 30 CFM Show HVAC Thermal Distribution System Download RS-33 (2018) Is this a hydronic heating system? Location of Ducts Location of Air Handler Is Duct Testing Required?No Show Heating System Sizing - Proposed Design Try Out BetterBuiltNW's HVAC Sizing Tool: Nearest Weather Station Indoor Design Temperature 70 F Outdoor Design Temperature 24 F Design Temperature Difference (∆T)46 F Conditioned Floor Area, Proposed Design 968 ft2 Conditioned Volume 7,744 ft3 0.00 Leave blank to use default of 8.5 ft. ceiling height HVAC System Type Location of HVAC Distribution System Unducted All Other Systems (not heat pump) F Slab Slab Perim Renton Unducted Show Heating System Sizing? Area No Sum of Perimeter and FP Slab Perim Compliance Certificate Insulation Certificate Sum of Area and UA Distributed Balanced Show Distribution System Calculator? Show Ventilation Calculator? http://www.energy.wsu.edu/Documents/Duct%20Testing%20Standards%20_2018%20WSEC.pdf Unducted https://betterbuiltnw.com/resources/hvac-sizing-tool Link Prescriptive Checklist Affidavit, Existing Affidavit, New Worksheet 1/25/2024https://d.docs.live.net/50d71b58ec65f5ce/1. PHS LLC/Vaults/2024 - Vault/24.009 - Bull^J Tristan ^0 Leah- ADU - 2-9-24/2021 Energy Calculations/WSU_C32021_20240223^FMaster.xlsm 7/9/2024 WSU Code Compliance Calculator, WSEC 2018 Sum of UA, including exempt door and window 152 Envelope Heat Load 7,010 Btu / Hour Sum of UA X ∆T Air Leakage Heat Load 3,847 Btu / Hour ((Volume X 0.6) X ∆T) X .018)) Building Design Heat Load 10,857 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 10,857 Btu / Hour For ducts located in unconditioned space: Sum of Building Heat Loss X 1.1 For ducts located in conditioned space or ductless: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 15,199 Btu / Hour Building and Duct Heat Loss X 1.25 for heat pumps 4.5 kW Building and Duct Heat Loss X 1.40 for all other systems 1/25/2024https://d.docs.live.net/50d71b58ec65f5ce/1. PHS LLC/Vaults/2024 - Vault/24.009 - Bull^J Tristan ^0 Leah- ADU - 2-9-24/2021 Energy Calculations/WSU_C32021_20240223^FMaster.xlsm 7/9/2024