Loading...
HomeMy WebLinkAboutR-42782200 N It O 1 0 W W� J LANDING GRADE BREAK - SEE CONTRACT PLANS - 4' - 0' MIN. CEMENT CONCRETE SIDEWALK - SEE DOTE 5 FLARE (TYi'.) 3l8ff' EXPANSION ,JOINT (TYP.) SEE STANDARD PLAN F-30.10 GRADE BREAK CURB. OR CURB AND GUTTER -- - 5EE NOTE 4 FACE OF CURB MEASURED PARALLEL TO CURB (TYP,) SLOPE TREATMENT - SEE STANDARD PLAN F-30.10 CROSSWALK CURB RAMP WIDTH 4'- 0" MIN. LANDING TO MATCH A CURB RAMP WIDTH - SEE CONTRACT PLANS CURB RAMP WIDTH 4'- 0" MIN. LANDING TO MATCH CURB RAMP LANDING I VADTH - SEE CONTRACT PLANS GRADE BREAK I cuRa RAMP FF- CONTRACT PLANS � CEMENT CONCRETE GRADE BREAK 4'- 4" MIN- SIDEWALK - SEE NOTE 5 PROVIDE SMOOTH TRANSITION TO SIDEWALK WIDTH' _ q" (TYP.) SEE CONTRACT PLANS - MIN. SEE CONTRACT 4- - 0" MIN. PLANS } 4'- 0" MIN. 3/8" EXPANSION BUFFER. WIDTH - MATCH JOINT (TYP.) - SEE yr TO CURS RAMP DEPTH CURB RAiv1#� STANDARD PLAN F-30.10 {TYP.} GRADE BREAK TRANSITION TO SIDEWALK BUFFER, IF 'k " PRESENT, OR TO BACK OF CURB (TYP.) -• " SEE CONTRACT PLANS wr -- -- - CEMENT CONCRETECURB. DR CURB AND CUTTER PEDESTRIAN CURB - - - " - DETECTABLE WARNING SURFACE - SEE NOTE 4 I SEE NOTE 4 IS SEE STANDARD PLAN F45.10 I DETECTABLE WARNINO SURFACE v FACE OF CURB SEE STANIDARD PLAN F-45.10 _ DEPRESSED CURB AND GLITTER - DEPRESSED CURD AND GUTTER SEE NOTE 4 CROSSWALK L PLAN VIEW TYPE PERPENDICULAR A LANCING CEMENT CONCRETE ;.1 CONTRACTION JOINT (TYP.) -- SEE STANDARD PLAN F-30.10 FOR CURB RAMP LENGTHS GREATER THAN 8' - 0" PROVIDE CONTRACTION JOINT EQUALLY SPACED 4'- 0" MIN. CC. PLAN VIEW DETECTABLE WARNING SURFACE SEE STANDARD PLAN F-46.10 4' - 0" MIN. I- 15" - 0" MAX. {TYP.) SEE CONTRACT PLANS 7k CURB RAM SEE NOTE 7 GRADE BREAK P k 1 P CL 1 SECTION CEMENT CONCRETE CURB RAMP "TYPE PERPENDICULAR "A" PAY LIMIT SEE DETECTABLE WARMING SURFACE SEE ^STANDARD PLAN F-45,10 DEPRESSED CURB AND GUTTER SEE MOTE 4 CEMENT CONCRETE CURB AND GUTTER - SEE NOTE 4 CURB RADIUS DETAIL TYPE PERPENDICULAR B (SHOWN WITH BUFFER) GRADE BREAK COUNTER SLOPE } 5.0% MAX. TOP OF ROADWAY DEPRESSED CURB AND GUTTER - SEE STANDARD PLAN F-10.12 ISOMETRIC MEW TYPE PERPENDICULAR ►4 PAY LIMIT WSDOT PERPENDICULAR CURB RAMP F-40.15-04 NOT TO SCALE 0 0 U�O a Know what's below. Call before you dig. T . of WA$a;/f �ECISTERE9 �sSI�NAL �1 09/10/2024 CEMENT CONCRETE GARB RAMP "TYPE PERPENDICULAR "B" PAY LIMIT T A C O M A • S E A T T L E S P O K A N E • T R I -CITIES 2 2215 North 30th Street, Suite 300 Tacoma, WA 98403 1 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB N0. NOTES 1. At marked crosswalks, the connection between the curb ramp and the road- way must be contained within the width of the crosswalk markings. . Where "GRADE BREAK" is called out, the entire length of the grade break between the two adjacent surface planes shall be flush. S. Do not plane Gratings, .Junction Bones, Access Covers, or other appurten- ances on any part of the Curb Ramp or Landing, or in front of the Curb Ramp where it connects to the roadway. 4. See Contract Plans for the curb design specified. See Standard Plan F-10.12 for Curb, Curb and Gutter, Depressed Curb and Gutter. and Pedestrian Curb details. 5. See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. See Contract Plans for width and placement of sidewalk. 0. The Bid Item "Cement Concrete Curb Ramp Type does not include the adjacent Curb, Curb and Gutter. Depressed Curb and Gutter, Pedestrian Curb, or Sidewalks. 7. The Curb Ramp length is not required to exceed 15 feet (unless shown otherwise in the Contract Plans). When applying the 15-foot max- length, the running slope of the Curb Ramp is allowed to exceed 8.81'/o. Use a single constant slope from bottom of ramp to top of ramp to match into the landing over a horizontal distance of 15 feet. Do not include the abutting landing in the 15-foot max. measurement. 8. Curb Ramps and Landings shall receive a broom finish. See Standard Specifications 8-14. 9. Pedestran Curb may be omitted if the ground surface at the back of the Curb Ramp andior Landing will be at the same elevation as the Curb Ramp or Landing and there will not be material to retain. LEGEND SLOPE IN EITHER DIRECTION 1.5% OR FLATTER RECOMMENDED FOR DESIGN/FORMWORK {29A MAX.) 7.5% OR FLATTER RECOMMENDED FOR DESIGNI-FORMWORK (8.3% MAX.} 9.59% OR FLATTER RECOMMENDED FOR ik iC ' C DESIGN{FORMWORK (10% MAX.) ISOMETRIC VIEW TYPE PERPENDICULAR B PAY LIMIT ct ok 1 S T YW"' Qigltslly Sglled by fi_ Scott Zeller PERPENDICULAR CURB RAMP STANDARD PLAN F-40.1544 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Date, 2020,09.25 14 A4.37-07'00' STATE DESIGN ENGINEER CFOWashinglon Smta Doporlmanl of Transportation SURVEYED: DESIGNFI � / RI REVISED PER CITY COMMENTS DATED 04/02/24 RI 9/6/24 DRAWN: GB REVISED PER CITY COMMENTS DATED 10/25/23 JMT 2/16/24 CHEII§K/ MW REVISION BY DATE APPR APPROVED: SCALE: ONE INCH AT FULL SCALE IF NOT ONE IN SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M LXIC iI[NG ASt-'HA PAVEMENT SAWCUT (SEE !VOTE 2) RTFRIAI STREET MINIM 7" HMA (or ACP Class 0) (SEE NOTE 1), OVER 6" CRUSHED ROCK RESIDEN -RAL STREET MINIMUM 4" HMA (or ACP Clc= B) (SEE NOTE 1), OWR 6" CRUSHED ROCK NOTES- 1. MUST MATCH EXISTING THICKNESS IF GREATER 2. SAWCUT SHALL BE POSITIONED 1' -- 4" BEYOND EDGE OF DAMAGED PAVEMENT. 3, THE INTENT 0i= THIS DESICN IS TO DESCRIBE PAVEMENT PLACEMENT AT 1HE GUTTER FACE, SEE STANDARD PLAN! FOR CEMENT CONCRETE CURBS. I * PUBLIC WORKS i DEPARTMENT . o CURB AND GUTTER REPLACEMENT DETAIL. CURB AND GUTTER REPLACEMENT NOT TO SCALE • uR CITY OF RENTON Planning/Building/Public Works Dept. STD]. PLAN - 103 R-427822 IN COMPLIANCE WITH CITY OF RENTON STANDARDS MAPLE HIGHLANDS AHBL JOB #2221005.10 ROAD NOTES & DETAILS DATE: 9/6/2024 FIELDBOOK: PAGE: DRAWING NO: C3.14 SHEET: 22 OF: 39 R- C3.14 CM (C) 0 C') N 1 LJ N Q D J IH H N