WASTEWATER UrnLfTY STANDARD NOTES
1 ALL WORK AND MATERIAL SHALL -BE IN CONFORMANCE WITH THE STANDARDS AMID SPECIFICATION OF THE CITY
OF RENTON PUI:3LIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOTIAMNA STANDARDS AND
SPECIFICATIONS. AS APPROVED AND MODIFIED BY THE CITY OF RENTON STANDARD PLANS a SPECIFICATIONS
A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTI-ON
2 DATUM FOR VERTICAL CONTROL SHALL 13E NORTH AMERICAN VERTICAL DATUM 1966 HORIZONTAL CONTROL
SHALL BE NORTH AhAERICAN DATUM 14ST1991 UNLESS OTHERWISE APPROVED BY THE CITY BENCHMARKS
AND MONUMENTS SHALL BE REFERENCED ON THE APPROVED PLANS
3 A PRE -CONSTRUCTION CONFERENCE AND A 24-#-LOUD NOTICE SHALL. BE REQUIRED PRIOR TO STARTING NEW
CONSTRUCTION IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS,
INCLUDING STREET USE PERMITS, PRIOR TO STARTING CONSTRUCTION INSPECTION WILL BE ACCOMPLISHED
BY A REPRESENTATIVE OF THE CITY. IT SHALL HE THE CONTRACTOR'S RESPONSiBILITY TO NOTIFY THI• PUBLIC
WORKS INSPECTOR 24 HOURS IN ADVANCE QP BACKFILLING ALL CONSTRUCTION
4 THE HOURS CF WORK IN THE STREET RIGI-IT-OF-WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS
UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AN APPROVED TRAFFIC
CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT-OF-WAY
5 CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS. METHODS AND SEQUENCES OF CONSTRUCTION AND
FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE IN ACCORDANCE WITH LOCAL.
STATE AND FC DER&L REQUIREMENTS-
6. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S
FRESPQNSIBIL IT`r' TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID [DAMAGE OR DISTURBANCE
THE CONTRACTOR SHALL COMPLY WITH THE REOUIREMFNTS OF RGW 19 122 A DIG TICKET SHALL Sr.
OBTAINED A MINIMUM OF TWO BUSINESS DAYS PRIOR TO STARTING ANY EXCAVATION THE CONTRACTOR
SHALL HAVE A COPY OF THE DIG TICKET ON SITE AT ALL TIMES
7 BAOKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE [DEPTH
OF 12-INCHES- MAXIMUM DEPTH 18-INCHES, THOROUGHLY COMPACTING EiAQH LAYER TO 95 PERCENT OF
MAX[MUM DENSITY THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE
PIPE OFF TO THE SIDE OF THE TRENCH MATESRSALS TO COMPLETE THE FILL OVER THE PIPE SHALL BE
EQUIVALENT TO BANK RUN GRAVEL FOR TRENCH BACKFILL (9-113.19).
9 SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUI3I3ER-CASKETEDD ASTM D 3034. SDR 35.
CBCCIG905 OR DU TILF IRON CLASS 50. UNLESS OTHERWI+ISE APPROVED BY THE CITY
9 SANITARY SEWER PIPES SHALL NOT BE LOCATED UNDER ANY STRUCTURE (WALL, SUll-cmG FOUNDATION. ETC ]
UNLESS APPROVED BY THE CITY IF A SANITARY SEVER IS TO UE LOCATED UNDER ANY STRUCTURE (WALL,
BUILDING FOUNDATION, ETC ), IT SHALL BE DESIGNED BY PROFESSIONAL ENGINEER LICENSEE] 1N THE STATE
OF Wti+ASHINGTON IN ACCORDANCE WITH STANDARD DETAIL +412
10. OPEN -CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON -EXISTING TRAVELED ROADWAYS SHALL BE
BACKFILLEID WITH CRUSHED SURFACING AGGREGATE {WSDOT SPECIFICATION 9-03 9(3) okhi3 MECIHANICAi LY
COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY
11 ALL P1PE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH
THE STANDARDS AND SPECIFICA71ON OF THE CITY AND THE LATEST EDITION OF THE WSDOTAPWA STANDARDS
AND SPECIFICATION AS APPROVED AND M001FIE0 BY THE C17Y IN THE RENTON STANDARD FLANS IE
SPECIFICATIONS THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE
FOUNDATION MATERIAL TO A UNIFORM GRADE SQ THAT THE ENTIRE LENGTH OF THE PIPE WILD a SUFPCRTE1)
ON A UNIFORMLY DENSE, UNYIELDING BASE PIPE BEDDING SHALL BE IN ACCORDANCE WITH STANDARD PLAN
405
12 ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STA13IL17-ED TO THE 5ATISFACTION OF
THE CITY FOR THIE PREVENTION OF ON -SITE EROSION BOTH DURING GONSTRUCTION AND AFTER THE
COMPLETION OF CONSTRUCTION IN ACCORDANCE WITH T14E CURRENT SURFACE WATER DESIGN MANUAL
13 THE CONTRACTOR SHALL PROVIDE THI= Crry QF RENTQN W17H A RECORD DRAWING OF THE SANITARY SEW ER
SYSTEM WHICH HAS BEEN STAMPED} AND SIGNED BY A LJCENSED PROFESSIONAL ENGINEER OR LICENSED
Pll OQ ESSIONAL SURVEYOR
� STR_ PLAN - 413
PUBLIC WORKS WASTEWATER UTILITY
DEPARTMENT STANDARD NOTES Martin PastuchaO/26/
F.•-I , wu-h AdI„ r,I• •,.., DATE
WASTEWATER UTILITY STANDARD NOTES
RECESSES] Not to Scale
LIFT POCKET
FRAME
a a 3 4a. ER LETTING "SEWER" 1'-0,DIAME7ER 1P_0
IL ci p =
SEWS E:R
� � Q
10-12"
14'
12-3 4" --
. 11"
12-1 4"
CAST IRON RING ANC
h10.TE S.
1 B" AND 6" CLEAN-OU I RINGS AND COVERS ON SEWER VAINS SHALL BE EAST JORD]AN IRON WORKS, INC
No 3698 (PPODUCT NO 00369803) OR APPROVED EQUAL CLEAN QLIT SHALL BE A WA —ER TIGHT ASSEMBLE'
2 IN UNIMPROVED AREAS. POUR A B" THICK. 3'-4" SQUARE
CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER
3 INSTALL ASPHALT COLLAR PER STANDARD PLAN 106
OR
DABLE
U'R IPUBS IC WORKS 8" O R "' LEAN UT . PLAN - 403.1
DEPARTMENT FOR SANITARY SEWER MAIN Martin Pla tUCW26/2020
SEWER CLEANOUT
NOT TO SCALE \ L / NOT TO SCALE
+ �T T . j,
0 �\O OF WASjIIY�vl ■ -
0 ��� .•� ��.7i, SURVEYED: SCALE:
® �� -
Q T A C O M A S E A T T L E DESIGNJ
F�t / RI
tl
97, w� S P O K A N E T R I -CITIES 2 REVISED PER CITY COMMENTS DATED 04/02/24 RI 9/6/24 DRAWNGB
GISTERE9 l�1 REVISED PER CITY COMMENTS DATED 10 25 23 JMT 2 16 24 ONE INCH
s 2215 North 30th Street, Suite 300 Tacoma, WA 98403 / / / / CHECK AT FULL SCALE
Know what's below. sIONAL E� 253.383.2422 TEL 253.383.2572 FAx www.ahbLcom WEB K/ MW SCALE T ONE DINGLY
INCH
Call before you dig. 09/10/2024 NO. REVISION BY DATE APPR APPROVED
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
E W (SEE NOTE 7 LIMI-S OF PIPE ZONE
BEDDING MATERIAL FOR � f
SANITARY SEWER PIPF of
(SEE NOTE 5) PPE
rouNonnON LEVEL 5'
BEDDING FOR SANITARY SEWER PIPE
N OTES
L PROVIDE UNIFORM SUPPORT UNDER PARREL
2. HAND TAMP UNDER HAUNCHE5-
3, COMPACT BEDDING MATERIAL TO 95 MA)(. D£NSfTY EXCEPT DIRECTLY
OVER PIPE. HAND TAMP ONLY.
4. PIKE INSTALLATION SHALL BE PER SECTION 7-05 OF THE
STANDARD SPEDFICATIONS
5 PiPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)
OF THE STANDARD SPEOFICATIONS
6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW
LINE IS MAfNTAINED
7 TRENCH WIDTH SHALL BE PER SECTION 2--09.4 OF TI4E
STANDARD SPECIFICAPONS.
STD. PLAN - 405
.- PUBLICWORKS PIPE BEDDING APP
DEPARTMENT FOR SANITARY SEWERS Ftirl Pat11 ha1 6/202
i J tiK91 LT9H�3a43 i DATE
PIPE BEDDING FOR SANITARY SEWERS
NOT TO SCALE
•
CITY OF
RENTON
Planning/Building/Public Works Dept.
S-427807
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WASTEWATER UTILITY �'
jstowell 11 /26/2024
DEVELOPMENT ENGINEERING A _�'
IL
HHuynh 12/04/2024 %ji
MAPLE HIGHLANDS
AHBL JOB #2221005.10
SEWER STANDARD
NOTES & DETAILS
DATE:
9/6/2024
FIELDBOOK:
PAGE:
DRAWING NO:
C6.1
SHEET: 34 OF: 39
co
co
CO
O
O
co
N
AN
N
N
T
0
i
N
a
D
_J
T
O
N
N
IIr
'i1
a
C6.1