DocuSign Envelope IC: 9D9BODA8-0385-4664-AE66-57BFF1561D7F
MIN.
MIN.
LUMINAIRE POLE
JUNCTION BOX
CONCRETE PAD,
PLAN VIEW BROOM FINISH
LUMINAIRE POLE
CONCRETE PAD
m
4"
JUNCTION BOX
LUMINAIRE CONCRETE
FOUNDATION
SIDE VIEW
LUMINAIRE CONCRETE PAD DETAIL
GENERAL NOTES:
1. LUMINAIRE CONCRETE PAD SHALL BE USED IN AREAS
OUTSIDE OF SIDEWALK
2. CONCRETE CLASS FOR LUMINAIRE CONCRETE PAD SHALL
BE PER STD PLAN 135
3. TOP OF LUMINAIRE FOUNDATION ELEVATION SHALL BE
LOCATED AT BOTTOM OF LUMINAIRE CONCRETE PAD
ELEVATION OR BOTTOM OF SIDEWALK ELEVATION
4. LUMINAIRE POLE AND JUNCTION BOX TYPE PER PLAN
5. LUMINAIRE CONCRETE PAD ACCOMMODATES TYPE 1 AND
TYPE 2 JUNCTION BOXES ONLY
LUMINAIRE POLE \ L JUNCTION BOX
CONCRETE SIDEWALK
PLAN VIEW PER STD PLAN 102
LUMINAIRE POLE
CONCRETE SIDEWALK
PER STD PLAN 102
JUNCTION BOX
LUMINAIRE CONCRETE
FOUNDATION
SIDE VIEW
LUMINAIRE WITH SIDEWALK DETAIL
-0"
CONCRETE PAD
JUNC11ON BOX PLAN VIEW
4"
CONCRETE PAD
JUNCTION BOX SIDE VIEW
INDIVIDUAL JUNCTION BOX PAD DETAIL
Y LUMINAIRE CONCRETE
STD. PLAN - 120
®� PUBLIC WORKS PAD/SIDEWALK AND APPROVED:
A = DEPARTMENT JUNCTION BOX CONCRETE PAD Martin Pastucha 7/27/2022
FN tO DATE
DocuSign Envelope ID: 9D9BODA8-03854664-AE66-57BFF1561D71F
CONDUIT ENTRANCE AREA, SEE NOTE 13, STD PLAN 126.2
a ,
a
0.0
SEE STD PLAN 126.2 FOR ADDITIONAL NOTES
a
•a .
PLAN VIEW
SIZE TO FIT SIZE TO FIT
CABINET CABINET
6" 6" 1'-0" 1'-0"
-GRADE LEVEL
CV <
C4
:4 .
<•4 • a
FRONT VIEW SIDE VIEW
ELECTRICAL SERVICE CABINET FOUNDATION
SEE STD PLAN 126.2 FOR ADDITIONAL NOTES
SHIM TO PLUMB
SEE NOTE 3
o #4 HOOPS
IIT 4 BAR E�AC I CORNER
MIN 1 TO 2"
3/8" DIAMETER PLASTIC DRAIN
SIDE VIEW
CABINET DEPTH
V-6" + 2" . V-6"
r-
- - #4 BAR EACH
z + #4 CORNER
m _ _ _ �I+ _HOOPS
PLAN VIEW CONDUIT ENTRANCE AREA,
SEE NOTE 5, STD PLAN 126.2
CONTROLLER CABINET FOUNDATION
Y CABINET FOUNDATION
PUBLIC WORKS DETAILS STD. PLAN - 126.1
APPROVED:
p DEPARTMENT Martin Pastucha 7/27/2022
N S O ram......
DATE
transpogroup
WHAT TRANSPORTATION CAN BE.
12131 113TH AVENUE NE, SUITE 203 (TEL) 425 821-3665
KIRKLAND, WASHINGTON 98034 (FAX) 425 825-8434
DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F
INSTALL DECAL NUMBERS/LETTERS VERTICALLY.
DECAL NUMBERS/LETTERS, SEE NUMBERING
EXAMPLE, THIS SHEET. SHALL BE INSTALLED IN
DRY WEATHER, 50' F OR ABOVE
2
3
4
C
6
z
7 mz
0
NUMBERING EXAMPLE
�n
1-3/4" TO 2"
I-PEDESTRIAN
SCALE
CURB DECAL
TRAFFIC
FLOW
DECAL ORIENTATION
FOR POLES SHOWN ON STD PLAN 116.1
90. PEDESTRIAN SCALE
DECAL
PEDESTRIAN SCALE �ZURB
CURB DECAL
TRAFFIC TRAFFC
FLOW FLOW
DECAL ORIENTATION
FOR POLES SHOWN ON STD PLAN 117.2
TRAFFIC
FLOW
DECAL ORIENTATION
FOR POLES SHOWN ON STD PLAN 117.13117.1A
SCALE
CALE
LUMINAIRE STANDARD DECAL STD. PLAN - 121
®� PUBLIC WORKS NUMBERING SYSTEM APPROVED: 7/27/2022
A DEPARTMENT Martin Pastucha I
FN t� DATE
DocuSign Envelope ID: 9D9BODA8-03854664-AE66-57BFF1561D71F NOTES
1. WHERE FOUNDATION PAD IS LOCATED WITHIN A SIDEWALK, CONSTRUCT
PAD TOP FLUSH WITH SIDEWALK GRADE, OMITTING CHAMFER WHERE
TOP AND SIDEWALK ABUT. MOUNT TOP SHALL BE FINISHED BY A
CONCRETE CONTRACTOR AND SHALL MEET THE REQUIREMENTS OF
SECTION 8-14.3 IN THE WSDOT STANDARD SPECIFICATIONS.
2. PAD MOUNT DESIGN IS TYPICAL.
3. PLACE A SILICONE SEAL BETWEEN THE FOUNDATION AND CABINET.
4. ANCHOR BOLTS AND THEIR SPACING TO BE SUPPLIED BY CABINET
MANUFACTURER AND SUBMITTED TO THE ENGINEER FOR APPROVAL.
5. CONDUIT SIZES/QUANTITIES FOR CONTROLLER CABINETS SHALL BE
INSTALLED PER THE CONTRACT PLANS, PLUS ONE 2" SPARE CAPPED
OUT PAST THE FOUNDATION.
6. CONCRETE CLASS PER STD PLAN 135.
7 2" CONDUIT SHALL BE PLACED FROM THE ELECTRICAL SERVICE/BBS
ELECTRICAL SERMCE/BBS CABINET CABINET TO THE CONTROLLER CABINET.
B. EACH CABINET SHALL HAVE A W DIAMETER PLASTIC DRAIN PIPE.
CONTROLLER CABINET
9. LOCATE CONDUITS CENTRALLY WITHIN THE CABINETS.
10. WHEN ALL THREE CABINETS ARE TO BE INSTALLED AND SPACE
ALLOWS, A COMBINED FOUNDATION SHALL BE USED.
11. WOODEN SHIMS SHALL NOT BE USED
12. GROUNDING SHALL BE PER WSDOT STANDARD PLAN J-60.05, SHEET 3.
SHIM TO PLUMB 13. CONDUIT SIZES/QUANTITIES FOR ELECTRICAL SERVICE CABINETS SHALL
SHIM TO PLUMB BE INSTALLED PER THE CONTRACT PLANS, PLUS ONE 2" SPARE
CAPPED OUT PAST THE FOUNDATION.
SEE NOTE 3 SEE NOTE 3
4 HOOPS SHIM TO PLUMB
EQUAL SPACES) SEE NOTE 3
it III 1 �2•
111111
- i II
6" MIN 1" TO 2" J
Lj
FRONT VIEW Lj
3 - #4 REINFORCING BAR (EQUAL SPACES) 3/8" DIAMETER PLASTIC DRAIN (ONE PER CABINET)
SEE NOTE 5
SEE NOTE 7
1O 3/8" DIAMETER PLASTIC DRAIN
IAl
SEE NOTE 13
W
0
Ir
6
3 - /4 REINFORCING BAR
(EQUAL SPACES)
NU
HORIZONTAL
COMBINED FNDATION
REINF. OU
BAR DIAGRAM
6 PIECES
PLAN VIEW
COMBINED CONTROLLER/ELECTRICAL SERVICE/BBS FOUNDATION
Y CABINET FOUNDATION
DETAILS STD. PLAN - 126.2
PUBLIC WORKS
• DEPARTMENT APPROVED: a 7/27/2022
Martln"Pasiucha
DATE
OBI
DocuSign Envelope ID: F09FD439-BD224654-ABD3-E560AA1F5959
z O 0
O °
ILL
cun0000 000040
D D
N
0
z .. 0...
w
Ij ............ ................
H(D2mw
wz(30>
L Ujm
J=wW
Z - - Q U)
Enj = �- W
CO Z
< - < m
U W= Q 0
0 z 0 U
W H m a
2 J W
wElw
HZ�Z)Im-
Ofw00�
LLI-wO �
0 W ��
w=_j
-LL
10 aO
W Q W
W Q J ,�
J _W
J- Q
ZZW2
�-_ <
IYUzI~i
O mw
IQi�J2Z
DO0�
OinOz
0
DO
w
H
m m
�za(D
W Of
tnU)OZ
2zw
W Dw
w W w Lu
>
m
m
C
H
J W
W Q z J
DO Y
Q m W
0
J~za
dam
wOf - -
rn �
0 0
r� rrv-
0.0 �U)
ww z d oar
F¢ a 0 r z]Lu
a
w[D r J 0¢0
z u
0 V0:
N
N
z
J
D-
0
Of
Q
0
z
w c')
CL
O w
O
LL In
W
H
O
z
\�I
w
Or -
co
Lu
to
Q
a
w
J
CD
z
0
v
N
0
a� SERVICE CABINET T .PLAN - 122.1
PUBLIC WORKS 5B8131F
PP OVZDStUCT1�P1
A DEPARTMENT Martin I- 8/2021 14:
N tDATE
DocuSign Envelope ID: 9D9BODA8-03854664-AE66-57BFF1561D71F
GENERAL NOTES:
1. ALL EXISTING TRANSPORTATION INFRASTRUCTURE FEATURES SHALL BE MAINTAINED ON LEVEL
GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES,
LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS).
2. ALL TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED ON LEVEL GRADE ONCE
CONSTRUCTION IS COMPLETE.
3. ALL EXISTING OR PROPOSED TRANSPORTATION INFRASTRUCTURE FEATURES WITHIN THE PROJECT
CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS (I.E. JUNCTION BOXES SHALL
HAVE NON-SKID LIDS).
4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBER COMMUNICATION CONNECTION
TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK.
5. ALL TRANSPORTATION INFRASTRUCTURE FEATURES THAT ARE TO BE REMOVED AND REINSTALLED
AT A LATER DATE SHALL BE RE -INSTALLED TO CURRENT STANDARDS.
6. ALL CONDUIT SHALL BE PVC SCHEDULE 80.
7. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE.
8. ALL PROPOSED SIGNAL POLE FOUNDATIONS AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS
SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK
SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST
2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS OR UNLESS
OTHERWISE APPROVED.
9. WHEN THE TRAFFIC SIGNAL IS OPERATIONAL, VEHICLE DETECTION SHALL BE MAINTAINED AND
REMAIN FUNCTIONAL. NEW PERMANENT/TEMPORARY VIDEO DETECTION SHALL BE INSTALLED
AND OPERATIONAL PRIOR TO DESTROYING ANY EXISTING VEHICLE DETECTION.
10. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION
SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION
PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE
TRANSPORTATION OPERATIONS MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS
MAINTENANCE REPRESENTATIVE.
Y TRANSPORTATION NOTES
PUBLIC WORKS STD. PLAN - 135
APPROVED:
A DEPARTMENT Martin Pastucha 7/27/2022
FN T� DATE
31
DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1F5959
COMPONENT SCHI llULE
OMETERBASE: 200 AMP, 4 JAW, MANUAL BYPASS, B-LINE U264
W/ 5T" JAW AT 9:00 POSITION
O PANELBOARD: 120/240 VAC, 125 AMP COPPER BUS, 1 PHASE, 3 WIRE, 18 CKT, 1 OK AIC
MAIN BREAKER: 200 AMP FRAME, 200 AMP TRIP, 2 POLE, EATON ED2200
BOLT -ON BRANCH BREAKERS, EATON TYPE BAB:
2 - 20/2 ILLUMINATION A, B
1 - 20/1 ITS
1 - 20/1 GROUND FAULT RECEPTACLE
1 - 40/1 SIGNAL (IF PRESENT)
1 - 40/1 AUXILLIARY SIGNAL (IF PRESENT)
2 - 60/2 SMALL CELL BRANCH
1 - 15/1 CONTROL
3 - 20/1 SPARE
O CONTACTOR: NEMA LIGHTING RATED, 30 AMP 4 POLE, 120 VAC COIL,
SQD 891ODPA34VO2 -I REQUIRED
0 PHOTO ELECTRIC CELL: 1800 WATT, 120 VAC, TWIST LOCK, ALR #SST-IES-UL
MOUNTED INSIDE CABINET BEHIND WIREGLASS WINDOW
PHOTO -CELL BYPASS SWITCH:
0
SPDT, 15 AMP, RATED (UP TO) 277 VAC (FED THROUGH TERMINAL BLOCK)
OGROUND FAULT RECEPTACLE: 20 AMP, 125 VAC, DUPLEX
CABINET:
CONSTRUCTION:
NEMA TYPE 3R, OUTDOOR PADMOUNT, 1/8" 5052-H32 ALUMINUM CONSTRUCTION, OPEN BOTTOM
FRAMED WITH 2" ANGLE, 2 SCREENED AND GASKETED VENTS, REMOVABLE EQUIPMENT
MOUNTING PAN, CABINET GROUND WITH MINIMUM BONDING WIRE TO NEUTRAL
DOORS: HEAVY-DUTY CONCEALED HINGES (LIFT-OFF TYPE),STAINLESS STEEL VAULT HANDLES WITH
ROLLER RODS THAT PROVIDE 3-POINT COMPRESSION ON CLOSED CELL NEOPRENE GASKET,
"BEST" LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER,
PADLOCKABLE UPPER METER DOOR WITH POLISHED SAFETY GLASS WINDOW
DEADFRONT: HINGED AND SECURED WITH QUARTER -TURN FASTENERS
FINISH: MILL FINISH ALUMINUM
1 - REQUIRED
UL LISTED PER STANDARD #508A
"SUITABLE FOR USE AS SERVICE ENTRANCE"
NOTE:
1. SIGNAL BREAKER(S) SHALL BE ADDED WHEN APPLICABLE
SERVICE CABINET NOTES ��pp RRT PLAN - 122.2
®� DEPARTMENTPUBLIC WORKS MaPrti�n a$tUC�l�i'8/2021 I 4;
FN C� DATE
3:
T-427808
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TRANSPORTATION OPERATION
CBarnes 12/09/2024 '
SURVEYED:
SCALE:
AS NOTED
VERTICAL* VD
HORIZONTAL: NAADD 1983/1991
DATUM
- -
C T Y O F
f;RRENTON
•
Planning/Building/Public Works Dept.
MAPLE HIGHLANDS
ILLUMINATION DETAILS
DATE:
9/4/2024
DESIGNED: TK
FIELDBOOK:
PAGE:
DRAWN: TK
ONE INCH
DRAWING N0:
IL.3
CHECKED: CAC
l•
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
N 0 .
REVISION
BY
DATE
AP P R
APPROVED:
CAC
SHEET: OF:
55 55
�1
L_J