HomeMy WebLinkAboutT-42780800 N N Iq O U) 0 z a 2 2 W J n Q N 0 N 1-1 - Q) E \ Q) v 0 0 N N / cn (1) V) c v n 0 U Q) Q) C w c 0 c Q) DocuSign Envelope IC: 9D9BODA8-0385-4664-AE66-57BFF1561D7F MIN. MIN. LUMINAIRE POLE JUNCTION BOX CONCRETE PAD, PLAN VIEW BROOM FINISH LUMINAIRE POLE CONCRETE PAD m 4" JUNCTION BOX LUMINAIRE CONCRETE FOUNDATION SIDE VIEW LUMINAIRE CONCRETE PAD DETAIL GENERAL NOTES: 1. LUMINAIRE CONCRETE PAD SHALL BE USED IN AREAS OUTSIDE OF SIDEWALK 2. CONCRETE CLASS FOR LUMINAIRE CONCRETE PAD SHALL BE PER STD PLAN 135 3. TOP OF LUMINAIRE FOUNDATION ELEVATION SHALL BE LOCATED AT BOTTOM OF LUMINAIRE CONCRETE PAD ELEVATION OR BOTTOM OF SIDEWALK ELEVATION 4. LUMINAIRE POLE AND JUNCTION BOX TYPE PER PLAN 5. LUMINAIRE CONCRETE PAD ACCOMMODATES TYPE 1 AND TYPE 2 JUNCTION BOXES ONLY LUMINAIRE POLE \ L JUNCTION BOX CONCRETE SIDEWALK PLAN VIEW PER STD PLAN 102 LUMINAIRE POLE CONCRETE SIDEWALK PER STD PLAN 102 JUNCTION BOX LUMINAIRE CONCRETE FOUNDATION SIDE VIEW LUMINAIRE WITH SIDEWALK DETAIL -0" CONCRETE PAD JUNC11ON BOX PLAN VIEW 4" CONCRETE PAD JUNCTION BOX SIDE VIEW INDIVIDUAL JUNCTION BOX PAD DETAIL Y LUMINAIRE CONCRETE STD. PLAN - 120 ®� PUBLIC WORKS PAD/SIDEWALK AND APPROVED: A = DEPARTMENT JUNCTION BOX CONCRETE PAD Martin Pastucha 7/27/2022 FN tO DATE DocuSign Envelope ID: 9D9BODA8-03854664-AE66-57BFF1561D71F CONDUIT ENTRANCE AREA, SEE NOTE 13, STD PLAN 126.2 a , a 0.0 SEE STD PLAN 126.2 FOR ADDITIONAL NOTES a •a . PLAN VIEW SIZE TO FIT SIZE TO FIT CABINET CABINET 6" 6" 1'-0" 1'-0" -GRADE LEVEL CV < C4 :4 . <•4 • a FRONT VIEW SIDE VIEW ELECTRICAL SERVICE CABINET FOUNDATION SEE STD PLAN 126.2 FOR ADDITIONAL NOTES SHIM TO PLUMB SEE NOTE 3 o #4 HOOPS IIT 4 BAR E�AC I CORNER MIN 1 TO 2" 3/8" DIAMETER PLASTIC DRAIN SIDE VIEW CABINET DEPTH V-6" + 2" . V-6" r- - - #4 BAR EACH z + #4 CORNER m _ _ _ �I+ _HOOPS PLAN VIEW CONDUIT ENTRANCE AREA, SEE NOTE 5, STD PLAN 126.2 CONTROLLER CABINET FOUNDATION Y CABINET FOUNDATION PUBLIC WORKS DETAILS STD. PLAN - 126.1 APPROVED: p DEPARTMENT Martin Pastucha 7/27/2022 N S O ram...... DATE transpogroup WHAT TRANSPORTATION CAN BE. 12131 113TH AVENUE NE, SUITE 203 (TEL) 425 821-3665 KIRKLAND, WASHINGTON 98034 (FAX) 425 825-8434 DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F INSTALL DECAL NUMBERS/LETTERS VERTICALLY. DECAL NUMBERS/LETTERS, SEE NUMBERING EXAMPLE, THIS SHEET. SHALL BE INSTALLED IN DRY WEATHER, 50' F OR ABOVE 2 3 4 C 6 z 7 mz 0 NUMBERING EXAMPLE �n 1-3/4" TO 2" I-PEDESTRIAN SCALE CURB DECAL TRAFFIC FLOW DECAL ORIENTATION FOR POLES SHOWN ON STD PLAN 116.1 90. PEDESTRIAN SCALE DECAL PEDESTRIAN SCALE �ZURB CURB DECAL TRAFFIC TRAFFC FLOW FLOW DECAL ORIENTATION FOR POLES SHOWN ON STD PLAN 117.2 TRAFFIC FLOW DECAL ORIENTATION FOR POLES SHOWN ON STD PLAN 117.13117.1A SCALE CALE LUMINAIRE STANDARD DECAL STD. PLAN - 121 ®� PUBLIC WORKS NUMBERING SYSTEM APPROVED: 7/27/2022 A DEPARTMENT Martin Pastucha I FN t� DATE DocuSign Envelope ID: 9D9BODA8-03854664-AE66-57BFF1561D71F NOTES 1. WHERE FOUNDATION PAD IS LOCATED WITHIN A SIDEWALK, CONSTRUCT PAD TOP FLUSH WITH SIDEWALK GRADE, OMITTING CHAMFER WHERE TOP AND SIDEWALK ABUT. MOUNT TOP SHALL BE FINISHED BY A CONCRETE CONTRACTOR AND SHALL MEET THE REQUIREMENTS OF SECTION 8-14.3 IN THE WSDOT STANDARD SPECIFICATIONS. 2. PAD MOUNT DESIGN IS TYPICAL. 3. PLACE A SILICONE SEAL BETWEEN THE FOUNDATION AND CABINET. 4. ANCHOR BOLTS AND THEIR SPACING TO BE SUPPLIED BY CABINET MANUFACTURER AND SUBMITTED TO THE ENGINEER FOR APPROVAL. 5. CONDUIT SIZES/QUANTITIES FOR CONTROLLER CABINETS SHALL BE INSTALLED PER THE CONTRACT PLANS, PLUS ONE 2" SPARE CAPPED OUT PAST THE FOUNDATION. 6. CONCRETE CLASS PER STD PLAN 135. 7 2" CONDUIT SHALL BE PLACED FROM THE ELECTRICAL SERVICE/BBS ELECTRICAL SERMCE/BBS CABINET CABINET TO THE CONTROLLER CABINET. B. EACH CABINET SHALL HAVE A W DIAMETER PLASTIC DRAIN PIPE. CONTROLLER CABINET 9. LOCATE CONDUITS CENTRALLY WITHIN THE CABINETS. 10. WHEN ALL THREE CABINETS ARE TO BE INSTALLED AND SPACE ALLOWS, A COMBINED FOUNDATION SHALL BE USED. 11. WOODEN SHIMS SHALL NOT BE USED 12. GROUNDING SHALL BE PER WSDOT STANDARD PLAN J-60.05, SHEET 3. SHIM TO PLUMB 13. CONDUIT SIZES/QUANTITIES FOR ELECTRICAL SERVICE CABINETS SHALL SHIM TO PLUMB BE INSTALLED PER THE CONTRACT PLANS, PLUS ONE 2" SPARE CAPPED OUT PAST THE FOUNDATION. SEE NOTE 3 SEE NOTE 3 4 HOOPS SHIM TO PLUMB EQUAL SPACES) SEE NOTE 3 it III 1 �2• 111111 - i II 6" MIN 1" TO 2" J Lj FRONT VIEW Lj 3 - #4 REINFORCING BAR (EQUAL SPACES) 3/8" DIAMETER PLASTIC DRAIN (ONE PER CABINET) SEE NOTE 5 SEE NOTE 7 1O 3/8" DIAMETER PLASTIC DRAIN IAl SEE NOTE 13 W 0 Ir 6 3 - /4 REINFORCING BAR (EQUAL SPACES) NU HORIZONTAL COMBINED FNDATION REINF. OU BAR DIAGRAM 6 PIECES PLAN VIEW COMBINED CONTROLLER/ELECTRICAL SERVICE/BBS FOUNDATION Y CABINET FOUNDATION DETAILS STD. PLAN - 126.2 PUBLIC WORKS • DEPARTMENT APPROVED: a 7/27/2022 Martln"Pasiucha DATE OBI DocuSign Envelope ID: F09FD439-BD224654-ABD3-E560AA1F5959 z O 0 O ° ILL cun0000 000040 D D N 0 z .. 0... w Ij ............ ................ H(D2mw wz(30> L Ujm J=wW Z - - Q U) Enj = �- W CO Z < - < m U W= Q 0 0 z 0 U W H m a 2 J W wElw HZ�Z)Im- Ofw00� LLI-wO � 0 W �� w=_j -LL 10 aO W Q W W Q J ,� J _W J- Q ZZW2 �-_ < IYUzI~i O mw IQi�J2Z DO0� OinOz 0 DO w H m m �za(D W Of tnU)OZ 2zw W Dw w W w Lu > m m C H J W W Q z J DO Y Q m W 0 J~za dam wOf - - rn � 0 0 r� rrv- 0.0 �U) ww z d oar F¢ a 0 r z]Lu a w[D r J 0¢0 z u 0 V0: N N z J D- 0 Of Q 0 z w c') CL O w O LL In W H O z \�I w Or - co Lu to Q a w J CD z 0 v N 0 a� SERVICE CABINET T .PLAN - 122.1 PUBLIC WORKS 5B8131F PP OVZDStUCT1�P1 A DEPARTMENT Martin I- 8/2021 14: N tDATE DocuSign Envelope ID: 9D9BODA8-03854664-AE66-57BFF1561D71F GENERAL NOTES: 1. ALL EXISTING TRANSPORTATION INFRASTRUCTURE FEATURES SHALL BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 2. ALL TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 3. ALL EXISTING OR PROPOSED TRANSPORTATION INFRASTRUCTURE FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBER COMMUNICATION CONNECTION TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK. 5. ALL TRANSPORTATION INFRASTRUCTURE FEATURES THAT ARE TO BE REMOVED AND REINSTALLED AT A LATER DATE SHALL BE RE -INSTALLED TO CURRENT STANDARDS. 6. ALL CONDUIT SHALL BE PVC SCHEDULE 80. 7. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 8. ALL PROPOSED SIGNAL POLE FOUNDATIONS AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST 2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS OR UNLESS OTHERWISE APPROVED. 9. WHEN THE TRAFFIC SIGNAL IS OPERATIONAL, VEHICLE DETECTION SHALL BE MAINTAINED AND REMAIN FUNCTIONAL. NEW PERMANENT/TEMPORARY VIDEO DETECTION SHALL BE INSTALLED AND OPERATIONAL PRIOR TO DESTROYING ANY EXISTING VEHICLE DETECTION. 10. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION OPERATIONS MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS MAINTENANCE REPRESENTATIVE. Y TRANSPORTATION NOTES PUBLIC WORKS STD. PLAN - 135 APPROVED: A DEPARTMENT Martin Pastucha 7/27/2022 FN T� DATE 31 DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1F5959 COMPONENT SCHI llULE OMETERBASE: 200 AMP, 4 JAW, MANUAL BYPASS, B-LINE U264 W/ 5T" JAW AT 9:00 POSITION O PANELBOARD: 120/240 VAC, 125 AMP COPPER BUS, 1 PHASE, 3 WIRE, 18 CKT, 1 OK AIC MAIN BREAKER: 200 AMP FRAME, 200 AMP TRIP, 2 POLE, EATON ED2200 BOLT -ON BRANCH BREAKERS, EATON TYPE BAB: 2 - 20/2 ILLUMINATION A, B 1 - 20/1 ITS 1 - 20/1 GROUND FAULT RECEPTACLE 1 - 40/1 SIGNAL (IF PRESENT) 1 - 40/1 AUXILLIARY SIGNAL (IF PRESENT) 2 - 60/2 SMALL CELL BRANCH 1 - 15/1 CONTROL 3 - 20/1 SPARE O CONTACTOR: NEMA LIGHTING RATED, 30 AMP 4 POLE, 120 VAC COIL, SQD 891ODPA34VO2 -I REQUIRED 0 PHOTO ELECTRIC CELL: 1800 WATT, 120 VAC, TWIST LOCK, ALR #SST-IES-UL MOUNTED INSIDE CABINET BEHIND WIREGLASS WINDOW PHOTO -CELL BYPASS SWITCH: 0 SPDT, 15 AMP, RATED (UP TO) 277 VAC (FED THROUGH TERMINAL BLOCK) OGROUND FAULT RECEPTACLE: 20 AMP, 125 VAC, DUPLEX CABINET: CONSTRUCTION: NEMA TYPE 3R, OUTDOOR PADMOUNT, 1/8" 5052-H32 ALUMINUM CONSTRUCTION, OPEN BOTTOM FRAMED WITH 2" ANGLE, 2 SCREENED AND GASKETED VENTS, REMOVABLE EQUIPMENT MOUNTING PAN, CABINET GROUND WITH MINIMUM BONDING WIRE TO NEUTRAL DOORS: HEAVY-DUTY CONCEALED HINGES (LIFT-OFF TYPE),STAINLESS STEEL VAULT HANDLES WITH ROLLER RODS THAT PROVIDE 3-POINT COMPRESSION ON CLOSED CELL NEOPRENE GASKET, "BEST" LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER, PADLOCKABLE UPPER METER DOOR WITH POLISHED SAFETY GLASS WINDOW DEADFRONT: HINGED AND SECURED WITH QUARTER -TURN FASTENERS FINISH: MILL FINISH ALUMINUM 1 - REQUIRED UL LISTED PER STANDARD #508A "SUITABLE FOR USE AS SERVICE ENTRANCE" NOTE: 1. SIGNAL BREAKER(S) SHALL BE ADDED WHEN APPLICABLE SERVICE CABINET NOTES ��pp RRT PLAN - 122.2 ®� DEPARTMENTPUBLIC WORKS MaPrti�n a$tUC�l�i'8/2021 I 4; FN C� DATE 3: T-427808 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TRANSPORTATION OPERATION CBarnes 12/09/2024 ' SURVEYED: SCALE: AS NOTED VERTICAL* VD HORIZONTAL: NAADD 1983/1991 DATUM - - C T Y O F f;RRENTON • Planning/Building/Public Works Dept. MAPLE HIGHLANDS ILLUMINATION DETAILS DATE: 9/4/2024 DESIGNED: TK FIELDBOOK: PAGE: DRAWN: TK ONE INCH DRAWING N0: IL.3 CHECKED: CAC l• AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY N 0 . REVISION BY DATE AP P R APPROVED: CAC SHEET: OF: 55 55 �1 L_J