HomeMy WebLinkAboutW-381201SEC.19 T.23N. R.5E. W.M. GENERAL NOTES: WTM N i CUT AND CAP EXISTING 4" WATER 14ST STA 10+89.52 (25.76 LT) / I / OPL LINE CONNECTION BY OTHERS — 14ST 9+92.44 POB = o G / NB405 1190+64.33, 345.03' RT N 173399.33 0 E 1298516.47 (SEE SHEETS PVD01-PVD04) • o / x /10. / 21 o X' APPROXIMATE'LOCATION OF EX. WATER METER. FIELD VEA[FFy_:._._., i EX 4" W TO BE; CUT AND CAPPED 10' \ WSDOT LIMITED NORTH OF EXISTI ATER SERVICE RIGHT, OF WAY �� LINE. THIS WORD O BE PERFORMED Y OPL AND THE CI OF RENTON. 9 i 6 y 0 / EX FIRE HYDRANT 22t ASSEMBLY TO REM IN 8 DI WATER MAIN CONSTRUCTION SEQUENCE: 1. PRIOR TO OPL'S INSTALLATION OF THE NEW PETROLEUM PIPELINE, THE CITY AND OPL TO CUT AND CAP, AND INSTALL CONCRETE DEAD -MAN BLOCK ON EXISTING 4" WATER MAIN. 2. CITY OF RENTON TO INSTALL: a. ISOLATION VALVE, CAP AND TEMPORARY BLOCK IN DAVIS AVENUE S. b. ISOLATION VALVE, CAP AND TEMPORARY BLOCK IN SHATTUCK AVENUE S. c. ISOLATION VALVE, TEE FOR FIRE HYDRANT ASSEMBLY, ONE LENGTH OF PIPE, CAP AND TEMPORARY BLOCKING IN WHITWORTH AVENUE. d. ISOLATION VALVE, CAP AND TEMPORARY BLOCK IN MORRIS AVENUE. 3. CONTRACTOR TO ASSIST THE CITY OF RENTON TO INSTALL: a. VALVING, FIRE HYDRANT ASSEMBLY AND PERMANENT BLOCK IN SMITHERS AVENUE. 4. OPL TO REMOVE AND ABANDON OLD OIL PIPELINE. 5. OPL TO INSTALL NEW PIPELINE. 6. CONTRACTOR TO COMPLETE GRADING, CONSTRUCTION OF THE NOISE WALL AND OTHER FEATURES IN S 14TH STREET INCLUDING STORM DRAINAGE. 7. CONTRACTOR TO INSTALL AND TEST THE REMAINDER OF THE WATER MAINS AS SHOWN IN THE PLANS IN CONJUNCTION WITH CITY OF RENTON STANDARDS. NOISE WALL S —S— PROPOSED SANITARY SEWER BY OTHERS 226 EX 4" W (TO BE ABANDONED OR REMOVED AS NEEDED) PROPOSED 20" OPL BY OTHERS RIG1d OF WAY I ATKjNSoN Rf(fgSFOMRR 141017 Rjpl AS -BUILT �R�ONSTqUC170N FILE NAME c:\pwworking\nai\_x_grimando\d0321992\C8811_DE_UTD01.dgn TIME 9:02:18 AM REGION O. STATE FED.AID PROJ.NO. DATE 3/14/2017 10 WAS PLOTTED BY GRimando DESIGNED BY B. HELSLEY JOB NUMBER ENTERED BY G. RIMANDO REV 0 - RELEASED FOR CONSTRUCTION M14/17 CHECKED BY S. MESIC REV B -FINAL REVIEW 17/22/16 CONTRACT NO. C8811 LOCATION NO. PROJ. ENGR. C. CHEN I REV A -PRELIMINARY REVIEW 1 11/21/16 REGIONAL ADM. L. ENG I REVISION I DATE BY 7 DATE Box 0 0 F- w w w 2 w w 0 v DO v w z x 0 0 25 50 SCALE IN FEET AIIIIIIIIIIIIII -- Washington State Department of Transportation 1. ALL CONNECTIONS TO EXISTING WATER MAINS TO BE PERFORMED BY CITY FORCES. COORDINATE WITH CITY FOR SCHEDULING AND REQUIRED CONTRACTOR SUPPORT. 2. CONSTRUCTION SHALL BE IN ACCORDANCE WITH UTB 1221. 3. SUBGRADE FOR THE ROADWAY PRISM SHALL BE ESTABLISHED BEFORE EXCAVATION FOR INSTALLATION OF NEW WATER LINES. 4. DEPTH OF COVER OVER NEW WATER MAIN SHALL BE Y MINIMUM AND 5' MAXIMUM. 5. MINIMUM HORIZONTAL CLEARANCE TO STORM AND SHALLOW SEWER IS 5'. LEGEND T BLOW OFF ASSEMBLY CAP lcf FIRE HYDRANT CONCRETE THRUST BLOCKING BENDS SLEEVE = ADAPTOR ® WATER VALVE ® EXISTING WATER METER EXISTING WATER VALVE ® PROPOSED SANITARY SEWER MANHOLE ST PROPOSED STORM - PROPOSED DITCH ❑ PROPOSED CB UD - PROPOSED UNDERDRAIN — S S — - PROPOSED SEWER LINE w w - - PROPOSED WATER LINE — O O — - PROPOSED OIL L!^IE PLAN REF NO 1-405 / SR 167 INTERCHANGE UTD01 DIRECT CONNECTOR SHEET 244 OF UTILITY DETAIL 887 S.14TH STREET WATER SHEETS