Loading...
HomeMy WebLinkAboutW-381209N TM W 1� i N 1♦ i 30 20 Q 0 INSTALL 12" EX 16" W GATE VALVE AND (TO BE ABANDONED) 2" AIR AND VACUUM DEAD MAN BLOCK RELEASE ASSEMBLY ON EX. 12" WATER 48" SD 1 PER CITY OR RENTON STANDARD PLAN 340.4 EX. 12" W (TYP) (TO BE FUTURE CULVERT ABANDONED) EXTENSION, ORIGINAL GROUND SEE NOTE 1. EAST VALLEY ROAD ---- -- -- ------------------ - "'--______ INSTALL 12" GATE VALVE AND EX.12" W EX. 2" DEAD MAN BLOCK (TO- ON EX. 12" WATER ABANDONED) 956' ;9.5' IE=13.79 IE=11.64 E=1 .75 CONNECT TO PROPOSED 16" DI W IE=7.70± \ 1.5' MIN. 5° VERTIC L ENDS (R ) 22.5° VERTICAL 12" RJ DI W IE=4.23 BENDS (RJ) IE=3.73, CASING END SEAL (RUBBER BOOTS) TYP. CASING TO BE INSTALLED PER 42 LF CITY OF RENTON STANDARD 24" STEEL CASIN PLAN 300.7 "CASING INSTALLATION" (TYP) FILE NAME c:\pwworking\r TIME 1:19:23 PM DATE 7/612018 PLOTTED BY JZigweid DESIGNED BY G. RIMANDO ENTERED BY G. RIMANDO CHECKED BY B.HELSLEY PROJ. ENGR. C. CHEN REGIONAL ADM. L. ENG NOTE: 1. FUTURE CULVERT EXTENSION AS SHOWN WILL REQUIRE RECONSTRUCTION OF EAST VALLEY ROADANVERT SHOWN APPROXIMATE MIN. 3/4" GALVANIZED THREADED ROD COUPLING 3/4" GALVANIZED THREADED ROD SIZE AND NUMBER PER CITY OF RENTON STD. PLAN 330.5. 30 GATE VALVE- ------------------ -- - - - - - - - - - - - - - - - - - STAR JOINT RESTRAINT SYS OR APPROVED EQUAL SEE THREADED ROD ANCHORING DETAIL. V-6" D 2-6" MIN - 16" DIA. PIPE o II' --- \----� SEE STD PLAN 330.4 ------------ - - - -�" o A FOR MAXIMUM TRENCH - ------ - - - - - - - -�--. ----- WIDTH DIMENSIONS � o 11 II II EXISTING WATER MAIN_ CONCRETE DEADMAN BLOCK. 10 -i SEE CITY OF RENTON STD PLAN 330.4 NOTES: 1. PIPELINE CONTRACTOR TO INSTALL CONCRETE DEADMAN ANCHOR BLOCKS (CITY STD PLAN 330.4). 20 2. CONTRACTOR WILL EXCAVATE AROUND WATERMAIN TO ALLOW CITY OF RENTON ACCESS TO CUT IN GATE VALVE. 3. AFTER CONCRETE ANCHOR BLOCKS HAVE CURED FOR 5 DAYS MINIMUM CITY OF RENTON WILL CUT WATERMAIN AND INSTALL GATE VALVE. PIPELINE CONTRACTORS WILL SUPPLY PIPE MATERIALS. 4. PIPELINE CONTRACTORS WILL BACKFILL PIPELINE AND PERFORM PAVEMENT RESTORATION WHERE REQUIRED. 5. BACKFILL ALL AROUND PIPE AND DEADMAN BLOCK AND PIPE ZONE BEDDING SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER ASTM D1557. 6. PAVEMENT RESTORATION SHALL BE CITY OF RENTON DETAIL H032.1 "TYPICAL TRANSVERSE PATCH AND OVERLAY FOR FLEXIBLE PAVEMENT". 7. INSTALL SHACKLE RODS AND TIE BOLTS PER CITY OF RENTON STD. PLAN 330.5. 10 0 2.5 5 VERT. SCALE IN FEET 12" DIAMETER PIPE 0 25 50 D HORIZ. SCALE IN FEET �{ ATKI�S16p� � D321992\C8811_DE_UTD07.dgn REGION STATE FED.AID PROJ.NO. NO. REV 1 - RF10286 06/28/18 10 WASH REV 0 -RFC 07/20/17 JOB NUMBER REV C - FINAL REVIEW 07/10/17 REV B - PRELIMINARY REVIEW 04/04/17 CONTRACT NO. LOCATION NO. REV A -PRELIMINARY REVIEW 10/26/16 C8811 REVISION DATE BY JUL 0 9 2018 STAR JOINT RESTRA SYSTEM OR APPRO% EQUAL (TYP) 16" DIAMETER PIPE 3/4" GALVANIZED THREADED ROD TO BE INSTALLED IN DEADMAN BLOCK. (4 RODS REQUIRED) (8 RODS REQUIRED) 12" PIPE 16" PIPE THREADED ROD ANCHORING DETAIL NOTE: 1. VERIFY THE DIMENSIONS SHOWN HERE WITH THE PROPSED WATER MAIN AND FITTINGS PRIOR TO CONSTRUCTION. DIMENSIONS SHOWN ARE APPROXIMATE RELEASED FOR CONSTRUCTION AND BASED ON THE BEST INFORMATION AVAILABLE. �► N, vrxv Washington State Cis'eFR�° Department of Transportation DATE BOX STAR JOINT RESTRAINT SYSTEM OR APPROVED EQUAL (TYP) 3/4" GALVANIZED THREADED ROD TO BE INSTALLED IN DEADMAN BLOCK. S-ILT W-381209 PLAN REF NO 1-405 / SR 167 INTERCHANGE UTD07 DIRECT CONNECTOR SHEET 252 OF WATER DETAIL PLAN 887 12" WATER MAIN RELOCATION PROFILE SHEETS