HomeMy WebLinkAboutLUA-96-077 Large FormatNEW GPS ANTENNA NEW ANTENNA ARRAY POLE MNTD. ON HANDRAIL AZIMUTH = 30 DEGREES C� 3 v CL � I I N.E. ELEVATION x w Z � K w a 0 cc a x 15'- 0" EXIST. LADDER -*/CAGE EXIST. BALCONY 3'-0" MIN. SPACING (TYP) � SEE DTL. FOR (2) NEW ANTENNAS (OUTBOARD)<802 POLE MOUNTED ON HANDRAIL 660" MAX. SIZE / AZIMUTH = 30 DEGREES (2) FUTURE ANTENNAS (INBOARD) Of-�LEXIST. ROOF MANHOLE EXIST. ROOF VE�T Icy/ �A\SEE DTL. FOR 561 NEW GPS ANTENNA sIM. ATTACH TO EXIT. HANDRAIL ' T \�. co x 0 , 0 0 i o 0 I I A r I r A x A r A O SEE DTL. FOR 335 (4) NEW BOLLARDS - SEE DTL. FOR 370 360 CONCRETE SLAB of NEW LA DSCAPING ON SEE DTL. FOR ao TWO SIDS FOR SCREENING >SIM CABINET MOUNTING. SKID FOR NEW BTS EQUIPMENT x I PLAN TA $IM&T NORTH V A i I 1 -1. Am EXIST. OVERFLOW PIPE SEE DTL FOR 1 (2) NEW ANTENNAS (OUTBOARD) POLE MOUNTED ON HANDRAIL 6x6O" MAX. SIZE AZIMUTH = 120 DEGREES (2) FUTURE ANTENNAS (INBOARD) 3'-O" MIN. SPACING (TYP.) MINIMA OAX CRITERIA COAX. D-A MIN. BEND . CONDUIT SIZE MAX. LENGTH 1 5/8', 20"R 2 1 /2" DIA. 200' 1 1/4" 15" 2" DIA. 100' 7/8" 0"R 1 1 /2" DIA. 50' w}.O .� Uj o V j 00 a LL > z O > 0 z Q o Z � 0 z z w Q � 0 w o t- X W � oZ� H- O u) cc 0 z w 1 � � z Cj) z~ 0 z U war- N a. oC U M 6/20/96 ZONING REVISION 6/14/96 ZONING SET REV DATE DESCRIPTION PROJECT MANAGER JM ARCHITECT/ ENGINEER J L A DRANK BY R `A 1�1�H DATE 14 96 CHECKED BY JM DATE THESE DRANINGS AS INSTRUMENTS OF SERACE ARE THE PROPERTY OF RUHL—PARR & ASSOCIATES, INC. Architects Planners A Profound S.rvroe CaWation 3625 132nd Ave. S.E Suite 100 B«lewo, WA MW IM (205) 644-4000 SP9IN7 SPECL911W SEA TILE ENGINEERING & OPERATIONS 11000 NE 33RD PLACE - SUITE 200 BELLEKJE, WASHINGTON 98004 (206) 602-23J0 ZONING/PERMIT REG'�!\/lF RENT-007-01 MAY VALLEY JUN 2 4 1996 CITY OF RENTON/HIGHLANDS 3410 NE 12TH STREET DEVELOPN-6 r-u+NNING RENTON, WASHINGTON CITY OFRF_NTON 98056 DRAMING TITLE DRANING NO PLAN ELEVATION A 1 963a1 14:40 20 Jun 1996 JOB NUMBER „- PRINT DATE 96-963 Cu - 56-0-1`-7 (1) sF Y (1) ST Y I 1 I \ (1ORY L o: uj I (1 ST (1) ST Y I ( 1 SIF L — — Z-GRA Y SS 7 I I (1) ST I (1) ST SF SF — — — 15'—O" 151—on SIDE SETBACK SIDE SETBACK 40 L EXIST. RESERVOIR (1) STOZY I UNDER GRASS (1) STORY SIF EXIST. WATER TANK I SF (1) STORY I NEW ANTENNAS SF I i I (1) DORY 1 •" EXIST. RESERVOIR L — UNDER GRASS BALCONY PLAVORM ACCESS I I (1) SSFTORY GRAVEL DRIVE x U I� BTS EQU ENT (1) STORY t5'-0 ON C EXIST. BLD o (1) STORY SF .IF I GO SITE ACCESS NE. E i .t —, — —T — 1— Hyl I(1) (1) STORY I I (1) StoRY (2 ST Y I SIF SF SIF ( i (1) Fs.TORY SITE PLAN NORTH 1 1"=80'-0" GENERAL NOTES 1. ADA COMPLIANCE: FACILITY IS NOT STAFFED AND NOT NORMALLY OCCUPIED. 2. NO PARKING SPACES REQUIRED. 3. ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE NTH ALL APPLICABLE CODES AND ORDINANCES. 4. FIELD VERIFY ALL DIMENSIONS PRIOR TO ORDERING AND BEGINNING CONSTRUCTION. 5. FOR SPECIFICATIONS SEE ACCOMPANYING DOCUMENT "TECHNICAL SPECIFICATIONS" 6. ANTENNA ROUTING IS SCHEMATIC. CONTRACTOR TO DETERMINE SIMPLEST ROUTING. 7. ALL ANTENNA PIPE MASTS AND HARDWARE SHALL BE GALVANIZED. 8. PAINT ANTENNAS, PIPE MASTS, EXPOSED CABLES, AND HARDWARE WITH AN APPROVED PAINT COLOR. 9. SUPPORT STRUCTURE, MECHANICAL, AND ELECTRICAL SYSTEMS SHALL BE DESIGNED FOR EACH INSTALLATION SITE IN COMPLIANCE WITH 1994 UBC AND ALL LOCALLY APPLICABLE CODES, WHICHEVER IS MOST RESTRICTIVE. 10. AT STEEL FRAMES REMOVE ALL BURRS AND BREAK ALL AT STEEL SHARP EDGES. 11. PRIOR TO PLACING ANY AND ALL FREE—STANDING EQUIPMENT, CABLE TRAYS, CABLE SUPPORTS, ETC. ON THE ROOF, REMOVE EXISTING ROOF BALLAST AS NEEDED AND REQ. DO NOT PENETRATE EXISTING ROOFING MATERIAL. SPREAD NEW BALLAST TO MATCH EXISTING AFTER INSTALLATION. ROOFING, WHERE DISTURBED, SHALL BE RESTORED IN SUCH A MANNER AS TO MAINTAIN THE MANUFACTURER'S WARRANTY. ` I I 11 1 ,1 1 RESIDENTIAL i SITE DO -0 0 \ o � 0 I Fil -- - I � I ES18fNTt 1 — — in 1 a — to Q1 1 -1 NUMBERS ON IBUILDING — — INDICATE THE El u I a a I a � I NUMBER OF STORIES 010 ILI p I I' I — ZRIESIDENTIAL—Ll— — I —ZREiIDENirAL VICINITY INFORMATION T 1"=200'—O" — SITE NOTES 1. TOTAL SQUARE FOOTAGE OF SITE = 204396 S.F. 2. CONCEPTUAL DRAINAGE REPORT NOT REQUIRED 3. TREE CUTTING/LAND CLEARING PLAN NOT REQUIRED x Lx T 11 I x - —x LANDSCAPING PLAN 1" = 10'-0" NOTES: EXCAVATE TRENCH FOR HEDGING ROOTBALL 2' WIDE, 2' DEEP. REMOVE EXCAVATED SOIL FROM SITE, PROVIDE 3 WAY SOIL BACKFILL. PROVIDE (1) 2x2 STAKE PER TREE. PROVIDE 3" HT. WATERING SAUCER AT EACH SIDE OF TRENCH. PROVIDE 2" DEPTH FINE GROUND BARK TO ALL DISTURBED AREAS. (11) THUJA PYRAMIDAUS _ 'EMERALD GREEN' 6-7' B/B EVENLY SPACED -x x _x . �1 1 1 I 1 11 1 1 1 1 1 1 I N TH ImtI1 I e'u APPROVALS SIGNATURES OF INVOLVED PARTIES INDICATE THAT THEY HAVE REVIEWED THE ACCOMPANYING DOCUMENTS AND HAVE APPROVED THEM. CHANGES INITIATED AFTER APPROVALS HAVE BEEN GIVEN MAY RESULT IN ADDITIONAL DESIGN AND OR CONSTRUCTION COSTS. VCI SPRINT SPECTRUM PROPERTY CONTACT LAKE WASHINGTON VICINITY MAP N. T. S. DATE: DATE: DATE: OWNER: CITY OF RENTON, HIGHLANDS RON OLSEN - DIRECTOR 3410 NE 12TH STREET RENTON, WA. 98056 (206) 277-6207 CONTACT: ZONING APPLICATION DENNIS SCHOLL VCI 4040 LAKE WASHINGTON BLVD. NE SUITE 110 KIRKLAND, WASHINGTON 98033 (206) 739-9000 APPLICANT: SPRINT SPECTRUM 11000 NE 33RD PLACE SUITE 200 BELLEVUE, WA 98004 CONTACT: aUILDINC PERMIT APPLICATION JIM ANDERSON RUHL-PARR & ASSOCIATES 3625 132ND AVENUE SE SUITE 100 BELLEVUE, WA 98006-1399 (206) 644-4000 SITE ADDRESS: CITY OF RENTON/HIGHLANDS 3410 NE 12TH STREET RENTON, WASHINGTON 98056 PROJECT DESCRIPTION: INSTALLATION OF AN UNMANNED WIRELESS COMMUNICATION FACILITY LOCATED ON THE AN EXIST. WATER TOWER; CONSISTING OF RADIO EQUIPMENT AND (2) ANTENNA SECTORS WITH (4) PANEL ANTENNAS AT EACH SECTOR AND ONE GLOBAL POSITIONING ANTENNA. PROJECT INFO: CONSTRUCTION TYPE: NA OCCUPANY. NA NO. OF STORIES: (1) 141'-6 1/2" TALL TAX PARCEL NO.: 042305-9186-01 BUILDING CODE: UNIFORM BUILDING CODE JURISDICTION: CITY OF RENTON ZONING: R-10/RESIDENTIAL OPTIONS LEGAL DESCRIPTION: THE EAST HALF OF THE SOUTHWEST QUARTER OF THE SOUTHWEST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 4, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., IN KING COUNTY, WASHINGTON; EXCEPT THE SOUTH 30 FEET THEREOF OF STREET RIGHT OF WAY. DRAWING INDEX T TITLE SHEET, SITE PLAN, PROJ. SUMMARY, & NOTES Al ROOF PLAN, TOWER ELEVATION >% > '* o LU (0 . �. Lo 0 V � vo 0)Q m Um > Z 0 A Z Q O m C� z . �. 0 rm U) 11-- 0 z Z W a � E �_ W 0 �� _ uj V 0 CC Q) 0 U) cc d) O z a � O c � ~ Z � Z O Z 0 V W N CL CC U 6/20/96 ZONING REVISION 6/14/96 ZONING SET REV DATE DESCRIPTION PROJECT MANAGER JM ARCHITECT/ ENGINEER J L A DRAMN BY R 1A� rYfl DATE 6 14 96 CHECKED BY JM DATE THESE DRAWNGS AS 06MMENTS OF SERUCE ARE THE PROPERTY OF RUHL—PARR & ASSOCIATES, INC. Acia Architects Planners A ProNwland So -Am Cwpwolfon 3625 132nd. Aw. S.E. SURD 100 BMlevw, WA 98MG-130 (206) 644-4000 SPA//VT SPECTiQU�LI SEA TILE ENGINEERING & OPERA BONS 11000 NE 3JR0 PLACE - SUITE 200 BELLEI/(JE, WASHINGTON 98004 (206) 60 2— 2310 ZONING/PERMIT RE�x,�l�/� RENT-007-01 MAY VALLEY JUN 2 4 1996 CITY OF RENTON/HIGHLANDS 3410 NE 12TH STREET DEVELOPMENI PLANNING RENTON, WASHINGTON CITY OF RENTON 98056 DRAWNG TITLE DRAIIING NO COVER SHEET SITE PLAN 963T 14:02 20 Jun 1996 J08 NUMBER PRINT DATE 96-963 JON 2 1 1996 ICU-% _ 0 �77_