Loading...
HomeMy WebLinkAboutP_SITE_PLAN_PSE_101174060_241118_V1200 P# 1823059089 SW SUN S E T B L V D SW LA N G S T O N R D SW HARR I S P L HA R D I E A V E S W 60 P# 1823059100 280 P# 1823059149 150 P# 8663500005 BUSH TRIMMING REQUIRED AØ42112 BØ42113 CØ42114 EXISTING TO REMAIN AØ42100 BØ42101 CØ42102 EXISTING TO REMAIN AØ42115 BØ42116 CØ42117 AØ42112 BØ42113 CØ42114 EXISTING TO REMAIN AØ42100 BØ42101 CØ42102 EXISTING TO REMAIN AØEJU025 BØEJU026 CØEJU027 220 lb s 4 6 l b s EJU025 - AØ EJU026 - BØ EJU027 - CØ EXISTING 4" CONDUIT AØ42100 BØ42101 CØ42102 EXISTING TO REMAIN AØ42112 BØ42113 CØ42114 EXISTING TO REMAIN 10 1 1 7 4 0 6 0 UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP C. DOYLE 253-308-5903 5/23/24 L. NEELY 253-569-2523 5/23/24 N/A N/A N/A C. DOYLE 253-308-5903 5/23/24 N/A RENTON 604194 EAR17 CREW2 200 SW LANGS REPLACE PRI CABLES, J-BUSSES, ELBOWS 200 SW LANGSTON RD, RENTON, WA 98057 O#604194 N/A N/A 101174060 AS NOTED 1/1 KING N/A N/A QCSOKE SW 18-05-23 N/A N/A 2305E071 2305E076 2305E071 EAR-17 N/A N/A N/A N/A N/A N/A N/A N/A N/A Potelco, Inc.DESIGNED BY No No No Yes Yes Yes "Flagging Required" "Outages Required" "Locates Required" MAKE NO CHANGES TO THIS JOB WITHOUT PRIOR APPROVAL Notify Customers and Service Area 48 HRS Prior To Planned Outages ORDER#NOTIF#PROJECT PHASE MAINTENENCE O & M SUPERIOR FAILED SILICONE REMOVAL EXPENSE 12003998 101174060 N/A 108156108 593258345 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG OVERHEAD CIRCUIT MAP: 2305E076 SCALE: 6" = 1 MILE SITE SPECIFIC NOTES NOTE -ASPLUNDH TO DO BUSH TRIMMING P01 (317816-165761) -REPLACE C/O & TERM W/ 3Ø LI UG-OH TERM (6043.1001 UTSU3L1) F:65T (MID: 3412600) -REPLACE 4" RISER (6042.1000 RIS4CSS) J01 (317817-165764) -NOTE: VAULT IS FULL OF WATER -REPLACE (3) 4-POS J-BUS (MID: 7625900) -REPLACE (9) 1/0 PRI ELBOWS (6041.1000 ELB10J) -REPLACE (3) DUST CAPS (MID: 7630600) J01 (317817-165764) TO P01 (317816-165761) -REMOVE EXISTING CABLES AØ42115, BØ42116, & CØ42117 -PULL IN 3Ø 1/0 PRI THROUGH EXISTING CONDUIT APPROX 75' -ASSIGN CABLE TAGS EJU025/26/27 CREW NOTE -FOREMAN TO NOTIFY SYSOPS AND CLOSE O#604194 WHEN WORK IS COMPLETE SITE PLAN SCALE: 1:50 FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. JOB SITE L. NEELY 253-569-2523 5/23/24 PRE CONSTRUCTION UG MAP SCALE: 1:100 POST CONSTRUCTION UG MAP SCALE: 1:100 VAULT & EQUIPMENT TABLE SITE GRID NUMBER VAULT SIZE & COVER TYPE & SIZE EQUIPMENT IN VAULT PRIMARY BUSHINGS TRANSFORMER ID NUMBERS (COMPANY ID) REMARKS LB DC J01 317817 165764 EXISTING VAULT J-BOX BELOW GRADE W/ 3-4 POS. J-BUS 9 3 TOTALS :9 3 ONE-LINE DIAGRAM NOT TO SCALE PRIMARY CABLE & CONDUIT TABLE (FOREMAN TO COMPLETE) LOCATION CONDUIT PRIMARY CABLE QTY OF LUBE (gal.)REMARKS FROM TO SIZE (in)QTY DESIGN LENGTH (ft) ACTUAL LENGTH (ft) TYPE BENDS PULL (lbs) PULL REV (lbs) SIZE DESIGN LENGTH (ft) ACTUAL LENGTH (ft) CABLE NUMBERS MANUFACTURING INFORMATION For Feeder Cable Only Check applicable box DB120 HDPE SCH 80 90 45 22 11 A B C MANUFACTURER COMPOUND YEAR TAPE CN #4/0 NEU DESIGN AS BUILT J01 P01 --EXISTING 220 46 1/0 AL JKT 75 EJU025 EJU026 EJU027 0 TOTAL 4"0 TOTAL 3Ø 75'TOTAL LUBE 0 ABANDONED / REMOVE / REPLACED CABLE SCHEDULE CABLE NO. SAP EQUIP LOCATIONS CABLE (LF) EST EXISTING CABLE MFG. NAME EXISTING CABLE MFG. DATE ABANDONED CABLE LEFT IN PLACE ABANDON CIRCUITRYFROMTO 42115 10694422 J01 P01 75 NO NO 42116 10694432 J01 P01 75 NO NO 42117 10694442 J01 P01 75 NO NO TOTAL CIRCUIT FEET 75'