Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
P_Renton 2 - 10092535 - MRWOR070990_FCD 10.28.24
SD050 | 4.5L | 50 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency Standby Power Rating 50 kW, 63 kVA, 60 Hz Prime Power Rating* 45 kW, 56 kVA, 60 Hz *Assembled in the USA using domestic and foreign parts *EPA Certified Prime ratings are not available in the US or its Territories Image used for illustration purposes only Codes and Standards Not all codes and standards apply to all configurations. Contact factory for details. UL2200, UL6200, UL1236, UL489, UL142 CSA C22.2, ULC S601 TM BS5514 and DIN 6271 SAE J1349 NFPA 37, 70, 99, 110 NEC700, 701, 702, 708 ISO 3046, 7637, 8528, 9001 NEMA ICS10, MG1, 250, ICS6, AB1 ANSI C62.41 IBC 2009, CBC 2010, IBC 2012, ASCE 7-05, ASCE 7-10, ICC-ES AC- 156 (2012) Powering Ahead For over 60 years, Generac has provided innovative design and superior manufacturing. Generac ensures superior quality by designing and manufacturing most of its generator components, including alternators, enclosures and base tanks, control systems and communications software. Generac gensets utilize a wide variety of options, configurations and arrangements, allowing us to meet the standby power needs of practically every application. Generac searched globally to ensure the most reliable engines power our generators. We choose only engines that have already been proven in heavy-duty industrial applications under adverse conditions. Generac is committed to ensuring our customers’ service support continues after their generator purchase. 1 of 6 ®SPEC SHEET SD050 | 4.5L | 50 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency STANDARD FEATURES ENGINE SYSTEM • Engine Block Heater • Oil Drain Extension • Air Cleaner • Level 1 Fan and Belt Guards (Open Set Only) • Stainless Steel Flexible Exhaust Connection • Radiator Duct Adapter (Open Set Only) Fuel System • Fuel Lockoff Solenoid • Secondary Fuel Filter Cooling System • Closed Coolant Recovery System • UV/Ozone Resistant Hoses • Factory-Installed Radiator • Radiator Drain Extension Electrical System • Battery Charging Alternator • Battery Cables • Battery Tray • Rubber-Booted Engine Electrical Connections • Solenoid Activated Starter Motor ALTERNATOR SYSTEM • UL2200 GENprotect™ • Class H Insulation Material • 2/3 Pitch • Skewed Stator • Brushless Excitation • Sealed Bearing • Full Load Capacity Alternator • Protective Thermal Switch GENERATOR SET • Genset Vibration Isolation • Separation of Circuits - High/Low Voltage • Separation of Circuits - Dual Breakers • Standard Factory Testing • 2 Year Limited Warranty (Standby Rated Units) • 1 Year Limited Warranty (Prime Rated Units) ENCLOSURE (If Selected) • Rust-Proof Fasteners with Nylon Washers to Protect Finish • High Performance Sound-Absorbing Material (Sound Attenuated Enclosures) • Gasketed Doors • Upward Facing Discharge Hoods (Radiator and Exhaust) • Stainless Steel Lift Off Door Hinges • Stainless Steel Lockable Handles • RhinoCoat™ - Textured Polyester Powder Coat Paint FUEL TANKS (If Selected) • UL 142, ULC S601 • Double Wall • Vents • Sloped Top • Sloped Bottom • Factory Pressure Tested - 2 psi • Rupture Basin Alarm • Fuel Level • Check Valve In Supply and Return Lines • RhinoCoat™ - Textured Polyester Powder Coat Paint • Stainless Steel Hardware CONTROL SYSTEM Digital H Control Panel- Dual 4x20 Display Program Functions • Programmable Crank Limiter • 7-Day Programmable Exerciser • Special Applications Programmable Logic Controller • RS-232/485 Communications • All Phase Sensing Digital Voltage Regulator • 2-Wire Start Capability • Date/Time Fault History (Event Log) • Isochronous Governor Control • Waterproof/Sealed Connectors • Audible Alarms and Shutdowns • Not in Auto (Flashing Light) • Auto/Off/Manual Switch • E-Stop (Red Mushroom-Type) • NFPA110 Level I and II (Programmable) • Customizable Alarms, Warnings, and Events • Modbus® Protocol • Predictive Maintenance Algorithm • Sealed Boards • Password Parameter Adjustment Protection • Single Point Ground • 16 Channel Remote Trending • 0.2 msec High Speed Remote Trending • Alarm Information Automatically Annunciated on the Display Full System Status Display • Power Output (kW) • Power Factor • kW Hours, Total, and Last Run • Real/Reactive/Apparent Power • All Phase AC Voltage • All Phase Currents • Oil Pressure • Coolant Temperature • Coolant Level • Engine Speed • Battery Voltage • Frequency Alarms and Warnings • Oil Pressure • Coolant Temperature • Coolant Level • Engine Overspeed • Battery Voltage • Alarms and Warnings Time and Date Stamped • Snap Shots of Key Operation Parameters During Alarms and Warnings • Alarms and Warnings Spelled Out (No Alarm Codes) 2 of 6 SPEC SHEET SD050 | 4.5L | 50 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency CONFIGURABLE OPTIONS ENGINE SYSTEM ○ Oil Heater ○ Industrial Silencer ○ Level 1 Fan and Belt Guards (Enclosed Units Only) ○ Critical Grade Silencer (Open Set Only) ○ Air Filter Restriction Indication ○ Radiator Stone Guard (Open Set Only) FUEL SYSTEM ○ NPT Flexible Fuel Line ELECTRICAL SYSTEM ○ Battery Heater ○ 10A UL Listed Battery Charger CIRCUIT BREAKER OPTIONS ○ Main Line Circuit Breaker ○ 2nd Circuit Breaker ○ Shunt Trip Wand Auxiliary Contacts ○ Electronic Trip Breakers GENERATOR SET ○ 8 Position Load Center ○ Extended Factory Testing ALTERNATOR SYSTEM ○ Alternator Upsizing ○ Anti-Condensation Heater ○ Tropical Coating ○ Permanent Magnet Excitation ENCLOSURE ○ Weather Protected Enclosure ○ Level 1 Sound Attenuated Enclosure ○ Level 2 Sound Attenuated Enclosure ○ Steel Enclosure ○ Aluminum Enclosure ○ IBC Seismic Certified ○ AC/DC Enclosure Light Kits (Enclosed Units Only) ○ Door Open Alarm Switch ○ Pad Vibration Isolators ○ Up to 200 MPH Wind Load Rating (Contact Factory for Availability) CONTROL SYSTEM ○ NFPA 110 Level 1 Compliant 21-Light Remote Annunciator ○ Remote Relay Assembly (8 or 16) ○ Oil Temperature Indication and Alarm ○ Remote E-Stop (Break Glass-Type, Surface Mount) ○ Remote E-Stop (Red Mushroom-Type, Surface Mount) ○ Remote E-Stop (Red Mushroom-Type, Flush Mount) ○ E-Stop Terminal ○ Remote Communication - Modem ○ 10A Engine Run Relay ○ Ground Fault Annunciator ○ 100 dB Alarm Horn ○ 120V GFCI and 240V Outlets WARRANTY (Standby Gensets Only) ○ 2 Year Extended Limited Warranty ○ 5 Year Limited Warranty ○ 5 Year Extended Limited Warranty ○ 7 Year Extended Limited Warranty ○ 10 Year Extended Limited Warranty FUEL TANKS (Size on Last Page) ○ 8 in Fuel Extension ○ 13 in Fuel Extension ENGINEERED OPTIONS ENGINE SYSTEM ○ Coolant Heater Ball Valves ○ Fluid Containment Pan CONTROL SYSTEM ○ Battery Disconnect Switch ○ Battery Box GENERATOR SET ○ Special Testing ○ Battery Box ENCLOSURE ○ Motorized Dampers ○ Enclosure Heater FUEL TANKS ○ Overfill Protection Valve ○ UL 2085 Tank ○ Special Fuel Tanks ○ External Vent Extensions ○ Tank Risers ○ 5 Gallon Spill Box ○ Lockable Fuel Fill ○ Pipe Flanges ○ 90% High Fuel Alarm 3 of 6 SPEC SHEET SD050 | 4.5L | 50 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency APPLICATION AND ENGINEERING DATA ENGINE SPECIFICATIONS General Make Iveco/FPT EPA Emissions Compliance Stationary Emergency EPA Emissions Reference See Emission Data Sheet Cylinder # 4 Type In-Line Displacement - in3 (L) 274 (4.5) Bore - in (mm) 4.1 (105) Stroke - in (mm) 5.2 (132) Compression Ratio 17.5:1 Intake Air Method Turbocharged Cylinder Head Type 2-Valve Piston Type Aluminum Crankshaft Type Forged Steel Engine Governing Governor Electronic Isochronous Frequency Regulation (Steady State) ±0.25% Lubrication System Oil Pump Type Gear Driven Oil Filter Type Full-Flow Cartridge Crankcase Capacity - qt (L) 14.4 (13.6) Cooling System Cooling System Type Closed Recovery Water Pump Type Belt Driven Centrifugal Fan Type Pusher Fan Speed - RPM 2,538 Fan Diameter - in (mm) 26 (660) Fuel System Fuel Type Ultra Low Sulfur Diesel Fuel Fuel Specifications ASTM Fuel Filtering (Microns) 5 Fuel Pump Type Engine Driven Gear Injector Type Mechanical Fuel Supply Line - in (mm) 0.5 (12.7) NPT Fuel Return Line - in (mm) 0.5 (12.7) NPT Engine Electrical System System Voltage 12 VDC Battery Charger Alternator 20 A Battery Size See Battery Index 0161970SBY Battery Voltage 12 VDC Ground Polarity Negative ALTERNATOR SPECIFICATIONS Standard Model K0050124Y21 Poles 4 Field Type Revolving Insulation Class - Rotor H Insulation Class - Stator H Total Harmonic Distortion <5% (3-Phase Only) Telephone Interference Factor (TIF) <50 Standard Excitation Synchronous Brushless Bearings One, Pre-Lubed and Sealed Coupling Direct via Flexible Disc Prototype Short Circuit Test Yes Voltage Regulator Type Digital Number of Sensed Phases All Regulation Accuracy (Steady State) ±0.25% 4 of 6 SPEC SHEET SD050 | 4.5L | 50 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency OPERATING DATA POWER RATINGS Standby Single-Phase 120/240 VAC @1.0pf 50 kW Amps: 208 Three-Phase 120/208 VAC @0.8pf 50 kW Amps: 173 Three-Phase 120/240 VAC @0.8pf 50 kW Amps: 150 Three-Phase 277/480 VAC @0.8pf 50 kW Amps: 75 Three-Phase 346/600 VAC @0.8pf 50 kW Amps: 60 MOTOR STARTING CAPABILITIES (skVA) skVA vs. Voltage Dip FUEL CONSUMPTION RATES* Fuel Pump Lift- ft (m) Percent Load Standby 3 (1) 25% 1.2 (4.4) 50% 2.3 (8.5) Total Fuel Pump Flow (Combustion + Return) - gph (Lph) 75% 3.2 (12.2) 13.6 (51.5) 100% 4.2 (15.8) * Fuel supply installation must accommodate fuel consumption rates at 100% load. COOLING Standby Coolant Flow gpm (Lpm) 32.7 (123.8) Coolant System Capacity gal (L) 4.5 (17.4) Heat Rejection to Coolant BTU/hr (kW) 121,000 (35.5) Inlet Air scfm (m3/min) 6,360 (180) Maximum Operating Radiator Air Temperature °F (°C) 122 (50) Maximum Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD Maximum Additional Radiator Backpressure in H2O (kPa) 0.5 (0.12) COMBUSTION AIR REQUIREMENTS Standby Flow at Rated Power - scfm (m3/min) 205 (5.8) ENGINE Standby EXHAUST Standby Rated Engine Speed RPM 1,800 Exhaust Flow (Rated Output) scfm (m3/min) 497 (14.1) Horsepower at Rated kW** hp 80 Maximum Allowable Backpressure (Post Silencer) inHg (kPa) 1.5 (5.1) Piston Speed ft/min (m/min) 1,559 (475) Exhaust Temperature (Rated Output - Post Turbo) °F (°C) 850 (454) BMEP psi (kPa) 128.5 (886) ** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes. Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528, and DIN6271 standards. Standby - See Bulletin 10000018933 Prime - See Bulletin 10000018926 5 of 6 SPEC SHEET 277/480 VAC 30% 208/240 VAC 30% K0050124Y21 98 K0050124Y21 75 K0060124Y21 124 K0060124Y21 95 Diesel - gph (Lph) SD050 | 4.5L | 50 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency DIMENSIONS AND WEIGHTS* OPEN SET H Run Time - Hours Usable Capacity - Gal (L) L x W x H - in (mm) Weight - lbs (kg) No Tank - 76.5 (1,942) x 37.4 (950) x 52.6 (1,335) 2,141 - 2,488 (941 - 1,128) W 12 54 (204) 76.5 (1,942) x 37.4 (950) x 65.6 (1,665) 2,621 - 2,968 (1,159 - 1,346) 31 132 (500) 76.5 (1,942) x 37.4 (950) x 77.6 (1,970) 2,851 - 3,198 (1,263 - 1,450) 50 211 (799) 76.5 (1,942) x 37.4 (950) x 89.6 (2,275) 3,060 - 3,407 (1,358 - 1,545) 71 300 (1,136) 92.9 (2,360) x 37.4 (950) x 93.1 (2,364) 3,123 - 3,470 (1,386 - 1,573) 121 510 (1,931) 116.5 (2,960) x 46.5 (1,180) x 95.0 (2,411) 3,506 - 3,853 (1,562 - 1,749) WEATHER PROTECTED ENCLOSURE Run Time H - Hours Usable Capacity - Gal (L) L x W x H - in (mm) Weight - lbs (kg) No Tank - 94.8 (2,409) x 38.0 (965) x 49.5 (1,258) Steel: 2,588 - 3,017 (1,174 - 1,368) Aluminum: 2,366 - 2,748 (1,073 - 1,246) Steel: 3,068 - 3,497 (1,392 - 1,586) W 12 54 (204) 94.8 (2,409) x 38.0 (965) x 62.5 (1,588) Aluminum: 2,846 - 3,228 (1,291 - 1,464) 31 132 (500) 94.8 (2,409) x 38.0 (965) x 74.5 (1,893) Steel: 3,298 - 3,727 (1,496 - 1,690) Aluminum: 3,076 - 3,458 (1,395 - 1,568) 50 211 (799) 94.8 (2,409) x 38.0 (965) x 86.5 (2,198) Steel: 3,507 - 3,936 (1,591 - 1,785) Aluminum: 3,285 - 3,667 (1,490 - 1,663) 71 300 (1,136) 94.8 (2,409) x 38.0 (965) x 90.0 (2,287) Steel: 3,570 - 3,999 (1,619 - 1,813) Aluminum: 3,348 - 3,730 (1,518 - 1,691) 121 510 (1,931) 116.5 (2,960) x 46.5 (1,180) x 91.9 (2,334) Steel: 3,953 - 4,382 (1,795 - 1,989) Aluminum: 3,731 - 4,113 (1,694 - 1,867) LEVEL 1 SOUND ATTENUATED ENCLOSURE Run Time H - Hours Usable Capacity - Gal (L) L x W x H - in (mm) Weight - lbs (kg) No Tank - 112.5 (2,857) x 38.0 (965) x 49.5 (1,258) Steel: 2,668 - 3,178 (1,210 - 1,441) Aluminum: 2,366 - 2,748 (1,073 - 1,246) Steel: 3,148 - 3,658 (1,428 - 1,659) 12 54 (204) 112.5 (2,857) x 38.0 (965) x 62.5 (1,588) W Aluminum: 2,846 - 3,228 (1,291 - 1,464) 31 132 (500) 112.5 (2,857) x 38.0 (965) x 74.5 (1,893) Steel: 3,378 - 3,888 (1,532 - 1,763) Aluminum: 3,076 - 3,458 (1,395 - 1,568) 50 211 (799) 112.5 (2,857) x 38.0 (965) x 86.5 (2,198) Steel: 3,587 - 4,097 (1,627 - 1,858) Aluminum: 3,285 - 3,667 (1,490 - 1,663) 71 300 (1,136) 112.5 (2,857) x 38.0 (965) x 90.0 (2,287) Steel: 3,650 - 4,160 (1,655 - 1,886) Aluminum: 3,348 - 3,730 (1,518 - 1,691) 121 510 (1,931) 116.5 (2,960) x 46.5 (1,180) x 91.9 (2,334) Steel: 4,033 - 4,543 (1,831 - 2,062) Aluminum: 3,731 - 4,113 (1,694 - 1,867) LEVEL 2 SOUND ATTENUATED ENCLOSURE Run Time - Hours H Usable Capacity - Gal (L) L x W x H - in (mm) Weight - lbs (kg) No Tank - 94.8 (2,409) x 38.0 (965) x 62.0 (1,573) Steel: 2,820 - 3,306 (1,297 - 1,499) Aluminum: 2,466 - 2,872 (1,118 - 1,303) 12 54 (204) 94.8 (2,409) x 38.0 (965) x 75.0 (1,903) Steel: 3,300 - 3,786 (1,497 - 1,717) Aluminum: 2,946 - 3,352 (1,336 - 1,521) W Steel: 3,530 - 4,016 (1,601 - 1,821) 31 132 (500) 94.8 (2,409) x 38.0 (965) x 87.0 (2,208) Aluminum: 3,176 - 3,582 (1,440 - 1,625) 50 211 (799) 94.8 (2,409) x 38.0 (965) x 99.0 (2,513) Steel: 3,739 - 4,225 (1,696 - 1,916) Aluminum: 3,385 - 3,791 (1,535 - 1,720) 71 300 (1,136) 94.8 (2,409) x 38.0 (965) x 102.5 (2,602) Steel: 3,802 - 4,288 (1,724 - 1,944) Aluminum: 3,448 - 3,854 (1,563 - 1,748) 121 510 (1,931) 116.5 (2,960) x 46.5 (1,180) x 104.4 (2,649) Steel: 4,185 - 4,671 (1,900 - 2,120) Aluminum: 3,831 - 4,237 (1,739 - 1,924) * All measurements are approximate and for estimation purposes only. Specification characteristics may change without notice. Please contact a Generac Power Systems Industrial Dealer for detailed installation drawings. Generac Power Systems, Inc. | P.O.Box 8 | Waukesha, WI 53189 P: (262) 544-4811 ©2020 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 0191740SBY Rev. F 04/14/2020 6 of 6 L L L L SPEC SHEET LEVEL 2 SOUND ATTENUATED ENCLOSURE D4.5L SD050 60Hz NO-LOAD, dB(A) DISTANCE: 7 METERS MICROPHONE LOCATION OCTAVE BAND CENTER FREQUENCY (Hz) 31.5 63 125 250 500 1,000 2,000 4,000 8,000 dB(A) FRONT 31 56 59 58 62 58 54 50 42 66 RIGHT 31 58 55 58 59 55 50 47 41 65 REAR 29 60 54 56 60 54 49 45 38 65 LEFT 30 55 57 58 60 57 53 49 43 65 AVERAGE 30 57 57 57 60 56 51 48 41 65 60Hz FULL-LOAD, dB(A) DISTANCE: 7 METERS MICROPHONE LOCATION OCTAVE BAND CENTER FREQUENCY (Hz) 31.5 63 125 250 500 1,000 2,000 4,000 8,000 dB(A) FRONT 31 61 67 59 64 60 57 56 50 71 RIGHT 30 57 62 60 61 58 55 52 46 67 REAR 27 65 60 61 61 56 52 51 43 69 LEFT 29 65 67 60 63 58 58 55 49 71 AVERAGE 30 62 64 60 62 58 55 53 47 69 RIGHT FRONT REAR LEFT • All positions at 23 feet (7 meters) from side faces of generator set. • Test conducted on a 100 foot diameter asphalt surface. • Sound pressure levels are subject to instrumentation, installation and testing conditions. • Sound levels are ±2 dB(A). Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2020 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. A0000771413 Rev. A 05/18/20 1 OF 1 72 70 68 66 64 62 FRONT RIGHT REAR LEFT dB(A) SOUND DATA