Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutMFP25000048.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP25000048
IVR Number: 25000048
Permit Information
Permit Name: P.279611
Address/Location:01/03/2025Application Date:1723059103Parcel Number: 2003 MAPLE VALLEY HWY, SUITE 101
Permit Type:01/15/2025Issue Date:Franchise
Permit Work Class:01/15/2026Expiration Date:Minor Utility
Job Number: P.279611Franchise Type:Telephone
Description: IN MH 294, PUSH LRE23, 35 36 FROM EXISTING FIBER CABLE [TFB9] TO EXISTING FIBER CABLE [A3RL8]. IN
DISH HH, SPLICE FIBER CABLE [A3RL8] TO NEW FIBER CABLE , TRENCH IN DIRT APPROX 200' PLACING 2" UG
INTO THE MPOP. RESTORATION PER CITY OF RENTON STANDARDS
Contacts
Name Address PhoneTypeBilling
Nathan Macleod
Lumen
7850 S Trafton St, Bldg B
Tacoma, WA 98409
C: (253) 583-6283ApplicantX
Angelina Maxwell
CentryLink/Lumen
4201 SW GRAHAM ST 1, 1
Seattle, WA 98136
B: (206) 945-0048Applicant
Kim Parker
QWest Corporation
931 14th St, Suite 1000A
Denver, CO 80202
B: (303) 992-0752Contact
Cheyenne Classen
North Sky Communications
2112 97th Ave E
Tacoma, WA 98444
Contact
Michael Smith
North Sky Communications
21320 84th Ave S
Kent, WA 98032
C: (206) 305-5881Contractor
Business License Number: 36846Construction Contractor: NORTHSC857Q4
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 10/27/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 10/27/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐ Electronic Copy of the TCP Application
☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
Include map(s) showing the location of the project and work area.
Be legible lettering and clear, contrasting, symbols of viewing or printing.
Must indicate street names, and north arrow and scale.
Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 10/27/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
Must have approved Traffic Control Plan (TCP) prior to commencing the work.
Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
Comply with all traffic regulations of the City of Renton and the State of Washington.
Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends
and holidays) prior to starting any work.
Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum
of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a
temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a
minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140
with any questions.
Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
All permit conditions shall be met.
NOTES:
Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
Approved Temporary Traffic Control Plan must be at the work site during work hours.
Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 10/27/2021
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
DRIVEWAYMAPLE VALLEY HWY1111121111
ROADWORKAHEADW20-1
HH X
LOCATION:2003 MAPLE VALLEY HWYRENTON, WA 98057
ROADWORKAHEADW20-1 X XRIGHT LANECLOSEDAHEADW20-5 XW4-2LegendArrowboard (Chevron)ConeHHHandholeTrenchingWork AreaWork Truck With Lights
ALL CONTROL SET-UP, SIGN SPACING, SIGN SIZING, AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN FEDERAL MANUAL ONUNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTEDSPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIRJURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITETRAFFIC CONTROL PERSONEL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.Date:12/24/24 Author:GEORGIA ZIMMERMAN Project:P.279611Comments: SINGLE RIGHT LANE CLOSUREACCESSING HH IN CITY RENTONTRENCHING FROM HH T0 CUSTOMERPEDESTRIAN SPOTTERS REQUIRED
TRAFFIC CONTROL PLANHH TRENCHINGSHEET 1 OF 1TCS CERTIFIEDNAME: GEORGIA ZIMMERMANI.D. NO: 9F413BCARD NO: ES2 000405EXPIRATION: 1/31/2028SIGNATURE: CONTACT: (206) 573-2996R
L
B
PLAN NOT TO SCALENSPEEDLIMIT35
www.invarion.com
ONLYMAPLE VALLEY HW
Y
405 OFF RAMP
405 OFF RAMP405 ON RAMP1111
11
25
111213SHOULDERSHOULDERSIDEWALKSIDEWALK16
11SIDEWALK
LOCATION: 1820 Maple Valley Hwy,Renton, WA 98057
MH294
MATCH LINE
MH29445' X 13'B
L
R
L
BL/3
ROADWORKAHEADW20-1 X X XLANESHIFTAHEADW5-5 W1-4
LegendArrowboard (Chevron)ConeSpotterWork AreaWork Truck With Lights
ALL CONTROL SET-UP, SIGN SPACING, SIGN SIZING, AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN FEDERAL MANUAL ONUNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTEDSPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIRJURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITETRAFFIC CONTROL PERSONEL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.
Date:12/24/24 Author:GEORGIA ZIMMERMAN Project:P.273611Comments: SINGLE RIGHT LANE CLOSURE - LANE SHIFTACCESSING MH 294 IN CITY RENTONPEDESTRIAN SPOTTERS REQUIRED
TRAFFIC CONTROL PLANMH #294SHEET 1 OF 2TCS CERTIFIEDNAME: GEORGIA ZIMMERMANI.D. NO: 9F413BCARD NO: ES2 000405EXPIRATION: 1/31/2028SIGNATURE: CONTACT: (206) 573-2996
PLAN NOT TO SCALE
N SPEEDLIMIT35
www.invarion.com
RRRRRRRRONLYONLY
BRONSON WAY N
SUNSET BLVD N
MAPLE VALLEY H
W
Y MAPLE VAL
L
E
Y
H
W
Y
1111
12121212
14 16 12 11
11 11 SIDEWALK SIDEWALK405 ON RAMP
MATCH LINE
ROADWORKAHEADW20-1 X XRIGHT LANECLOSEDAHEADW20-5 XW4-2
L
ROADWORKAHEADW20-1
XXRIGHT LANECLOSEDAHEADW20-5
XW4-2LegendArrowboard (Chevron)ConeALL CONTROL SET-UP, SIGN SPACING, SIGN SIZING, AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN FEDERAL MANUAL ONUNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTEDSPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIRJURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITETRAFFIC CONTROL PERSONEL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.
Date:12/24/24 Author:GEORGIA ZIMMERMAN Project:P.279611Comments: SINGLE RIGHT LANE CLOSURE - LANE SHIFTACCESSING MH 294 IN CITY OF RENTONPEDESTRIAN SPOTTERS REQUIRED
TRAFFIC CONTROL PLANMH #294SHEET 2 OF 2
SPEEDLIMIT35N
TCS CERTIFIEDNAME: GEORGIA ZIMMERMANI.D. NO: 9F413BCARD NO: ES2 000405EXPIRATION: 1/31/2028SIGNATURE: CONTACT: (206) 573-2996
PLAN NOT TO SCALE
www.invarion.com
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE:WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.0020000000”NVICINITY MAPSCOPE OF WORK:IN MH 294, PUSH LRE23, 35-36 FROM EXISTING FIBER CABLE [TFB9] TO EXISTING FIBER CABLE [A3RL8]. IN DISH HH,SPLICE FIBER CABLE [A3RL8] TO NEW FIBER CABLE , TRENCH IN DIRT APPROX 200' PLACING 2" UG INTO THEMPOP.DRAFTED BY: MOUNTAIN LTD/DL - 12/03/24FIELD ENGINEER: RICK FERDINANDOPHONE NO: (720) 394-3609EMAIL: RICK.FERDINANDO@LUMEN.COM23N5E17P.279611 W26226RNTNWA012003 MAPLE VALLEY HWY RENTON, WA 9805714FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400R
TTEE CATV CATV CATV GG TS TS WW S S SD SD IRRIG IRRIG C/L C/L R/W R/W R/W P/L P/L
B/C B/C B/C EOP EOP TTTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'XITEM #STATIONPSEPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHERITEM#STAHT-CL-YRXX'-X"POLE#MAKE READYEXISTING ATTACHMENTSNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF RNGE:SECT:TOWN:GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSFIELD ENGINEER: RICK FERDINANDOPHONE NO: (720) 394-3609EMAIL: RICK.FERDINANDO@LUMEN.COMRDRAFTED BY: MOUNTAIN LTD/DL - 12/03/2423N5E17P.279611 W26226RNTNWA012003 MAPLE VALLEY HWY RENTON, WA 9805724FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSFIELD ENGINEER: RICK FERDINANDOPHONE NO: (720) 394-3609EMAIL: RICK.FERDINANDO@LUMEN.COMRDRAFTED BY: MOUNTAIN LTD/DL - 12/03/24#17230590131717SPEEDLIMIT23N5E17P.279611 W26226RNTNWA012003 MAPLE VALLEY HWY RENTON, WA 9805734FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400 R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP T#1723059132182049'48'65'82'4'120'
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSFIELD ENGINEER: RICK FERDINANDOPHONE NO: (720) 394-3609EMAIL: RICK.FERDINANDO@LUMEN.COMRDRAFTED BY: MOUNTAIN LTD/DL - 12/03/24#17230591032003SPEEDLIMIT23N5E17P.279611 W26226RNTNWA012003 MAPLE VALLEY HWY RENTON, WA 9805744FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400 EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W P/L P/L P/L P/L P/L P/L TNOTE:TRENCH IN DIRT 200' +24F + 2" UG TO MPOP.EXISTING GRADETRENCH PLACEMENT OF ( " MIN.)N.T.S.TYPICAL DETAIL " "6"MIN. "MIN.
COVER
A3636
1-1 1/4-SDR91-1 1/4 SDR9