CONTROL PANEL IN LINE OF
SIGHT OF PPUMP CHAMBER
1,500 GALLON SEPTIC TANK1
3"Ø TRANSPORT LINE
2
3
4
LEGEND
1,500 PUMP CHAMBER
SL#SOIL LOG
W WATER LINE
4004 NE 4TH ST., #107-508
RENTON, WA 98056
425.457.6029
425.432.4461 FAX
WI
L
L
I
A
M
S
R
E
S
I
D
E
N
C
E
ON
-
S
I
T
E
S
E
W
A
G
E
D
I
S
P
O
S
A
L
D
E
S
I
G
N
13
4
1
1
S
E
1
5
1
S
T
S
T
R
E
E
T
R
E
N
T
O
N
KI
N
G
C
O
U
N
T
Y
4" MAX
NTSINSTALL CLEANOUTS ON ALL LATERALS
LATERAL CLEANOUT/ MONITORING PORT
6" PERF. PVC PIPE WITH 1/2"∅ HOLES
DRILLED 3" O.C. FOR BOTTOM 12" OF
PORT.
ORIGINAL GROUND SURFACE
CUT SLOT IN 6" PVC FOR UPTURN LATERAL
INSTALL 1/2" REBAR THROUGH PVC PIPE TO
EXTEND TWO FEET ON EACH SIDE
BOTTOM OF TRENCH (INFILTRATIVE SURFACE)
SET CAP FLUSH WITH
FINISHED GRADE
FPT CAP
MPT X SOC
DRILL ONE HOLE UPWARD AT END
OF LATERAL FOR TEST.
45° ELBOW
LATERAL END
FINISHED GRADE
SECTION VIEW
1.THE APPROVAL OF THE ON-SITE SEWAGE DISPOSAL DESIGN IS NOT A PERMIT TO CLEAR THE PARCEL. A SEPARATE PERMIT MAY BE
REQUIRED FROM THE COUNTY TO CLEAR ANY PORTION OF THE PARCEL.
2.SENSITIVE AREAS MAY BE PRESENT NEAR THE DRAIN FIELD AREA THAT MAY EFFECT THE INSTALLATION OF THE DRAIN FIELD.
SEPARATE PERMITS MAY BE REQUIRED FROM THE COUNTY FOR SENSITIVE AREA ISSUES.
3.EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO COMMENCING
CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE DESIGNER ASSUMES NO
RESPONSIBILITY FOR UTILITIES SHOWN, OR NOT SHOWN IN THEIR PROPER LOCATION.
4.THE USE OF GARBAGE GRINDERS IS NOT RECOMMENDED. ELIMINATING THE USE OF GARBAGE DISPOSAL WILL IMPROVE
WASTEWATER SYSTEM PERFORMANCE. THIS DESIGN IS BASED ON A SYSTEM WITHOUT A GARBAGE GRINDER. INSTALLATION OF A
GARBAGE GRINDER WILL NECESSITATE INCREASING SEPTIC TANK SIZE AND MORE FREQUENT MONITORING OF THE SOLIDS LEVELS
IN THE SEPTIC TANK.
5.CONTOURS, BUILDINGS, SOIL LOGS, AND OTHER SITE FEATURES ARE SHOWN FOR REFERENCE AND ARE NOT SURVEYED. ALL
ELEVATIONS ARE BASED ON FIELD MEASUREMENTS AND CONDITIONS MAY CHANGE BASED ON CONSTRUCTION ACTIVITY. THIS PLAN
DOES NOT REPRESENT AN ACTUAL FIELD SURVEY AND IS FOR SEPTIC DESIGN PURPOSES ONLY.
6.CALL 811 TWO WORKING DAYS BEFORE YOU DIG OR VISIT HTTP://WWW.CALLBEFOREYOUDIG.ORG/
GENERAL NOTES:
PLAN NOTES:
1.A COUNTY PERMIT IS REQUIRED FOR THE CONSTRUCTION OF THIS DESIGN. THIS DESIGN MAY ONLY BE INSTALLED IF
STAMPED APPROVED BY THE COUNTY AND MAY ONLY BE INSTALLED BY A COUNTY CERTIFIED INSTALLER.
2.ALL WORK SHALL CONFORM TO COUNTY STANDARDS AND GUIDELINES. STANDARDS AND GUIDELINES NOT SPECIFIED BY
THE COUNTY SHALL CONFORM TO THE WASHINGTON ADMINISTRATIVE CODE (WAC) CONCERNING ON-SITE SEPTIC
SYSTEMS (WAC 246-272A) AND THE LATEST EDITION OF THE WASHINGTON STATE DEPARTMENT OF HEALTH (WSDOH)
RECOMMENDED STANDARDS AND GUIDELINES FOR PRESSURE DISTRIBUTION SYSTEMS AND SUBSURFACE DRIP SYSTEMS.
3.A COPY OF THE APPROVED PLAN SET SHALL BE KEPT AT THE JOB SITE AT ALL TIMES.
4.THE BEDS SHALL FOLLOW THE ORIGINAL GROUND SURFACE CONTOURS AND BE LEVEL. INSTALL THE BEDS AS SHOWN ON
THE PLAN VIEW LAYOUT
5.STOCKPILE THE BACKFILL AND CONSTRUCTION MATERIALS ADJACENT TO THE PROPOSED DRAIN FIELD BUT NOT IN THE
RESERVE DRAIN FIELD AREA.
6.AN INSPECTION OF THE SYSTEM BY THE DESIGNER IS REQUIRED PRIOR TO BACKFILLING OVER THE SEPTIC TANKS,
TRANSPORT LINE TRENCHES AND THE DRAIN FIELD.
7.INSTALL CLEANOUTS EVERY 50' ALONG GRAVITY PIPE RUNS AND AT ANGLE POINTS.
8.ALL VALVES AND FILTERS SHALL BE READILY ACCESSIBLE FOR INSPECTION AND SERVICING.
9.CHANGES IN TANK CONFIGURATION OR LOCATION MUST BE APPROVED BY THE DESIGNER OR DESIGN MAY BE INVALID.
10.IF THE DRAIN FIELD SOIL IS DISTURBED PRIOR TO INSTALLATION, THE DESIGN MAY BE VOID.
11.ANY CUTS INTRODUCED WITHIN 50' OF THE DRAIN FIELD AREA MAY VOID THE DESIGN.
12.TREES AND/OR STUMPS GREATER THAN 18" IN DIAMETER, WHEN MEASURED 2 FEET ABOVE GRADE, MAY BE CUT AT
GROUND LEVEL OR BURNED IN PLACE TO AVOID DISTURBING THE SOIL. IF TREES ARE TO BE REMOVED, LEAVE STUMPS
AND ROOTS IN THE GROUND. MOW OTHER VEGETATION TO GROUND SURFACE.
13.MAINTAIN 10FT SETBACK FROM ALL WATER/IRRIGATION LINES AND ANY SEPTIC COMPONENTS. EXISTING IRRIGATION
AND WATER LINES SHALL BE REMOVED OR RELOCATED AS NECESSARY. PERPENDICULAR CROSSINGS ARE ALLOWED. SEE
SEWER/WATER CROSSING DETAIL FOR PROPER METHOD OF CROSSING.
14.FLOOR DRAINS SHALL NOT BE CONNECTED TO THE SEPTIC SYSTEM. DRAINS FROM ANY COMMERCIALLY MADE TUB,
SHOWER, BASIN, SINK, OR TOILET ARE NOT CONSIDERED FLOOR DRAINS.
15.NO ROOF, FOOTING, OR SURFACE DRAINS SHALL BE CONNECTED TO THE SEPTIC SYSTEM.
16.FOOTING DRAINS WILL NOT BE ALLOWED WITHIN 30' DOWN SLOPE OF THE DRAIN FIELD. STORM WATER DISPERSION OR
INFILTRATION TRENCHES ARE NOT ALLOWED WITHIN 100' UPHILL OF DRAIN FIELD OR 30' DOWN SLOPE OF THE DRAIN
FIELD. DIRECT ALL STORM WATER RUNOFF (ROOF, FOOTING, ETC.) AWAY FROM THE DRAIN FIELD AND TANKS.
17.DETAILS SHOWN ARE SCHEMATIC. SEE PLAN VIEW FOR ACTUAL CONFIGURATION.
MATERIALS:
1.ALL PLUMBING MUST BE OF PVC MATERIAL.
2.THE SIDE-SEWER CONNECTION PIPE AND ALL PIPING BETWEEN SEPTIC TANKS SHALL BE MIN. 4-INCH DIAMETER ASTM
D3034 SDR-35 PVC.
3.CLASS 200 PVC SHALL MEET THE REQUIREMENTS OF ASTM D2241 SDR-21 PVC.
4.SCHEDULE 40 & SCHEDULE 80 PVC SHALL MEET THE REQUIREMENTS OF ASTM D1785.
5.TANKS SHALL BE CONCRETE AND BE INCLUDED ON THE WASHINGTON STATE HEALTH DEPARTMENT LIST OF REGISTERED
SEWAGE TANKS (WAC 246-272C). SUBSTITUTION OF MATERIAL MAY BE ALLOWED WITH DESIGNER REVIEW AND
APPROVAL.
6.ALL TANK INLET/OUTLET GASKETS SHALL CONSIST OF A RUBBERIZED MATERIAL THAT IS CAST INTO THE TANK WALL,
MUST BE ABLE TO WITHSTAND VIBRATION AND/OR SETTLING, RESISTANT TO SEWER GASSES, AND CAPABLE OF
ACCEPTING A NON-CORROSIVE CLAMP AND SCREW TO SECURE THE CONNECTING PIPE.
7.THE SEALANT BETWEEN TANK RIM AND LID, AND BETWEEN THE TANK LID AND RISER MUST BE ABLE TO PROVIDE A
WATERTIGHT SEAL REGARDLESS OF WEATHER CONDITIONS OR TEMPERATURE DURING SEALANT APPLICATION.
8.TANK RISERS SHALL BE PVC, WATERTIGHT, AND HAVE A SOLID LOCKING LID. ELECTRICAL AND EFFLUENT PIPES THAT
EXIT THE RISER MUST USE A RUBBERIZED GASKET WITH A WATERTIGHT SEAL THAT MUST BE ABLE TO WITHSTAND
VIBRATION AND/OR SETTLING AND RESISTANT TO SEWER GASSES.
9.ALL VALVE BOXES SHALL BE NON-CONCRETE (POLYPROPELENE, HDPE, ETC) AND HAVE RISERS TO FINISHED GRADE.
VALVE BOXES SHALL BE SET AND LEVELED ON A PEA GRAVEL BASE UNLESS OTHERWISE NOTED.
10.ALL MATERIALS AND MECHANICAL/ELECTRICAL COMPONENTS SHALL BE RATED FOR USE IN WASTEWATER APPLICATIONS.
11.SUBSTITUTION OF ANY PARTS LISTED MUST HAVE THE APPROVAL OF THE DESIGNER.
12.SEE INDIVIDUAL DETAILS FOR MATERIALS NOT LISTED HERE.
13.THE GEOTEXTILE (FILTER FABRIC) SHALL BE NON-WOVEN, FREE OF ANY CHEMICAL TREATMENT OR COATING WHICH
REDUCES PERMEABILITY, INERT TO CHEMICALS COMMONLY FOUND IN SOIL, AND MEET OR EXCEED THE "MINIMUM
AVERAGE ROLL VALUES" LISTED IN TABLE 3, "GEOTEXTILE SPECIFICATIONS" OF THE LATEST EDITION OF THE WSDOH
RECOMMENDED STANDARDS AND GUIDELINES FOR DOSING GRAVITY SYSTEMS.
14.DRAIN ROCK SHALL BE WASHED GRAVEL OR CRUSHED ROCK RANGING IN SIZE FROM THREE-QUARTERS INCH TO TWO
AND ONE-HALF INCHES, AND CONTAINING NO MORE THAN TWO PERCENT BY WEIGHT PASSING A US NO. 8 SIEVE AND NO
MORE THAN ONE PERCENT BY WEIGHT PASSING A US NO. 200 SIEVE.
4004 NE 4TH ST., #107-508
RENTON, WA 98056
425.457.6029
425.432.4461 FAX
WI
L
L
I
A
M
S
R
E
S
I
D
E
N
C
E
ON
-
S
I
T
E
S
E
W
A
G
E
D
I
S
P
O
S
A
L
D
E
S
I
G
N
13
4
1
1
S
E
1
5
1
S
T
S
T
R
E
E
T
R
E
N
T
O
N
KI
N
G
C
O
U
N
T
Y
NTS
SLOPE TO DRAIN
DOSING CHAMBER
PROFILE VIEW
1,500 GALLONS
SINGLE COMPARTMENT
SEPTIC TANK
PROFILE VIEW
1,500 GALLONS
DOUBLE COMPARTMENT
2/3 TOTAL
VOLUME
APPROXIMATE
WATER TABLE
ELEVATION ± 70'
4"∅ PVC
@ 2.00% MIN.
I.E.= ± 75.0'
24" LOCKING GAS TIGHT MANHOLE
COVER. FASTEN WITH FOUR SCREWS
PER LID. USE #3 SQUARE DRIVE OR
LARGER.
COVER MAY VARY
12"-36"
SEPTIC TANK AND DOSING CHAMBER
COVER MAY VARY
12"-36"
24" LOCKING GAS TIGHT MANHOLE
COVER. FASTEN WITH FOUR SCREWS
PER LID. USE #3 SQUARE DRIVE OR
LARGER.
PVC RISER TO BRING ELEVATION TO THE
SURFACE. ALL JOINTS TO BE SEALED WITH
MASTIC (TYP.)SLOPE TO DRAIN
PVC RISER TO BRING ELEVATION TO THE
SURFACE. ALL JOINTS TO BE SEALED WITH
MASTIC (TYP.)
BALL CHECK VALVE
UNION
DISCHARGE
FLOAT TREE
ON/OFF FLOAT
HIGH LEVEL ALARM FLOAT
REDUNDANT OFF FLOAT
4"∅ PVC @ 2.00% MIN.
I.E.= ± 74.75'
COMMERCIAL GRADE
FILTER ACCESSIBLE
THROUGH MANHOLE.
I.E.= ± 74.50'
CORROSION AND EXPLOSION PROOF
NEMA 4X AND 7 NON-METALLIC
JUNCTION BOX
INLET TEE LIQUID LEVEL CONTROLS
GASKETED CHAMBER LID WITH HOLD
DOWN BOLTS OR SCREWS
DISCHARGE
GAS SEAL END OF CONDUIT
TO CONTROL PANEL
SEE DOSING
CHAMBER
SECTION VIEW
PLAN VIEW
1/3 TOTAL
VOLUME
LIFT CHAIN
SCHEMATIC
NATIVE SOIL BACKFILL FREE OF ROCKS
>3" (TYP.). SEE NOTES ABOVE FOR
COMPACTION
4"-6" MIN. MEDIUM SAND (TYP.)
SEE NOTES ABOVE FOR COMPACTION
6"
MIN.18"18"
6"
MIN.
TANK NOTES:
1.CONTROL POINT: NW PROP CORNER
ELEVATION= ± 78'
2.STUB OUT I.E.= ± 76'
3.DRAIN FIELD MANIFOLD INLET ELEVATION= ± 76'
4.PROVIDE AT LEAST ONE CLEAN OUT BETWEEN THE STUB OUT AND THE SEPTIC TANK INLET.
5.FOLLOW TANK MANUFACTURERS INSTALLATION INSTRUCTIONS.
6.TANK EXCAVATION SHALL BE LEVEL AND COMPACTED PRIOR TO PLACING BEDDING.
7.PROVIDE 4"-6" OF LEVEL MEDIUM SAND BEDDING BENEATH TANKS. COMPACT TO 95%.
8.PROVIDE NATIVE SOIL BACKFILL FREE OF ROCKS >3" AS BACKFILL AROUND TANKS. MAXIMUM 10"
LIFTS AND COMPACT TO 95%.
9.LOWER 18" OF COVER OVER TOP OF TANKS SHALL BE NATIVE SOIL BACKFILL FREE OF ROCKS >3".
MAXIMUM 10" LIFTS. COMPACT TO 95%.
10.ALL TANKS SHALL BE ADEQUATELY VENTED. VENTING MAY BE ACCOMPLISHED BY CONNECTION TO
BUILDING SEWER VENTS OR BY A DIRECT TWO-INCH MINIMUM VERTICAL VENT TO THE ATMOSPHERE.
13.ALL JOINTS TO BE SEALED WATER TIGHT WITH MASTIC.
14.ALL TANKS SHALL BE TESTED & CONFIRMED WATERTIGHT.
4004 NE 4TH ST., #107-508
RENTON, WA 98056
425.457.6029
425.432.4461 FAX
WI
L
L
I
A
M
S
R
E
S
I
D
E
N
C
E
ON
-
S
I
T
E
S
E
W
A
G
E
D
I
S
P
O
S
A
L
D
E
S
I
G
N
13
4
1
1
S
E
1
5
1
S
T
S
T
R
E
E
T
R
E
N
T
O
N
KI
N
G
C
O
U
N
T
Y
2" MIN. ABOVE PUMP
SLOPE TO DRAIN
750 GALLONS
(ONE DAY RESERVE)
OUTLET
PUMP OFF LEVEL
31.25 GALLON DOSE VOLUME
PUMP ON LEVEL
SURGE VOLUME 300 GALLONS
ALARM LEVEL
PUMP
5 MIN.
FLOAT TREE
REDUNDANT OFF FLOAT
ON/OFF FLOAT
HIGH LEVEL ALARM FLOAT
INLET TEE
ACCESSIBLE CONTROL PANEL WITH VISUAL/AUDIBLE ALARM ON
SEPARATE CIRCUITS. PANEL TO BE INSTALLED IN DIRECT LINE OF SIGHT
OF THE DOSING CHAMBER.
36" MAX.
ORENCO PVC MANHOLE
RISERS OR EQUIVALENT
24"∅ RISERS
3" BRICKS
GAS SEALED CONTROL CIRCUIT
CONDUIT TO CONTROL PANEL.
INTRINSICALLY SAFE WIRING ONLY.
NTSSCHEMATIC
DOSING CHAMBER
2'
M
I
N
.
DOSING CHAMBER
SECTION VIEW
DOSING CHAMBER NOTES:
1.ALL INTERNAL TANK PIPING SHALL BE SCHEDULE 40 PVC OR BETTER. FITTINGS SHALL BE SCHEDULE 80
OR BETTER.
2.CONTROL-ALARM PANEL SHALL BE OUTDOOR APPROVED OR WEATHER PROTECTED, READILY ACCESSIBLE,
TAMPER RESISTANT, AND IN DIRECT LINE OF SIGHT OF THE DOSING CHAMBER.
3.ALL ELECTRICAL WORK TO THE CONTROL PANEL MUST BE COMPLETED PRIOR TO FINAL INSPECTION. THE
SYSTEM SHALL BE TESTED USING PERMANENT POWER.
4.USE GEOFLOW 1-ZONE SIMPLEX AUTOMATIC CONTROL PANEL WITH TIMER AND AUTOMATIC FLUSHING
WITH SJE RHOMBUS SENSOR FLOAT MERCURY FLOATS OR EQUAL.
5.PANEL SHALL HAVE AN EVENT COUNTER, HOUR RUN METER, AND VISUAL/AUDIBLE ALARM. THE ALARM
CIRCUIT SHALL BE INDEPENDENT OF THE PUMP CIRCUIT.
6.MOUNT THE CONTROL PANEL ON A NON-BEDROOM EXTERIOR WALL OR ON ITS OWN PEDESTAL
APPROXIMATELY FIVE FEET HIGH ABOVE FINAL GRADE.
7.A TIMER SHALL BE USED IN CONJUNCTION WITH THE ON/OFF FLOAT TO TURN THE PUMP ON EVERY 1
HOUR FOR 0.4 MINUTES. ACTUAL RUN TIME SHALL BE SET BY TESTING AS PER NOTE 8.
8.AT THE PRESSURE TEST THE INSTALLER SHALL VERIFY THE PUMP RUN TIME. THE PUMP RUN TIME SHALL
PROVIDE A DOSE OF 31.25 GALLONS. THE TIMER SHALL THEN BE SET FOR THIS PUMP RUN TIME.
9.THE FOLLOWING CONDITIONS SHALL BE MET IN ORDER FOR THE PUMP TO TURN ON:
A. THE ON/OFF FLOAT IS IN THE ON POSITION.
B. THE TIMER IS IN THE ON CYCLE.
10.PUMP IS AN GOULDS MODEL WE20H OR EQUIVALENT SUBMERSIBLE EFFLUENT PUMP THAT PROVIDES 75
GPM AT 55 FEET OF HEAD.
11.THIS DESIGN INCLUDES 10 FEET OF ELEVATION HEAD FROM THE PUMP TO THE DRAIN FIELD AND 30
LINEAL FEET OF TRANSPORT PIPE. EXCEEDING THESE NUMBERS WILL REQUIRE RESIZING THE PUMP.
12.THE PUMP IS INSIDE AN ORENCO BIOTUBE PUMP VAULT OR EQUIVALENT.
13.FLOATS/ PUMP CONTROL SWITCHES SHALL BE MOUNTED INDEPENDENT OF THE PUMP AND TRANSPORT
LINE.
14.ALL PUMP CONTROL STRAPS SHALL BE MADE OF POLYPROPYLENE OR OTHER MATERIAL APPROVED FOR
USE IN SEPTIC SYSTEMS.
15.THE SYSTEM SHALL BE EQUIPPED WITH AN AIR VACUUM RELEASE VALVE OR OTHER SUITABLE DEVICE TO
AVOID SIPHONING.
4004 NE 4TH ST., #107-508
RENTON, WA 98056
425.457.6029
425.432.4461 FAX
WI
L
L
I
A
M
S
R
E
S
I
D
E
N
C
E
ON
-
S
I
T
E
S
E
W
A
G
E
D
I
S
P
O
S
A
L
D
E
S
I
G
N
13
4
1
1
S
E
1
5
1
S
T
S
T
R
E
E
T
R
E
N
T
O
N
KI
N
G
C
O
U
N
T
Y
24" SAND SHOULDER
6" SAND SHOULDER
2.0
3' TYPICAL
10'
2.0
37.5'
3 LATERALS TOTAL
3"∅ CLASS 200 PVC
TRANSPORT PIPE FROM
DOSING CHAMBER
1-1/4"∅ PERFORATED CLASS 200 PVC LATERAL
DRILL 3/16"∅ HOLES UPWARD
AT END CAP OF EACH LATERAL
NTS
MANIFOLD/LATERAL LAYOUT
SCHEMATIC
3/16"∅ HOLE
S
P
L
A
C
E
D
O
N
T
O
P
O
F
LATER
A
L
2
1
"
O
N
C
E
N
T
E
R
3
'
M
I
N
.
9"
24"
VOID SPACE
INSTALL CLEANOUTS ON ALL LATERALS
NTS
SAND BED
3 LATERALS TOTAL
NTS
SAND BED CROSS SECTION
WITH INFILTRATORS
1.MINIMUM DEPTH OF SAND UNDER BED SHALL BE TWO FEET.
2.SAND BED AND PRESSURE LATERALS SHALL BE LEVEL AND FOLLOW ORIGINAL GROUND CONTOURS.
3.PROVIDE ADEQUATE DRAINAGE AROUND SAND BED.
4.EXCAVATED LOAMY SAND MATERIAL FROM SAND BED AREA MAY BE STOCKPILED FOR SUBSOIL CAP.
5.SAND BED SHALL BE INSTALLED PER THE LATEST EDITION OF THE WASHINGTON STATE DEPARTMENT OF
HEALTH SAND LINED TRENCH SYSTEM GUIDELINES.
6.OPERATION AND MAINTENANCE MONITORING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF
THE WASHINGTON STATE DEPARTMENT OF HEALTH SAND LINED TRENCH SYSTEM GUIDELINES.
SAND BED NOTES
3"∅ TRANSPORT PIPE
CLEANOUT
TYP.
MONITORING PORT
COVER AS MANUFACTURED BY
CARSON INDUSTRIES MODEL 910-12B
OR EQUAL
INSTALL TWO 4"∅ PVC
AERATION PORTS
4"∅ PVC MONITORING PORTS WITH SOLID
CAPS, BOTTOM 9" PERFORATED WITH 1/2"
HOLES 3' O.C. (TYP.)
FILTER FABRIC
FINISHED GRADE ORIGINAL GRADE
SLOPE TO DRAIN
3/8" - 1 1/2" CLEAN WASHED
COARSE AGGREGATE NO FINES OR
SILT ALLOWED
CLEAN SANDY
LOAM FILL
COARSE SAND
3" OF PEA GRAVEL
1-1/4" LATERAL
VOID SPACE VOID SPACE
MANIFOLD
36" MIN
51" MAX
INFILTRATOR QUICK4
STANDARD CHAMBER
21"
21"
75'
4004 NE 4TH ST., #107-508
RENTON, WA 98056
425.457.6029
425.432.4461 FAX
WI
L
L
I
A
M
S
R
E
S
I
D
E
N
C
E
ON
-
S
I
T
E
S
E
W
A
G
E
D
I
S
P
O
S
A
L
D
E
S
I
G
N
13
4
1
1
S
E
1
5
1
S
T
S
T
R
E
E
T
R
E
N
T
O
N
KI
N
G
C
O
U
N
T
Y