Loading...
HomeMy WebLinkAboutR-421015O N O W H w Q w DocuSign Envelope ID: 3B1 B34D3-7EOA-476C-ADB3-4329FFEOC108 (1) OPEN PICKHOL PLAN VIEW +.. rL/A I rAl.t hV I rl1U 9" DIA I 4" 8 13/16" DIA 8-1/8" DIA l 10-112" DIA —L (2) 3/8"-16 SS SOCKET HEAD CAP 15" DIA SCREW (ALLENHEAD) W/WSHRS 5/8 ON A 8" DIA BOLT CIRCLE FRAME SECTION COVER SECTION CAST IRON FRAME AND COVER, SEE NOTE 3 — 8" CLASS "B" ASPHALT, SEE NOTE 4 \\ CLEANOUT RISER. SEE NOTE 2 SOIL TIGHT 45' BEND WYE SOIL TIGHT COUPLER UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE. SEE NOTE 1 TO OVERFLOW STRUCTURE OR STORM MAIN u�Trc. PAVED AREA (TYP.) 121' EXTEND CLEANOUT RISER DESIGN I�{I 2" ABOVE DESIGNSIGN PONDING ELEVATION OR PER PLAN FERNCO GASKETED DESIGN PONDING QUIK CAP OR SIMILAR OR a ELEVATION 4" STREAMBED COBBLES j x j x x j��j/` PER WSDOT 9 03.11(2) Y/4X 4" COMPACTED SAND OR �/ GRAVEL BACKFILL FOR DRAINS ��. PER WSDOT 9-03.12(4) y,,�. 15]d 1 1=1 I I=1 I =1 I Md 11-1 11— I—I 15—d I 1=1 =111-I I I_, 1111 CLEANOUT RISER, -1 11= SEE NOTE 2 I I� MECHANICAL PLUG OR CONTINUED CONNECTION TYPICAL CLEANOUT CONFIGURATION CLEANOUT RISER LOCATED WITHIN BIORETENTION PONDING AREA 1. DIAMETER TO BE 6-INCHES MINIMUM PRIVATE, 8-INCHES MINIMUM PUBLIC. UNDERDRAIN PIPE PER STD. PLAN 262.10. 2. CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE. 3. FRAME AND COVER SHALL BE EJ PRODUCTS 3675Z1 PT AND 3675APT OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "STORM" OR "DRAIN". 4. FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BIORETENTION PONDING AREA, POUR 8" THICK, 2'x2' SQUARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI. GENERAL NOTES: 1. CLEANOUTS FOR UNDERDRAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERDRAIN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 2. ALL FITTINGS SHALL BE SOIL TIGHT. 3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF BIORETENTION PONDING WHERE POSSIBLE. 4. CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 226.00 �ROSf�hed by: PUBLIC WORKS STORM SYSTEM CLEANOUT 8/13/20 ;lqRDEPARTMENT artin Pastucha • m P%k A Wja4 9D... DATE 110 DocuSign Envelope ID: 3B1 B34D3-7EOA-476C-ADB3-4329FFEOC108 SEE NOTE 2 10' MIN. 5' MIN. D PERFORATED PIPE TO BE LEVEL CLEANOUT PER STD. PLAN 226.00 2' MIN. _L PgFw 3/4" TO 1-112" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD SPECIFICATION SECTION 9-03.12(5) YARD DRAIN OR CATCH BASIN WITH SOLID LID ROOF DOWNSPOUT WITH OVERFLOW WYE AND SPLASH BLOCK FLEXIBLE GASKETED CAP PER ASTM D5926 6" MIN. F- 6" MIN. 6" DIA. MIN. PERFORATED PVC, •\ SDR 35 PER ASTM D3034 ER ELEVATION 6" MIN., 6" MIN. VA 12" MIN. 12" MIN. ABOVE SEASONAL HIGH ��\ �'/,24' MIN. GROUNDWATER OR HYDRAULICALLY I_ RESTRICTIVE LAYER 7-7 SECTION A I\If1T IC C. COMPACTED BACKFILL LINER 12" 12" HOUSE HOUSE 6" DIA. MIN. PVC. SDR 35 PER ASTM D3034 FINE MESH SCREEN. SS304 10x10 OR SIMILAR 6" DIA. MIN. PERFORATED PVC, SDR 35 PER ASTM D3034 NON -WOVEN GEOTEXTILE FOR SEPARATION ON TOP AND SIDES OF TRENCH PER WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 1. 15' MINIMUM SETBACK FROM INFILTRATION TRENCH TO BUILDINGS WITH CRAWL SPACES, BASEMENTS, OR ELEVATIONS BELOW THE OVERFLOW POINT. 2. REQUIRED TRENCH LENGTH VARIES DEPENDING ON SOIL TYPE, UP TO 100' MAX. WHEN LOCATED IN COARSE SANDS OR COBBLES, INFILTRATION TRENCHES MUST BE AT LEAST 20' IN LENGTH PER 1,000 SQUARE FEET OF IMPERVIOUS SURFACE SERVED. WHEN LOCATED IN MEDIUM SANDS, INFILTRATION TRENCHES MUST BE AT LEAST 30' IN LENGTH PER 1,000 SQUARE FEET OF IMPERVIOUS SURFACE SERVED. 3. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 225.20 ,c PUBLIC WORKS SINGLE FAMILY ROOF DOWNSPOUT I31gOSC�,edby: ��� DEPARTMENT INFILTRATION TRENCH artin Pastucha s/13/202 • " j%ft�Q44,9D... DATE R-421014 IN COMPLIANCE WITH CITY OF RENTON STANDARDS WASTEWATER UTILITY jstowe1104/24/2023 01 DEVELOPMENT ENGINEERING yq i 04/21 /2023 :01 f �G SURVEYED: SCALE: DATE: VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 CITY O F 3/28/2023 y` DESIGNED: DRAWN: R E N TO N TRAN-NGUYEN DEVELOPMENT FPIGDBOOK: ONE INCH • DRAWING NO: Pannin E�60 CHECKED: AT FULL SCALE DATUM g/ Buildin g/Public Works Dept. DRAINAGE DETAILS PLAN C-21.0 CHECKED: S / �M 0S•�L ` N0. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY SHEET: 21 oE: 29 3/ 6/2023 N O 0 a.