HomeMy WebLinkAboutW-4210020 Irl N d_ J a PROPOSED 185' WATERMAIN 270 1-10"X6" TEE (MJXFL) 1-6" GATE VALVE (FLXMJ) 1- FIRE HYDRANT ASSEMBLY COR. STD. PLAN 310.1 1-CONC THRUST BLOCK 260 L- 1" WATER SERVICE 200 AND METER (TYP) 2.4' FINISHED ACCESS ROAD GRADE 6" D.I. SIDE SEWER MIN. 4' COVER MAX. 6' COVER PROPOSED 185.0', 10" D.I. CL. 50 WATER MAIN CONTRACTOR SHALL PROVIDE VERTICAL BEND AS NEEDED. VERIFY THE PIPE DEFLECTION DOES NOT EXCEED 112 OF MANUFACTOURERS'S MAXIMUM ALLOWED JOINT DEFLECTION EXISTING/ - 8" SEWER 12" STORM WATER PIPE - �" 1 -- l WATER PLAN GENERAL NOTES Standard Plan No. 300 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL 280 CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION. 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND "CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON -SITE. 0 0 0 0 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C N o 104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS w > PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 270 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10-INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. CONNECTED TO EXISTING 16" WATER MAIN ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR CONTRACTOR SHALL FIELD VERIFY ' THE EXISTING WATER MAIN ELEVATION THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. MINIMUM 1.5' REQUIRE SEPARATION SHALL BE PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH MAINTAINED FOR PROPOSED STORM AND BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST SEWER. IF THE SEPARATION CANNOT BE METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED MAINTAINED, ETHAFOAM SPACING OR APPROVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. EQUIVALENT SHALL BE PROVIDED. --EXISTING 12" SEWER 260 100 0 CONTRACTOR SHALL FIELD VERIFY THE EXISTING 6IA. 1+15.20 0.0' SEE COR STD.320.1 INSTALL 10" POLY PIGGING STATION SEWER AND STORM ELEVATION, WHICH SHALL BE PER COR STD. PLAN 300.7 STA. 1+62.50 15.0' RT VERTICAL: 1"=4' 1.5' VERTICAL SEPARATION BETWEEN THE OUTSIDE WITH 10" VERTIAL CROSS (MJXFL) 6" FIRE HYDRANT HORIZONTAL: 1"=20 EDGE TO OUTSIDE EDGE OF THE PIPES. PLUG (MJ) AND CONICBLOCKING PER COR STD. PLAN 310.1 ON WEST END OF CROSS. 15' PUBLIC WATER MAIN EASEMENT a I \ S 1� -'r-� -' $ - _S S = - S - = 5 -= $ -_ - - = _S - ~ _5 = = `e100 r - - _ - - - - - - - - - -, - - - - l ♦' T.S-_= _ �$ - . 5. = e. -. 5. - -5- 5 � - S - _ - - S - = $ - _ $ -_ = S-= = S ibMl �2/3.24 3.15* 1 + 0 I e - - - - - - N89°0_52E 252.62' \\\ 273.5 II 3.4 s I ie II 282 r----------- I I W I ° I� I W I "; =. =--- IIII r - �: 11 -.--.- :--- -=-- 1 +00 :-----.-----�� I °: ° f I O. 0. I . vv 1.85.0' .I: CL, 50: ATER MAIN ° . II I ° I I I - _---------r°a> I D CO I I I _J m m cn I I I 280.62 20 coo l G. ICO Nl I r-- b O I a STA. 1 +38.82 (10.0' RT) CONNECTED TO EXSITING PIPE CONNECTED BY COR STAFFS 16"X10" TAPPING TEE, (MJXFL) 10" GATE VALVE (FLxMJ) CONCRETE BLOCK SEE COR STD. 300.1 co ----- -----� I I 1-10"X 6" TEE (MJXMJ) CO ( BSBL BSBL \ 0 1 i �. I 1- 6" GATE VALVE (FLxMJ) BSBL 5' \ 1 I 1 FIRE HYDRANT ASSEMBLY PER � Z 1 "} - I I COR. STD. PLAN 310.1 1" WATER SERVICE \ I� L_I 1 �' 1- CONC.THRUST BLOCK 4 o I AND METER TYP \ I I I. 1 I 12 I ti I SEE COR STD. 320.1 \ 20' BSB o o I I Q I.. I I vz co W.l L. I eie I I I 61.5'I G. a. wo {.. LOT A 279.86 I I I I 2 2 I> I I I I I LOT C I I I Im / I 13.60' BSB q Q I I a 70'Lu ,lie b I J I I I I �.. Q 2b I I81 I I l2 8 LOT B// I I I 276 65 I I I I -I I 2 4 o L ----- d ie ---------- J _ I I I c 279.1 I I I I co ie m l' _ 27 .96 I w.. l =Fms \ � m I � -- A. /y4 00 -°.�sF I U o 80 4�s L5a I C �� \V � I r� 271.4 71 826' III t 9_ 10 9 I I. I \ 81P 2�^ \ \ \ 252.60' S89°10'27"W 270.73 27113 N \ , �� P CD \ EXISTING rn I rn LEGEND \ \ \ \ \ GRAVEL DRIVEWAY - PROPOSED WATER LINE EXISTING WATER LINE PROPOSED SEWER LINE EXISTING SEWER LINE 15' PUBLIC WATER MAIN EASEMENT 20 10 0 20 40 SCALE IN FEET STA. 0+20.72 (18.0' LT) 6" FIRE HYDRANT PER COR STD. PLAN 310.1 6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS (OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITYTESTING. 8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION. NOTE: ALL MECHANICAL JOINT FITTINGS AND VALVES SHALL HAVE MEGALUG RETAINER GLANDS SERIES 1100 IN ADDITION TO CONCRETE THRUST BLOCKS. W-421002 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/11 /2024 O MIS; ;► �' SURVEYED: SCALE: DATE: •���p,/" G VERTICAL: NAVD 1988 $ $ $ $ - � �� • HORIZONTAL: NAD 1983/1991 CITY OF 3/28/2023 DESIGNED: O -S--S--S--S- y = TRAN-NGUYEN DEVELOPMENT PGEBOOK: DRAWN: RENTON y ONE INCH DATUM DRAWING NO: 0�, Ifs=�tf�� CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. WATER PLAN C-9.0 �,• IF NOT ONE INCH $/ONAL NO, REVISION BY DATE APPR APPROVED: SHEET: 9 OF: 29 1 /01 /2024 SCALE ACCORDINGLY 7