NOTES:
1. PLACE CONSTRUCTION GEOTEXTILE FOR SOIL STABILIZATION AND A
MINIMUM OF 0.15' CRUSHED ROCK UNDER THE SPALLS, FROM THE
EDGE OF THE EXISTING ROADWAY TO THE RADIUS RETURNS, OR
AS DIRECTED BY THE ENGINEER.
EXISTING ROAD
INSTALL DRIVEWAY CULVERT IF 2. IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT
THERE IS A ROADSIDE DITCH RUNOFF DRAINS OFF THE PAD.
PRESENT AS PER CITY OF
RENTON ROAD STANDARDS
12 FEDAID: STPUL-1276(004)
HPP-1276(005)
T SOME DATA ON RECORD DRAWINGS
IS BASED UPON INFORMATION
PROVIDED BY THE CONSTRUCTION
in CONTRACTOR TO THE CITY OF
.. RENTON, THE CORRECTNESS TO THIS
DATA HAS NOT BEEN VERIFIED.
25' MIN. RADIUS (TYP)
SEE NOTE 1
4"-8" QUARRY SPALLS
RADIUS
RETURN (TYP)
/00•
12" MIN
THICKNESS S�
PROVIDE FULL WIDTH OF
INGRESS / EGRESS AREA
STABILIZED CONSTRUCTION ENTERANCE
TE-12 SCALE: NTS
5" MAX.
DRAINAGE GRATE /—TRIM GEOTEXTILE
GRATE FRAME
SEDIMENT AND DEBRIS
JOINTS IN FILTER FABRIC SHALL BE SPLICED
AT POSTS. USE STAPLES, WIRE RINGS, OR
EQUIVALENT TO ATTACH FABRIC TO POSTS.
2" x 2" BY 14 Go. WIRE OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
IIn
I FILTER FABRIC
II I Z
II I N
I I I
II I
I I MINIMUM 4"x4" TRENCH
LJ L BACKFILL TRENCH WITH NATIVE SOIL
6' MAX OR 3/4"-1.5" WASHED GRAVEL
r
2" x 4" WOOD POSTS,
STEEL FENCE POSTS,
REBAR, OR EQUIVALENT
ELEVATION VIEW SECTION VIEW
3 SILT FENCE
TE-12 SCALE: NTS
SECTION VIEW
OVERFLOW BYPASS
BELOW INLET GRATE DEVICE
FILTER WATER
DRAINAGE GRATE
(RECTANGULAR GRATE
SHOWN)
BELOW INLET GRATE DEVICE
(Z INLET PROTECTION
TE-12 SCALE: NTS
IArail rK�419
1. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORM
WATER STRUCTURE IT WILL SERVICE.
2. THE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM
(OVERFLOW BYPASS).
3. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD
WITHOUT SPILLING THE COLLECTED MATERIAL.
4. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD
SPECIFICATION 8-01.3(15).
RETRIEVAL SYSTEM (TYP)
OVERFLOW BYPASS (TYP)
ISOMETRIC VIEW
NOTES:
1. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOUR WHENEVER POSSIBLE.
2. THE FENCE POST SHALL BE SPACED A MAXIMUM OF 6-FT APART AND DRIVEN SECURELY
INTO THE GROUND (MIN. 1-FT). POST SPACING MAY BE INCREASED TO 8-FT O.C. IF WIRE
BACKING IS USED.
3. THE FILTER FABRIC (CONSTRUCTION GEOTEXTILE FOR TEMPORARY SILT FENCE) SHALL BE
PURCHASED IN A CONTINUOUS ROLL CUT TO LENGTH OF THE BARRIER TO AVOID USE OF
JOINTS. WHEN JOINTS ARE NECESSARY, THE FILTER FABRIC SHALL BE SPLICED TOGETHER
ONLY AT A SUPPORT POST, WITH A MINIMUM 6-INCH OVERLAP, AND BOTH ENDS SECURELY
FASTENED TO THE POST.
4. A TRENCH SHALL BE EXCAVATED, A MINIMUM OF 4-IN WIDE BY 4-IN DEEP, UPSLOPE AND
ADJACENT TO THE POST TO ALLOW THE FILTER FABRIC TO BE BURIED.
5. WHEN STANDARD STRENGTH (LOW SURVIVABILITY) FILTER FABRIC IS USED, A 2-IN BY 2-IN
BY 14-GAUGE WIRE MESH SUPPORT FENCE SHALL BE FASTENED SECURELY TO THE
UPSLOPE SIDE OF THE POST USING HEAVY-DUTY WIRE STAPLES AT LEAST I -INCH LONG,
TIE WIRES, OR HOG RINGS. THE WIRE SHALL EXTEND INTO THE TRENCH A MINIMUM OF
4-IN AND SHALL NOT EXTEND MORE THAT 3-FT ABOVE THE ORIGINAL GROUND.
6. STANDARD STRENGTH FILTER FABRIC SHALL BE STAPLED OR WIRED TO THE POSTS, AND
1-FT 8-IN OF THE FABRIC SHALL BE EXTENDED INTO THE TRENCH. THE FABRIC SHALL
NOT EXTEND MORE THAN 3-FT ABOVE THE ORIGINAL GROUND SURFACE. FILTER FABRIC
SHALL NOT BE STAPLED INTO TREES.
7. THE TRENCH SHALL BE BACKFILLED WITH NATIVE MATERIAL OR 3/4-IN TO 3/2-IN WASHED
GRAVEL.
8. FILTER FABRIC FENCES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL
PURPOSE, BUT NOT BEFORE THE UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED.
9. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15).
BergerABAM RECORD AS SHOWN CITY OF
RENTON
DRAWING BEE Public Works Department
DATUM
33301 9th Avenue South, Suite 300 EKK Approved For Construction
Federal Way, Washington 98003-2600 NAS
(206) 431-2300 Fax: (206) 431-2250 NO. REVISION BY DATE APPR _ I —
Rohert M. Hanson P.F. f
STRANDER BOULEVARD EXTENSION
PHASE 1, SEGMENT 2A
SITE PREP AND TEMP EROSION CONTROL DETAILS