Loading...
HomeMy WebLinkAboutR-3693048C'7 C7� CD CY) O LLI I— a� Ir a O NOTES: 1. PLACE CONSTRUCTION GEOTEXTILE FOR SOIL STABILIZATION AND A MINIMUM OF 0.15' CRUSHED ROCK UNDER THE SPALLS, FROM THE EDGE OF THE EXISTING ROADWAY TO THE RADIUS RETURNS, OR AS DIRECTED BY THE ENGINEER. EXISTING ROAD INSTALL DRIVEWAY CULVERT IF 2. IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT THERE IS A ROADSIDE DITCH RUNOFF DRAINS OFF THE PAD. PRESENT AS PER CITY OF RENTON ROAD STANDARDS 12 FEDAID: STPUL-1276(004) HPP-1276(005) T SOME DATA ON RECORD DRAWINGS IS BASED UPON INFORMATION PROVIDED BY THE CONSTRUCTION in CONTRACTOR TO THE CITY OF .. RENTON, THE CORRECTNESS TO THIS DATA HAS NOT BEEN VERIFIED. 25' MIN. RADIUS (TYP) SEE NOTE 1 4"-8" QUARRY SPALLS RADIUS RETURN (TYP) /00• 12" MIN THICKNESS S� PROVIDE FULL WIDTH OF INGRESS / EGRESS AREA STABILIZED CONSTRUCTION ENTERANCE TE-12 SCALE: NTS 5" MAX. DRAINAGE GRATE /—TRIM GEOTEXTILE GRATE FRAME SEDIMENT AND DEBRIS JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC TO POSTS. 2" x 2" BY 14 Go. WIRE OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED IIn I FILTER FABRIC II I Z II I N I I I II I I I MINIMUM 4"x4" TRENCH LJ L BACKFILL TRENCH WITH NATIVE SOIL 6' MAX OR 3/4"-1.5" WASHED GRAVEL r 2" x 4" WOOD POSTS, STEEL FENCE POSTS, REBAR, OR EQUIVALENT ELEVATION VIEW SECTION VIEW 3 SILT FENCE TE-12 SCALE: NTS SECTION VIEW OVERFLOW BYPASS BELOW INLET GRATE DEVICE FILTER WATER DRAINAGE GRATE (RECTANGULAR GRATE SHOWN) BELOW INLET GRATE DEVICE (Z INLET PROTECTION TE-12 SCALE: NTS IArail rK�419 1. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORM WATER STRUCTURE IT WILL SERVICE. 2. THE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS). 3. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 4. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15). RETRIEVAL SYSTEM (TYP) OVERFLOW BYPASS (TYP) ISOMETRIC VIEW NOTES: 1. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOUR WHENEVER POSSIBLE. 2. THE FENCE POST SHALL BE SPACED A MAXIMUM OF 6-FT APART AND DRIVEN SECURELY INTO THE GROUND (MIN. 1-FT). POST SPACING MAY BE INCREASED TO 8-FT O.C. IF WIRE BACKING IS USED. 3. THE FILTER FABRIC (CONSTRUCTION GEOTEXTILE FOR TEMPORARY SILT FENCE) SHALL BE PURCHASED IN A CONTINUOUS ROLL CUT TO LENGTH OF THE BARRIER TO AVOID USE OF JOINTS. WHEN JOINTS ARE NECESSARY, THE FILTER FABRIC SHALL BE SPLICED TOGETHER ONLY AT A SUPPORT POST, WITH A MINIMUM 6-INCH OVERLAP, AND BOTH ENDS SECURELY FASTENED TO THE POST. 4. A TRENCH SHALL BE EXCAVATED, A MINIMUM OF 4-IN WIDE BY 4-IN DEEP, UPSLOPE AND ADJACENT TO THE POST TO ALLOW THE FILTER FABRIC TO BE BURIED. 5. WHEN STANDARD STRENGTH (LOW SURVIVABILITY) FILTER FABRIC IS USED, A 2-IN BY 2-IN BY 14-GAUGE WIRE MESH SUPPORT FENCE SHALL BE FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POST USING HEAVY-DUTY WIRE STAPLES AT LEAST I -INCH LONG, TIE WIRES, OR HOG RINGS. THE WIRE SHALL EXTEND INTO THE TRENCH A MINIMUM OF 4-IN AND SHALL NOT EXTEND MORE THAT 3-FT ABOVE THE ORIGINAL GROUND. 6. STANDARD STRENGTH FILTER FABRIC SHALL BE STAPLED OR WIRED TO THE POSTS, AND 1-FT 8-IN OF THE FABRIC SHALL BE EXTENDED INTO THE TRENCH. THE FABRIC SHALL NOT EXTEND MORE THAN 3-FT ABOVE THE ORIGINAL GROUND SURFACE. FILTER FABRIC SHALL NOT BE STAPLED INTO TREES. 7. THE TRENCH SHALL BE BACKFILLED WITH NATIVE MATERIAL OR 3/4-IN TO 3/2-IN WASHED GRAVEL. 8. FILTER FABRIC FENCES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT BEFORE THE UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED. 9. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15). BergerABAM RECORD AS SHOWN CITY OF RENTON DRAWING BEE Public Works Department DATUM 33301 9th Avenue South, Suite 300 EKK Approved For Construction Federal Way, Washington 98003-2600 NAS (206) 431-2300 Fax: (206) 431-2250 NO. REVISION BY DATE APPR _ I — Rohert M. Hanson P.F. f STRANDER BOULEVARD EXTENSION PHASE 1, SEGMENT 2A SITE PREP AND TEMP EROSION CONTROL DETAILS