HomeMy WebLinkAboutR-3693104(y) Cy) (D M r) LLI R ONE -LINE DIAGRAM SYMBOLS PANELBOARDS, SWITCHES,_AND EQUIPMENT -" --- "- -": CIRCUIT BREAKER SERVICE ENTRANCE, SWITCHGEAR, XXX/a - CS SIZE & NO. OF POLES - - MOTOR CONTROL CENTER. OR ET - ELECTRONIC TRIP PANEIBOARD TM - THERMAL MAGNETIC BREAKER MCP - MDTOR CIRCUIT PROTECTOR SE - SERVICE ENTRANCE SURFACE MOUNTED PANEBOARD OR - GROUND FAULT INTERRUPTER - FUSE —moo FUSED DISCONNECT SWITCH ��--- PLUG-IN CONNECTION_ FLUSHED MOUNTED PANELBOARD RTM RUN TIME METER OC MOTOR OPERATION COUNTER N`X ❑e FIELD CONTROL STATION WITH NEMA REQUIREMENTS. N1 - NEMA I N3R - NEMA 3R SSRVS N4 -NEMA 4 N4SS - NEMA 4 STAINLESS STEEI * t SSRVS - SOLID STATE N6 - NEMA 4 FIBERGLASS I REDUCED VOLTAGE STARTER N6 -NEMA 6 N12 - NEMA 12 GASKETED VARIABLE FREQUENCY DRIVE EQUIPMENT MOUNTING STAND ® MOTOR STARTER ELI HEATER, WATTAGE NOTED A B MOTOR STARTER W/ OPERATOR C D DEVICE' ® EQUIPMENT CONNECTION A - HAND -OFF -AUTO B - OPERATIONAL COUNTER C - RUN TIME METER SINGLE PHASE MOTOR. D - RUN EIGHT M HORSEPOWER AS NOTED E - FAIL LIGHT F - EMERGENCY STOP O KIRK KEY INTERLOCK 100 THREE PHASE MOTOR. HORSEPOWER AS NOTED nni5 POWER TRANSFORMER nn CONTROL POWER TRANSFORMER Hp SINGLE PHASE MOTOR. HORSEPOWER AS NOTED 4 TRANSFORMER ' CURRENT TRANSFORMER VOLTAGE TRANSFORMER CONTACTOR T CAPACITOR T ENGINE GENERATOR GENERATOR CONNECTION ® RECEPTACLE N SOLID NEUTRAL OTERMINAL BLOCK SURGE PROTECTION DEVICE SPD SURGE PROTECTION DEVICE 0 0 (ALTERNATIVE) GROUND I I I I METAL PIPE GROUND ---FJ CONNECTION POINT, EXOTHERMIC WELD. CADWELD OR APPROVED EQUAL GROUND ROD SIZED PER N.E.C. USE 6 O EXOTHERMIC WELD CONNECTION AT THE GROUND ROD. 1 PIGTAIL. BARE COPPER, LENGTH AS REWIRED, B' MINIMUM. q _ CONNECTION POINT, MECHANICAL, m COMPRESSION TYPE. FEDAID: CALL 48 HOURS N BEFORE YOU DIG 1-800-424-5555 T ELECTRICAL PLUG DISCONNECT SYATCH L r 1 FUSED DISCONNECT SWITCH COMBINATION MOTOR STARTER AND DISCONNECT SWITCH QJ CEILING JUNCTION BOX WALL JUNCTION BOX �j FLOOR JUNCTION BOX DUPLEX WALL RECEPTACLE , 120V WP = WEATHERPROOF G = GROUNDED IG = ISOLATED GROUND GF - GROUND FAULT INTERRUPTER DOUBLE DUPLEX SINGLE RECEPTACLE, 120V b SINGLE RECEPTACLE, 208V ® DUPLE! FLOOR RECEPTACLE, 120V IAO SPECIAL PURPOSE WALL RECEPTACLE, I �10 RATING AS NOTED 0 [0 CLOCK N❑ TELEVISION . TELEPHONE Q TELEPHONE/DATA WITH CABLE LIGHTING FIRTURES/DEVICES FLUORESCENT FIXTURE WALL/CEIUNG MOUNTED FIXTURE ® EMERGENCY LIGHT WITH SELF CONTAINED BATTERY O SURFACE OR PENDANT MOUNTED FIXTURE RECESSED FIXTURE MO MOTION DETECTOR PC PHOTO CONTROL CELL SWfTCH OUTLETS S ® STANDARD SWITCH, 120VAC, 20 AMP 3-WAY SWITCH, 120VAC, 20 AMP 3 3WAY S ® 3-POSITION SWITCH, 12OVAC, 20 AMP, HOA HOA LABEL SWITCH POSITION HAND -OFF -MOTION OR PHOTO UEE SINGLE -POLE Sp PILOT -LIGHTED 2 DOUBLE -POLE K KEY -OPERATED 3 THREE WAY LV LOW VOLTAGE S FOUR WAY S MASTER 4 M S DIMMER ❑ PUSHBUTTON D FIRE SYSTEM SYMBOLS O HEAT DETECTOR 0 SMOKE DETECTOR QO FIRE ALARM DISPATCH STROBE ALARM ❑A FIRE ALARM AUDIBLLNLSUAL ALARM ❑F FIRE ALARM MANUAL PULL STATION ADDITIONAL SYMBOLS OS SOUND SYSTEM SPEAKER SOUND SYSTEM VOLUME CONTROL ((B� DOORBELL VALVE SYMBOLS PILOT VALVE SOLENOID VALVE II V I CHECK VALVE CONTROL VALVE ELECTRICAL SITE: PLAN SYMBOLS () E-- UTILITY POLE AND GUY WIRE HH MANHOLE OR HANDHOLE HIT © BURIED POWER VAULT OR MANHOLE O TELEPHONE VAULT OR PEDESTAL ,�"7O-C FIBER OPTICS VAULT OR PEDESTAL 7...1 LUMINAIRE 11 PAD -MOUNT TRANSFORMER Im ROAD ABBREVIATIONS SPOT - SINGLE POLE, DOUBLE THROW SPO - SURGE PROTECTION DEVICE SPST - SINGLE POLE, SINGLE THROW EG - ENGINE GENERATOR DPST - DOUBLE POLE, SINGLE THROW MCC - MOTOR CONTROL CENTER WP - WEATHER-PROOF MCP - MOTOR CIRCUIT PROTECTION GET - GROUND FAULT INTERRUPT KAIC - KILO -AMPERES P - POWER INTERRUPTING CAPACITY C - CONTROL RN - TELEMETRY PANEL J - INSTRUMENTATION FCP - TIRE ALARM CONTROL PANEL PC - POWER & CONTROL CJ - CONTROL A INSTRUMENTATION CKT. - CIRCUIT C.O. - CONDUIT ONLY N.L - NIGHT TIGHT AL - ALUMINUM CU. - COPPER BOA HAND -OFF -AUTO SWITCH RUN TIME METER OC OPERATION COUNTER TMRIL MOTOR RUN INDICATION LIGHT SFII. SEAL FAIL INDICATION LIGHT SETT SEAL FAIL TRIP RESET OHL OVER TEMPERATURE INDICATION LIGHT MOIL MOTOR OVERLOAD INDICATION LIGHT LADDOR INDICATOR HGHT INDICATOR EIGHT A - AMBER C - GREEN B - BLUE R - RED C - CLEAR W - WHITE RELAY XYZ RELAY TR - Timed relay 123 CR - CoDlrol relay LIMIT SWITCH FLOAT SWITCH O LIMIT SWITCH, NORMALLY OPEN O -� ` FLOAT SWITCH, NORMALLY OPEN LIMIT SWITCH FLOAT SWITCH O.zz:Z:T--0 LIMIT SWITCH, NORMALLY CLOSED Q—� —� FLOAT SWITCH, NORMALLY CLOSED TIME DELAY CONTACT PUSHBUTTON 0.` DELAY CONTACT, NORMALLY OPEN, �I PUSHBUTTON, NORMALLY CLOSED _1TIME � THE TO CLOSE I�� TIME DELAY CONTACT PUSHBUTTON TIME DELAY CONTACT, NORMALLY _L PUSHBUTTTN, NORMALLY OPEN �O CLOSED, TIME TO OPEN O O INDICATE TYPE BY "LETTER INSTRLTMENTMETER - TIME DELAY CONTACT O`er O DELAY CONTACT, NORMALLY OPEN. A -AMMETER VAR - VRR AH -AMPERE-HOUR VAHO YARH - VARHOUR METER TTIME jME TO OPEN - POWER FACTOR W - WATTMETER NV V - VOLTMETER WH - WATIHOUR )AFTER TIME DELAY CONTACT AM VA - VOLT AMMETER v TIME DELAY CONTACT, NORMALLY CLOSED, TIME TO CLOSE RACEEWAYLEGEND SIffFLMI.EGfND RELAY CONTACT, NC P PROPOSED POWER RELAY CONTACT. INSTANTANEOUS CHANGE T11 PROPOSED TELEPHONE RELAY CONTACT. NO True PROPOSED INSTRUMENTATION PRESSURE SWITCH Fo PROPOSED GROUND BER OPTICS c PROPOSED CRQUC O PRESSURE SWITCH, NORMALLY OPEN aVIIDINGORP/iGIW PI W If6PND EXPOSED RACEWAY CONCEALED, UNDERGROUND, EMBEDDED, OR CONCRETE ENCASED RACEWAY HOME RUN TO PANELBDARD OR AS INDICATED CONDUIT RUN, BROKEN AND CONTINUED SAME SHEET OR AS NOTED FLEXIBLE CONDUIT Hs r CONDUIT RUN. HATCH MARKS INDICATE NUMBER OF CONDUCTORS CALLOUT INDICATING CONDUIT SIZE, NUMBER h' GRC 2 jI2 AND SIZE OF WIRE. CALLOUT INDICATING CONDUIT PER SCHEDULE CONDUIT BUT UP OR TOWARD J CONDUIT BENT DOWN OR AWAY 3 CAPPED CONDUIT ELECTRICAL A SIGNAL PLAN DEVICES SY S SOLENOID VALVE COIL ZS INTRUSION SNITCH MV MOTORIZED VALVE COIL MD MORON DETECTOR OMOTOR FS LT FLOOD SWITCH HE LEVEL TRANSDUCER HEATING ELEMENT OLIMIT SWITCH PS PRESSURE SWITCH PD PANIC BUTTON PE PRESSURE ELEMENT OTHERMOSTAT SWITCH O FLOW ELEMENT FY ZS INTRUSION SWITCH - KEY AE ANALYSIS ELEMENT THERMOSTAT 0-�0 TRERMO SWITCH, NORMALLY OPEN THERMOSTAT O— C-]—O THERMO SWITCH, NORMALLY CLOSED FLOWSWITCH 1 0 FLDWSWITCH, NORMALLY OPEN FLOWSWITCH FLDWSWITCH, NORMALLY CLOSED PRESSURE SWITCH n ( r) PRESSURE SWITCH, NORMALLY CLOSED 2 POLE SWITCH -1—� C+O 3 POLE SWITCH 1. THIS IS A STANDARD LEGEND. NOT ALL OF THE INFORMATION SHOWN ON THIS PACE WILL APPEAR IN THIS SET OF PLANS. 2. THESE DRAWINGS ARE CIAGRAMMATIC ONLY. EXACT LOCATIONS OF ELECTRICAL EQUIPMENT SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE INSTALLATION OF ALL EQUIPMENT SHOWN ON THESE CRAWINGS OR DESCRIBED IN THE SPECIFICATIONS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF ALL APPLICABLE CODES AND UTILITY COMPANY STANDARDS CONTACT THE UTILITY COMPANY REPRESENTATWES AND VERIFY THEIR REQUIREMENTS 3. NOTIFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EOUTMENT LOCATIONS ARE DISCOVERED OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS, LACK OF INFORMATION OR ANY OTHER REASON. NO PAYMENT WILL BE MADE FOR CHANGES WHICH HAVE NOT BEEN FAVORABLY REVIEWED BY THE ENGINEER. �..7kr3 m-rABAM - SHOWN sE nw, 33301 9th Avenue South, Su Re 3W DATUM �@ Federal Way, Washington96003-2600 (aoo172o.eos2 (206) 431-2300 Fax: (206) 431-2250 z ; - NO. REVISION BY DATE APPR CITY OF RENTON Works Department -d For Constrictio0 MILL �Tg oe •+e r 4J0613.0 Sll:f R-3693104 STRANDER BOULEVARD EXTENSION 1~12/5i2011 PHASE 1, SEGMENT 2A ELECTRICAL LEGEND .p 16727 h.srsac°tr" SIMD. 12/VS/Yl PS-12 -1 1 1 "231