R-3693108
C'') (D M O LU I— PANELSCHEDULE1. NO.LOCATION: L MCC SERVING: ELECTRICAL 8UILDING 1 3 15 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18 240/120 BO AMP VOLTS 3 WIRE MAIN CIRCUIT DESCRIPTION KVA AMP AMP KVA CIRCUIT DESCRIPTION BULGING HEATER 300 30 20 .13 ELECTRICAL ROOM LIGHTING 2P 20 .34 BUILDING OUTDOOR LIGHTING T-LEMETRY PANEL .50 20 20 .34 ENGINE GENERATOR BATTERY CHARGER FLOWMETER TRANSMITTER .25 20 30 4.33 ENGINE GENERATOR BLOCK HEATER VALVE VAULT RECEPTACLE .is 20 20 .54 BUILDING RECEPTACLE CIRCUIT METER VAULT RECEPTACLE .la zo 20 .20 WETWELL INTERIOR LIGHT EXHAUST FAN. °EF-1' 5 2o 20 .20 INLET MANHOLE INTERIOR LIGHT FIRE ALARM CONTROL PANEL 'PCP' 2D .18 RPBA RECEPTACLE SPARE 20 1 20 SPARE CONNECTION LOAD: DEMAND: LIGHTING AND CONTROL LOAD DEMAND LOAD: 11.12 KVA 46.33 AMPS 11.12 KVA 46.33 AMPS ELECTRICAL EQUIPMENT AND INSTRUMENTATION SCHEDULE : ITEM DESCRIPTION MANUFACTURER MODEL NO. ® IN DISCONNECT SYATCH - NEMA 4X STAINLESS STEEL [ENCLOSURE,HEAVY DUTY BREAKER, SERVICE ENTRANCE RATED, ERMAL MAGNETIC, 400 AMP, BOB VOLT, 42 KAIC WITHSTAND, SIEMENS HO6 OR APPROVED EQUAL RCUIT BREAKER SWITCH. MOUNT TOP OF ENCLOSURE 5'-0" OM FIMSHED GRADE. TOMATIC TRANSFER SWITCH - NEMA 1, 40D AMP. 600 VOLT SEE SPECIFICATIONS SEE RATED, 3 PHASE, 3 POLE, 42 KAIC WIT'NSTAND. SPECIFICATIONS © FLOAT SMIRCH SEE SPECIFICATIONS SEE SPECIFICATIONS Q LEVEL TRANSMITTER SEE SPECIFICATIONS SEE SPECIFICATIONS O INTRUSION ALARM SWITCH - CONTRACTOR SHALL SELECT HEAVY DUTY TYPE ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING SQUARE 0 K CLASS 9007 CONFIGURATION. WIRE SWITCHES IN SERIES. APPROVED EQUAL FLOOD SWITCH - N.O. REED TYPE FLOAT SWITCH, 20 VA. SEE OMEGA MODEL LVN-20 OR © DWG NO. PS-21FOR DETAIL APPROVED EQUAL © VALVE LIMIT SWITCHES - CONTRACTOR SHALL SELECT SQUARED HEAVY DUTY TYPE ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING C, CLASS 9007 OR CONFIGLIRATKAL. SEE DETAIL ON DING NO, PS-21. APPROVED EQUAL O WALL MOUNTED HEATING THERMOSTAT - 24V, SPSL RANGE HONEYWELL T80DOC1002 OR 40' - 99T, SET AT 60-F, MOUNT 4 FEET ABOVE FINISHED APPROVED EQUAL FLOOR. O INTRUSION DISABLE KEY SWATCH BOX - WITH CONSTRUCTION BEST 1W7JZNT NO CORE AND INTERIOR BOX. SPOT SWITCH WITH A MINIMUM SUBSTITUTIONS CONTACT RATING OF 15 AMPS AT 30 VDC. KEY SHALL BE REMOVABLE FROM THE OPEN OR CLOSED POSITION. MOUNT ENCLOSURE 4'-D' ABOVE FINISHED FLOOR. © PHOTO ELECTRIC SMOKE DETECTOR - 24 V POWERED, WITH SYSTEMS SENSOR 4WTA-B OR LOCAL AND AUDIBLE ALARM SIGNAL AND CONTACTS FOR APPROVED EQUAL REMOTE ANNUNCIATION THROUGH FOUR WARE CONNECTION TO RTU. O FLOW METER SEE WETWELL AND SEE WETWELL VAULT PLAN AND VAULT PLAN O WALL MOUNTED ODDLI14G THERMOSTAT - SNAP ACTION, SPDT HONEYWEI.I T631CII03 OR LINE VOLTAGE AIR SWITCH CONTROLLER. RANGE: -30' - 100'F, APPROVED EQUAL SET AT 75'F. MOUNT 4 FEET ABOVE FINISHED FLOOR. ' CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND DEICES PROVIDED BY OTHERS. HEATER SCHEDULE. ITEM DESCRIPTION MANUFACTURER MODEL NO. PUMP ROOM ELECTRICAL HEATER WITH UNIVERSAL MOUNTING BRACKET - 3KW, 24OV, SINGLE PHASE, WITH 24V CONTROL TRANSFORMER AND _ 1 OR POWER CONTRACTOR FOR THERMOSTAT CONNECTION. MOUNT BOTTOM OMARK APPROVED EQUAL OF HEATER T-C' ABOVE FLOOR. 1.14314TING FIXTURE SCHEDULE MANUFACTURER * LAMP TYPE DESCRIPTION NAME CATALOG NO. OTY. CATALOG NO. REMARKS FLUORESCENT, LIGHT FIXTURE, 120 VAC, 4'-2' LONG, HIGH -IMPACT ACRYLIC LENS, MOLDED FIBERGLASS 32WT8 Al REINFORCED POLYESTER HOUSING, (2)-32W LAMPS, ENERGY UTHONIA DMW 2 32 ARDP 120 2 32 WATT SAVING BALLAST, CEILING MOUNTED, ILL.LISTED FOR WEL LOCATIONS. FLUORESCENT OUTDOOR AREA LIGHT - (2)-42W FLUORESCENT LAMPS, 120V BALLAST, 9"H, 13' W. 7 3/8" 42 IRT PHOTOCELL A2 D. BIE-CAST ALUMINUM HOUSING, WAREGUARD, MOUNT TOP UTHONIA TWIRL 2/427RT 12D PE WG LPI 2 42 WATT CONTROL OF FIXTURE 6' BELOW ROOF EAVE, ILL LISTED FOR WET LOCATIONS Al EXPLOSION PROOF LIGHT FlXIURE, 120 VAC, - 20DW INCANDESCENT LAMP. MOUNT TO STRUCTURT CDUNG. APPtETON AAUI5N 1 INCANDESCENT r CLASS 1, DIVISION 1 RATED, U.L LISTED FOR WET I_ 200 WATT LOCATIONS _J X gUM11M aF LAMPS PIN 1111=I 0 n FEDA D: CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 POWER CONDUIT AND CONDUCTOR SCHEDULE . CIRCUIT SOURCE DESTINATION TRADE SIZE (QUANTITY) CONDUCTORS NOTES P1) UTILITY TRANSFORMER CURRENT TRANSFORMER ENCLOSURE 4' (3) - JIM MCM, (0 - i600 MCM N �P2) CURRENT TRANSFORMER ENCLOSURE UTILITY METER 1 I/4' (1 - /14 (_P3) CURRENT TRANSFORMER ENCLOSURE MAIN SERVICE DISCONNECT SNITCH +' (3) - /600 MCM (t) - 116OU YCY N P4 _ 4 MAIN SERVICE DISCONNECT SWITCH AUTOMATIC TRANSFER SWITCH, 'ATS' 4" - JIM MCM, 1) - fSDO MCM N, (1) - 13 GRD P5) STANDBY GENERATOR AUTOMATIC TRANSFER SWITCH, °ATS' 4' (3 - j6D0 MCM, I - #600 MCM N. 1 - J3 GRD -P6 AUTOMATIC TRANSFER SWITCH, 'ATS' MOTOR CONTROL CENTER, 'MCC" 4' (3) - /16DO MCM, (t) - A60D 912J N. (1) - R3 ORD -P7 MOTOR CONTROL CENTER, "MCC' PUMP Na 1 TERMINATION BOX 1 Ile (3) - y4, (1) - j6 GRD P8. MOTOR CONTROL CENTER, 'MCC' PUMP 14 2 TERMINATION BOX 1 1/4' (3) - ]4, (1) - J6 GRD . P9 MOTOR CONTROL CENTER, 'MCC' PUMP NO, 3 TERMINATION BOX 1 1/4' NYLON PULL -CORD CONDUIT FOR FUTURE USE 'PTO MOTOR CONTROL CENTER, -MCC' PUMP NO. 4 TERMINATION BOX 1 14' NYLON PULL -CORD CONDUIT FOR FUTURE USE .0.11 PIMP NO. I TERMINATION BOX PUMP N0. 1, P-1 - PUMP MOTOR CABLES CONDUCTORS RUN IN CABLE TRENCH SYSTEM :P.12 PUMP NO. 2 TERMINATION BOX PUMP N0. 2, P-2 - PUMP MOTOR CABLES CONDUCTORS RUN IN CABLE TRENCH SYSTEM 0 UGIDING PANEL, -L- ENGINE GENERATOR BATTERY CHARGER 3/4' (2) - 412. (1) - 112 GRD LIGHTING PANEL, 'L' ENGINE GENERATOR BLOCK HEATER 3/4" (2) - 110. (1) - /10 GRD P75. LIGHTING PANEL, 'L- TIRE ALARM CONTROL PANEL, 'FCP' 3/4" (2) - #12. (1) - 012 CRD �P16 UDOM PANEL, 'L- BUILDING HEATER 3/4' (2) - #10, (1) - 110 GRD R17� LIGHTING PANEL, 'L" TELEMETRY PANEL, "RTU- 3/4' (2) - 112. (1) - p2 GRD P1B LIGHTING PANEL, 'L" VALVE VAULT RECEPTACLE 3/4* 2) - #12, (1) - 112 GRD -PUB: LIGHTING PANEL, °L" METER VAULT RECEPTACLE 3/4* (2) - /12. (1) - #12 GRD P20 ENGINE GENERATOR LOAD BANK 4' 3 - X6DO MCM, (Q - J5011 MCM N. 1 - #3 GRD --P2E WETWELI INTERIOR LIGHT WETWELL LIGHT TERMINATION BOX - MULTICONDUCTOR FLEXIBLE POWER CABLE, 3 - 2 CONDUCTORS RUN IN CABLE TRENCH SYSTEM P22 WETWELL LIGHT TERMINATION BOX LIGHTING PANEL, 'L' 3/4' (4) - #12. (1) - 112 CRD -P2 , LIGHTING PANEL, 'L- COOLING THERMOSTAT 3/4' (2) - /12, (1) - 112 CRD -P24 COOUNG THERMOSTAT EXHAUST FAN, "EF-Y 3/4' (2) - /12, (1) - 112 CHI) Q25) UGHRNG PANEL, 'L' FLOWMETER TRANSMITTER 3/4' (2) - #12. (1) - /12 GRD -P2fi COOLING THERMOSTAT EXHAUST LOUVER, 'LA-1' 3/4' (2) - /12. (1) - /12 ORD RY7) NLET MANHOLE INTERIOR LIGHT WETWELL LIGHT TERMINATION BOX 1' MULTKXINOUCTOR FIEXRE POWER CABLE, (3) -- #12 CONDUCTORS RUN IN CABLE TRENCH SYSTEM -P2D LIGHTING PANEL, 'C RPBA RECEPTACLE 3/4" (2) - r12, (1) - /12 ORD _ __ _ _________ '.. ' ._::::CONTROL'CONDUIT AND CONDUCTORSCHEDULE ; CIRCUIT SOURCE DESTINATION TRADE SIZE C41ARTICONDUCTORS NOTES ACID WETWELL FLOATS CONTROL TERMINATION BOX ImANuFArTURER FLOAT CABLES CONDUCTORS RUN IN CABLE TRENCH SYSTEM C2. WE10€L1. INTRUSION SWITCH CONTROL TERMINATION BOX IMULUCONDUCTOR FLEXIBLE CONTROL CABLE, (3) - /14 CONDUCTORS RUN IN CABLE TRENCH SYSTEM CWD CHECK VALVE LIMIT SWITCH VALVE VAULT JUNCTION BOX 3/4' (2) - 114, (1) - 114 GRD CHECK VALVE LIMIT SWITCH VALVE VAULT JUNCTION BOX 3/4" (2) - /14, (1) -- j14 DID) 05 VALVE VAULT INTRUSION SWATCH VALVE VAULT JUNCTION BOX 3/4' (2) - 114, 1) - /14 GRD 06 VALVE VAULT FLOOD SWATCH VALVE VAULT ,AINCTION BOX 3/4' (2) - /14. (1) - #14 ORD T>7 VALVE VAULT JUNCTION BOX TELEMETRY PANEL, 'RTU" 3/4' (9) - /14, (1) - #14 GRD :T2T ELECTRICAL ROOM INTRUSION SWITCH TEUUIETRY PANEL, -RTU- 3/4' (2) - 114. (1) - /14 ORD .C9D ELECTRICAL ROOM SMOKE DETECTOR FIRE ALARM CONTROL PANEL, 'FCP" 3/4 (4) - #14. (1) - (14 GRD .C10 FIRE ALARM CONTROL PANEL, 'FCP° TELEMETRY PANEL, 'RTU' 3/4' (2) - 114. (1) - 014 GRD :Cll INTRUSION DISABLE SWITCH TELEMETRY PANEL, -RTU' 3/4' (2) - /14, (1) - #14 ORD C12) HEATING THERMOSTAT HEALER, 'Hf' 3/4' (2) - 4, 1 - 114 GRD 13 MOTOR CONTROL CENTER, 'MCC' TELEMETRY PANEL, "RTU" 1' (22) - #14. (1) - §14 GRD C14: ENGINE GENERATOR LOAD BANK 3/4 12 - 4, 1 - 04 GRD .C15 AUTOMATIC TRANSFER SWITCH, 'ATS' ENGINE GENERATOR 3/4" (2) - /14. (1) - 014 GRD D16. TELEMETRY PANEL, 'RTU' ENGINE GENERATOR 3/4' (8) - /14, (1) - 014 ORD C17: METER VAULT INTRUSION SWITCH METER VAULT CONTROL JUNCTION BOX 3 4 2 - 4, 1 - 14 GRD C18) CONTROL TERMINATION BOX TELEMETRY PANEL. 'RTif (9) - j14, (1) - #14 GRD MITER VAULT FLOOD SWATCH METER VAULT CONTROL JUNCTION BOX ;31'r /+' 2) - 1114, (1) - #14 GRD 20 a DING FLOOD SWATCH TELEMETRY PANEL, 'RTLr /4 (2) - /14, (1I - A4 GRD (C21 METER VAULT CONTROL JUNCTION BOX TELEMETRY PANEL, 'RTU" 3/4 (4) - /14, (1) - 014 GRO INSTRUMENTATION CONDUIT AND CONDUCTOR SCHEDULE CIRCUIT SOURCE DESTINATION (QUARTITY) CONDUCTORS NOTES Jf WETWELL LEVEL TRANSMITTER CONTROL TERMINATION BOX LEVEL TRANSMITTER CABLE CONDUCTORS RUN IN CABLE TRENCH SYSTEM J2 METER VAULT FLOWMETER METER VAULT JUNCTION BOX MANUFACTURER's CABLES METER VAULT JUNCTION BOX FIDWMETER TRANSMITTER F11 MANUFACTURER'S CABLES CAAD TELEMETRY PANEL "RTU' FLOWMETER TRANSMITTER (2) - j14, (1) - 114 GRD CIRCUITS "J4A' AND 'J4B' SHARE CONDUIT'.W TELEMETRY PANEL. -RTU" FlOTIIEIFR TRANSMITTER (1) 2-CONOUCTOR SHIELDED CABLE CIRCUITS "J4A" AND "Afl" SHARE CONDUIT'.W rMICONTROL TERMINATION BOX TELEMETRY PANEL, -RIU- 3/4 (1) 2-CONDUCTOR SHIELDED CABLE .J6 TELEMETRY PANEL. "RTU' ANTENNA 1 2' IANTENNA CABLE H r 16727 Rya ff r[M5C `� sfcxefl: IziDs��r f\' 38513 �- ST�. R-3693108 - Qy. SHOWN a �"n°°' CITY OF STRANDER BOULEVARD EXTENSION BergerABAM _ ry y RENTON F �� ; �, "'Ic works Deportment PHASE 1, SEGMENT 2A 333019thAvenue South, Suita300 ed For oggtrtfCi'a Dale Federal way, Washington 98003-2500 reoonzo-eosz�. ELECTRICAL SCHEDULES (206) 431.23DO Fax: (206) 431-2250 R.... ` o N0. 8613 REVISION BY DATE APPR Roh H nson .E. 0 PS-161