Loading...
HomeMy WebLinkAboutR-3693112('') Cy) CO M O LU a m WETWELL EIGHT TERMINATION BOX FLOATS AND LEVEL TRANSMITTER TERMINATION BOX 1 PUMP NO. 1 TERMINATION BOX PROPOSED NAMEPLATE, TYP. TERMINATION BOX, STAINLESS STEEL NEMA 4 ENCLOSURE, 12"H X 12"W X 8" D. PROVIDE MEANS FOR - PAD LOCKING. SECURE TO WALL WITH (4) STAINLESS STEEL CMU ANCHORS. NAMEPLATE SCHEDULE TERMINATION BOX TAG NAMEPLATE SCHEDULE NP1 TERMINATION BOX — WET WELL FLOATS AND LEVEL TRANSMITTER NP2 TERMINATION BOX — WET WELL LIGHT NP3 TERMINATION BOX — PUMP NO. 1 NP4 TERMINATION BOX — PUMP NO. 2 NP5 TERMINATION BOX — PUMP NO. 3 NP6 TERMINATION BOX — PUMP NO. 4 PUMP NO. 4 TERMINATION BOX PUMP NO. 3 TERMINATION BOX PUMP NO. 2 TERMINATION BOX PROPOSED ELECTRICAL —/ "-r i "I!' "i'1fHiri'il'I!rlll�lll ���flf I Ill%i� Irlf r I i��fJ' �i nI I!��� BUILDING 1If iI !III' jll�ili'�Ill(i (j'Ir i�''Ii,I Ill j1111 LEAVE MINIMAL SEPARATION BETWEEN EDGE OF BUILDING I�i II AND TRENCHBOX COVER TO ALLOW PASSAGE OF ALL TRENCH BOX CABLES. MAXIMUM SEPARATION OF 6". TERMINATION BOX OBLIQUE DETAIL CADWELD TYPE TA. CADWELD CABLE TO CABLE TEE CONNECTION. #1/0 COPPER CONDUCTOR GROUND TEE DETAIL NOT TO SCALE Al CADWELO TYPE GR NOT TO SCALE CADWELD TYPE RR. CADWELD END CABLE TO UPP�" CC #11/0 COPPER CADWELD CABLE TO GROUND _ CONDUCTOR ROD CONNECTION. 5/8" X 8' COPPER GROUND ROD. r REBAR PROPOSED CABLE TRENCH SYSTEM #1/0 COPPER CONDUCTOR GROUND REBAR DETAIL NOT TO SCALE CADWELD TYPE XA. -ED CABLE TO CABLE i CONNECTION. Y1/0 COPPER CONDUCTOR (TYPICAL) GROUND TEE DETAIL GROUND CROSS DETAIL 73 NOT TO SCALE NOT TO SCALE 0 :� ... �� 'r rAB" - AS FEDND: CALL 48 HOURS BEFORE YOU DIG 33301 9th Avenue South, Suite 300 N 1-800-424-5555 Federal Way, Washington 98003-2600 teoor7zososz� A ee ro'scrno. N0. J 206 431-2300 Fax: 206 431-2250 I ) I ) A.A 211.pa9 BOX, TYP. ` NPi 18' TIP. I U K t U NP3 S-2 PROPOSED ELECTRICAL BUILDING PROPOSED CABLE TRENCH SYSTEM INSTALL WET WELL AND INLET MANHOLE LIGHT SWITCHES INSIDE TERMINATION BOX TO PANEL "L" LN-P-51 (INP6 "MCC" -=TO 'MCC" TERMINATION BOX ELEVATION DETAIL NOT TO SCALE PROPOSED CONCRETE COVER. PROPOSED CONCRETE GROUND ROD PROTECTOR 13" DEPTH X 12" HEIGHT WITH COVER. PIPE INC. #12R-12A & 12R-12T, OR EQUAL. 5/8"x8' LONG COPPER GROUND ROD. GROUND ROD DETAIL NO SCALE "MCC ELECTRICAL BUILDING WALL SHOWNfit Uii i V� _ �`" RENTON ublic Works Department ved For �pn ru r REVISION BY DATE APPR nor _ H neon P F —r CABLE, NECESSAR TERL TERMINATION BOX ENCLOSURE CABLE FR06 TRENCH SYSTLI PROPOSED TERMINAL BLOCK WITHIN TERMINATION BOX ENCLOSURE FIELD WIRE CONNECTIONS CORD GRIP (CGB), SIZE TO CABLE DIAMETER CABLE TRANSITION , DETAIL (TYPICAL) S-2 NOT TO SCALE CAST -IN -PLACE CONCRETE HOUSEKEEPING PAD, SEE DWG NO. PS-16 FOR LOCATION. ROUGHEN FLOOR UNDER PAO PRIOR TD POURING PAD. % PROVIDE 44 W1.4xW1.4 WWM AT TOP FACE WITH 1-1/2" CLEAR COVER FY MIN. BEYOND EQUIPMENT BOLTS, TYP. 7/8" CHAMFER, ALL OUTER EDGES #4 DOWEL, EACH CORNER AND IS' O.C. 3" EMBEDMENT INTO FLOOR CONCRETE FLOOR AND REINFORCEMENT PER BUILDING STRUCTURAL DRAWINGS. TYPICAL EQUIPMENT PAD NOT TO SCALE r rass,dx" ti s' aw a 16727 � n_. R4ra,exw9 R-3693112 SfCNSA� !2/t15/ri SfCA �12/5�201i STRANDER BOULEVARD EXTENSION, PHASE 1, SEGMENT 2A ELECTRICAL DETAILS - SHEET i PS-20 119°f231