HomeMy WebLinkAboutR-3693113SO CORD CONNECTOR SURFACE MOUNTED INTRUSION SWITCH. MOUNT (TYPICAL). J BOX. - (fl PER MANUFACTURER'S M RECOMMENDATIONS. PROVIDE STAINLESS STEEL CALUMS GRIP RIP BASE (CGB) A CONDUIT - SO TYPE CORD. il PENETRATION INTO MANHOLE. =. LU :s 0x9r - Y . „ GRS CONDUIT STRAPPED TO i MOUNT FIXTURE TO MANHOLE i WALL WITH MINIMUM OF (2} WALL NEXT TO ACCESS LADDER. h = :' STAINLESS STEEL PIPE CLAMPS PROPOSED INLET s PROPOSED BRUSHED - SPACED EQUALLY APART- I MANHOLE t STAINLESS STEEL I n f--P..22 PLATE MOUNTED TO "'"' LIQUID LEVEL SNATCH. SET I --,,_; 3 VALVE FLANGE. TO SWITCH WITH 1/2" OF 3 F SEE OWG NO. I - r m WATER ON FLOOR. PS-16 x x x X X x x x PROPOSED WETWELL GO PROPOSED LIMIT SNATCH. a BUILDING INTRUSION SWITCH DETAIL CHECK VALVE LIMIT SWITCH DETAIL VAULT FLOOD SWITCH DETAIL L NOT TO SCALE NOT TO SCALE NOT TO SCALE .i PENETRATE CABLE TRENCH SYSTEM• I Z (, ri -II tl,Y},I S.S. 1"X3" LYEBOLTS, S.S. \ SPRING TYPE CARABINER. USE S.S. TO SUPPORT FLOAT CORDS, 1 c!L`� S.S. UNISTRUT, SPAN ACROSS ;444 AVAILABLE SPACE IN WEl1MELL. MOUNT TELEMETRY ANTENNA, ANTENNA FEED LINE LB CONDUIT BODY WITH 3 8"0 SST EYE BOLT, NUT, AND POSITIONED 20' ABOVE GRADE. CORD GRIP BUSHING I 1 ' � ,\� f TO 4—HOLE S.S. L" BRACKET- / ANCHOR CONTRACTOR SHALL COORDINATE I WITH OWNER ON DIRECTION TO I 2" LENGTH OF 3/16" 0 SST POINT ANTENNA. CABLES SST CARABINER SIZE TO 1Y,' GALVANIZED RIGID r- FIT LIFTING CABLE ! / STEEL x 12" LONG € i i PROVIDE CABLE SLACK TO E --• - — '" ALLOW FLOAT ELEVATION MALLEABLE IRON OR I t PROPOSED CABLE CHANGE OF 1° (TYP.) STEEL REDUCER SEE ELECTRICAL SITE TRENCH SYSTEM PLAN OWG NO. PS-13 INLET MANHOLE ELECTRICAL PLAN b FOR CONTINUATION FLASHING 1/2 TRANSDUCER PROVIDE STRAIN RELIEF I CABLE i 2' RIGID BUILDING WALL ALL FLOAT SWITCHES SHALL BE GALVANIZED STEEL € 4" DI SCH 40 PVC PIPE. POWERED BY INTRINSICALLY SAFE I s _a' TELEMETRY PANEL, "RTU" MOUNT FLUSH WITH RELAYS PER ANSI/UL 913. SHOWN - ; ? GRS CONDUIT STRAPPED TO BOTTOM OF WET WELL TYPICAL FOR ALL FLOATS. MOUNT Cp FLOATS APPROXIMATELY 45 WALL WITH MINIMUM OF (2) b s DEGREES TO THE WALL AND IN THE "U CLAMP STAINLESS STEEL PIPE CLAMPS :PROVIDE AND INSTALL ': 6 DIRECTION OF FLOW AS TO 2" GRS TO � FLOOD SNATCH fiMALL SPACED EQUALLY APART. STAINLESS- STEEL PREVENT HITTING THE WALL DURING PROPOSED TO "RTU" CONDUIT "T" FITTING BE LOCATED BELOW -MOUNTING BRACKETS. ON I TURBULENT FLOW, TELEMETRY PANEL a LIQUID LEVEL SWITCH- SET TO PVC -PIPE, 30 O,C; ? EXTERIOR CMU WALL �,•, SWITCH WITH 1/2" OF WATER ON WET WELL PUMP "U" CLAMP; FASTEN TO CMU SEE DWG NO. BUILDING FLOOR. P I WALL AND PROVIDE BLOCKING PS 16 OF a LEVEL TRANSDUCER SEE AS REQUIRED PUMP STATION s MECHANICAL DRAWINGS #6 BARE COPPER GROUND n FOR MOUNTING DETAILS TO GROUNDING SYSTEM. BLOCKING BUILDING FLOOD SWITCH DETAIL ELECTRICAL BUILDING NOT TO SCALE a p H."� MILL _ WET WELL LEVEL TRANSDUCER AND FLOAT ANTENNA INSTALLATION DETAIL 1/2 V—D" a�s9 eAo SWITCH DETAIL o �Q'flL �, NOT TO SCALE SIGNEQ' 12/b5/f1 .f.H R-3693113 m FEDAID: * scx„m sr„c wnam w", „ea °A1e �,� SHOWN '°P1R""=NV°1°°'�"9i CITY OF STRANDER BOULEVARD EXTENSION 1z/s/zo11 eraerABAM =�' i�__a� %r RENTON ; CALL 48 HOURS �/ aNNE �_ �"* PHASE i, SEGMENT 2A BEFORE YOU DIG 333019th Avenue South, Suite 300 "'T _ ���� DATUM Pub3iced oFor Conorfine Federal Way, Washington 98003-2600 leoa��-+ Z ELECTRICAL DETAILS - SHEET 2 PS—Z 1 1-800-424-5555 (206)431-2300 Fax: (206)431-2250211 NO. REVISION BY DATE APPR"�01 ern e .Han on P.E. ate 120 231