Loading...
HomeMy WebLinkAboutR-369315322'-1158" lnent Retaining Wall 41 G,E. = 29.50 Ete.. 34.00--� Ground Line at Back of Wall Elev. 32.00 (Max.) 1 Excavation Line Elev. 16'-4 Retaining #1 I �--- Abut. #1 I�/3'-4" 109'-2" Structure ODeni 102'-6" Bk.-to-Bk. of Abutments New Bri Abut. #3 r + r r r r '�... - y. a. _ J..- •J-. - 1- - . - - - - 53a I i 538 -•� ---------- - - --- -- -- - ------ - --- - - --- -- - -------- ----- ----,- (-)1.00 -------- I � I i Anchor Locotions 2 -6 4 Spa. @ 6'-0" = 24'-0" 5'-61, � 5'-0"1 �2 41,2" tSee Note 6) - -- - - Al. Bottom -of -Sheeting Elev. t-)18.00 O O m •ar;es / _LEVEL A_ A Smooth PVC cr Polyethylene t e. 200 or 250 ` /j,A Typ. `eo Bpi.-� ;K -Seal end with taper Typ. �B SHORING ELEVATION - STAGE II * FINAL GROUND ANCHOR LOCATIONS SHALL BE PROVIDED AT LOCATIONS THAT DO NOT EXCEED THE INDICATED SPACINGS BY MORE THAN 6". THE ANCHOR LOCATIONS SHALL BE REVISED TO BE LOCATED AWAY FROM PILE KNUCKLE LOCATIONS AND TO LIMIT THE AMOUNT OF SHEETING WEB REMOVAL REQUIRED TO PROVIDE THE NECESSARY HOLES THROUGH THE SHEETING. ate 6" min. dia. casi th !� !� V C O ogee Cron t Prestressing steel strands with smootl d AnahOr c.._ plastic sheathing Spacer (1,2" minimum height) @ 5' maximum spacing, Typ. �iB Temporary Retaining Permanent wall #2 3 4 I 22' -11 sle ` Retaining Wall #2 G.E. = 30.50 ' I ,_'Elev. 34.00 T/T Elev. (See RA-02) I I 54C 60C i Excavation Line - - Elev. (-)l.00 2'-G" I 3 Spa @ 5'-6" 3 Spa. @ 6'-0" 2'-41,2" 1 (See Note 6) = 16'-6" = 18'-0" Anchor Locations .I I 1 J Bottom of Sheeting �, Elev. (-)18.00 10 it SECTION A -A )Encapsulation cier bond length with Internal grout ,2' dio. smooth prestressing steel it III astic sheathing strands pregrouted inside "1 )7I, Spacer & centralizers - alternating @ 5' moximum spc1ng xternal grout +1 Corrugated ,not in tension) Polyethylene or PVC YeH SEE NOTE 3 SECTION B-B External grout (in tension) Prestressing steel strands �o o- End Cap c NOTES• o Greased and Shoathed Prestressing -,. = D Steel Strands, Typ.->. 1. ALL 0.6" DIAMETER 7-WIRE, LOW RELAXATION 270 ksi PRESTRESSING STEEL STRANDS SHALL BE ASTM A416. Corrugated sheathing and 2. FOR DETAILS OF WALER d BRACKET ASSEMBLY, SEE SHEET RA-10. 'X' internal spacers/centralizers XY = ANCHOR DESIGNATION WHERE IS THE COLUMN NUMBER at 5' maximum spacing, Typ. 3. CONTRACTOR SHALL FURNISH AND INSTALL GROUND ANCHORS MEETING THE REQUIREMENT: FOR AND 'Y' 1S THE LEVEL. _. _LEVEL C DESIGN LOAD, UNBONDED LENGTH. AND LOCK -OFF LOAD SHOWN IN THE GROUND ANCHOR SUMMARY _-_ TABLE. ITEMS INDICATED WITH 3 ASTERISK () SHALL BE DESIGNED OR SELECTED BY THE G.E. = GROUND ANCHOR ELEVATION AT WALL CONTRACTOR. ALL MATERIALS AND WORK SHALL BE IN COMPLIANCE WITH THE PERFORMANCE F.L. = FOLD LINE SPECIFICATION FOR GROUND ANCHORS (SEE SPECIAL PROVISIONS). c„ 4. AFTER THE SHEET PILE 1S DRIVEN TO ITS FINAL LOCATION, NO EXCAVATION 1N FRONT OF WORK WITH SHEETS RA-07, RA-09, AND RA-10. Front Face SEE NOTE 3 THE WALL SHALL BE MADE IN EXCESS OF 1'-6" BELOW THE GROUND ANCHOR HOLE LOCATION IN THE SHEET PILE UNTIL THE GROUND ANCHOR, WALERS, ETC. HAVE BEEN INSTALLED. TESTED, AND APPROVED, PZ 40 Sheet Pile 5. THE PERMANENT PORTION OF THE RETAINING WALLS HAS BEEN DESIGNED FOR A TEMPORARY EXCAVATION DEPTH OF ELEV. -1.0, AND A PERMANENT FRONT FACE GRADE OF ELEV. 14.0 WITH A 3:1 SLOPE TO THE PROPOSED ROADWAY. ALL TIEBACK LEVELS SHALL REMAIN IN PLACE FOR THE PERMANENT PORTION OF THE WALLS. ANY EXCAVATIONS BELOW THE SPECIFIED DEPTH OR PEMANENT CONDITIONS WITH A LOWER FRONT FACE ELEVATION REQUIRE CONTRACTOR DESIGNED 1 WALLS APPROVED BY THE OWNER. LL SHEET PIKE WALL WITH PERMANENT GROUND AIJCHOR SESHOWNTED U�TO3'-O` �FROM A6. DJACONNDFAONCOHDRNE53ALLSOBHER3ANCHOFS T08BE&LOCATM R-3693153 FEDAID: STPUL-1276(004) HPP-1276(005) �i BergerABAMI Q7 ADDENDUM N0. 1 Ao,N/ MAF 7-10— 2013 asom "Hc AS SHOWN wssa"w"w,ti'urm� CITY OF �•" RENTON STRANDER BOULEVARD EXTENSION PHASE 1, SEGMENT2A t2/OS/11 " a CALL 48 HOURS �� `\ti HANSON RECORD DRAWINGS 7/31/2014 �' D A BEFORE YOU DIG 33301 9th Avenue South, suite 30o CDP ° � �,� �rl nu s�,,c 1 DATUM Public Works Department Approved For Construotlor, BNSF BRIDGE N0. 11.07 L.S. 0051 RA-08 w 1-800-424-5555 Federal Way, Washington 98003-2600 206 431-2300 Fax: 206 431-2250 ( ) ( ) /)Copyright Hanson Prolessimol Services Inc. 2011 N0. RE i` ION BY DATE -`,PPR ^^ T� nAr Da c LORD""" Robert M. Hanson P.E. Dote SHORING ELEVATION STAGE 11 —1 64 231