HomeMy WebLinkAboutR-3693188(Ty) 'V'^J (/ C'7 O r) W F_ M C M M To Tacoma (RY South) Stage 11 , stage I 120 mil Bridge Deck Waterproofing Membrane (Stage 1) Temporary Ballast 2 „ Asphalt //_ Retainer Protection Board Angle 120 mil Bridge Deck I'z" Asphalt Waterproofing Membrane (Stage Ill Protection Board W4Ox277 or W40x99 Beam SECTION G-G Proposed Waterproofing Steps: 1. Apply waterproofing membrane to Stage I Structure except faying surface of Temporary Ballast retoiner. Insure that waterproofing membrane is not applied to surface of beam to be welded. 2. Slope ballast away from ballast retainer to keep ballast from spilling onto Stage II structure when the retainer plate is removed. 3. Apply waterproofing membrane to Stage 11 Structure and remaining retainer ongle. Provide enough overlap to previous membrane to ensure membrane integrity. To Seattle (RY North) 0 0 0 0 C See Detail 'E', Typ. C Waterproofing System rr2" Aspho It Protection Board SECTION A -A 3'q" Be I I ost Pon Plate I'z' Asphalt Protection Board F rs to Waterproofing System 34' BoIlast3'4" BalIost Pon Plate Pan Plate SECTION D-D Typ 0 �DP104. OP105 or SDP11.07 Waterproofing System Ir2" Aspha I t Protection Board SECTION B-B 3'q' BaI last Pan Plate Deck Plate Abutment Deck Plate DETAIL E (Waterproofing not shown for clarity.) guhm� i'f � O 6 3 51c�h in.�ll� f 077 ty g.r- j OOU I40 ESTIMATED WATERPROOFING OLIANTITIES DESCRIPTION UNIT Ouanti BRIDGE DECK WATERPROOFING SO. YDS. 510 WATERPROOFING SYSTEM: WATERPROOFING SYSTEM SHALL BE 120 MIL ACRYLIC -BASED, COLD SPRAY APPLIED. SEAMLESS ELASTOMERIC WATERPROOFING MEMBRANE AS MANUFACTURED BY BRIDGE PRESERVATION, LLC. KANSAS CITY, MO. 64171, 1816) 561-9996. OR EQUAL. AT THE OPTION OF THE CONTRACTOR. A BRIDGE DECK MEMBRANE SYSTEM MANUFACTURED BY STIRLING-LLOYD. 420 SACKETT ROAD. NORTH HAVEN. CONNECTICUT 06473. (203) 230-9448. MAY BE SUBMITTED FOR APPROVAL. SPRAY APPLIED WATERPROOFING SYSTEMS SHALL HAVE ONE I'2" THICK LAYER OF ASPHALT PROTECTION BOARDS PLACED ON THE DECK SURFACE. PRIOR TO APPLYING WATERPROOFING SYSTEM, ALL VOIDS, GAPS. AND RECESSES IN THE STEEL BALLAST PLATE DECK SHALL BE FILLED IN WITH METASET 300. OR APPROVED EQUAL, PER THE MANUFACTURER'S RECOMMENDATIONS. GALVANIZED SHEETING. WATERPROOFING MEMBRANE, AND OTHER JOINT DETAILS SHALL EXTEND UP THE CURB FACE 1'-4" MIN. ON EACH SIDE. WATERPROOFING SYSTEM SHALL BE APPLIED TO BALLAST PLATE DECK AND INSIDE FACE OF CURBS. CONTRACTOR SHALL SUBMIT DETAILED APPLICATION PROCEDURES. MATERIAL SPECIFICATIONS AND SHOP DRAWINGS FOR THE WATERPROOFING SEE SHEET RA-44 FOR SECTION C-C AND F-F. SYSTEM INCLUDING FIELD INSTALLED JOINT SYSTEMS. TO THE ENGINEER FOR APPROVAL PRIOR TO INSTALLATION. R-3693188 FEDAID: STPUL-1276(D04) HPP-1276(CD.) �) BergerABAM �/ 33301 9th Avenue South, Suite 300 Federal Way, Washington 98003-2600 206 431-2300 Fax: 431-2250 ( ) ) <� HANSON OCopyrlght Hanson Prolesslond Services Inc. 2011 ...rno AS SHOWN 4p1"U'`�.o„u"fw� � DATUM CITY OF RENTON P�a•Works Department Appro ed For Construction Robert M. Hanson P.E. Dote STRANDER BOULEVARD EXTENSION PHASE 1, SEGMENT2A BNSF BRIDGE NO.11.07 L.S. 0051 BRIDGE DECK WATERPROOFING DETAILS (1 OF 2) 12/05/11 c� RECORD DRAWINGS 7/31/2014 � CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 GT� ! > . F A- 43 —»<o-nnH N0. REVISION BY DATE APPR MAF �199 "231