Loading...
HomeMy WebLinkAboutR-3693221L MAY24, tou AMED AID Our A PLAN VIEW NOT TO SCALE I II ° 2'-0- l I 4 �o 00 1'-0" J �Ir 9fI 1'-3 " 1'-3�' END VIEW N07 70 SCALE INTERIOR A u N C m Q NI Z y � Y p A d E Z U N N m IU CU rr1i 3 zo' ro� w000r •• •. P .yam V z r, tA4C}wn -T 3'-6" 4'-0" "CONSEAL" GASKET - 3/4" KEYWAY DETAIL TYPICAL DETAIL'S' NOT TO SCALE 10" CASTING 4 3/4" DIA. KNOCKOUT 8 EACH SIDE 4 SIDES 32" DIA. FRAME & COVER 3/4" DIA. x 2" LG. S.S. HEX 80LT W/ S.S. WASHER 4 REQ'D 3/4" GASKET 3/4" 0 L.F. INSERT 4 REQ'D I, _! 5„ WALL BETWEEN FRAME & RISER TYPICAL DETAIL "A" NOT TO SCALE 1/2" RECESS NOTES: 1. ALL MANHOLES SHALL COMPLY WITH STANDARD SPECIFICATIONS FOR PRECAST REINFORCED CONCRETE MANHOLES. 2. BONDING RIBBON OR INSERTS SMALL BE WELDED TO AT&T MANHOLE REINFORCING STEEL AND EMBEDDED IN THE CONCRETE AT THE TIME OF AT&T MANHOLE FABRICATION. 3, FOUR 1/2" DIA. BRONZE GROUNDING INSERTS, WELDED TO THE MANHOLE REINFORCING STEEL, SHALL BE EMBEDDED IN THE FOUR OUTSIDE BOTTOM CORNERS OF THE AT&T MANHOLE. 4. FOUR STAINLESS STEEL 1/2" DIA. x 2" BOLTS SHALL BE INSERTED AT THE TIME OF THE AT&T MANHOLE PLACEMENT. 5. BACKFILL FOR MANHOLES INSTALLED TO BE CLEAN SAND BACKFILL PLACED IN ACCORDANCE WITH MUNICIPAL SPECIFICATIONS. 6. BASED ON PLANS TITLED 444-LA BY U.V, AUBURN (A DIVISION OF OLDCASTLE PRECAST INC.) AVAILABLE AT WWW.UVAUBURN,COM ISSUE DATE: JANUARY 2006. 7. MANHOLES SHALL COMPLY TO HS 20 LOAD RATINGS FOR PLACEMENT IN ROADWAYS CAST IRON MANHOLE FRAME AND COVER SHALL BE PART NO. E-1380 AS MANUFACTURED BY D&L FOUNDRY & SUPPLY (707-557-4525). COVER SHALL BE HEAVY-DUTY WITH A BLIND LIFTING HOLE AND SECURITY BOLTED. THE DESIGNATION "AT&T" SHALL BE CAST INTO THE CENTER OF THE COVER, COVER SHALL BE PAINTED WITH "46-450 HEAVY TNEMECOL" AS MANUFACTURED BY TNEMEC, (816) 483-3400. BROUGHT TO GRADE BY CONTRACTOR. DUCT ENTRANCE DETAIL TERM -A -DUCT ENTRANCE TYPICAL 6 PLACES IN VAULT NOT TO SCALE VAULT INTERIOR RISER No. 3606 ----�� KNOCKOUT (AS REQ'D) DIAPHRAGM ROUND ACCESS No. 44- 35C GALVANIZED "G" CHANNEL, 2'-0" LG.; 1 EACH SIDE 4 SIDES UV Co TERM -A -DUCT '90 STYLE FOR 4.50 PVC PIPE 36' DIA. 4 t• I :ooU. 0 CJ 00 SEE DETAIL A SEE DETAIL B OPTIONAL GALVANIZED PULLING IRON 1 EACH CORNER (2) 2 1/2" DIA. GROUND ROD SECTION AA KNOCKOUTS NOT TO SCALE R-3693221 L SUBSURFACE LnfUNFS,ASSNOWN HEREON, Wt1UEcdAP11E9A[MRMdm AVAILABLE EfocKDWF0RMA7IONNi0.N 1HEREFEEEMED COMPAMESAND PUAUC AGFN,=ES, AND THEIR LOCAnON, ARE APPROKDMTE a%Y. ACTUAL LOCATIONS MUST BE DETERMINED IN THE FIRLD. SIFNA ENGINEERING GROUP ASSuW[EN NO RFsPONSIBiuTY fOR DAMAG E510CUR RFD AS A RESULT OF MLOFES OMNTED DR INACCURAT7;LY SNowh. 2, REFERia PLANs TineD LAKEWXWKGTON TAmIMAot LIGMGUIDE STTTBM, AEµEWETO TACDMA03,SHEErS SN633656 A73.1" PROIECT 42120LA5 DU LVOM4JA1, W FLUOR COMMUMCATIONSSHA _S. !. REFER TO PLANSTOLEO STAANDER BOLAIVARD ERTEN3IDN, SYMmol t BOULEVARD PeXt- PHASE R, fly B. s.rAMM. Calf before you dig. Washington Utilities Coordinating Council 1-800-424-5555 AT&T PROPRIETARY (Internal Use Only) Not for disclosure outside the AT&T companies, except under written agreement. 2011 AT&T Intellectual Property, All AT&T YROPRIEfARY•This Information cunstftutes confidential trade secrets and commercial crfmancial infoflnadon owned by AT&T and is shared for Critical infrastrucure Protect cn purposes onlY. ItTs exempt froici disclosure underthe Freedom of Information Ast 15 U.S.C.554 Exemptions (b)(318,141, and its disclosure is prohibited underthe Trade Secrets Act (i9 u.S.0 1905), the Critical Infrastructure Inforration Act of 2002, 6 U.S.C. 133, and any State or local taw requiring disclosure of Information or records. This informatfon must not be cooled ord"Istributed to others not agreed upon by AT&T. but in all events do not copy or distribute to such others without notification pursuant to Executive Order 12600. PREPARED FOR RECORD IDE PLAN ENGINEER DAYt a t & t P£..EOYrI� .t•nr Yfi re^'9'e-v:c _.— ,e::h4dti — - 3FICATION: IECT NUMBER: JERSHiP: CODE: LE CW: .E: As NOTED BELLEVUE TO TACOMA 02 LIGHTGUIDE SYSTEM CONCRETE MANHOLE DETAILS - 444-LA 7 OF 14