HomeMy WebLinkAboutR-3693222I. MAY24, 2011 REMSEO BID ISSUE rn c0 M O W H GROUND ROD AND WIRE INSTALLATIONS FOR MANHOLES AND HANDHOLES ROUTE GROUND WIRE INTO MANHOLE NEXT TO DUCT(S) OR #6 AWG SOLID COPPER THROUGH A HOLE INSULATED GROUND WIRE DRILLED IN MANHOLE LEAVE SLACK COILED IN MANHOLE TO EXTEND 6' ABOVE LID #6 AWG SOLID COPPER Imo' GROUND WIRE BONDED TO GROUND ROD WITH PANDUIT GCE250-1/0 CRIMP COMPRESSION F:r CONNECTOR. A ; DUCT(S) 'GROUND F L �ROUIvD ROD �.:.;� --_ _ .: T•.=:: GROUNDING FOR MANHOLES NOT TO SCALE PANDUIT PARTS UST PANDUIT PART # DESCRIPTION GCE250-1/0 GROUND "E" STYLE CONNECTOR 5/8" GROUND ROD TO #6 SOLID (REQUIRED AT INSTALLATION OF MANHOLE/SPLICE BOX) GC£1/0-1/0 GROUND "E" STYLE CONNECTOR #6 SOLID WIRE TO #6 SOLID HARE (USED WHEN CONNECTING SPLICE CASE OR FILTER/ARRESTOR TO PREINSTALLED GROUND WIRE) CO-92OG-250 jDIE FOR 250 CONNECTORS CO-92OG--1/0 IDIE FOR 1/0 CONNECTORS CT-2931 IPORTABLE COMPRESSION TOOL 1.05" fl 2.66" GCE250-1 /0 CONNECTOR DETAIL NOT TO SCALE 0.66'I 1---- 0,94" I T 1.= 1.72" GCE1/0-1/0 CONNECTOR DETAIL NOT TO SCALE #6 AWG SOLID COPPER INSULATED GROUND WIRE LEAVE SLACK COILED IN HANDHOLE TO EXTEND 6' ABOVE GRADE 6" #6 AWG SOLID COPPER GROUND WIRE BONDED TO GROUND ROD WITH PANDUIT GCE250-1/0 CRIMP COMPRESSION CONNECTOR. 12" EXISTING GRADE HANDHOLE DUCT(S) BOTTOM OF TRENCH ROUTE WIRE INTO HANDHOLE NEXT TO DUCT(S) OR THROUGH A HOLE DRILLED IN SPLICE BOX 5/8"x8' GROUND ROD WITHIN 12" OF SPLICE BOX AND 6" BELOW TOP OF BOX GROUNDING FOR HANDHOLES NOT TO SCALE GROUNDING FOR MANHOLES AND HANDHOLES; THE GROUND ROD FOR A MANHOLE OR HANDHOLE SHOULD BE DRIVEN INTO NON --DISTURBED DIRT AS NEAR TO THE STRUCTURE AS POSSIBLE. UNDISTURBED DIRT HAS GREATER CONDUCTIVITY THAN COMPACTED FILL DIRT. IF UNABLE TO INSTALL THE ROD INTO UNDISTURBED DIRT NEAR THE STRUCTURE, DRIVE THE ROD DEEPER BELOW THE STRUCTURE IF POSSIBLE. THE TOP OF THE ROD SHOULD BE AT LEAST AS DEEP AS THE SHOULDER OF THE MANHOLE OR AT LEAST SIX INCHES BELOW THE TOP OF, THE HANDHOLE. THE GROUND WIRE WILL BE BONDED TO THE ROD WITH THE PROPER PANDUIT CRIMP CONNECTOR AND ROUTED INTO THE MANHOLE/HANDHOLE EITHER THROUGH ONE OF THE CABLE ENTRANCES OR A HOLE DRILLED INTO THE UPPER PART OF THE STRUCTURE. + THERE SHALL BE ENOUGH SLACK WIRE LEFT IN THE STRUCTURE TO EASILY REACH SIX FEET ABOVE THE MANHOLE LID OR SIX FEET ABOVE THE FINISH GRADE OVER THE HANDHOLE. THIS WILL EASE THE INSTALLATION OF FUTURE SPLICE CASES OR FILTER/ARRESTORS. COIL THE SLACK WIRE NEATLY AND USE PLASTIC TIES TO SECURE IT OUT OF THE WAY. R-3693222 1 SuarJRFACE Unurf UNFS, AS SHOWN HEREON, WEAEOOF,? ACccmweTO AVAAABLE AECOR9lNrOPMATI0.Y FROM THEAEFEAENEEO COMPANIESAHO PUBUCAGERCIK AND :NEW LOCATIONSAPE AMOxIMATE CNLY. ACTVAL LOCATIONS MUST RE DETERMINED IN THE FIN. SIENA EN'DL'MING CROUP ASSUMES NO R ESPONUBILDT toh DAMAGESIN"' ROW AT A AMULT DP U1a90 OM1EEE0 OR MMCCUAATELY SHOWN. 2 RIFERTO PLANSTInfO L&q WASHINGTON TAmMA02 UGHTGUIDE SYSTEM, 3ELLERAIETO TAODMA02 SHEETS WK-IU33125•A34 PROkCrd2R04A5 9UILTo2(24r86, eY RUOA COMM UNIC.TIONS SEAVICES. 3. RMILTO PUNSTULED SFRANDER BOULEVARD FPIEEHNON, STRANDER BOULEVARDPLAN-PHASE x, BY eorEETABAM, Call before you dig. Washington Utilities Coordinating Council 1-900-424-5555 AT&T PROPRIETARY [Internal Use Only) Not for disclosure outside the AT&T Companies, except underwritten agreement. Z011 AT&T Intellectual Property, All Rights Reserved _- AT&T PROPRICTARY This information consututes confiidentialtmde secrets and o0rnN eTCW0T f4iHottal information owned by AT&T and is shared for critical Infrastructure Protection purposes Only. it is exempt from disclosure under the freeaoro of Information Act 45 U.S.C. 552y, Exemptions (bl(3)&(4), and Its disclosure is Prohibited underthe Tfade Secrets Act Ila U.S.0 19o5I, the Critical Infrastructure InfOrmadon Act of 2002, 6 U.S.0 133, and any State or local law requiring disclosure of Informatlon or records. This information must not be copied or dlstrihCted to others not agreed upon by AT&T, but In all events do not copy or distribute to such others Without notification pursuant to Executive Order 12600, PREPARED FOR RECORD OUTstDE PtANi ENGINEER OAT- at&t EA vna.w"e.e:ro r.EEr.:::I: SPECIFICATION, PROJECT NUMBER: OWNERSHIP- LINE CODE: CABLE CLLI: SCALE: AS NOTED BELLEVUE TO TACOMA 02 UGHTGUIDE SYSTEM TYPICAL MANHOLE GROUNDING DETAILS 8OF14