Loading...
HomeMy WebLinkAboutR-3693223( ) 0) (0 M 0 0 LU H © is N n] O � EXISTING GRADE EXISTING GRADE q_ TRENCH 181. � I SEE SHEET 11 OF 14 FOR APPROPRIATE SURFACE RESTORATION DETAIL(S) 6" WIDE EXTRA STRENGTH NON —DETECTABLE WARNING TAPE ACP PART NUMBER 401004N—ND ,;..% LABELED: "WARNING, AT&T, CALL 1-800--252--1133, AT&T FIBER OPTIC CABLE BURIED BELOW" \� CLEAN SAND BACKFILL PLACED IN ACCORDANCE WITH RAILROAD SPECIFICATIONS "SEE"".DETAld'- / SEE 10 OF 14 FOR APPROPRIATE /\ TRENCH ARRANGEMENT DETAIL TYPICAL TRENCH DETAIL SCALE: 1 /2" = V-011 TRENCH `� 11 I I :f IN AREAS WITH LESS THAN 4' CLEARANCE UTILITY POLE OR PARALLELING GUARDRAILS 5' 5' INNERDUCTS MIN. i MIN. I F I STEEL PIPE I TYPICAL STEEL PIPE AT UTILITY POLES & GUARDRAILS NOT TO SCALE SEE SHEET 11 OF 14 FOR APPROPRIATE SURFACE RESTORATION DETAIL(S) 6" WIDE EXTRA STRENGTH NON --DETECTABLE WARNING TAPE ACP PART NUMBER 401004N—ND LABELED: "WARNING, AT&T, CALL 1-800-252-1133, AT&T FIBER OPTIC CABLE BURIED BELOW"co - z c g �— EXISTING UTILITY 12" MIN, TYPICAL TRENCH DETAIL PARALLEL TO EXISTING UTILITY SCALE: 1 /2" = 1'-0" CLEAN SAND BACKFILL PLACED IN ACCORDANCE WITH RAILROAD SPECIFICATIONS SEE 10 OF 14 FOR APPROPRIATE TRENCH ARRANGEMENT DETAIL EXISTING GRADE z G TRENCH 18' T '.SEE_DETAILS SEE SHEET 11 OF 14 FOR APPROPRIATE SURFACE RESTORATION DETAIL(S) 6" WIDE EXTRA STRENGTH NON —DETECTABLE WARNING TAPE ACP PART NUMBER 401004N—ND LABELED: "WARNING, AT&T, CALL 1-800-252-1133, AT&T FIBER OPTIC CABLE BURIED BELOW" CLEAN SAND BACKFILL PLACED IN ACCORDANCE WITH RAILROAD SPECIFICATIONS SEE 10 OF 14 FOR APPROPRIATE TRENCH ARRANGEMENT DETAIL EXISTING UTILITY TYPICAL TRENCH DETAIL CROSSING ABOVE AN EXISTING UTILITY SCALE: 1 /2" = V-0" TRENCH EXISTING 1 8 GRADE SEE SHEET 11 OF 14 FOR APPROPRIATE SURFACE RESTORATION DETAIL(S) 6" WIDE EXTRA STRENGTH NON —DETECTABLE WARNING TAPE ACP PART NUMBER 401004N—ND LABELED: WARNING, AT&T, CALL 1-800-252-1133, AT&T FIBER OPTIC CABLE BURIED BELOW" Y% N DETAILS. EXISTING UTILITY CLEAN SAND BACKFILL PLACED IN ACCORDANCE WITH RAILROAD SPECIFICATIONS SEE 10 OF 14 FOR APPROPRIATE TRENCH ARRANGEMENT DETAIL TYPICAL TRENCH DETAIL CROSSING BELOW AN EXISTING UTILITY NOTE: SCALE: 1/2" = 1'-0" SOUND TRANSIT COMPACTION REQUIREMENTS: EXCAVATIONS WITHIN THE SOUND TRANSIT ROW SHALL BE BACKFILLED AND COMPACTED TO NINETY—FIVE PERCENT (957.) MODIFIED PROCTOR DENSITY (ASTM 01557 OR AASHTO T-180) IN ALL AREAS. LIFTS SHALL NOT EXCEED SIX INCHES (6") IN DEPTH. FIELD COMPACTION TESTS SHALL BE MADE BY THE CONTRACTOR AT A MINIMUM OF EVERY TWO HUNDRED LINEAR FEET (200') OF TRENCH. FIELD COMPACTION TEST AT EACH LOCATION SHALL BE PERFORMED AS REQUIRED TO VERIFY COMPACTION HAS BEEN PERFORMED IN LIFTS THAT ACHIEVE 95 % AND AS DIRECTED BY THE CPM, THE PROPERTY/ROW OWNER AND LOCAL GOVERNING AUTHORITIES. R-3693223 2. MAY 2u, 2011 AHED EID ISSUE 1 suaawFACE(MLMUNts.ASSEIOWN MEREOEE. WERE CDMPILEDACCORDING10 AVAIIASUE RECOR) INFORMATION FROM THE NU""''CEe COMPANIES ANG PURot AGEWES.ANOTKIR tocAnUW ARE APPROIOMA'FoNLy. ACTUAL LOCATIONS MUST EE DETERAIINEDIN THEFIEUO. S ENA FNG IEEERING GROUP ASSUMES NO A6PONMUT`'FOR OAMAOES INCURAEPASA RESULT OF UIMIES UMITTEp 09 INACCURATELY S1enWN. 2. APFERTo FL4Ap'113?fD1ANFWASHINGrON TACOMAOt UGHTGUIDE SYMEK aEU.EVUFTO TAtOMA02 PUT5 WR-=Z3 T25-F3q PPMECr47470t,AS 9UiLT W/24/Es, aY RUOR CDMMUNIUMNSSERW ES. 3. REFER TOPLANSTnurp5TMNptR SOUIFVMD BTENSIUFL$InANDERaDULEVMO4LaN •PHASE R, BY Bug.ADAM. S Call before you dig. Washington Utilities Coordinating Council 1-800-424-5555 AT&T PROPRIETARY (Internal Use Only) Not for disclosure outside the AT&T companies, except underwritten agreement. 2011 AT&T Intellectual Property, All Rights Reserved AT&T PROPRIfTARY This £nrormation constitutes confidential trade secrets and commerclai oT Rnarlc£al information owned by AT&T and £s shaFed for Critical InffanTuttwe Protectbn purposes only. It Is exempt from disclosure under the Freedom of Information Act (5 V.S.C.552), fxemptiuns (b)(3)&(4), and its disclosure is Prohibited under the Trade Secrets Act (18 U.S.C. IMS), the Critical infiestrUcture Information ACt of 2OD4 6 U.S.0 "a, and any State or tout Few teci king disdoswe of information ar records. This information must not be copled or distributed to others not agreed upon by AT&T, but In all events do not copy or distribute to such others without notifcatlon pursuant to Executive Order 12600. PREPARED FOR RECORD APPROVED P311 OUTS{DE PLANT ENGINEER DATE at&t IENA "'eiurR:ea ewAi SPECEFICATION: PROJECTNUMBER: Ij NERSHIP: LINE CODE CABLE CLU: SCALE: AS NOTED BELLEVUE TO TACOMA 02 LIGHTGUIDE SYSTEM TYPICAL TRENCH DETAILS BOF14