HomeMy WebLinkAboutR-3693228L. MAY24,2011 R-I -SEO 910 MUE
co GENERAL NOTES.
M
co 1. STRUCTURAL STEEL AS PER A.S.T.M. SPECS. A-36,
2. EXISTING PAINT ON THE STEEL SPAN SHALL BE REPAIRED IN KIND IF DAMAGED BY THE
INSTALLATION OF THE CONDUIT HANGER SYSTEM IN ACCORDANCE WITH BRIDGE OWNERS
p CURRENT STANDARDS.
LU 3. HOLES NECESSARY FOR THE INSTALLATION OF THE ATTACHMENT SHALL ONLY BE MADE BY WALKWAY
DRILLING, NOT BY BURNING OR CUTTING.
4. DRILLED HOLES SHALL BE PAINTED WITH A PRIME COAT BEFORE BOLTS ARE PLACED,
5. THE DRILLING OF EXTRA HOLES THAT ARE NOT DIRECTLY RELATED TO THE HANGER
ATTACHMENTS SHALL NOT BE ALLOWED INTO ANY EXISTING BRIDGE MEMBER, FOR EXAMPLE, = -� ' _=` c
HOLES FOR WORK PLATFORMS ARE NOT ALLOWED. - - .-:1. DOUBL NUTS ON
1OX" TOP (TYP)
6. BRACKETS TO BE BOLTED TO EVERY WALKWAY BRACKET OF STEEL SECTIONS -- REFER TO
SHEET 12 OF 14. I 7,
7. MINIMUM CLEAR DISTANCE BETWEEN BRIDGE STRUCTURE AND SUPPORT HANGER IS 8". GRAVEL 23 I 0 j 4� 9s..
8. HARDENED WASHER TO BE PLACER UNDER TURNED ELEMENT OF EACH BOLT. BALLAST ( fsa" r /
9. BRIDGE STEEL SHALL NOT BE MODIFIED OR ALTERED BY CUTTING BURNING, OR BY ANY
OTHER MEANS. EXISTING BOLTS SHALL NOT BE REMOVED OR ALTERED. 2 7 425laz
10. STEEL CONDUIT HORIZONTAL AND VERTICAL ALIGNMENT WITHIN BRACKET TO BE DETERMINED �y.:`•,.,; ;
BY PASSAGE POINT THROUGH ABUTMENT BACKWALL. % i`'FPR —T
L n
Q U
N Pli
9 d
2 I
F-
r
LW
z w
x
G 7
O 0
a �
LJ to
a<
a� �o
Cd E
0 E .t
(9• o .r
4U rvN
d m
# N N
Z o o,
2 o q f SpE
Z r"N%Ta
�o>�o
lQ vi U 11,1 4
BRIDGE
ATTACHMENT
}G�
ATTACHMENTS
(BY OTHERS)
A4 BRACKET PLACEMENT DETAIL
(FACING NORTH)
NOT TO SCALE
CURB
SUPPORT
0� 7/1 rF
4G
0
-3 n
WALKWAY
BRACKET
3. 5VBSURFACEU7IUTYU1(' . PSSI'IIWN MREON,
WEREIDMPILWACCOWNM TO AVAnA:LE
AECOA0 INFORMATION FROM THE REFEAENCEO
C WPAN1E1 AND PUBLIC AGMZS, AND THEIR
LOCATIONS ARE APPROWMATE ONLY, ACTUAL
(+ �y
CONNECTION
LOCATIONS MUST BE DETERMINEOWTHEFIELO.
AMA tNGINEMING GROUP ASSUMES No
REspO svurYEO.RoAMAGT.s LNCURREDASA
ANGLE CA2
pI, oPUTILTIES OMITTED ORSNACCURATELY
(HOT DIPPED
SHOWN.
7 AEFEATO PUNS TTELm LAKE WMI41NMON
GALVANIZED)
TACOMAW L GHYUUIOE SI M 9EL EVUETO
ETS 7ACOMA M SHEWFA SO 03M-R
FPCISCT421201, AS BUILTOV2418A. BY fWCR
LI % U
L2Y2"x2 x /e
MMD [OKUTI0.NSSEAVfm
z
3. REPFATO P,
smANDGRRcRANOERBOLN-PR0
fILTE1tSlON, STRPNDfA BOULEVARD PLAN -PHASE
IL UP ae.R—EAM-
`— 13A6"O HOLES FOR
�4"O THREADED
I RODS
Tf6"O HOLES FOR
%"4 GALVANIZED
HIGH STRENGTH
DOLTS
VARIES*
7 8"
l
VARIES*
N. /-- DOUBLE NUTS ON
THREADED BOTTOM (TYP.)
ROD CENTER PUNCHED
AT THREAD TO
PREVENT MOVEMENT
6" GALVANIZED
STEEL CONDUIT
W/(4) INNERDUCTS
A4 BRACKET DETAIL
(FACING NORTH)
NOT TO SCALE
* TO BE DETERMINED IN FIELD
R-3693228
Call before you dig.
Washington Utilities
Coordinating Council
1-800-424-5555
AT&1 PROPRIETARY
(Internal Use Only)
Not for disclosure outside the AT&T
companies, except under written
aareement-
2011 AT&T Intellectual Property, All
Rights Reserved
AT&T PROPRIETARY -This information
constitutes confldential trade secrets and
commercial arffnanclal htformatfon owned
by AT&T and is.hared for Critical
i,f.0 ucwre Protection purposes only. It Is
exempt from disclosure underthe Freedom
of information Act (5 U.S-C 5521,
Exemptions (b)(3)&(4j, and Its disclosure N
prohibited under the Trade Secrets Act
(18 US.0 1905), the Critical Infrastructure
Information Act of 2002, 6 U.S.0 133, and
any State or local law requiring disclosure of
information or records. This iMormatlon
mustnot be copied ordtstributed to others
not agreed upon by AT&T. but in all evens
do not copy or distribute to such others
without notification pursuantto Executive
PREPARED FOR RECORD
APPROVED FOR -_
OUTSIDEPLANT E 0-- WE
afi&fi
ENA
SPECIRCATION: �
PRWECT NUMBER:
OWNERSHIP:
LINE CODE:
CABLE CLU:
SCALE: AS NOTED
BELLEVUE TO TACOMA 02
LIGHTGUIDE SYSTEM
BRIDGE ATTACHMENT
BRACKET DETAIL
14 OF 14