Loading...
HomeMy WebLinkAboutT-369315co M co co 6 NW1/4,SEC 25,T23N, R4E,W.M. CV 0 0') T �, N N CD N N J U N w N N CD N O N rel J w w Cn w Cn 0 N + ti w z J U LUMINAIRE SCHEDULE NO. COR POLE ID # LOCATION OFFSET ISTRIBUTION TYPE LAMP TYPE FIXTURE STYLE ARM LENGTH POLE HEIGHT POLE TYPE 1 STA "S" 24+62 3 LED - 80E AT 530mA COBRA HEAD 8 FT. 35 FT. TAPERED ALUMINUM 2 STA "S" 23+14 35' RT 2 LED - 80E AT 530mA COBRA HEAD 8 FT. 35 FT. TAPERED ALUMINUM 3 STA "S" 21+42 > 35' RT 2 LED - 80E AT 530mA COBRA HEAD 8 FT. 35 FT. TAPERED ALUMINUM 4 STA "S" 20+08 38.5' RT 2 LED - 80E AT 530mA COBRA HEAD 8 FT. 35 FT. TAPERED ALUM I NUM 5 STA "S" 18+80 2 LED - 80E AT 530mA COBRA HEAD 8 FT. 35 FT. TAPERED ALUM I NUM 6 STA "S" 17+15 2 LED - 80E AT 530mA COBRA HEAD 8 FT. 35 FT. TAPERED ALUMINUM 7 STA "AR" 00+8 35' RT 3 LED - 80E AT 530mA COBRA HEAD 8 FT. 35 FT. TAPERED ALUM I NUM FEDAID: STPUL-1276(004) HPP-1276(005) CALL 48 HOURS BEFORE ❑O❑ DI ❑ 1-800-424-5555 BergerABAM 6021 12TH STREET E., SUATE 200 N&AZ TACOMA, WA 98424 33301 9th Avenue South, Suite 300 ENGINEERS, INC. (253) 922-0446 FAX (253) 922-0896 Federal Way, Washington 98003-2600 (206) 431-2300 Fax: (206) 431-2250 CONDUITMIRE SCHEDULE DESIGNATION CONDUIT SIZE CONDUCTOR SIZE & QUANTITY CIRCUIT TYPE A 2" PVC 2 #8 & 1 #8 GR 1 2" PVC PULL STRING SPARE 3" PVC PULL STRING SPARE B 2" PVC 2 #8 & 1 #8 GR ILLUMINATION C 1-1/2" PVC 2 #8 & 1 #8 GR ILLUMINATION D 3/4" RGS 2 #8 & 1 #8 GR ILLUMINATION E 2" PVC EXISTING 2 #8 & 1 #8 GR ILLUMINATION co J w Cn w U) 0 00 N Q C~/) z U Q A 20 0 20 40 scale feet 1 PEDESTRIAN PATH REALIGNMENT CT 2-14-13 s"RVEtM. SQ&E* AS SHOWN HORIZ�ONU�Lc • N D ; 983�%198, DATUM �1 CITY OF v 't' FN.� RENTON Public Works Department Approved For Construction SPARE 2" CONDUIT CT 5-28-13 DEMM. CT RFI 00120 CT 5-08-14 OC ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY . RH NO. REVISION BY DATE APPR H Robert M. Hanson P.E. Date GENERAL NOTES 1. ALL PVC CONDUITS SHALL CONTAIN EQUIPMENT GROUNDING CONDUCTOR. ALL CONDUITS UNDER THE ROADWAY SHALL BE PVC SCHEDULE 80. 2. PROVIDE FOUNDATION FOR EACH LIGHT FIXTURE PER RENTON STD PLAN J-1 b. 3. PROVIDE 10 POLE AND BRACKET CABLE UP EACH POLE. 4. ALL LUMINARIES SHALL HAVE FUSES LOCATING IN THE POLE BASE. 5. ALL SPLICES SHALL BE MADE IN JUNCTION BOXES. 6. SEE LUMINARIES SCHEDULE FOR STREET LIGHT POLE LOCATIONS. 7. ALL JUNCTION BOXES PER WSDOT STD PLAN J-40.10-01. 8. PROVIDE NUMBERING ON EACH POLE PER RENTON STD PLAN J009 9. COORDINATE LIGHT POLE FOUNDATIONS WITH UNDERDRAIN SYSTEM. CONSTRUCTION NOTES 1� ROUTE CONDUIT SURFACE MOUNT UP CONCRETE PIER TO LIGHT. �2 PROVIDE J—BOX TYPE 1 CONCRETE HANDHOLE W/LOCKING DIAMOND PLATE COVER. Q3 PROVIDE CONCRETE PAD AND JUNCTION BOX PER RENTON STD PLANS J007 AND J008. 4� MOUNT FIXTURE AS HIGH UP ON THE WALL AS PHYSICALLY POSSIBLE. Q LIGHT POLE BASE TO BE INTEGRATED AS PART OF CONCRETE WALL. SEE DETAIL ON DRAWING SW-10 FOR DETAIL. HANDHOLE TO BE MOUNTED BEHIND THE WALL. 6Q PROVIDE J—BOX TYPE 2. CONCRETE HANDHOLE W/ LOCKING DIAMOND PLATE COVER. STRANDER BOULEVARD EXTENSION PHASE II ILLUMINATION PLAN SHEET 2 12/5/2011 FIELDID". PAGE: IL-2 132--231