LUMINAIRE SCHEDULE
NO.
COR
POLE
ID #
LOCATION
OFFSET
ISTRIBUTION
TYPE
LAMP TYPE
FIXTURE STYLE
ARM
LENGTH
POLE
HEIGHT
POLE TYPE
1
STA "S" 24+62
3
LED - 80E AT 530mA
COBRA HEAD
8 FT.
35 FT.
TAPERED ALUMINUM
2
STA "S" 23+14
35' RT
2
LED - 80E AT 530mA
COBRA HEAD
8 FT.
35 FT.
TAPERED ALUMINUM
3
STA "S" 21+42 >
35' RT
2
LED - 80E AT 530mA
COBRA HEAD
8 FT.
35 FT.
TAPERED ALUMINUM
4
STA "S" 20+08
38.5' RT
2
LED - 80E AT 530mA
COBRA HEAD
8 FT.
35 FT.
TAPERED ALUM I NUM
5
STA "S" 18+80
2
LED - 80E AT 530mA
COBRA HEAD
8 FT.
35 FT.
TAPERED ALUM I NUM
6
STA "S" 17+15
2
LED - 80E AT 530mA
COBRA HEAD
8 FT.
35 FT.
TAPERED ALUMINUM
7
STA "AR" 00+8
35' RT
3
LED - 80E AT 530mA
COBRA HEAD
8 FT.
35 FT.
TAPERED ALUM I NUM
FEDAID: STPUL-1276(004)
HPP-1276(005)
CALL 48 HOURS
BEFORE ❑O❑ DI ❑
1-800-424-5555
BergerABAM 6021 12TH STREET E., SUATE 200
N&AZ TACOMA, WA 98424
33301 9th Avenue South, Suite 300 ENGINEERS, INC. (253) 922-0446 FAX (253) 922-0896
Federal Way, Washington 98003-2600
(206) 431-2300 Fax: (206) 431-2250
CONDUITMIRE SCHEDULE
DESIGNATION
CONDUIT SIZE
CONDUCTOR SIZE &
QUANTITY
CIRCUIT TYPE
A
2" PVC
2 #8 & 1 #8 GR
1
2" PVC
PULL STRING
SPARE
3" PVC
PULL STRING
SPARE
B
2" PVC
2 #8 & 1 #8 GR
ILLUMINATION
C
1-1/2" PVC
2 #8 & 1 #8 GR
ILLUMINATION
D
3/4" RGS
2 #8 & 1 #8 GR
ILLUMINATION
E
2" PVC EXISTING
2 #8 & 1 #8 GR
ILLUMINATION
co
J
w
Cn
w
U)
0
00
N
Q
C~/)
z
U
Q
A
20 0 20 40
scale feet
1
PEDESTRIAN PATH REALIGNMENT
CT
2-14-13
s"RVEtM.
SQ&E*
AS SHOWN
HORIZ�ONU�Lc • N D ; 983�%198,
DATUM
�1 CITY OF
v 't'
FN.� RENTON
Public Works Department
Approved For Construction
SPARE 2" CONDUIT
CT
5-28-13
DEMM.
CT
RFI 00120
CT
5-08-14
OC
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
.
RH
NO.
REVISION
BY
DATE
APPR
H
Robert M. Hanson P.E. Date
GENERAL NOTES
1. ALL PVC CONDUITS SHALL CONTAIN EQUIPMENT
GROUNDING CONDUCTOR. ALL CONDUITS UNDER THE
ROADWAY SHALL BE PVC SCHEDULE 80.
2. PROVIDE FOUNDATION FOR EACH LIGHT FIXTURE PER
RENTON STD PLAN J-1 b.
3. PROVIDE 10 POLE AND BRACKET CABLE UP EACH
POLE.
4. ALL LUMINARIES SHALL HAVE FUSES LOCATING IN
THE POLE BASE.
5. ALL SPLICES SHALL BE MADE IN JUNCTION BOXES.
6. SEE LUMINARIES SCHEDULE FOR STREET LIGHT POLE
LOCATIONS.
7. ALL JUNCTION BOXES PER WSDOT STD PLAN
J-40.10-01.
8. PROVIDE NUMBERING ON EACH POLE PER RENTON
STD PLAN J009
9. COORDINATE LIGHT POLE FOUNDATIONS WITH
UNDERDRAIN SYSTEM.
CONSTRUCTION NOTES
1� ROUTE CONDUIT SURFACE MOUNT UP
CONCRETE PIER TO LIGHT.
�2 PROVIDE J—BOX TYPE 1 CONCRETE
HANDHOLE W/LOCKING DIAMOND PLATE
COVER.
Q3 PROVIDE CONCRETE PAD AND JUNCTION BOX
PER RENTON STD PLANS J007 AND J008.
4� MOUNT FIXTURE AS HIGH UP ON THE WALL
AS PHYSICALLY POSSIBLE.
Q LIGHT POLE BASE TO BE INTEGRATED AS
PART OF CONCRETE WALL. SEE DETAIL ON
DRAWING SW-10 FOR DETAIL. HANDHOLE TO
BE MOUNTED BEHIND THE WALL.
6Q PROVIDE J—BOX TYPE 2. CONCRETE
HANDHOLE W/ LOCKING DIAMOND PLATE
COVER.
STRANDER BOULEVARD EXTENSION
PHASE II
ILLUMINATION PLAN
SHEET 2
12/5/2011
FIELDID".
PAGE:
IL-2
132--231